937 resultados para Derivative instruments
Resumo:
Air transport has become a vital component of the global economy. However, greenhouse-gas emissions from this sector have a significant impact on global climate, being responsible for over 3.5% of all anthropogenic radiative forcing. Also, the accrued visibility of aircraft emissions greatly affects the public image of the industry. In this context, incentive-based regulations, in the form of price or quantity controls, can be envisaged as alternatives to mitigate these emissions. The use of environmental charges in air transport, and the inclusion of the sector in the European Union Emissions Trading Scheme (EU ETS), are considered under a range of scenarios. The impacts of these measures on demand are estimated, and results suggest that they are likely to be minimal-mainly due to the high willingness to pay for air transport. In particular, in the EU ETS scenario currently favoured by the EU, demand reductions are less than 2%. This may not be true in the longer run, for short trips, or if future caps become more stringent. Furthermore, given current estimates of the social Cost Of CO2 as well as typical EU ETS prices, supply-side abatement would be too costly to be encouraged by these policies in the short term. The magnitude of aviation CO2 emissions in the EU is estimated, both in physical and monetary terms; the results are consistent with Eurocontrol estimates and, for the EU-25, the total social cost of these emissions represents only 0.03% of the region`s GDP. It is concluded that the use of multisector policies, such as the EU ETS, is unsuitable for curbing emissions from air transport, and that stringent emission charges or an isolated ETS would be better instruments. However, the inclusion of aviation in the EU ETS has advantages under target-oriented post-2012 scenarios, such as policy-costs dilution, certainty in reductions, and flexibility in abatement allocation. This solution is also attractive to airlines, as it would improve their public image but require virtually no reduction of their own emissions, as they would be fully capable of passing on policy costs to their customers.
Resumo:
This research aimed at determining spectrophotometrically (290 to 320nm) the in vitro Sun Protection Factor (SPF) of sunscreens developed with rutin (R) or succinate rutin (SR), in association or not with UVB filter. Formulations were developed based on phosphate-base O/W emulsions, with (B) or not (A) the presence of polyacrylamide/C13-14 isoparaffin/laureth-7 (PIL), in accordance with the following associations: (a) control; (b) 1.0 % SR; (c) 0.1 % R; (d) 7.5 % ethylhexyl methoxycinnamate (EHMC); (e) 7.5 % EHMC + 0.1 % RS; (0 7.5 % EHMC + 0.1 % R. It was verified a statistical significative elevation of the SPF from 13.93 +/- 0.02 (Af) to 16.63 +/- 0.27 (Bf) and also in relation to 15.53 +/- 0.14 (Bd). According to the results, the EHMC had distinct behavior depending on the presence of bioactive substance and viscosity agent, thus, rutin obtained better profile as a SPF booster in these experimental conditions with the presence of PIL.
Resumo:
New rapid first-derivative spectrophotometric (UVDS) and a stability-indicating high performance liquid chromatographic (HPLC) methods were developed, validated and successfully applied in the analysis of loratadine (LT) in tablets and syrups. In the UVDS method, 0.1 M HCl was used as solvent. The measurements were made at 312.4 nm in the first order derivative spectra. The HPLC method was carried out on a RP-18 column with a mobile phase composed of methanol-water-tetrahydrofuran (50:30:20, v/v/v). UV detection was made at 247 nm. For HPLC methods the total analysis time was <3min, adequate for routine quality control of tablets and syrups containing loratadine.
Resumo:
A stability-indicating high-performance liquid chromatographic (HPLC) and a second-order derivative spectrophotometric (UVDS) analytical methods were validated and compared for determination of simvastatin in tablets. The HPLC method was performed with isocratic elution using a C18 column and a mobile phase composed of methanol:acetonitrile:water (60:20:20, v/v/v) at a flow rate of 1.0 ml/min. The detection was made at 239 nm. In UVDS method, methanol and water were used in first dilution and distilled water was used in consecutive dilutions and as background. The second-order derivative signal measurement was taken at 255 nm. Analytical curves showed correlation coefficients > 0.999 for both methods. The quantitation limits (QL) were 2.41 mu g/ml for HPLC and 0.45 mu g/ml for UVDS, respectively. Intra and inter-day relative standard deviations were < 2.0 %. Statistical analysis with t- and F-tests are not exceeding their critical values demonstrating that there is no significant difference between the two methods at 95 % confidence level.
Resumo:
High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.
Resumo:
The viridins like demethoxyviridin (Dmv) and wortmannin (Wm) are nanomolar inhibitors of the PI3 kinases, a family of enzymes that play key roles in a host of regulatory processes. Central to the use of these compounds to investigate the role of PI3 kinase in biological systems, or as scaffolds for drug development, are the interrelated issues of stability, chemical reactivity, and bioactivity as inhibitors of PI3 kinase. We found that Dmv was an even more potent inhibitor of PI3 kinase than Wm. However, Dmv was notably less stable than Wm in PBS, with a half-life of 26 min versus Wm`s half-life of 3470 min. Dmv, like Wm, disappeared in culture media with a half-life of less than 1 min. To overcome Dmv`s instability, it was esterified at the C1 position, and then reacted with glycine at the C20 position. The resulting Dmv derivative, termed SA-DmvC20-Gly had a half-life of 218 min in PBS and 64 min in culture media. SA-DmvC20-Gly underwent an exchange reaction at the C20 position with N-acetyl lysine in a manner similar to a WmC20 derivative, WmC20-Proline. SA-DmvC20-Gly inhibited PI3 kinase with an IC(50) of 44 nM, compared to Wm`s IC(50) of 12 nM. These results indicate that the stability of Dmv can be manipulated by reactions at the C1 and C20 positions, while substantially maintaining its ability to inhibit PI3 kinase. Our results indicate it may be possible to obtain stabilized Dmv derivatives for use as PI3 kinase inhibitors in biological systems. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This was an early pre-Catalyst collaboration about developing reflexivity in student engineers. It was funded by (then) CUTSD.
