952 resultados para three-phase induction motor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The theory presented in this paper was primarily developed to give a physical interpretation for the instantaneous power flow on a three-phase induction machine, without a neutral conductor, on any operational state and may be extended to any three-phase load. It is a vectorial interpretation of the instantaneous reactive power theory presented by Akagi et al. Which, believe the authors, isn't enough developed and its physical meaning not yet completely understood. This vectorial interpretation is based on the instantaneous complex power concept defined by Torrens for single-phase, ac, steady-state circuits, and leads to a better understanding of the power phenomenon, particularly of the distortion power. This concept has been extended by the authors to three-phase systems, through the utilization of the instantaneous space vectors. The results of measurements of instantaneous complex power on a self-excited induction generator's terminals, during an over-load application transient, are presented for illustration. The compensation of reactive power proposed by Akagi is discussed and a new horizon for the theory application is opened.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering that the Brazilian energy source is based on hydroelectric power plants, every moment that it does not rain enough, we are likely to suffer power outage. Making the rational use of energy not only is wise, but also important for financial issues. The industrial sector is of great importance to Brazilian economic context, because it is one that creates more wealth and jobs. It should be noted that it is one of the sectors that consume more electricity. One of the most used equipment in industry is the three phase induction motor, which ends up providing significant waste of energy. For that reasons, studying three phase induction motors is important. One of the ways to evaluate the parameter of the three phase induction motor is using a dynamometer mechanic or electric. This work aims at further studies (and development) of electrodynamometer brake, a type of electrical dynamometer, that is the only one with reversible use. This means, it is possible to measure both the torque and the power transmitted by the electric motors, by the direct method and the indirect. Besides it allows greater stability in the imposition of charges, due to its nature of being able to regenerate the energy imparted by the engines being tested

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering that the Brazilian energy source is based on hydroelectric power plants, every moment that it does not rain enough, we are likely to suffer power outage. Making the rational use of energy not only is wise, but also important for financial issues. The industrial sector is of great importance to Brazilian economic context, because it is one that creates more wealth and jobs. It should be noted that it is one of the sectors that consume more electricity. One of the most used equipment in industry is the three phase induction motor, which ends up providing significant waste of energy. For that reasons, studying three phase induction motors is important. One of the ways to evaluate the parameter of the three phase induction motor is using a dynamometer mechanic or electric. This work aims at further studies (and development) of electrodynamometer brake, a type of electrical dynamometer, that is the only one with reversible use. This means, it is possible to measure both the torque and the power transmitted by the electric motors, by the direct method and the indirect. Besides it allows greater stability in the imposition of charges, due to its nature of being able to regenerate the energy imparted by the engines being tested

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dificuldade de controlo de um motor de indução, bem como o armazenamento de energia CC e posterior utilização como energia alternada promoveram o desenvolvimento de variadores de frequência e inversores. Assim, como projeto de tese de mestrado em Automação e Sistemas surge o desenvolvimento de um variador de frequência. Para elaboração do variador de frequência efetuou-se um estudo sobre as técnicas de modulação utilizadas nos inversores. A técnica escolhida e utilizada é a Sinusoidal Pulse Width Modulation (SPWM). Esta técnica baseia-se na modelação por largura de impulso (PWM), o qual é formado por comparação de um sinal de referência com um sinal de portadora de elevada frequência. Por sua vez, a topologia escolhida para o inversor corresponde a um Voltage Source Inverter (VSI) de ponte trifásica completa a três terminais. O desenvolvimento da técnica de modulação SPWM levou ao desenvolvimento de um modelo de simulação em SIMULINK, o qual permitiu retirar conclusões sobre os resultados obtidos. Na fase de implementação, foram desenvolvidas placas para o funcionamento do variador de frequência. Assim, numa fase inicial foi desenvolvida a placa de controlo, a qual contém a unidade de processamento e que é responsável pela atuação de Insulated Gate Bipolar Transistors (IGBTs). Para além disso, foi desenvolvida uma placa para proteção dos IGBTs (evitando condução simultânea no mesmo terminal) e uma placa de fontes isoladas para alimentação dos circuitos e para atuação dos IGBTs. Ainda, foi desenvolvida a técnica de SPWM em software para a unidade de controlo e finalmente foi desenvolvida uma interface gráfica para interação com o utilizador. A validação do projeto foi conseguida através da variação da velocidade do motor de indução trifásico. Para isso, este foi colocado a funcionar a diversas frequências de funcionamento e a diferentes amplitudes. Para além disso, o seu funcionamento foi também validado utilizando uma carga trifásica equilibrada de 3 lâmpadas de forma a ser visualizada a variação de frequência e variação de amplitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the variable structure adaptive pole placement controller (VS-APPC) robustness and performance are evaluated and this algorithm is applied in a motor control system. The controller robustness evaluation will be done through simulations, where will be introduced in the system the following adversities: time delay, actuator response boundeds, disturbances, parametric variation and unmodeled dynamics. The VS-APPC will be compared with PI control, pole placement control (PPC) and adaptive pole placement controller (APPC). The VS-APPC will be simulated to track a step and a sine reference. It will be applied in a three-phase induction motor control system to track a sine signal in the stator reference frame. Simulation and experimental results will prove the efficiency and robustness of this control strategy

