800 resultados para Casting
Desenvolvimento de estruturas porosas tridimensionais por moldação por congelamento (Freeze-Casting)
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia de Materiais
Resumo:
A systematic study for the production of porous poly(vinylidene fluoride-trifluoroethylene), P(VDF-TrFE), films using solvent evaporation and non-solvent induced phase separation techniques is presented. Processing parameters such as copolymer volume fraction, solvent, preset exposure time to air before immersion, and non-solvent and temperature of the coagulation bath were varied and the corresponding sample morphology, hydrophobicity, thermal and mechanical properties were determined. Film morphologies including homogeneous pore distributions, micropores, microvoids, spherulites and non-porous films were obtained. The morphology variations strongly influence sample hydrophobicity and mechanical properties. All samples crystallize in the electroactive β-phase with a degree of crystallinity around 30 %.
Resumo:
Identification of the tensile constitutive behaviour of Fibre Reinforced Concrete (FRC) represents an important aspect of the design of structural elements using this material. Although an important step has been made with the introduction of guidance for the design with regular FRC in the recently published fib Model Code 2010, a better understanding of the behaviour of this material is still necessary, mainly for that with self-compacting properties. This work presents an experimental investigation employing Steel Fibre Self-Compacting Concrete (SFRSCC) to cast thin structural elements. A new test method is proposed for assessing the post-cracking behaviour and the results obtained with the proposed test method are compared with the ones resulted from the standard three-point bending tests (3PBT). Specimens extracted from a sandwich panel consisting of SFRSCC layers are also tested. The mechanical properties of SFRSCC are correlated to the fibre distribution by analysing the results obtained with the different tests. Finally, the stress-crack width constitutive law proposed by the fib Model Code 2010 is analysed in light of the experimental results.
Resumo:
Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2010
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
BACKGROUND: Serial casting is often prescribed after botulinum toxin injections to improve joint ranges of motion and to potentiate the decrease in hypertonia. The aim of this study was to compare delayed versus immediate serial casting as an adjunct to botulinum toxin therapy for partially reducible spastic equinus. METHODS: Twelve children who presented spastic equinus associated with mild gastrosoleus contracture took part. Five of them had a diagnosis of spastic diplegia, whereas 7 had a diagnosis of congenital hemiplegia. Children were randomized to immediate serial casting (same day) or delayed serial casting (4 weeks later) after botulinum toxin injection to their gastrosolei. Casts were replaced weekly for 3 weeks. RESULTS: Three children complained of pain that required recasting in the immediate casting group versus none in the delayed casting group (P = 0.08). At 3 months, there was a 27-degree improvement in the fast dorsiflexion angle (Tardieu R1) in the delayed casting group versus 17 degrees in the immediate casting group (P = 0.029). At 6 months, a 19-degree improvement persisted in the delayed group compared with 11 degrees in the immediate group (P = 0.010). CONCLUSIONS: There is a clear benefit in delaying serial casting after the injection of botulinum toxin in the recurrence of spasticity at the gastrosoleus that may also offer an advantage regarding the incidence of painful episodes associated with casting. Most importantly, reducing the recurrence of spasticity by delayed serial casting may offer the possibility of decreasing the frequency of botulinum toxin reinjections.
Resumo:
In this paper, aggregate migration patterns during fluid concrete castings are studied through experiments, dimensionless approach and numerical modeling. The experimental results obtained on two beams show that gravity induced migration is primarily affecting the coarsest aggregates resulting in a decrease of coarse aggregates volume fraction with the horizontal distance from the pouring point and in a puzzling vertical multi-layer structure. The origin of this multi layer structure is discussed and analyzed with the help of numerical simulations of free surface flow. Our results suggest that it finds its origin in the non Newtonian nature of fresh concrete and that increasing casting rate shall decrease the magnitude of gravity induced particle migration. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
O objetivo deste trabalho foi avaliar processos de espalhamento e secagem de filme de amido-glicerol-fibras de celulose, preparado por "tape-casting". O espalhamento da suspensão foi avaliado a 50, 150 e 250 cm min-1, seguido de secagem em estufa com circulação forçada de ar, a 40 ou 70ºC; avaliou-se também o espalhamento da suspensão a 150 cm min-1, seguido da secagem do filme sobre suporte de "tape-casting" a 22ºC e 60% de umidade relativa, com velocidades do ar de 4, 6 e 8 m s-1 no túnel de secagem. Ensaios reológicos mostraram que o espalhamento das suspensões a temperaturas inferiores a 50ºC apresentou módulo de elasticidade superior ao módulo viscoso, em todo o espectro de frequências de oscilação. As microscopias mostraram filmes secos a 40 e 70ºC sem defeitos de formação, e cujas propriedades mecânicas não diferiam. A velocidade de espalhamento e a do ar não modificam o tempo de secagem nem as propriedades dos filmes. O tempo de secagem pode ser reduzido para aproximadamente duas horas, o que é importante para a produção dos filmes em larga escala.