Resumo:
In recent years there has been a growing recognition that many people with drug or alcohol problems are also experiencing a range of other psychiatric and psychological problems. The presence of concurrent psychiatric or psychological problems is likely to impact on the success of treatment services. These problems vary greatly, from undetected major psychiatric illnesses that meet internationally accepted diagnostic criteria such as those outlined in the Diagnostic and Statistical Manual (DSM-IV) of the American Psychiatric Association (1994), to less defined feelings of low mood and anxiety that do not meet diagnostic criteria but nevertheless impact on an individual’s sense of wellbeing and affect their quality of life.
Resumo:
The development of Australian forms of the Childhood Asthma Questionnaires (CAQs) is reported. Focus group methods and psychometric analyses were used to establish the conceptual, semantic and technical equivalence of these forms with the UK versions. Both versions also provide for data collection from non-asthmatic youngsters. The internal consistency was found to be acceptable (Cronbach's alpha 0.52-0.90) and the health-related quality of life (HRQoL) scores were found to vary with asthma severity (p < 0.05). Comparison with the UK data revealed that the non-asthmatic scores were higher for Australian than British children (p < 0.001) but that the scores for children with asthma did not differ between the two countries. It was only In the Australian sample that the group with asthma reported impaired HRQoL when compared to their healthy peers. These findings were interpreted in the context of cultural expectations of life quality and conclusions are presented regarding the importance of the gap between experience and expectations. The difficulties raised by the developmental and cultural issues inherent in paediatric HRQoL research were discussed. Qual. Life Res. 7:409-419 (C) 1998 Kluwer Academic Publishers
Resumo:
This naphthalene diimide derivative, DC18, forms highly conjugated semiconducting stacked assemblies over electrodes after electrochemical conditioning. These molecular materials are very efficient towards electrochemical photoreduction of oxygen under visible light.
Resumo:
Gas-phase dissociation pathways of deprotonated 1,4-naphthoquinone (NQ) derivatives have been investigated by electrospray ionization tandem mass spectrometry (ESI-MS/MS). The major decomposition routes have been elucidated on the basis of quantum chemical calculations at the B3LYP/6-31+G(d,p) level. Deprotonation sites have been indicated by analysis of natural charges and gas-phase acidity. NQ anions underwent an interesting reaction under collision-induced dissociation conditions, which resulted in the radical elimination of the lateral chain, in contrast with the even-electron rule. Possible pathways have been suggested, and their mechanisms have been elucidated on the basis of Gibbs energy and enthalpy values for the anions previously described at each pathway. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
One of the challenges in screening for dementia in developing countries is related to performance differences due to educational and cultural factors. This study evaluated the accuracy of single screening tests as well as combined protocols including the Mini-Mental State Examination (MMSE), Verbal Fluency animal category (VF), Clock Drawing test (CDT), and Pfeffer Functional Activities Questionnaire (PFAQ) to discriminate illiterate elderly with and without Alzheimer`s disease (AD) in a clinical sample. Cross-sectional study with 66 illiterate outpatients diagnosed with mild and moderate AD and 40 illiterate normal controls. Diagnosis of AD was based on NINCDS-ADRDA. All patients were submitted to a diagnostic protocol including a clinical interview based on the CAMDEX sections. ROC curves area analyses were carried out to compare sensitivity and specificity for the cognitive tests to differentiate the two groups (each test separately and in two by two combinations). Scores for all cognitive (MMSE, CDT, VF) and functional assessments (PFAQ) were significantly different between the two groups (p < 0.001). The best screening instruments for this sample of illiterate elderly were the MMSE and the PFAQ. The cut-off scores for the MMSE, VF, CDT, and PFAQ were 17.5, 7.5, 2.5, and 11.5, respectively. The most sensitive combination came from the MMSE and PFAQ (94.1%), and the best specificity was observed with the combination of the MMSE and CDT (89%). Illiterate patients can be successfully screened for AD using well-known screening instruments, especially in combined protocols.
Resumo:
Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 mu A/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). Results: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). Conclusions: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation. of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life. (J Endod 2010;36:1183-1186)
Resumo:
Introduction: The aim of this study was to assess the occurrence of apical root transportation after the use of Pro Taper Universal rotary files sizes 3 (F3) and 4 (F4). Methods: Instruments were worked to the apex of the original canal, always by the same operator. Digital subtraction radiography images were produced in buccolingual and mesiodistal projections. A total of 25 radiographs were taken from root canals of human maxillary first molars with curvatures varying from 23-31 degrees. Quantitative data were analyzed by intraclass correlation coefficient and Wilcoxon nonparametric test (P = .05). Results: Buccolingual images revealed a significantly higher degree of apical transportation associated with F4 instruments when compared with F3 instruments in relation to the original canal (Wilcoxon test, P = .007). No significant difference was observed in mesiodistal images (P = .492). Conclusions: F3 instruments should be used with care in curved canals, and F4 instruments should be avoided in apical third preparation of curved canals. (J Endod 2010;36:1052-1055)