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a diagnosis faults system (rotor, stator, and contamination) of three-phase induction motor through equivalent circuit parameters and using techniques patterns recognition. The technology fault diagnostics in engines are evolving and becoming increasingly important in the field of electrical machinery. The neural networks have the ability to classify non-linear relationships between signals through the patterns identification of signals related. It is carried out induction motor´s simulations through the program Matlab R & Simulink R , and produced some faults from modifications in the equivalent circuit parameters. A system is implemented with multiples classifying neural network two neural networks to receive these results and, after well-trained, to accomplish the identification of fault´s pattern

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are two main approaches for using in adaptive controllers. One is the so-called model reference adaptive control (MRAC), and the other is the so-called adaptive pole placement control (APPC). In MRAC, a reference model is chosen to generate the desired trajectory that the plant output has to follow, and it can require cancellation of the plant zeros. Due to its flexibility in choosing the controller design methodology (state feedback, compensator design, linear quadratic, etc.) and the adaptive law (least squares, gradient, etc.), the APPC is the most general type of adaptive control. Traditionally, it has been developed in an indirect approach and, as an advantage, it may be applied to non-minimum phase plants, because do not involve plant zero-pole cancellations. The integration to variable structure systems allows to aggregate fast transient and robustness to parametric uncertainties and disturbances, as well. In this work, a variable structure adaptive pole placement control (VS-APPC) is proposed. Therefore, new switching laws are proposed, instead of using the traditional integral adaptive laws. Additionally, simulation results for an unstable first order system and simulation and practical results for a three-phase induction motor are shown

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paperwork presents a Pulse Width Modulation (PWM) speed controller for an electric mini-baja-type car. A battery-fed 1-kW three-phase induction motor provides the electric vehicle traction. The open-loop speed control is implemented with an equal voltage/frequency ratio, in order to maintain a constant amount of torque on all velocities. The PWM is implemented by a low-cost 8-bit microcontroller provided with optimized ROM charts for distinct speed value implementations, synchronized transition between different charts and reduced odd harmonics generation. This technique was implemented using a single passenger mini-baja vehicle, and the essays have shown that its application resulted on reduced current consumption, besides eliminating mechanical parts. Copyright © 2007 by ABCM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large electric motors require greater care when driving, especially during continuous operation since they are part of day-to-day manufacturing sector, acting essentially to ensure that no damage occurs to the production process and equipment that are part of the same system. This work includes the analysis of electrical protection in a system comprised of a three phase induction motor driven by a frequency converter as well as an analysis of the functions of a multifunction electronic relay. It is presented a comparison between the existing functions in a converter and a relay and a real case is described in order to exemplify the use of an electric motor and features that are aimed at their protection, and the system in which it is inserted. Based on the results, it is of great importance in this field of performance studies, generating relevant results, which may be exposed in order to unify into a single document, different sources of information that are arranged randomly, improve utilization motor and extend the life of equipment forming part of the electrical installation

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the three-phase induction motor by a thermal analysis of its operation, under the gaze of the standards of the Brazilian Association of Technical Standards that deal with working arrangements (operating cycles) defined by appropriate tests and for each use of the motor basis of this study, emphasizing especially the fact of the first three cycles are the cycles with greater possibilities of use for scaling a three-phase induction motor for the main industrial processes, will also be made an analysis of the reasons why the three-phase induction motors have a loss of power at altitudes above 1000 m above sea level and some methods of how to define how a three phase induction motor can be used in one of the first three working arrangements