Determination of carbohydrate-deficient transferrin in human serum by capillary zone electrophoresis: evaluation of assay performance and quality assurance over a 10-year period in the routine arena.
Data(s) |
01/06/2013
|
---|---|
Resumo |
The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/53976/1/wt228-CDT%20quality%20control.pdf Joneli, Jeannine; Wanzenried, Ursula; Schiess, Jeannette; Lanz, Christian; Caslavsky, Jitka; Thormann, Wolfgang (2013). Determination of carbohydrate-deficient transferrin in human serum by capillary zone electrophoresis: evaluation of assay performance and quality assurance over a 10-year period in the routine arena. Electrophoresis, 34(11), pp. 1563-1571. Wiley-VCH 10.1002/elps.201200653 <http://dx.doi.org/10.1002/elps.201200653> doi:10.7892/boris.53976 info:doi:10.1002/elps.201200653 info:pmid:23512316 urn:issn:0173-0835 |
Idioma(s) |
eng |
Publicador |
Wiley-VCH |
Relação |
http://boris.unibe.ch/53976/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Joneli, Jeannine; Wanzenried, Ursula; Schiess, Jeannette; Lanz, Christian; Caslavsky, Jitka; Thormann, Wolfgang (2013). Determination of carbohydrate-deficient transferrin in human serum by capillary zone electrophoresis: evaluation of assay performance and quality assurance over a 10-year period in the routine arena. Electrophoresis, 34(11), pp. 1563-1571. Wiley-VCH 10.1002/elps.201200653 <http://dx.doi.org/10.1002/elps.201200653> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |