888 resultados para GLUCOSE MONITORING-SYSTEM
Resumo:
AIM: In type 1 diabetic patients (T1DM), nocturnal hypoglycaemias (NH) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in T1DM, the best SMBG time to predict NH, the relationship between morning hyperglycaemia and NH (Somogyi phenomenon) and the utility of CGMS to reduce NH. METHODS: Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluation, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. RESULTS: The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR=2.37, P=0.001), while a single measure < or =4 mmol/l at 3-hour had a sensitivity of 43% (OR=4.60, P<0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR=3.95, P<0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P<0.001). CONCLUSION: NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
The goal of this work was to move structural health monitoring (SHM) one step closer to being ready for mainstream use by the Iowa Department of Transportation (DOT) Office of Bridges and Structures. To meet this goal, the objective of this project was to implement a pilot multi-sensor continuous monitoring system on the Iowa Falls Arch Bridge such that autonomous data analysis, storage, and retrieval can be demonstrated. The challenge with this work was to develop the open channels for communication, coordination, and cooperation of various Iowa DOT offices that could make use of the data. In a way, the end product was to be something akin to a control system that would allow for real-time evaluation of the operational condition of a monitored bridge. Development and finalization of general hardware and software components for a bridge SHM system were investigated and completed. This development and finalization was framed around the demonstration installation on the Iowa Falls Arch Bridge. The hardware system focused on using off-the-shelf sensors that could be read in either “fast” or “slow” modes depending on the desired monitoring metric. As hoped, the installed system operated with very few problems. In terms of communications—in part due to the anticipated installation on the I-74 bridge over the Mississippi River—a hardline digital subscriber line (DSL) internet connection and grid power were used. During operation, this system would transmit data to a central server location where the data would be processed and then archived for future retrieval and use. The pilot monitoring system was developed for general performance evaluation purposes (construction, structural, environmental, etc.) such that it could be easily adapted to the Iowa DOT’s bridges and other monitoring needs. The system was developed allowing easy access to near real-time data in a format usable to Iowa DOT engineers.
Resumo:
Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.
Resumo:
Työ sisältää ohjaislaitteiston vertailun ja valinnan rinnakkaisrakenteista robottia varten sekä kunnonvalvontajärjestelmän periaatteiden laadinnan kyseistä robottia varten. Ohjauslaitteisto sisältää teollisuustietokoneen sekä kenttäväylän. Sekä tietokoneesta että väylästä on teoriaosuus ja yksityiskohtaisempi valintaosuus. Teoriaosuudessa selitetään tarkemmin laitteiden toimintaperiaatteista. Valintaosuudessa kerrotaanmiksi jokin tietty laite on valittu käytettäväksi robotin ohjauksessa. Kunnonvalvontateoria ja rinnakkaisrakenteisen robotin kunnonvalvonnan keinot ovat työn toinen osa. Teoriaosa sisältää yleisluonteisen selvityksen vikaantumisesta ja valvonnasta. Erikoisrobotin kunnonvalvonnan keinot esitetään työssä tietyssä järjestyksessä. Ensin esitetään mahdolliset vikatilanteet. Toisessa kohdassa havainnollistetaan vikojen havaitseminen.
Resumo:
Tässä diplomityössä esitellään ohjelmistotestauksen ja verifioinnin yleisiä periaatteita sekä käsitellään tarkemmin älypuhelinohjelmistojen verifiointia. Työssä esitellään myös älypuhelimissa käytettävä Symbian-käyttöjärjestelmä. Työn käytännön osuudessa suunniteltiin ja toteutettiin Symbian-käyttöjärjestelmässä toimiva palvelin, joka tarkkailee ja tallentaa järjestelmäresurssien käyttöä. Verifiointi on tärkeä ja kuluja aiheuttava tehtävä älypuhelinohjelmistojen kehityssyklissä. Kuluja voidaan vähentää automatisoimalla osa verifiointiprosessista. Toteutettu palvelin automatisoijärjestelmäresurssien tarkkailun tallentamalla tietoja niistä tiedostoon testien ajon aikana. Kun testit ajetaan uudestaan, uusia tuloksia vertaillaan lähdetallenteeseen. Jos tulokset eivät ole käyttäjän asettamien virherajojen sisällä, siitä ilmoitetaan käyttäjälle. Virherajojen ja lähdetallenteen määrittäminen saattaa osoittautua vaikeaksi. Kuitenkin, jos ne määritetään sopivasti, palvelin tuottaa hyödyllistä tietoa poikkeamista järjestelmäresurssien kulutuksessa testaajille.
