863 resultados para Coagulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The infectious process starts with an initial contact between pathogen and host. We have previously demonstrated that Paracoccidioides brasiliensis conidia interact with plasma proteins including fibrinogen, which is considered the major component of the coagulation system. In this study, we evaluated the in vitro capacity of P. brasiliensis conidia to aggregate with plasma proteins and compounds involved in the coagulation system. We assessed the aggregation of P. brasiliensis conidia after incubation with human serum or plasma in the presence or absence of anticoagulants, extracellular matrix (ECM) proteins, metabolic and protein inhibitors, monosaccharides and other compounds. Additionally, prothrombin and partial thromboplastin times were determined after the interaction of P. brasiliensis conidia with human plasma. ECM proteins, monosaccharides and human plasma significantly induced P. brasiliensis conidial aggregation; however, anticoagulants and metabolic and protein inhibitors diminished the aggregation process. The extrinsic coagulation pathway was not affected by the interaction between P. brasiliensis conidia and plasma proteins, while the intrinsic pathway was markedly altered. These results indicate that P. brasiliensis conidia interact with proteins involved in the coagulation system. This interaction may play an important role in the initial inflammatory response, as well as fungal disease progression caused by P. brasiliensis dissemination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Rivaroxaban (RXA) is licensed for prophylaxis of venous thromboembolism after major orthopaedic surgery of the lower limbs. Currently, no test to quantify RXA in plasma has been validated in an inter-laboratory setting. Our study had three aims: to assess i) the feasibility of RXA quantification with a commercial anti-FXa assay, ii) its accuracy and precision in an inter-laboratory setting, and iii) the influence of 10mg of RXA on routine coagulation tests. METHODS: The same chromogenic anti-FXa assay (Hyphen BioMed) was used in all participating laboratories. RXA calibrators and sets of blinded probes (aim ii.) were prepared in vitro by spiking normal plasma. The precise RXA content was assessed by high-pressure liquid chromatography-tandem mass spectrometry. For ex-vivo studies (aim iii), plasma samples from 20 healthy volunteers taken before and 2 - 3hours after ingestion of 10mg of RXA were analyzed by participating laboratories. RESULTS: RXA can be assayed chromogenically. Among the participating laboratories, the mean accuracy and the mean coefficient of variation for precision of RXA quantification were 7.0% and 8.8%, respectively. Mean RXA concentration was 114±43μg/L .RXA significantly altered prothrombin time, activated partial thromboplastin time, factor analysis for intrinsic and extrinsic factors. Determinations of thrombin time, fibrinogen, FXIII and D-Dimer levels were not affected. CONCLUSIONS: RXA plasma levels can be quantified accurately and precisely by a chromogenic anti-FXa assay on different coagulometers in different laboratories. Ingestion of 10mg RXA results in significant alterations of both PT- and aPTT-based coagulation assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Activated protein C (APC) deC ciency is prevalent in severe sepsis and septic shock patients. The aim of the study was to relate the anticoagulation activity evaluated by APC with other coagulation parameters adjusted to 28-day mortality. Methods A cohort study of 150 critically ill adults. Age, sex, sources of infection and coagulation markers within 24< hours from severe sepsis or septic shock onset, deC ned according to Surviving Sepsis Campaign (SSC) criteria, were studied. We analyzed APC activity using a hemostasis laboratory analyzer (BCS® XP; Siemens). A descriptive and comparative statistical analysis was performed using SPSS version 15.0 (SPSS Inc., Chicago, IL, USA). Results We analyzed 150 consecutive episodes of severe sepsis (16%) or septic shock (84%) admitted to the UCI. The median age of the study sample was 64 (interquartile range (IQR): 22.30.001). See Figure 1. Conclusion Low levels of PC are associated with poor outcome and severity in severe sepsis, and it is well correlated with antithrombin III and INR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inhibition of coagulation factor XII (FXII) activity represents an attractive approach for the treatment and prevention of thrombotic diseases. The few existing FXII inhibitors suffer from low selectivity. Using phage display combined to rational design, we developed