886 resultados para 030106 Quality Assurance Chemometrics Traceability and Metrological Chemistry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report provides an overview of the development and field testing of the S�_olta Quality Assurance Programme (QAP). It outlines the timeline, key roles and activities and draws upon evaluation data gathered at various stages of the action research and development process. It briefly describes the processes, tools, materials and the professional roles that have been developed to support implementation of the S�_olta QAP. It concludes with consideration of the context within which the S�_olta QAP will operate into the future and makes a set of recommendations to connect this research and development phase for S�_olta and the S�_olta QAP with national and international policy developments related to the improvement of the quality of early childhood care and education (ecce) in Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Longitudinal joint quality control/assurance is essential to the successful performance of asphalt pavements and it has received considerable amount of attention in recent years. The purpose of the study is to evaluate the level of compaction at the longitudinal joint and determine the effect of segregation on the longitudinal joint performance. Five paving projects with the use of traditional butt joint, infrared joint heater, edge restraint by milling and modified butt joint with the hot pinch longitudinal joint construction techniques were selected in this study. For each project, field density and permeability tests were made and cores from the pavement were obtained for in-lab permeability, air void and indirect tensile strength. Asphalt content and gradations were also obtained to determine the joint segregation. In general, this study finds that the minimum required joint density should be around 90.0% of the theoretical maximum density based on the AASHTO T166 method. The restrained-edge by milling and butt joint with the infrared heat treatment construction methods both create the joint density higher than this 90.0% limit. Traditional butt joint exhibits lower density and higher permeability than the criterion. In addition, all of the projects appear to have segregation at the longitudinal joint except for the edge-restraint by milling method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to explore software development methods and quality assurance practices used by South Korean software industry. Empirical data was collected by conducting a survey that focused on three main parts: software life cycle models and methods, software quality assurance including quality standards, the strengths and weaknesses of South Korean software industry. The results of the completed survey showed that the use of agile methods is slightly surpassing the use of traditional software development methods. The survey also revealed an interesting result that almost half of the South Korean companies do not use any software quality assurance plan in their projects. For the state of South Korean software industry large number of the respondents thought that despite of the weakness, the status of software development in South Korea will improve in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many international, political, and economic influences led to increased demands for development of new quality assurance systems for universities. Like many policies and processes that aim to assure quality, Ontario’s Quality Assurance Framework (QAF) did not define quality. This study sought to explore conceptions of quality and approaches to quality assurance used within Ontario’s universities. A document analysis of the QAF’s rationale and structure suggested that quality was conceived primarily as fitness for purpose, while suggested indicators represented an exceptional conception of quality. Ontario universities perpetuated such confusion by adopting the framework without customizing it to their institutional conceptions of quality. Drawing upon phenomenographic traditions, a qualitative investigation was conducted to better understand various conceptions of quality held by university administrators and to appreciate ways in which they implemented the QAF. Three main approaches to quality assurance were identified: (a) Defending Quality, characterized by conceptions of quality as exceptional, which focuses on administrative accountability and uses a hands-off strategy to defend traditional notions of quality inputs and resources; (b) Demonstrating Quality, characterized by conceptions of quality as fitness for purpose and value for money, which focuses on accountability to students and uses centralized engaged strategies to demonstrate how programs meet current priorities and intended outcomes; and (c) Enhancing Quality, characterized by conceptions of quality as transformation, which focuses on reflection and learning experience and uses engaged strategies to find new ways of improving learning and teaching. The development of a campus culture that values the institution’s function in student learning and quality teaching would benefit from Enhancing Quality approaches to quality assurance. This would require holistic consideration of the beliefs held by members of the institution, a clear articulation of the institution’s conceptions of quality, and a critical analysis of how these conceptions align with institutional practices and policies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In its recent report on the Graduate Teacher Programme (GTP), an employment-based route to Qualified Teacher Status (QTS) in England, the Government's Office for Standards in Education found that, although almost all trainees meet the standards required to qualify, too often they do so at an adequate level, rather than achieving the high levels of which they should be capable. The underlying reason for this is the quality of mentoring provided in the schools. The inspectors concluded that schoolbased trainers are often not adequately prepared for their role in implementing wide-ranging training programmes for trainee teachers. Despite this generally bleak picture, Ofsted concluded that 'the minority of cases of good practice in the training programmes and of high quality teaching by trainees indicate that the GTP can be an effective alternative route for training teachers'™. This article considers the strengths and weaknesses of the Graduate Teacher Programme, introduced in January 1998, and also reports on a small-scale project, funded by the Teacher Training Agency (TTA), the key objective of which was to strengthen the existing partnerships by improving the quality of school-based tutor training and continuous professional development of staff.