Resumo:
Container Handling Equipment Monitoring System (CHEMS) is a system developed by Savcor One Oy. CHEMS measures important information for container ports performance and produces performance indicators. The aim of this thesis was to clarify performance measurement contents to Savcor and to develop, as an example, performance measures to Steveco Oy's container operations. The theoretical part of the thesis clarifies performance measurement and which of its components are important to container port. Performance measurement and measures are presented from the operational level's point of view, in which CHEMS is planned to aim. The theory of development process of performance measures is introduced at the end of the theoretical part. To make sure that performance measures are efficiently used, Steveco Oy's performance measures are developed in cooperation with the users. The measurement in operational level is continuous and the results must be reacted asquickly as possible. CHEMS is very suitable to continuous measurement and to produce real time-measures of container operations which are hard to get any otherway.
Resumo:
In the drilling processes and especially deep-hole drilling process, the monitoring system and having control on mechanical parameters (e.g. Force, Torque,Vibration and Acoustic emission) are essential. The main focus of this thesis work is to study the characteristics of deep-hole drilling process, and optimize the monitoring system for controlling the process. The vibration is considered as a major defect area of the deep-hole drilling process which often leads to breakage of the drill, therefore by vibration analysis and optimizing the workpiecefixture, this area is studied by finite element method and the suggestions are explained. By study on a present monitoring system, and searching on the new sensor products, the modifications and recommendations are suggested for optimize the present monitoring system for excellent performance in deep-hole drilling process research and measurements.
Resumo:
Työn tarkoituksena oli suunnitella kunnonvalvontajärjestelmä kahdelle lasivillan tuotantolinjalle. Suunnitteluprosessin lisäksi työssä on esitelty erilaisia kunnonvalvontamenetelmiä. Työn alussa on kerrottu erilaisista kunnonvalvontamenetelmistä, joilla voidaan seurata erilaisten laitteiden ja koneiden toimintakuntoa.Erityisesti työssä on tarkasteltu teollisuudessa yleistyviä kunnonvalvonnan värähtelymittauksia. Työssä suunniteltu kunnonvalvontajärjestelmä perustuu viiteen eri menetelmään, jotka ovat värähtelymittaus, lämpötilanmittaus lämpökameralla, lämpötilanmittaus kannettavalla mittarilla, kuuntelu elektronisella stetoskoopilla ja pyörivien osien kunnontarkkailu stroboskoopilla. Kunnonvalvontajärjestelmän suunnittelu on tehty useassa eri vaiheessa. Ensin työssä on kartoitettu tuotannon kannalta tärkeimmät laitteet ja niiden mahdolliset vikaantumistavat. Seuraavaksi on valittu sopivat kunnonvalvontamenetelmät ja tehty mittaussuunnitelma, jossa on esitetty eri laitteille suoritettavat mittaukset ja mittausten aikavälit.Lopuksi työssä on esitelty muutama esimerkkitapaus kunnonvalvontamenetelmien käytöstä sekä kerrottu mahdollisista tulevaisuuden kehitysmahdollisuuksista.
