862 resultados para electronic ink


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presentation at Open Repositories 2014, Helsinki, Finland, June 9-13, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paper-based analytical technologies enable quantitative and rapid analysis of analytes from various application areas including healthcare, environmental monitoring and food safety. Because paper is a planar, flexible and light weight substrate, the devices can be transported and disposed easily. Diagnostic devices are especially valuable in resourcelimited environments where diagnosis as well as monitoring of therapy can be made even without electricity by using e.g. colorimetric assays. On the other hand, platforms including printed electrodes can be coupled with hand-held readers. They enable electrochemical detection with improved reliability, sensitivity and selectivity compared with colorimetric assays. In this thesis, different roll-to-roll compatible printing technologies were utilized for the fabrication of low-cost paper-based sensor platforms. The platforms intended for colorimetric assays and microfluidics were fabricated by patterning the paper substrates with hydrophobic vinyl substituted polydimethylsiloxane (PDMS) -based ink. Depending on the barrier properties of the substrate, the ink either penetrates into the paper structure creating e.g. microfluidic channel structures or remains on the surface creating a 2D analog of a microplate. The printed PDMS can be cured by a roll-ro-roll compatible infrared (IR) sintering method. The performance of these platforms was studied by printing glucose oxidase-based ink on the PDMS-free reaction areas. The subsequent application of the glucose analyte changed the colour of the white reaction area to purple with the colour density and intensity depending on the concentration of the glucose solution. Printed electrochemical cell platforms were fabricated on paper substrates with appropriate barrier properties by inkjet-printing metal nanoparticle based inks and by IR sintering them into conducting electrodes. Printed PDMS arrays were used for directing the liquid analyte onto the predetermined spots on the electrodes. Various electrochemical measurements were carried out both with the bare electrodes and electrodes functionalized with e.g. self assembled monolayers. Electrochemical glucose sensor was selected as a proof-of-concept device to demonstrate the potential of the printed electronic platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkielman nimi käännettynä suomeksi on Lentokoneiden omasuojajärjestelmien kyllästäminen – mahdollisuuksia kätkeytymiseen. Siinä keskitytään etsimään aktiivisia, ilmauhkaa kohti säteileviä keinoja ilmahyökkääjän, lentokoneen tai helikopterin, omasuojajärjestelmän harhauttamiseksi. Järjestelmät pyrkivät varoittamaan lentäjää laser- ja tutkasäteilyhavainnoista sekä ohjuksen laukaisusta ja lähestymisestä. Omasuojajärjestelmiin kuuluviin vastakeinoihin tutkimus ei keskity. Tavoitteena harhauttamisella on ilmapuolustuksen todellisen määrän ja sijainnin suojaaminen. Epätietoisuus voi saada lentäjän tekemään vääriä johtopäätöksiä. Työ ei fokusoi harhauttamisen taktiseen kehykseen työn kannalta tarpeellista määrää enempää. Tietosuojasyistä tutkimus ei käsittele käytössä olevien omasuojajärjestelmien operatiivisia ominaisuuksia vaan käsittelee teoriaa niiden taustalla. Tutkimus tehtiin käyttäen taustatutkimukselle enemmän tyypillistä kirjallisuustutkimusta. Jo tutki-muksen alkuvaiheessa oli oletettavaa, että elektronisiin sensoreihin perustuvaa omasuojajärjestelmää pystytään harhauttamaan. Systeemianalysoinnilla pyrittiin löytämään vastauksia tähän olettamukseen. Omasuojajärjestelmästä muodostettiin jo tutkimuksen varhaisessa vaiheessa malli. Tieteellistä kirjallisuutta omasuojajärjestelmistä on olemassa jonkin verran, ja niistä löydettyä tietoa omasuojajärjestelmien ominaisuuksista ja sensoreista yhdistettiin malliin niin, että siitä saatiin mahdollisimman tarkka systeemin kuvaus todellisesta omasuojajärjestelmästä. Analyysin tavoitteena oli löytää niitä kriteereitä, joilla omasuojajärjestelmä saataisiin kohtuullisen tehokkaasti uskomaan harhautusta oikeaksi hälytykseksi. Ohjuksen laukaisusta varoittava sensori perustuu ohjuksen moottorin muodostaman pilven lämpö-säteilyyn. Säteily kuitenkin muuttuu lennon eri vaiheissa, mikä tuottaa haasteita järjestelmälle. Millimetrialueen tutkan käyttö varoittimen sensorina on myös yksi vaihtoehto. Laser-varoittimet toimivat koko sillä taajuusalueella, mitä sotilaskäytössä tulenjohtamiseen ja ohjusten ohjaamiseen käytetään. Tutkavaroittimen tutkimus on vielä kesken. Löydettyjä tuloksia analysoimalla tulen tässä vaiheessa hieman ristiriitaisiin tuloksiin. Lämpösäteilyn käytön suurin haaste on sen eteneminen ilmakehässä. Varoittimen tavoitekaan ei ole toimia kymmentä kilometriä pidemmälle. Yksi mahdollinen ratkaisu on suunnitella ja toteuttaa raketti, jonka tuottaa lämpösäteilyä kuten tietty puolustavan joukon käytössä oleva ohjus. Jos koneessa on kuitenkin myös millimetrialueen tutka tukemassa varoitusjärjestelmää, hankaloituu rakettiharhautus merkittävästi, koska sen pitäisi oletettavasti olla lentokoneen kanssa melko tarkasti kohtaavalla reitillä. Laser-varoitin on ilmeisesti herkin järjestelmistä, koska se voi tietyissä olosuhteissa ja varsinkin matalalla lentokorkeudella aiheuttaa paljon vääriä hälytyksiä ilman tarkoituksellista harhauttamista. Laserin käyttö yhdistettynä raketin laukaisuun saattaisi tuottaa halutun tuloksen. Tutkavaroittimen harhautus onnistuu, jos valelaitteen signaali on uskottavan tarkka.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception) induced by small doses of carrageenin (30 µg). The electronic pressure-meter detected the antinociceptive effect of non-steroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg) or intraplantarly (30-300 µg/paw) prevented the hypersensitive effect of carrageenin (100 µg/paw). The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E2 (PGE2; 10-100 ng) in a dose-dependent manner. The hypernociceptive effect of PGE2 (100 ng) was blocked by dipyrone (160 and 320 µg/paw) but not by intraplantar administration of indomethacin (300 µg/paw). The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin) or directly block the ongoing hypernociception (dipyrone).