964 resultados para spore dosimetry
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Radiofarmácia
Resumo:
Mestrado em Radioterapia
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde- Ramo de especialização: Terapia com Radiações
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.
Resumo:
Purpose: To compare image quality and effective dose when the 10 kVp rule is applied with manual and AEC mode in PA chest X-ray. Methods and Materials: A total of 68 images (with and without lesions) were acquired of an anthropomorphic chest phantom in a Wolverson Arcoma X-ray unit. The images were evaluated against a reference image using image quality criteria and the 2 alternative forced choice (2 AFC) method by five radiographers. The effective dose was calculated using PCXMC software using the exposure parameters and DAP. The exposure index (lgM) was recorded. Results: Exposure time decreases considerably when applying the 10 kVp rule in manual mode (50%-28%) compared to AEC mode (36%-23%). Statistical differences for effective dose between several AEC modes were found (p=0.002). The effective dose is lower when using only the right AEC ionization chamber. Considering image quality, there are no statistical differences (p=0.348) between the different AEC modes for images with no lesions. Using a higher kVp value the lgM values will also increase. The lgM values showed significant statistical differences (p=0.000). The image quality scores did not present statistically significant differences (p=0.043) for the images with lesions when comparing manual with AEC modes. Conclusion: In general, the dose is lower in the manual mode. By using the right AEC ionising chamber the effective dose will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the detectability of the lesions.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Biologia (especialidade Microbiologia), pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.
Resumo:
A TC é um valioso método diagnóstico radiológico. O exame TC pode expor o paciente a uma dose elevada de exposição à radiação, causando risco acrescido. Uma das possíveis soluções para a redução da dose é o uso de técnicas de reconstrução iterativa (IR) em vez das reconstruções tradicionais (FBP). Com base nas suas capacidades de redução de ruído na imagem, a IR pode ter o potencial de reduzir significativamente a dose em pacientes submetidos a TC sem prejudicar a qualidade de imagem. Manter a qualidade de imagem clínica com um nível de qualidade aceitável e expondo o paciente à menor dose possível.
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
Aims: The main aims of this work were the study of cork slabs moulds colonization and the evaluation of the moulds diversity during cork processing steps, in different cork stoppers factories. Simultaneously, it was envisaged to perform an evaluation of the air quality. Methods and Results: Moulds were isolated and identified from cork slabs and cork samples in four cork stoppers factories. The identification was based on morphological characters and microscopic observation of the reproductive structures. Airborne spore dispersion was assessed using a two stage Andersen sampler. It was observed that Chrysonilia sitophila was always present on cork slabs during the maturing period, but mould diversity appeared to be associated to the different factory configurations and processing steps. Conclusions: Spatial separation of the different steps of the process, including physical separation of the maturation step, is essential to guarantee high air quality and appropriate cork slabs colonization, i.e. C. sitophila dominance. The sorting and cutting of the edges of cork slabs after boiling and before the maturing step is also recommended. Significance and Impact of the Study: This study is very important for the cork stopper industry as it gives clear indications on how to keep high quality manufacturing standards and how to avoid occupational health problems.
Resumo:
Resumo - O avanço tecnológico e científico no campo da Medicina tem favorecido a aplicação das radiações ionizantes nas áreas da Medicina Nuclear, Radiologia, Radioterapia e noutras especialidades relacionadas com a medicina de intervenção, como a Cardiologia. As Organizações de Saúde, com profissionais com risco de exposição a radiações ionizantes, são responsáveis, legislativamente, por assegurar a sua vigilância. Certificando a observação controlada das doses de exposição, os profissionais são monitorizados com dosímetros individuais e submetidos a vigilância médica. As leituras de dosímetria individual destes profissionais, originam por vezes, nos próprios, desconfianças e incertezas quanto aos valores medidos. Objectivo: avaliar o grau de confiança dos profissionais de saúde, expostos a radiações ionizantes, no sistema de monitorização individual. Metodologia: estudo observacional do tipo analítico- transversal, por questionário. Amostra de 190 Técnicos de Diagnóstico e Terapêutica de Cardiopneumologia, Medicina Nuclear, Radiologia, Radioterapia, expostos a radiações ionizantes, que exercem a sua actividade profissional em hospitais do concelho de Lisboa. Resultados: 51,1% dos Técnicos de Diagnóstico e Terapêutica não confiam nas leituras dos dosímetros, não se determinou uma relação estatisticamente significativa entre essa confiança, o tipo de dosímetro e a empresa que realiza as leituras. A confiança é maior nos que exercem em Organizações de Saúde públicas. 