a potent inhibitor of FXII with more than 100-fold selectivity over related proteases. The highly selective peptide macrocycle is a promising candidate for the control of FXII activity in antithrombotic therapy and a valuable tool in hematology research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Laboratory utilization has steadily increased with a corresponding increase in overall costs; several authors have attempted to measure the impact of inappropriateness on clinical outcomes but data are insufficient. The aim of the study is to assess the cost of inappropriateness of test-ordering behaviour for second-level coagulation tests (hemorrhagic diathesisand thrombophilia). Methods. We reviewed all second-level coagulation testrequests received by our department during a six months period. Clinicians must fill out a specific order form for these kind of tests, containing all informations deemed necessary for the laboratory specialist to evaluatethe appropriateness of the request. We identified all inappropriate requests and counted the numbers and types of all coagulation tests that were not performed during the period. An analysis of the laboratory activity costs was done in order to calculate the global costof each test in our department and to estimate the savings achieved. Results. On a total of 1664 second-level coagulationtest requests, we estimated 150 as completely inappropriate. We found an overall of 295 inappropriate testswhich were not performed. This resulted in an economic saving of 20.000 euro in 6 months. Conclusions. The analysis of cost of our intervention shows the urgent need for a definite and sustained reduction in inappropriate requests of second-level coagulation tests. Even though we estimated only the economic aspect of inappropriate testing, this is also associated with the overuse of diagnostic tests which entailsthe risk of generating erroneous results with potentialnegative consequences on patients' health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coagulation factor V (FV) deficiency is characterised by variable bleeding phenotypes and heterogeneous mutations. To add new insights into the FV genotype-phenotype relationship, we characterised the R1698W change in the A3 domain, at the poorly investigated interface with the A2 domain. The FV R1698W mutation was responsible for a markedly reduced expression level (10% of FV-WT) and specific activity in thrombin generation (0.39). Interestingly, the FVa1698W showed rapid activity decay upon activation due to increased dissociation rate between the heavy and light chains. The importance of the size and charge of the residue at position 1698 was investigated by three additional recombinant mutants, FVR1698A, FVR1698Q, and FVR1698E. FVR1698A and FVR1698Q expression (30 and 45% of FV-WT), specific activity (both 0.57) and stability were all reduced. Noticeably, FVR1698E showed normal activity and stability despite poor expression (10% of FV-WT). These data indicate the essential role of R1698 for normal biosynthetic process and support local flexibility for positively or negatively charged residues to produce stable and functional A3-A2 domain interactions. Their experimental alteration produces a gradient of FV defects, which help to interpret the wide spectrum of phenotypes in FV-deficient patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A concentrate for bicarbonate haemodialysis acidified with citrate instead of acetate has been marketed in recent years. The small amount of citrate used (one-fifth of the concentration adopted in regional anticoagulation) protects against intradialyser clotting while minimally affecting the calcium concentration. The aim of this study was to compare the impact of citrate- and acetate-based dialysates on systemic haemodynamics, coagulation, acid-base status, calcium balance and dialysis efficiency. METHODS: In 25 patients who underwent a total of 375 dialysis sessions, an acetate dialysate (A) was compared with a citrate dialysate with (C+) or without (C) calcium supplementation (0.25 mmol/L) in a randomised single-blind cross-over study. Systemic haemodynamics were evaluated using pulse-wave analysis. Coagulation, acid-base status, calcium balance and dialysis efficiency were assessed using standard biochemical markers. RESULTS: Patients receiving the citrate dialysate had significantly lower systolic blood pressure (BP) (-4.3 mmHg, p < 0.01) and peripheral resistances (PR) (-51 dyne.sec.cm-5, p < 0.001) while stroke volume was not increased. In hypertensive patients there was a substantial reduction in BP (-7.8 mmHg, p < 0.01). With the C+ dialysate the BP gap was less pronounced but