333 resultados para Cromo hexavalente


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental study was undertaken in arder to find out lhe behavior of the required force to yield dislodgement of circumierential clasps of removable partial dentures ou two groups of samples. 1 with retentive terminais engaging and acting ou enamel 2 with retentive terminais engaging on enamel and acting on composite resm With this aim a device was designed based on a sewing machine (brand name Elgin) that could repeatedly simulate lhe introduction-removal movement of circunferencial clasps ou the samples. ln addiction the device had a platform to sustain the samples and permit measurements, a cycle counter and a dynamometer. The samples were constructed by inclusion in dental stone of extracted natural molar teeth whose retentive areas were ou natural enamel or composite resin addictions.The clasps were fabricated from wax ups of resin and wax and were cast with chromium cobalt alloy. The composite resin used was one of the last generation, monomodal type, photopolymerized and binded to the enamel by the acid etching technique. Tests were carried out in aqueous enviroment. Is was established a maximum of 5.000 cycles for each of the samples. Observatins were made from 100 to 100 cycles until 2.000 and from 200 to 200 cycles to 5.000. Results showed that variations in the amount of the required force for dislodgement of the clasps from the samples during the test periods had no significancy eather to those with retentive areas on the enamel or to those with retentive fabricated with addictions of composite resin

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several alloys have been used for prosthodontics restorations in the last years. These alloys have a number of metals that include gold, palladium, silver, nickel, cobalt, chromium and titanium and they are used in oral cavity undergo several corrosion. Corrosion can lead to poor esthetics, compromise of physical properties, or increased biological irritation. The objective of this study was evaluated corrosion resistance of two alloys Ni-Cr and Ni-Cr-Ti in three types of mouthwashes with different active ingredients: 0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride, 0.05% sodium fluoride + 0.03% triclosan (with fluor) and 0.12% chlorohexidine digluconate. The potentiodynamic curves were performed by means of an EG&G PAR 283 potentiostat/galvanostat. The counter electrode was a platinum wire and reference electrode was an Ag/AgCl, KCl saturated. Before each experiment, working electrodes were mechanically polished with 600 and 1200 grade papers, rinsed with distilled water and dried in air. All experiments were carried out at 37.0oC in conventional three-compartment double wall glass cell containing mouthwashes. The microstructures of two alloys were observed in optical microscopy. Analysis of curves showed that Ni-Cr alloy was less reactive in the presence of 0.12% chlorohexidine digluconate while Ni-Cr-Ti alloy was more sensitive for others two types of mouthwashes (0.5g/l cetylpyridinium chloride + 0.05% sodium fluoride  and 0.05% sodium fluoride + 0.03% triclosan). This occurred probably due presence of titanium in this alloy. Microstructural analysis reveals the presence of dendritic and eutectic microstructures for NiCr and Ni-Cr-Ti, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O aço austenítico manganês, descoberto inicialmente por Robert Hadfield, em 1882, conhecido atualmente como aço Hadfield, continha em sua configuração inicial 12% de manganês e 1,2% de carbono. Apresentando grande resistência ao desgaste, provavelmente o maior na categoria de aciaria, ganhou rápida aceitação no mercado, sendo então propostas várias alterações em sua composição, como a introdução de vários elementos de liga, como o vanádio, molibdênio, titânio, enxofre, fósforo, cromo, níquel, entre outros. Este trabalho investigou a influência dos elementos de liga na resistência ao desgaste e no encruamento sofrido por esse material, em quatro composições que se diferenciam nos elementos de liga e em suas porcentagens. A resposta foi uma grande resistência ao desgaste da liga contendo titânio, entretanto esta não apresentou a maior profundidade de camada encruada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ceramic powders based on Zn3Ga2Ge2O10: Cr3+ X% (X = 0.0; 0.5; 0.75; 1.0) were synthesized by solid-state reaction method. The gallium-zinc germanate doped with chromium presents an interesting property of