924 resultados para Axial compression


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A quarkonium-gluonium mixing scheme previously developed to describe the characteristic of the pseudoscalar mesons is applied to axial and tensor mesons. The parameters of the model are determined by fitting the eigenvalues of a mass matrix. The corresponding eigenvectors give the proportion of light quarks, strange quarks and glueball in each meson. However, the predictions of the model for the branching ratios and electromagnetic decays are incompatible with the experimental results. These results suggest the absence of gluonic components in the states of axial and tensor isosinglet mesons analyzed here.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber reinforced polymer composites have been widely applied in the aeronautical field. However, composite processing, which uses unlocked molds, should be avoided in view of the tight requirements and also due to possible environmental contamination. To produce high performance structural frames meeting aeronautical reproducibility and low cost criteria, the Brazilian industry has shown interest to investigate the resin transfer molding process (RTM) considering being a closed-mold pressure injection system which allows faster gel and cure times. Due to the fibrous composite anisotropic and non homogeneity characteristics, the fatigue behavior is a complex phenomenon quite different from to metals materials crucial to be investigated considering the aeronautical application. Fatigue sub-scale specimens of intermediate modulus carbon fiber non-crimp multi-axial reinforcement and epoxy mono-component system composite were produced according to the ASTM 3039 D. Axial fatigue tests were carried out according to ASTM D 3479. A sinusoidal load of 10 Hz frequency and load ratio R = 0.1. It was observed a high fatigue interval obtained for NCF/RTM6 composites. Weibull statistical analysis was applied to describe the failure probability of materials under cyclic loads and fractures pattern was observed by scanning electron microscopy. (C) 2010 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the thickness of the periodontal ligament of rat molars during orthodontic tooth movement (OTM). METHODS: Thirty Wistar rats were divided into three groups of 10 animals each: GI, GII and GIII and the mice were euthanized at 7, 14 and 21 days, respectively. Experimental subjects were compared to their respective controls by the Mann-Whitney test. Comparison of values between compression and tension sides were performed during the same and different time periods through Analysis of Variance (ANOVA), Kruskal-Wallis test and, subsequently, Tukey's test. RESULTS: Groups GI and GII showed decreased PDL size in the apical regions of the mesiobuccal root and in the cervical region of the distobuccal root. There was also an increased PDL in the cervical regions of the mesiobuccal root, apical region of the distobuccal root and middle region of both roots. CONCLUSION: The reduction and increase in PDL size were seen in the same root, which characterizes tooth inclination. The apical, middle and cervical regions were compared with one another in each time period and at three times: 7, 14 and 21 days. They were also compared in each region, confirming a tipping movement in GI and GII and a gradual decreased intensity between GI to GII, reaching normal dimension in GIII.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tanomaru-Filho M, Silveira GF, Reis JMSN, Bonetti-Filho I, Guerreiro-Tanomaru JM. Effect of compression load and temperature on thermomechanical tests for gutta-percha and Resilon (R). International Endodontic Journal, 44, 1019-1023, 2011.Aim To analyse a method used to evaluate the thermomechanical properties of gutta-percha and Resilon at different temperatures and compression loads.Methodology Two hundred and seventy specimens measuring 10 mm in diameter and 1.5 mm in height were made from the following materials: conventional gutta-percha (GCO). thermoplastic gutta-percha (GTP) and Resilon (R) cones (RE). After 24 h, the specimens were placed in water at 50 degrees C. 60 degrees C or 70 degrees C for 60 s. After that, specimens were placed between two glass slabs, and loads weighing 1.0, 3.0 or 5.0 kg were applied. Images of the specimens were digitized before and after the test and analysed using imaging software to determine their initial and final areas. The thermomechanical property of each material was determined by the difference between the initial and final areas of the specimens. Data were subjected to ANOVA and SNK tests at 5% significance. To verify a possible correlation between the results of the materials, linear regression coefficients (r) were calculated.Results Data showed higher flow area values for RE under all compression loads at 70 degrees C and under the 5.0 kg load at 60 degrees C (P < 0.05). Regarding gutta-percha, GTP showed higher flow under loads weighing 3.0 and 5.0 kg. at 60 and 70 degrees C (P < 0.05). GCO presented higher flow at 70 degrees C with a load of 5.0 kg. Regression analyses showed a poor linear correlation amongst the results of the materials under the different experimental conditions.Conclusion Gutta-percha and Resilon (R) cones require different compression loads and temperatures for evaluation of their thermomechanical properties. For all materials, the greatest flow occurred at 70 degrees C under a load of 5.0 kg: therefore. these parameters may be adopted when evaluating endodontic tilling materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of physical phenomena that occurs during tablet disintegration has been studied by several experimental approaches; however none of them satisfactorily describe this process. The aim of this study was to investigate the influence of compression force on the tablets by associating the AC Biosusceptometry with consolidated methods in order to validate the biomagnetic technique as a tool for quality control in pharmaceutical processes.Tablets obtained at five compression levels were submitted to mechanical properties tests. For uncoated tablets, water uptake and disintegration force measurements were performed in order to compare with magnetic data. For coated tablets, magnetic measurements were carried out to establish a relationship between physical parameters of the disintegration process. According