40,2% das Organizações de Saúde apresentam plano de vigilância médica, constatando-se uma falta de conformidade entre os Técnicos de Diagnóstico e Terapêutica, nalguns hospitais, relativamente à existência desse plano no respectivo hospital. A margem de erro associado ao estudo é de 5,09%, com um nível de confiança de 95%. -----------Abstract - The technological and scientific advances in the field of medicine has encouraged the application of ionizing radiation with a considerable positive contribution in the areas of Nuclear Medicine, Radiology, Radiotherapy and other specialties related to medical intervention like Cardiology. The Health Organizations that arise the risk of occupational exposure to ionizing radiation and is their responsibility to ensure monitoring, according the law. To ensure the monitoring of controlled doses of exposure, the exposed works use an individual dosimeter and undergo medical supervision. The individual dosimetry readings of health-care professionals, is sometimes questionable for themselves, arising distrust and uncertainty about the values measured. Objective: evaluate the degree of confidence of health professionals, exposed to radiation, on the system of individual monitoring. Methods: Observational study of cross-type analysis by questionnaire. Sample of 190 of technologists of Cardiopneumology, Nuclear Medicine, Radiology, Radiotherapy, exposed to ionizing radiation, which work in hospitals on the region of Lisbon. Results: 51.1% of technologists does not rely on the readings of their dosimeters, and wasn’t determined a statistically significant relationship between this trust, the type of dosimeter and the company that makes the readings(s) of their(s) dosimeter(s). The confidence in the readings is higher in public Health Organizations. 40.2% of the Health Organizations have medical monitoring plan and there is a disagreement between technologists, in some hospitals, relatively to the existence of this plan in their hospital. It was estimated that the u
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica
Resumo:
RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.
Resumo:
RESUMO: A esporulação em Bacillus subtilis é controlada por uma cascata de factores sigma da polimerase do RNA. F e E controlam os estágios precoces do desenvolvimento no pré-esporo e na célula mãe, respectivamente. Numa fase intermédia da diferenciação, quando a célula mãe acaba por envolver o pré-esporo, F é substituído por G e E é substituído por K. Vários mecanismos asseguram que a actividade dos diferentes factores sigma seja confinada a uma janela temporal precisa na célula adequada. Neste estudo, investigámos a função de um factor anti-G, designado por CsfB. Mostramos que para além da sua função de inibição da actividade do factor G em células pré-divisionais, CsfB é também necessário na célula mãe num estágio tardio do desenvolvimento. Mostramos que a expressão de csfB é activada na célula mãe a partir de um promotor dependente de K. Contudo, demonstramos que CsfB interage directamente com E e não com K, e que CsfB é suficiente para inibir a actividade transcricional dependente de E em células vegetativas de B. subtilis. Propomos que CsfB contribui para reduzir o período dependente de E, na linha de expressão genética da célula mãe, desse modo reduzindo a sobreposição entre os regulões E e K e aumentado a fidelidade do processo de desenvolvimento. Uma segunda proteína, YabK, partilha semelhança estrutural com CsfB. YabK é produzida no pré-esporo sob o comando de F, e é necessária para a esporulação. YabK contribui para a transição F/G no programa genético do pré-esporo, porque uma mutação que torna F sensível a CsfB ultrapassa parcialmente a função de YabK na esporulação. No entanto, YabK e CsfB funcionam por mecanismos diferentes, uma vez que YabK não liga directamente a F.---------ABSTRACT: Gene expression during spore development in Bacillus subtilis is governed by a cascade of RNA polymerase sigma factors. F and E control the early stages of development in the forespore and in the mother cell, respectively. At an intermediate stage in the differentiation process, when the larger mother cell finishes engulfment of the smaller forespore, F is replaced by G and E is replaced by K. Several mechanisms ensure the proper timing of activation of the cell type-specific sigma factors. Here, we have investigated the funtion of an anti-sigma G factor, called CsfB. We show here that in addition to its role in inhibiting G in pre-divisional cells, CsfB is also required in the mother cell at a late stage in development. We show that the expression of csfB is activated in the mother cell from a K-specific promoter. However, we demonstrate that CsfB binds directly to E but not to K in a yeast two-hybrid assay, and that CsfB is sufficient to inhibit E-dependent transcriptional activity in vegetative cells of B. subtilis. We posit that CsfB contributes to shutting off the early, E-controlled period in the mother cell line of gene expression, thus reducing the overlap between deployment of the E and K regulons and increasing the fidelity of the developmental process. A second protein, YabK, shares structural similarity with CsfB. YabK is produced in the forespore under F control, and is required for efficient sporulation. YabK contributes to the transition from the F- to the G-dependent period of gene expression, because a mutation that renders F sensitive to CsfB partially bypasses the need for YabK. Yet, YabK and CsfB must function in the control of sigma factor activity by different mechanisms because YabK does not bind directly to F.