phosphorescence, that means, it is capable of emitting light when excited by a source of radiation, and such emission remains for some time after stopping the source. For this reason, these materials can be widely applied in night-vision surveillance, (through the use of solar energy, for example), electronic devices screen, emergency routes signals, control panels indicators in dark environments, etc. In this job were considered different amounts of dopant in order to perform a comparison of structural and photoluminescent properties. For that, some analyses were performed on samples, such as XRD, FT-Raman, SEM, UV-vis and photoluminescence measurements (PL). Such analysis allowed to infer that the presence of chromium results in no phase transformation, so that the four compositions have the same set of phases: cubic, rhombohedral and hexagonal. Although the structure was not changed, chromium influences other properties / characteristics of these materials. Examples are: increase of band-gap, decrease of average particle size, small changes in binding energy checked by Raman and especially the increase of photoluminescent property. The chromium ions have great ease in replacing gallium ions in octahedral sites, resulting in emission of light with a wavelength of about 700 nm (infrared region), which is justified by the spin-forbidden 2E 4A2 transition. In other words, chromium is a favorable luminescent center, acting as a trap in the crystal structure, since it imprisons the excitation energy easily and releases it gradually, allowing the phosphorescence. It was observed that the composition ... (Complete abastract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sono stati studiati gli effetti tossici dell’esposizione cronica a cobalto e cromo. In passato, questa tossicità, che colpiva lavoratori esposti per ragioni occupazionali, è stata un problema molto sentito. Tuttavia, recenti pubblicazioni hanno descritto una specifica tossicità mediata da elevati livelli di cobalto e cromo, anche in pazienti portatori di protesi metalliche, quali gli impianti d’anca. Anche se sintomi clinici tra cui, cecità, sordità e neuropatia periferica, suggeriscono uno specifico neurotropismo, ancora poco è conosciuto delle basi neuropatologiche di questo processo ed oltretutto non ne è ancora stata apportata un’evidenza sperimentale. In questo progetto di ricerca, quindi, si è voluto approfondire il meccanismo patogenetico da cui scaturiscono tali sintomi neurologici, utilizzando come modello sperimentale il coniglio. Conigli New Zealand White sono stati trattati con dosi endovenose ripetute di cobalto e cromo, inoculati singolarmente od in associazione tra loro. Nessuna evidente alterazione clinica o patologica è stata associata alla somministrazione di solo cromo, nonostante gli elevati livelli in sangue e tessuti, mentre i trattati con cobalto-cromo o solo cobalto hanno mostrato segni clinici gravanti sul sistema vestibolo-cocleare; il cobalto, quindi, è stato identificato come il maggiore elemento scatenante neurotossicità. Inoltre all’esame istopatologico gli animali hanno mostrato severa deplezione delle cellule gangliari retiniche e cocleari, assieme a danno al nervo ottico e perdita di cellule sensitive capellute dell’orecchio. È risultato infine evidente che la gravità delle alterazioni è stata correlata al dosaggio ed al tempo di esposizione; dati questi che confermano, quindi, le precedenti osservazioni fatte su pazienti umani esposti a rilascio abnorme di cobalto e cromo da usura di protesi d’anca. È stato ipotizzato che il cobalto agisca sui mitocondri provocando l’incremento di produzione di specie reattive dell’ossigeno e il rilascio di fattori proapoptotici, causando sulle cellule neuronali un danno proporzionale al loro fabbisogno energetico e grado di mielinizzazione.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lo scopo di questo studio è stato quello di determinare se a lungo termine le concentrazioni sieriche di ioni nei pazienti con protesi di rivestimento d’anca metallo-metallo (MOM-HR, metal-on-metal hip resurfacing) fossero differenti da quelle valutate nei pazienti con protesi totale d’anca metallo-metallo e testa del diametro di 28 mm (MOM-THA, metal-on-metal total hip arthroplasty); inoltre è stato valutato se le concentrazioni ioniche fossero al di sopra dei valori di riferimento e se fosse possibile stabilire l’esistenza di una relazione tra sesso e concentrazioni di ioni con riferimento al tipo di impianto. Il gruppo MOM-HR era costituito da 25 pazienti