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this thesis was to study value creation through sponsor-ship in a new emerging electronic sports environment. Sub-questions were formulated which helped in finding answers to the main research question. Theory of traditional sports and practice of electronic sports were compared with each other in order to find out how theories of tradi-tional sports fare in the new environment. B2B-relationship model of Actors, resources and activities is used in this thesis to help in clarifying the different variables used in electronic sports sponsorship environment. The empirical research was conducted via interviews with the managers working in electronic sports environment. One of the main conclusions is that relationship management is really important.. Actors in electronic sports need to find and create win-win-win situations. This means that they need to benefit the actors in sponsoring relationship and also the community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin-film photovoltaic solar cells based on the Cu(In1−xGax)Se2 (CIGS) alloys have attracted more and more attention due to their large optical absorption coefficient, long term stability, low cost, and high efficiency. Modern theoretical studies of this material with first-principles calculations can provide accurate description of the electronic structure and yield results in close agreement with experimental values, but takes a large amount of calculation time. In this work, we use first-principles calculations based on the computationally affordable meta- generalized gradient approximation of the density-functional theory to investigate electronic and structural properties of the CIGS alloys. We report on the simulation of the lattice parameters and band gaps, as a function of chemical composition. The obtained results were found to be in a good agreement with the available experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The focus of the work reported in this thesis was to study and to clarify the effect of polyelectrolyte multilayer surface treatment on inkjet ink spreading, absorption and print quality. Surface sizing with a size press, film press with a pilot scale coater, and spray coating, have been used to surface treat uncoated wood-free, experimental wood-free and pigmentcoated substrates. The role of the deposited cationic (polydiallydimethylammonium chloride, PDADMAC) and anionic (sodium carboxymethyl cellulose, NaCMC) polyelectrolyte layers with and without nanosilica, on liquid absorption and spreading was studied in terms of their interaction with water-based pigmented and dye-based inkjet inks. Contact angle measurements were made in attempt to explain the ink spreading and wetting behavior on the substrate. First, it was noticed that multilayer surface treatment decreased the contact angle of water, giving a hydrophilic character to the surface. The results showed that the number of cationic-anionic polyelectrolyte layers or the order of deposition of the polyelectrolytes had a significant effect on the print quality. This was seen for example as a higher print density on layers with a cationic polyelectrolyte in the outermost layer. The number of layers had an influence on the print quality; the print density increased with increasing number of layers, although the increase was strongly dependent on ink formulation and chemistry. The use of nanosilica clearly affected the rate of absorption of polar liquids, which also was seen as a higher density of the black dye-based print. Slightly unexpected, the use of nanosilica increased the tendency for lateral spreading of both the pigmented and dye-based inks. It was shown that the wetting behavior and wicking of the inks on the polyelectrolyte coatings was strongly affected by the hydrophobicity of the substrate, as well as by the composition or structure of the polyelectrolyte layers. Coating only with a cationic polyelectrolyte was not sufficient to improve dye fixation, but it was demonstrated that a cationic-anionic-complex structure led to good water fastness. A threelayered structure gave the same water fastness values as a five-layered structure. Interestingly, the water fastness values were strongly dependent not only on the formed cation-anion polyelectrolyte complexes but also on the tendency of the coating to dissolve during immersion in water. Results showed that by optimizing the chemistry of the layers, the ink-substrate interaction can be optimized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was a comparative investigation of face-toface (i.e., proximate) and computer-mediated written (i.e., graphic) pre-writing conferences. The participants in this study were advanced English as a second language students. The 2 types of conferences were compared in terms of textual features, participation, and the . degree to which they were on topic. Moreover, drafts written after the 2 types of conferences were compared in terms of textual features, and the degree to which they were related to the conferences. Students produced an equivalent amount of discourse in an equivalent amount of time in the 2 types of conferences. The discourse in graphic conferences displayed greater lexical range, and some evidence suggests that it was less on-topic. Both these results likely occurred because the graphic conferences contained more discourse demonstrating interactive competence. Participation in graphic conferences was found to be as balanced or more balanced among students, and among students and the group leader combined. Overall, the drafts produced after the 2 types of conferences were of equivalent length and topical range, but some evidence suggests that drafts written after proximate conferences were more related to the conferences.