Resumo:
Peer-reviewed
Resumo:
Environmental threats are growing nowadays, they became global issues. People around the world try to face these issues by two means: solving the current affected environs and preventing non-affected environs. This thesis describes the design, implementation, and evaluation of online water quality monitoring system in Lake Saimaa, Finland. The water quality in Lake Saimaa needs to be monitored in order to provide responsible bodies with valuable information which allows them to act fast in order to prevent any negative impact on the lake's environment. The objectives were to design a suitable system, implement the system in Lake Saimaa, and then to evaluate the applicability and reliability of such systems for this environment. The needs for the system were first isolated, and then the design, needed modifications, and the construction of the system took place. After that was the testing of the system in Lake Saimaa in two locations nearby Mikkeli city. The last step was to evaluate the whole system. The main results were that the application of online water quality monitoring systems in Lake Saimaa can benefit of many advantages such as reducing the required manpower, time and running costs. However, the point of unreliability of the exact measured values of some parameters is still the drawback of such systems which can be developed by using more advanced equipments with more sophisticated features specifically for the purpose of monitoring in the predefined location.
Resumo:
Recent advances in Information and Communication Technology (ICT), especially those related to the Internet of Things (IoT), are facilitating smart regions. Among many services that a smart region can offer, remote health monitoring is a typical application of IoT paradigm. It offers the ability to continuously monitor and collect health-related data from a person, and transmit the data to a remote entity (for example, a healthcare service provider) for further processing and knowledge extraction. An IoT-based remote health monitoring system can be beneficial in rural areas belonging to the smart region where people have limited access to regular healthcare services. The same system can be beneficial in urban areas where hospitals can be overcrowded and where it may take substantial time to avail healthcare. However, this system may generate a large amount of data. In order to realize an efficient IoT-based remote health monitoring system, it is imperative to study the network communication needs of such a system; in particular the bandwidth requirements and the volume of generated data. The thesis studies a commercial product for remote health monitoring in Skellefteå, Sweden. Based on the results obtained via the commercial product, the thesis identified the key network-related requirements of a typical remote health monitoring system in terms of real-time event update, bandwidth requirements and data generation. Furthermore, the thesis has proposed an architecture called IReHMo - an IoT-based remote health monitoring architecture. This architecture allows users to incorporate several types of IoT devices to extend the sensing capabilities of the system. Using IReHMo, several IoT communication protocols such as HTTP, MQTT and CoAP has been evaluated and compared against each other. Results showed that CoAP is the most efficient protocol to transmit small size healthcare data to the remote servers. The combination of IReHMo and CoAP significantly reduced the required bandwidth as well as the volume of generated data (up to 56 percent) compared to the commercial product. Finally, the thesis conducted a scalability analysis, to determine the feasibility of deploying the combination of IReHMo and CoAP in large numbers in regions in north Sweden.
Resumo:
The value that the customer perceives from a supplier’s offering, impacts customer’s decision making and willingness to pay at the time of the purchase, and the overall satisfaction. Thus, for a business supplier, it is critical to understand their customers’ value perceptions. The objective of this thesis is to understand what measurement and monitoring system customers value, by examining their key purchasing criteria and perceived benefits. Theoretical part of this study consists on reviewing relevant literature on organizational buying behavior and customer perceived value. This study employs a qualitative interview research method. The empirical part of this research consisted of conducting 20 in-depth interviews with life science customers in USA and in Europe. Quality and technical features are the most important purchasing criteria, while product-related benefits seem to be the most important perceived benefits. At the marketing of the system, the emphasis should be at which regulations the system complies with, references of supplier’s prior experience, the reliability and usability of the system, and total costs. The benefits that should be emphasized are the better control of customer’s process, and the proof of customer’s product quality
Resumo:
Corrosion represents one of the largest through life cost component of ships. Ship owners and operators recognize that combating corrosion significantly impacts the vessels’ reliability, availability and through life costs. Primary objective of this paper is to review various inspections, monitoring systems and life cycle management with respect to corrosion control of ships and to develop the concept of “Corrosion Health” (CH) which would quantify the extent of corrosion at any point of ships’ operational life. A system approach in which the ship structure is considered as a corrosion system and divided into several corrosion zones, with distinct characteristics, is presented. Various corrosion assessment criteria for assessment of corrosion condition are listed. A CH rating system for representation of complex corrosion condition with a numeric number along with recommendations for repair/maintenance action is also discussed