mentre il gruppo MOM-THA era di 16 pazienti. Per poter ricavare i valori di riferimento sono stati reclutati 48 donatori sani. La misurazione delle concentrazioni degli ioni cobalto (Co), cromo (Cr), nickel (Ni) e molibdeno (Mo) è stata effettuata utilizzando la spettrofotometria ad assorbimento atomico su fornace di grafite. A parte il Ni, le concentrazioni di ioni nei pazienti con MOM-HR erano più elevate rispetto ai controlli. Il rilascio di ioni Cr e Co nei pazienti con MOM-HR è risultato superiore rispetto ai soggetti con MOM-THA. Da un’analisi basata sul sesso, è emerso che nelle femmine con MOM-HR i livelli di ioni Cr e Co sono risultati significativamente aumentati rispetto alle femmine con MOM-THA. Indipendentemente dal tipo di impianto, gli accoppiamenti metallo-metallo (MOM) producono concentrazioni di ioni metallici significativamente più alte a follow-up a lungo termine rispetto a quelle osservate nei soggetti sani. Un fattore che deve essere attentamente considerato nella scelta dell’impianto, e in particolar modo nei soggetti giovani, è il cospicuo rilascio di ioni Cr e Co nella popolazione femminile con MOM-HR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il suolo è soggetto all’attacco di svariati contaminanti rilasciati nell’ambiente da parte dell’uomo, fra questi troviamo i metalli pesanti. Alcuni metalli pesanti risultano tossici per organismi animali e vegetali se superano certe soglie di concentrazione. Nei suoli i metalli pesanti si trovano sia per cause naturali che antropiche. La fonte naturale dei metalli è legata alla struttura, composizione mineralogica, granulometrica dei sedimenti, e al grado di alterazione dovuta ai vari processi pedogenetici da cui è nato il suolo. In questo lavoro di tesi ho realizzato un campionamento che fosse rappresentativo dell’area presa in esame. In base alle geologia della zona, sono state individuate 32 stazioni dove è stata effettuata la perforazione, ottenendo un totale di 58 campioni. Lo scopo di questa tesi consiste nella determinazione e caratterizzazione cartografica del contenuto dei metalli pesanti nei suoli posti a ovest di Mantova. Per ogni campione è stata eseguita l’analisi per la determinazione del contenuto totale degli elementi maggiori e di quelli in traccia tramite fluorescenza a raggi X (XRF) ,il calcolo della LOI. Dai dati ottenuti dall’analisi XRF è stato applicato l’indice di geoaccumulo, il quale ha fornito il livello di arricchimento superficiale per Cromo, Nichel, Rame, Zinco, Piombo, Arsenico e Vanadio, permettendo di effettuare una stima della contaminazione puntiforme dell’area. Lo studio si è concluso con la realizzazione di mappe di concentrazione di metalli pesanti. La creazione di mappe pedogeochimiche diviene sempre più importante per una completa gestione territoriale ed ambientale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il suolo, oltre a rappresentare la base su cui si sviluppa la vita, è anche il luogo in cui si sviluppano l’industrializzazione, le reti viarie, i commerci; è quindi sottoposto a continue pressioni di tipo antropico che inducono modificazioni chimiche, biologiche della sua composizione. I metalli pesanti sono tra i più importanti inquinanti del suolo, sebbene siano presenti all’interno di esso come materiale costituente, le loro concentrazioni possono aumentare a causa di immissioni antropiche, modificando quindi la struttura del suolo rendendolo inquinato. In questo lavoro di tesi, avente come area d’interesse una porzione della provincia di Mantova precisamente ad est della città e parte della provincia di Verona e Rovigo si è voluto analizzare le caratteristiche composizionali dei suoli, al fine di determinare situazioni di arricchimento imputabili o all’uso del suolo o all’origine del sedimento. A questo proposito si è ritenuto opportuno impostare un confronto tra le concentrazioni totali dei metalli in superficie e quelle in profondità, questo non è stato sempre possibile in quanto la litologia dell’area non ha permesso, in alcuni casi, il prelievo del campione profondo. I suoli sono stati sottoposti ad analisi per il contenuto totale degli elementi maggiori e in traccia tramite analisi XRF, è stata poi eseguita la Loi per determinare la percentuale di perdita della materia organica, applicato l’indice di geoaccumolo ed infine sono state create grazie all’ausilio del software Qgis mappe di concentrazione di metalli pesanti quali Cromo, Nichel, Rame, Zinco, Piombo, Arsenico e Vanadio relative all’area di interesse di questo lavoro di tesi.