Resumo:
Purpose: The aim of this study was to compare the accuracy of fit of three types of implant-supported frameworks cast in Ni-Cr alloy: specifically, a framework cast as one piece compared to frameworks cast separately in sections to the transverse or the diagonal axis, and later laser welded. Materials and Methods: Three sets of similar implant-supported frameworks were constructed. The first group of six 3-unit implant-supported frameworks were cast as one piece, the second group of six were sectioned in the transverse axis of the pontic region prior to casting, and the last group of six were sectioned in the diagonal axis of the pontic region prior to casting. The sectioned frameworks were positioned in the matrix (10 N(.)cm torque) and laser welded. To evaluate passive fit, readings were made with an optical microscope with both screws tightened and with only one-screw tightened. Data were submitted to ANOVA and Tukey-Kramer`s test (p < 0.05). Results: When both screws were tightened, no differences were found between the three groups (p > 0.05). In the single-screw-tightened test, with readings made opposite to the tightened side, the group cast as one piece (57.02 +/- 33.48 mu m) was significantly different (p < 0.05) from the group sectioned diagonally (18.92 +/- 4.75 mu m) but no different (p > 0.05) from the group transversally sectioned (31.42 +/- 20.68 mu m). On the tightened side, no significant differences were found between the groups (p > 0.05). Conclusions: Results of this study showed that casting diagonally sectioned frameworks lowers misfit levels of prosthetic implant-supported frameworks and also improves the levels of passivity to the same frameworks when compared to structures cast as one piece.
Resumo:
Background: This study aimed to compare the cytotoxicity of base-metal dental alloys and to evaluate if the casting method could influence their cytotoxicity. Methods: Disks of base-metal dental alloys were cast by two methods: plasma, under argon atmosphere, injected by vacuum-pressure; and oxygen-gas flame, injected by centrifugation, except Ti-6Al-4V and commercially pure titanium (cpTi), cast only by plasma. SCC9 cells were cultured in culture media D-MEM/Ham`s F12 supplemented, at 37 degrees C in a humidified atmosphere of 5% carbon dioxide and 95% air, on the previously prepared disks. At subconfluence in wells without disks (control), cell number and viability were evaluated. Results: In plasma method, cpTi and Ti-6Al-4V were similar to control and presented higher number of cells than all other alloys, followed by Ni-Cr. In oxygen-gas name method, all alloys presented fewer cells than control. Ni-Cr presented more cells than any other alloy, followed by Co-Cr-Mo-W which presented more cells than Ni-Cr-Ti, Co-Cr-Mo, and Ni-Cr-Be. There were no significant differences between casting methods related to cell number. Cell viability was not affected by either chemical composition or casting methods. Conclusion: cpTi and Ti-6Al-4V were not cytotoxic while Ni-Cr-Be was the most cytotoxic among tested alloys. The casting method did not affect cytotoxicity of the alloys. (c) 2007 Wiley Periodicals, Inc.
Resumo:
This study compared the vertical misfit of 3-unit implant-supported nickel-chromium (Ni-Cr) and cobalt-chromium (Co-Cr) alloy and commercially pure titanium (cpTi) frameworks after casting as 1 piece, after sectioning and laser welding, and after simulated porcelain firings. The results on the tightened side showed no statistically significant differences. On the opposite side, statistically significant differences were found for Co-Cr alloy (118.64 mu m [SD: 91.48] to 39.90 mu m [SD: 27.13]) and cpTi (118.56 mu m [51.35] to 27.87 mu m [12.71]) when comparing 1-piece to laser-welded frameworks. With both sides tightened, only Co-Cr alloy showed statistically significant differences after laser welding. Ni-Cr alloy showed the lowest misfit values, though the differences were not statistically significantly different. Simulated porcelain firings revealed no significant differences.
Resumo:
Técnicas de visualização volumétrica direta propiciam a geração de imagens de alta qualidade já que se baseiam na amostragem do volume de dados original. Tal característica é particularmente importante na área da Medicina, onde imagens digitais de dados volumétricos devem ganhar maior importância como meio de apoio à tomada de decisão por parte dos médicos. No entanto, a geração de imagens com melhor qualidade possível acarreta um alto custo computacional, principalmente em relação ao algoritmo de ray casting, onde a qualidade de imagens depende de um maior número de amostras ao longo do raio fato este refletido no tempo de geração. Assim, a utilização de tais imagens em ambientes interativos é muitas vezes inviabilizada e, para a redução do custo computacional, é necessário abdicar parcialmente da qualidade da imagem. O conceito de qualidade é altamente subjetivo, e sua quantificação está fortemente relacionada à tarefa para qual a imagem está destinada. Na área da Medicina, imagem de boa qualidade é aquela que possibilita ao médico a análise dos dados através da sua representação visual, conduzindo-o a um diagnóstico ou prognóstico corretos. Nota-se que é necessário, então, avaliar a qualidade da imagem em relação a uma determinada tarefa a partir de critérios e métricas subjetivas ou objetivas. A maior parte das métricas objetivas existentes medem a qualidade de imagens com base no cálculo da diferença de intensidade dos pixels, fator que pode não ser suficiente para avaliar a qualidade de imagens do ponto de vista de observadores humanos. Métricas subjetivas fornecem informação mais qualificada a respeito da qualidade de imagens, porém são bastante custosas de serem obtidas. De modo a considerar tais aspectos, o presente trabalho propõe uma métrica objetiva que procura aproximar a percepção humana ao avaliar imagens digitais quanto à qualidade apresentada. Para tanto, emprega o operador gradiente de Sobel (enfatização de artefatos) e o reconhecimento de padrões para determinar perda de qualidade das imagens tal como apontado por observadores humanos. Os resultados obtidos, a partir da nova métrica, são comparados e discutidos em relação aos resultados providos por métricas objetivas existentes. De um modo geral, a métrica apresentada neste estudo procura fornecer uma informação mais qualificada do que métricas existentes para a medida de qualidade de imagens, em especial no contexto de visualização volumétrica direta. Este estudo deve ser considerado um passo inicial para a investigação de uma métrica objetiva mais robusta, modelada a partir de estudos subjetivos.