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human movement analysis (HMA) aims to measure the abilities of a subject to stand or to walk. In the field of HMA, tests are daily performed in research laboratories, hospitals and clinics, aiming to diagnose a disease, distinguish between disease entities, monitor the progress of a treatment and predict the outcome of an intervention [Brand and Crowninshield, 1981; Brand, 1987; Baker, 2006]. To achieve these purposes, clinicians and researchers use measurement devices, like force platforms, stereophotogrammetric systems, accelerometers, baropodometric insoles, etc. This thesis focus on the force platform (FP) and in particular on the quality assessment of the FP data. The principal objective of our work was the design and the experimental validation of a portable system for the in situ calibration of FPs. The thesis is structured as follows: Chapter 1. Description of the physical principles used for the functioning of a FP: how these principles are used to create force transducers, such as strain gauges and piezoelectrics transducers. Then, description of the two category of FPs, three- and six-component, the signals acquisition (hardware structure), and the signals calibration. Finally, a brief description of the use of FPs in HMA, for balance or gait analysis. Chapter 2. Description of the inverse dynamics, the most common method used in the field of HMA. This method uses the signals measured by a FP to estimate kinetic quantities, such as joint forces and moments. The measures of these variables can not be taken directly, unless very invasive techniques; consequently these variables can only be estimated using indirect techniques, as the inverse dynamics. Finally, a brief description of the sources of error, present in the gait analysis. Chapter 3. State of the art in the FP calibration. The selected literature is divided in sections, each section describes: systems for the periodic control of the FP accuracy; systems for the error reduction in the FP signals; systems and procedures for the construction of a FP. In particular is detailed described a calibration system designed by our group, based on the theoretical method proposed by ?. This system was the “starting point” for the new system presented in this thesis. Chapter 4. Description of the new system, divided in its parts: 1) the algorithm; 2) the device; and 3) the calibration procedure, for the correct performing of the calibration process. The algorithm characteristics were optimized by a simulation approach, the results are here presented. In addiction, the different versions of the device are described. Chapter 5. Experimental validation of the new system, achieved by testing it on 4 commercial FPs. The effectiveness of the calibration was verified by measuring, before and after calibration, the accuracy of the FPs in measuring the center of pressure of an applied force. The new system can estimate local and global calibration matrices; by local and global calibration matrices, the non–linearity of the FPs was quantified and locally compensated. Further, a non–linear calibration is proposed. This calibration compensates the non– linear effect in the FP functioning, due to the bending of its upper plate. The experimental results are presented. Chapter 6. Influence of the FP calibration on the estimation of kinetic quantities, with the inverse dynamics approach. Chapter 7. The conclusions of this thesis are presented: need of a calibration of FPs and consequential enhancement in the kinetic data quality. Appendix: Calibration of the LC used in the presented system. Different calibration set–up of a 3D force transducer are presented, and is proposed the optimal set–up, with particular attention to the compensation of non–linearities. The optimal set–up is verified by experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enterprise Applications are complex software systems that manipulate much persistent data and interact with the user through a vast and complex user interface. In particular applications written for the Java 2 Platform, Enterprise Edition (J2EE) are composed using various technologies such as Enterprise Java Beans (EJB) or Java Server Pages (JSP) that in turn rely on languages other than Java, such as XML or SQL. In this heterogeneous context applying existing reverse engineering and quality assurance techniques developed for object-oriented systems is not enough. Because those techniques have been created to measure quality or provide information about one aspect of J2EE applications, they cannot properly measure the quality of the entire system. We intend to devise techniques and metrics to measure quality in J2EE applications considering all their aspects and to aid their evolution. Using software visualization we also intend to inspect to structure of J2EE applications and all other aspects that can be investigate through this technique. In order to do that we also need to create a unified meta-model including all elements composing a J2EE application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation delivered to patients who enrolled in past clinical trials. Methods A multi-source model representing output for Varian 6 MV and 10 MV photon beams was developed and evaluated. The Monte Carlo algorithm, know as the Dose Planning Method (DPM), was used to perform the dose calculations. The dose calculations were compared to measurements made in a water phantom and in anthropomorphic phantoms. Intensity modulated radiation therapy and stereotactic body radiation therapy techniques were used with the anthropomorphic phantoms. Finally, past patient treatment plans were selected and recalculated using DPM and contrasted against a commercial dose calculation algorithm. Results The multi-source model was validated for the Varian 6 MV and 10 MV photon beams. The benchmark evaluations demonstrated the ability of the model to accurately calculate dose for the Varian 6 MV and the Varian 10 MV source models. The patient calculations proved that the model was reproducible in determining dose under similar conditions described by the benchmark tests. Conclusions The dose calculation tool that relied on a multi-source model approach and used the DPM code to calculate dose was developed, validated, and benchmarked for the Varian 6 MV and 10 MV photon beams. Several patient dose distributions were contrasted against a commercial algorithm to provide a proof of principal to use as an application in monitoring clinical trial activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Two patient-focused long-term research projects performed in the German outpatient psychotherapy system are focused on in this article. The TK (Techniker Krankenkasse) project is the first study to evaluate a quality assurance and feedback system with regard to its practical feasibility in German routine care. The other study (“Quality Assurance in Outpatient Psychotherapy in Bavaria”; QS-PSY-BAY) was designed to test a new approach for quality assurance in outpatient psychotherapy using electronic documentation of patient characteristics and outcome parameters. In addition this project provides the opportunity to analyze data on health-related costs for the patients undergoing outpatient psychotherapy. Method: Both projects and their results indicating high effect sizes are briefly described. Results: From the perspectives of the research teams, advisory boards and other stakeholders, the experiences with these projects are discussed focusing on obstacles, challenges, difficulties, and benefits in developing and implementing the studies. The triangle collaboration of therapists, researchers, and health insurance companies/health service institutions turned out to be fruitful in both studies. Conclusions: Despite some controversies between the partners the experiences indicate the importance of practiced-research collaborations to provide relevant information about the delivery of outpatient psychotherapy in the health system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.