the reduction in PR was even greater (-226 dyne.sec.cm-5, p < 0.001). Analyses of the fluctuations in PR and of subjective tolerance suggested improved haemodynamic stability with the citrate dialysate. Furthermore, an increase in pre-dialysis bicarbonate and a decrease in pre-dialysis BUN, post-dialysis phosphate and ionised calcium were noted. Systemic coagulation activation was not influenced by citrate. CONCLUSION: The positive impact on dialysis efficiency, acid-base status and haemodynamics, as well as the subjective tolerance, together indicate that citrate dialysate can significantly contribute to improving haemodialysis in selected patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coagulation factor XIIIB polymorphism was studied by agarose isoelectric focusing and immunofixation in 592 unrelated individuals from Switzerland. The gene frequencies observed were: FXIIIB*1 = 0.769, FXIIIB*3 = 0.139, FXIIIB*2 = 0.085, FXIIIB*4 = 0.007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrombin is involved in mediating neuronal death in cerebral ischemia. We investigated its so far unknown mode of activation in ischemic neural tissue. We used an in vitro approach to distinguish the role of circulating coagulation factors from endogenous cerebral mechanisms. We modeled ischemic stroke by subjecting rat organotypic hippocampal slice cultures to 30-min oxygen (5%) and glucose (1 mmol/L) deprivation (OGD). Perinuclear activated factor X (FXa) immunoreactivity was observed in CA1 neurons after OGD. Selective FXa inhibition by fondaparinux during and after OGD significantly reduced neuronal death in the CA1 after 48 h. Thrombin enzyme activity was increased in the medium 24 h after OGD and this increase was prevented by fondaparinux suggesting that FXa catalyzes the conversion of prothrombin to thrombin in neural tissue after ischemia in vitro. Treatment with SCH79797, a selective antagonist of the thrombin receptor protease-activated receptor-1 (PAR-1), significantly decreased neuronal cell death indicating that thrombin signals ischemic damage via PAR-1. The c-Jun N-terminal kinase (JNK) pathway plays an important role in excitotoxicity and cerebral ischemia and we observed activation of the JNK substrate, c-Jun in our model. Both the FXa inhibitor, fondaparinux and the PAR-1 antagonist SCH79797, decreased the level of phospho-c-Jun Ser73. These results indicate that FXa activates thrombin in cerebral ischemia, which leads via PAR-1 to the activation of the JNK pathway resulting in neuronal death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Tankkimaidon juoksettumisominaisuuksien vaikutus Emmental-juuston määrään ja koostumukseen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The coagulation factor thrombin mediates ischemic neuronal deathand, at a low concentration, induces tolerance to ischemia.We investigated its modeof activation in ischemic neural tissue using an in vitro approach to distinguish therole of circulating coagulation factors from endogenous cerebral mechanisms. Wealso studied the signalling pathway downstream of thrombin in ischemia and afterthrombin preconditioning.Methods: Rat organotypic hippocampal slice cultures to 30 minute oxygen (5%)and glucose (1 mmol/L) deprivation (OGD).Results: Selective factor Xa (FXa) inhibition by fondaparinux during and afterOGD significantly reduced neuronal death in the CA1 after 48 hours. Thrombinactivity was increased in the medium 24 hours after OGD and this increasewas prevented by fondaparinux suggesting that FXa catalyzes the conversion ofprothrombin to thrombin in neural tissue after ischemia in vitro. Treatment withSCH79797, a selective antagonist of the thrombin receptor protease activatedreceptor-1 (PAR-1), significantly decreased neuronal cell death indicating thatthrombin signals ischemic damage via PAR-1. The JNK pathway plays an importantrole in cerebral ischemia and we observed activation of the JNK substrate,c-Jun in our model. Both the FXa inhibitor, fondaparinux and the PAR-1 antagonistSCH79797, decreased the level of phospho-c-Jun Ser73. After thrombin preconditioningc-Jun was activated by phosphorylation in the nuclei of neurons of the CA1.Treatment with a synthetic thrombin receptor agonist resulted in the same c-Junactivation profile and protection against subsequent OGD indicating that thrombinalso signals via PAR-1 and c-Jun in cell protection.Conclusion: These results indicate that FXa activates thrombin in cerebral ischemia,leading via PAR-1 to the activation of the JNK pathway resulting in neuronal death.Thrombin induced tolerance also involves PAR-1 and JNK, revealing commonfeatures in cell death and survival signalling.