779 resultados para portable altar
Resumo:
Two longitudinal experiments were conducted exploring emotional experiences with PIDs over six months including media and medial Portable Interactive Devices (PIDs). Results identifying the impact of negative social and personal interactions on the overall emotional experience as well as different task categories (Features, Functional, Mediation and Auxiliary) and their corresponding emotional responses have previously been reported [2,3,4,5]. This paper builds on these findings and presents the Designing for Evolving Emotional Experience (DE3) framework promoting positive (and deals with negative) emotional experiences with PIDs including a set of principles to better understand emotional experiences. To validate the DE3 framework a preliminary trial was conducted with five practicing industrial designers. The trial required them to consider initial design concepts using the DE3 framework followed by a questionnaire asking about their use of the framework for concept development. The trial aimed to analyse the effectiveness, efficiency and usefulness of the framework in assisting in the development of initial concepts for PIDs taking into account emotional experiences. Common themes regarding the framework are outlined including the ease of use, the effectiveness in focusing on the personal and social contexts and positive ratings regarding its use. Overall the feedback from the preliminary trial was encouraging with responses suggesting that the framework was accessible, rated highly and most importantly permitted designers to consider emotional experiences during concept development. The paper concludes with a discussion regarding the future development of the DE3 framework and the potential implications to design theory and the design discipline.
Resumo:
This research has developed an innovative road safety barrier system that will enhance roadside safety. In doing so, the research developed new knowledge in the field of road crash mitigation for high speed vehicle impact involving plastic road safety barriers. This road safety barrier system has the required feature to redirecting an errant vehicle with limited lateral displacement. Research was carried out using dynamic computer simulation technique support by experimental testing. Future road safety barrier designers may use the information in this research as a design guideline to improve the performance and redirectional capability of the road safety barrier system. This will lead to better safety conditions on the roadways and potentially save lives.
Resumo:
Portable water-filled barriers (PWFBs) are roadside appurtenances that are used to prevent errant vehicles from penetrating into temporary construction zones on roadways. A numerical model of the composite PWFB, consisting of a plastic shell, steel frame, water and foam was developed and validated against results from full scale experimental tests. This model can be extended to larger scale impact cases, specifically ones that include actual vehicle models. The cost-benefit of having a validated numerical model is significant and this allows the road barrier designer to conduct extensive tests via numerical simulations prior to standard impact tests Effects of foam cladding as additional energy absorption material in the PWFB was investigated. Different types of foam were treated and it was found that XPS foam was the most suitable foam type. Results from this study will aid PWFB designers in developing new generation of roadside structures which will provide enhanced road safety.
SWIRLnet : portable anemometer network for wind speed measurements of land-falling tropical cyclones
Resumo:
Wind speed measurement systems are sparse in the tropical regions of Australia. Tropical cyclone wind speeds impacting communities are often ‘guestimated’ from analyzing damaged structures. A re-locatable anemometer system is required to enable measurements of wind speeds. This paper discusses design criteria of the tripods and tie down system, proposed deployment of the anemometers, instrumentation, and data logging. Preliminary assessment of the anemometer response indicates a reliable system for 1 second response, however, it is noted that the Australian building code and wind loading standard uses a moving average time of approximately 0.2 seconds for its wind speed design criteria.
Resumo:
Wind speed measurement systems are sparse in the tropical regions of Australia. Given this, tropical cyclone wind speeds impacting communities are seldom measured and often only ‘guestimated’ by analysing the extent of damage to structures. In an attempt to overcome this dearth of data, a re-locatable network of anemometers to be deployed prior to tropical cyclone landfall is currently being developed. This paper discusses design criteria of the network’s tripods and tie down system, proposed deployment of the anemometers, instrumentation and data logging. Preliminary assessment of the anemometer response indicates a reliable system for measuring the spectral component of wind with frequencies of approximately 1 Hz. This system limitation highlights an important difference between the capabilities of modern instrumentation and that of the Dines anemometer (around 0.2 seconds) that was used to develop much of the design criteria within the Australian building code and wind loading standard.
Resumo:
The use of Portable Medical Devices (PMDs) has become increasingly widespread over the last few years. A combination of factors; including advances in technology, the pressure to reduce public health costs and the desire to make health solutions accessible to a wider patient base are contributing to the growth in the PMD market. Design has a clear role to play in the current and future context of the PMD landscape. In this paper, we identify emerging trends in the design of PMDs; including changes in the form, purpose and mode of use, and explore how these trends are likely to fundamentally impact the nature of healthcare and the patient experience from an experience design perspective. We conclude by identifying a research opportunity for design within the healthcare and PMD context.
Resumo:
Portable, water filled road safety barriers are used to provide protection and reduce the potential hazard due to errant vehicles in areas where the road conditions change frequently (e.g. near road work sites). As part of an effort to reduce excessive working widths typical of these systems, a study was conducted to assess the effectiveness of introducing polymeric foam filled panels into the design. Surrogate impact tests of a design typical of such as barrier system were conducted utilising a pneumatically powered horizontal impact testing machine up to impact energies of 7.40 kJ. Results of these tests are utilised to examine the barrier behaviour, in addition to being used to validate a couple FE/SPH model of the barrier system. Once validated, the FE/SPH model it utilised as the basis for a parametric study into the efficacy and effects of the inclusion of polymeric foam filled panels on the performance of portable water filled road safety barriers. It was found that extruded polystyrene foam functioned well, with a greater thickness of the foam panel significantly reducing the impacting body velocity as the barrier began to translate.