to the results, differences between the compression levels were found for water uptake, force development and magnetic area variation measurements. ACB method was able to estimate the disintegration properties as well as the kinetics of disintegration process for uncoated and coated tablets. This study provided a new approach for in vitro investigation and validated this biomagnetic technique as a tool for quality control for pharmaceutical industry. Moreover, using ACB will also be possible to test these parameters in humans allowing to establish an in vitro/in vivo correlation (IVIVC). (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated, in vitro, the fracture resistance of human non-vital teeth restored with different reconstruction protocols. Material and methods: Forty human anterior roots of similar shape and dimensions were assigned to four groups (n=10), according to the root reconstruction protocol: Group I (control): non-weakened roots with glass fiber post; Group II: roots with composite resin by incremental technique and glass fiber post; Group III: roots with accessory glass fiber posts and glass fiber post; and Group IV: roots with anatomic glass fiber post technique. Following post cementation and core reconstruction, the roots were embedded in chemically activated acrylic resin and submitted to fracture resistance testing, with a compressive load at an angle of 45 degrees in relation to the long axis of the root at a speed of 0.5 mm/min until fracture. All data were statistically analyzed with bilateral Dunnett's test (alpha=0.05). Results: Group I presented higher mean values of fracture resistance when compared with the three experimental groups, which, in turn, presented similar resistance to fracture among each other. None of the techniques of root reconstruction with intraradicular posts improved root strength, and the incremental technique was suggested as being the most recommendable, since the type of fracture that occurred allowed the remaining dental structure to be repaired. Conclusion: The results of this in vitro study suggest that the healthy remaining radicular dentin is more important to increase fracture resistance than the root reconstruction protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behavior of the non-perturbative parts of the isovector-vector and isovector and isosinglet axial-vector correlators at Euclidean momenta is studied in the framework of a covariant chiral quark model with non-local quark-quark interactions. The gauge covariance is ensured with the help of the P-exponents, with the corresponding modification of the quark-current interaction vertices taken into account. The low- and high-momentum behavior of the correlators is compared with the chiral perturbation theory and with the QCD operator product expansion, respectively. The V-A combination of the correlators obtained in the model reproduces quantitatively the ALEPH and OPAL data on hadronic tau decays, transformed into the Euclidean domain via dispersion relations. The predictions for the electromagnetic pi(+/-) - pi(0) mass difference and for the pion electric polarizability are also in agreement with the experimental values. The topological susceptibility of the vacuum is evaluated as a function of the momentum, and its first moment is predicted to be chi'(0) approximate to (50 MeV)(2). In addition, the fulfillment of the Crewther theorem is demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that the Einstein-Hilbert, the Einstein-Palatini, and the Holst actions can be derived from the Quadratic Spinor Lagrangian (QSL), when the three classes of Dirac spinor fields, under Lounesto spinor field classification, are considered. To each one of these classes, there corresponds an unique kind of action for a covariant gravity theory. In other words, it is shown to exist a one-to-one correspondence between the three classes of non-equivalent solutions of the Dirac equation, and Einstein-Hilbert, Einstein-Palatini, and Holst actions. Furthermore, it arises naturally, from Lounesto spinor field classification, that any other class of spinor field-Weyl, Majorana, flagpole, or flag-dipole spinor fields-yields a trivial (zero) QSL, up to a boundary term. To investigate this boundary term, we do not impose any constraint on the Dirac spinor field, and consequently we obtain new terms in the boundary component of the QSL. In the particular case of a teleparallel connection, an axial torsion one-form current density is obtained. New terms are also obtained in the corresponding Hamiltonian formalism. We then discuss how these new terms could shed new light on more general investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a collective potential derived previously on the basis of the generator coordinate method with Skyrme interactions, we obtain values for the compression modulus of Ca-40 which are in good agreement with a recently obtained experimental value. Calculated values for the compression modulus for O-16 are also given. The procedure involved in the derivation of the collective potential is briefly reviewed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Gross-Pitaevskii equation for a Bose-Einstein condensate confined in an elongated cigar-shaped trap is reduced to an effective system of nonlinear equations depending on only one space coordinate along the trap axis. The radial distribution of the condensate density and its radial velocity are approximated by Gaussian functions with real and imaginary exponents, respectively, with parameters depending on the axial coordinate and time. The effective one-dimensional system is applied to a description of the ground state of the condensate, to dark and bright solitons, to the sound and radial compression waves propagating in a dense condensate, and to weakly nonlinear waves in repulsive condensate. In the low-density limit our results reproduce the known formulas. In the high-density case our description of solitons goes beyond the standard approach based on the nonlinear Schrodinger equation. The dispersion relations for the sound and radial compression waves are obtained in a wide region of values of the condensate density. The Korteweg-de Vries equation for weakly nonlinear waves is derived and the existence of bright solitons on a constant background is predicted for a dense enough condensate with a repulsive interaction between the atoms.