Resumo:
Portable water-filled barriers (PWFB) are roadside structures used to enhance safety at roadside work-zones. Ideally, a PWFB system is expected to protect persons and objects behind it and redirect the errant vehicle. The performance criteria of a road safety barrier system are (i) redirection of the vehicle after impact and (ii) lateral deflection within allowable limits. Since its inception, the PWFB has received criticism due to its underperformance compared to the heavier portable concrete barrier. A new generation composite high energy absorbing road safety barrier was recently developed by the authors.
Resumo:
Adverse health effects caused by worker exposure to ultrafine particles have been detected in recent years. The scientific community focuses on the assessment of ultrafine aerosols in different microenvironments in order to determine the related worker exposure/dose levels. To this end, particle size distribution measurements have to be taken along with total particle number concentrations. The latter are obtainable through hand-held monitors. A portable particle size distribution analyzer (Nanoscan SMPS 3910, TSI Inc.) was recently commercialized, but so far no metrological assessment has been performed to characterize its performance with respect to well-established laboratory- based instruments such as the scanning mobility particle sizer (SMPS) spectrometer. The present paper compares the aerosol monitoring capability of the Nanoscan SMPS to the laboratory SMPS in order to evaluate whether the Nanoscan SMPS is suitable for field experiments designed to characterize particle exposure in different microenvironments. Tests were performed both in a Marple calm air chamber, where fresh diesel particulate matter and atomized dioctyl phthalate particles were monitored, and in microenvironments, where outdoor, urban, indoor aged, and indoor fresh aerosols were measured. Results show that the Nanoscan SMPS is able to properly measure the particle size distribution for each type of aerosol investigated, but it overestimates the total particle number concentration in the case of fresh aerosols. In particular, the test performed in the Marple chamber showed total concentrations up to twice those measured by the laboratory SMPS—likely because of the inability of the Nanoscan SMPS unipolar charger to properly charge aerosols made up of aggregated particles. Based on these findings, when field test exposure studies are conducted, the Nanoscan SMPS should be used in tandem
Resumo:
Isolating, purifying, and identifying proteins in complex biological matrices is often difficult, time consuming, and unreliable. Herein we describe a rapid screening technique for proteins in biological matrices that combines selective protein isolation with direct surface enhanced Raman spectroscopy (SERS) detection. Magnetic core gold nanoparticles were synthesised, characterised, and subsequently functionalized with recombinant human erythropoietin (rHuEPO)-specific antibody. The functionalized nanoparticles were used to capture rHuEPO from horse blood plasma within 15 minutes. The selective binding between the protein and the functionalized nanoparticles was monitored by SERS. The purified protein was then released from the nanoparticles’ surface and directly spectroscopically identified on a commercial nanopillar SERS substrate. ELISA independently confirmed the SERS identification and quantified the released rHuEPO. Finally, the direct SERS detection of the extracted protein was successfully demonstrated for in-field screening by a handheld Raman spectrometer within 1 minute sample measurement time.
Resumo:
People in many countries are affected by fluorosis owing to the high levels of fluoride in drinking water. An inexpensive method for estimating the concentration of the fluoride ion in drinking water would be helpful in identifying safe sources of water and also in monitoring the performance of defluoridation techniques. For this purpose, a simple, inexpensive, and portable colorimeter has been developed in the present work. It is used in conjunction with the SPADNS method, which shows a color change in the visible region on addition of water containing fluoride to a reagent solution. Groundwater samples were collected from different parts of the state of Karnataka, India and analysed for fluoride. The results obtained using the colorimeter and the double beam spectrophotometer agreed fairly well. The costs of the colorimeter and of the chemicals required per test were about Rs. 250 (US$ 5) and Rs. 2.5 (US$ 0.05), respectively. In addition, the cost of the chemicals required for constructing the calibration curve was about Rs. 15 (US$ 0.3). (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A microchip thermocycler, fabricated from silicon and Pyrex #7740 glass, is described. Usual resistive heating has been replaced by induction heating, leading to much simpler fabrication steps. Heating and cooling rates of 6.5 and 4.2 degreesC/s, respectively have been achieved, by optimising the heater dimensions and heating frequency (similar to200 kHz). Four devices are mounted on a heater, resulting in low power consumption (similar to 1.4 W per device on the average). Using simple on-off electronic temperature control, a temperature stability within -0.2 degreesC is achieved. Features such as induction heating, good temperature control, battery operation, and low power consumption make the device suitable for portable applications, particularly in polymerase chain reaction (PCR) systems. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
In this paper studies were carried out on two compact electric discharge plasma sources for controlling nitrogen oxides (NOX) emission in diesel engine exhaust. The plasma sources consist of an old television flyback transformer to generate high frequency high voltage ac (HVAC) and an automobile ignition coil to generate the high voltage pulses (HV Pulse). The compact plasma sources are aimed at retrofitting the existing catalytic converters with electric discharge assisted cleaning technique. To enhance NOX removal efficiency cascaded plasma-adsorbent technique has been used. Studies were reported at different flow rates and load conditions of the diesel engine.