974 resultados para Zn-metastables
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The Inoue procedure is used to study the influence of Cr and Cu elements, jointly or individually, on the matrix decomposition of quenched Al-Zn-Mg alloys. The addition of copper and copper with chromium does not significantly change the limits of the temperatures of formation of Guinier-Preston zone and the range of the matrix decomposition. The control of the vacancy concentration in the alloys by different heat treatments and the addition of certain elements such as copper and chromium seems to play an important role in the nucleation rate and the kinetics of phase transformations.
Resumo:
The following research project deals with the development of new analytical procedures aimed at the identification and quantification of the element zinc in different fractions of vegetable drugs used for weight loss, using the high-resolution continuum source atomic absorption spectrometry in flame. The determination of the levels of zinc was made in an AnalytikJena ContrAA 300 spectrometer in the principal line of Zn at 213.857 nm and wavelength integrated absorbance equal to 3 pixels. Calibration curves were obtained with linear dynamic range from 0.10 to 1.00 mg L-1, correlation coefficient equal to 0.9991 and limit of detection equal to 0.020 mg L-1. The total Zn content in the samples obtained after microwave-assisted acid digestion system were: 28.06 mg kg-1 (Artichoke), 31.49 mg kg-1 (Chamomile), 77.16 mg kg-1 (Gorse), 105.38 mg kg-1 (Horsetail), 32.37 mg kg-1 (Fennel) and 5.00 mg kg-1 (Senna). The extraction in aqueous environment assisted by microwave radiation produced extracts containing: 5.40 mg kg-1 (Artichoke), 10.65 mg kg-1 (Chamomile), 14.83 mg kg-1 (Gorse), 18.90 mg kg-1 (Horsetail), 7.80 mg kg-1 (Fennel), 3.24 mg kg-1 (Senna), corresponding to 19%, 34%, 19%, 18%, 24% and 64% of their total content of Zn, respectively. The amounts of Zn in the extracted samples from some plants indicate that this metal was strongly bounded to the plant's matrix. The sequential extraction using solvents and mixtures with different polarities (n-hexane, ethyl acetate, propanol, methanol, ethanol-water 1:1 (v/v), water) aimed the separation of different Zn containing species and water was considered the most efficient extractor. The Zn contents extracted were: 14.82 mg kg-1 (Artichoke), 16.82 mg kg-1 (Chamomile), 34.09 mg kg-1 (Gorse), 4.75 mg kg-1 (Senna), corresponding to 53% in the first two samples, 44% and 95% for the last two, respectively. It was observed that Zn is found complexed under
Resumo:
Zinc oxide (ZnO) and aluminum-doped zinc oxide (ZnO:Al) thin films were deposited onto glass and silicon substrates by RF magnetron sputtering using a zinc-aluminum target. Both films were deposited at a growth rate of 12.5 nm/min to a thickness of around 750 nm. In the visible region, the films exhibit optical transmittances which are greater than 80%. The optical energy gap of ZnO films increased from 3.28 eV to 3.36 eV upon doping with Al. This increase is related to the increase in carrier density from 5.9 × 1018 cm-3 to 2.6 × 1019 cm-3. The RMS surface roughness of ZnO films grown on glass increased from 14 to 28 nm even with only 0.9% at Al content. XRD analysis revealed that the ZnO films are polycrystalline with preferential growth parallel to the (002) plane, which corresponds to the wurtzite structure of ZnO.
Resumo:
The diffusive gradients in thin films (DGT) technique has shown enormous potential for labile metal monitoring in fresh water due to the preconcentration, time-integrated, matrix interference removal and speciation analytical features. In this work, the coupling of energy dispersive X-ray fluorescence (EDXRF) with paper-based DGT devices was evaluated for the direct determination of Mn, Co. Ni, Cu, Zn and Pb in fresh water. The DGT samplers were assembled with cellulose (Whatman 3 MM chromatography paper) as the diffusion layer and a cellulose phosphate ion exchange membrane (Whatman P 81 paper) as the binding agent. The diffusion coefficients of the analytes on 3 MM chromatography paper were calculated by deploying the DGT samplers in synthetic solutions containing 500 mu g L-1 of Mn. Co, Ni, Cu, Zn and Pb (4 L at pH 5.5 and ionic strength at 0.05 mol L-1). After retrieval, the DGT units were disassembled and the P81 papers were dried and analysed by EDXRF directly. The 3 MM chromatographic paper diffusion coefficients of the analytes ranged from 1.67 to 1.87 x 10(-6) cm(2) s(-1). The metal retention and phosphate group homogeneities on the P81 membrane was studied by a spot analysis with a diameter of 1 mm. The proposed approach (DGT-EDXRF coupling) was applied to determine the analytes at five sampling sites (48 h in situ deployment) on the Piracicaba river basin, and the results (labile fraction) were compared with 0.45 mu m dissolved fractions determined by synchrotron radiation-excited total reflection X-ray fluorescence (SR-TXRF). The limits of detection of DGT-EDXRF coupling for the analytes (from 7.5 to 26 mu g L-1) were similar to those obtained by the sensitive SR-TXRF technique (3.8 to 9.1 mu g L-1). (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The hysteresis loss subdivision method proved to be a strong tool to help in the analysis of different energy dissipation mechanisms along the quasi-static hysteresis loop measured on electrical steels. This paper used the samemethod to discuss the mechanisms involving the energy loss dissipation in Mn-Zn ferrite toroidal cores. The samples, sintered under controlled atmosphere in industrial conditions, were measured under triangular waveform excitation at very low frequency (5 mHz) and peak flux densities varying from 0.05 T to 0.45 T. The results show a different behavior between the low inductions hysteresis loss (WLI) and the high induction hysteresis loss (WHI) which proves the existence of different energy dissipation mechanisms affecting these loss components.
Resumo:
Estuarine systems play an important role in the retention of toxic trace elements owing to the affinity of these elements with particles dissolved in water. This work presents the use of a voltammetric sensor to monitor heavy metal (Zn (II), Cd(II) and Pb (II)) concentrations in the Cananeia-Iguape Estuarine-Lagoon region (Sao Paulo State, Brazil). Lower concentrations were found in the Southern estuarine system (Cananeia City) and increased concentrations observed in the Northern sector (Iguape City) were promoted by anthropogenic activities, with particular influence from the historical introduction of mining wastes and inputs from agricultural, industrial and domestic effluents. The proposed method is reliable, inexpensive and fast, can simultaneously provide information on the concentration of these metallic ions and can be easily used for field measurements aboard oceanographic ships.
Resumo:
Several types of alumina were synthesized from sodium aluminate (NaAlO2) by precipitation with sulfuric acid (H2SO4) and subsequently calcination at 500 degrees C to obtain gamma-Al2O3. The precursor aluminate was derived from aluminum scrap. The various gamma-Al2O3 synthesized were characterized by Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), adsorption-desorption of N-2 (S-BET) and scanning electron microscopy (SEM). XRD revealed that distinct phases of Al2O3 were formed during thermal treatment. Moreover, it was observed that conditions of synthesis (pH, aging time and temperature) strongly affect the physicochemical properties of the alumina. A high-surface-area alumina (371 m(2) g(-1)) was synthesized under mild conditions, from inexpensive raw materials. These aluminas were tested for the adsorption of Cd(II), Zn(II) and Pb(II) from aqueous solution at toxic metal concentrations, and isotherms were determined. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
An octahedral Zn complex with o-phenanthroline (o-phen) and cyanoguanidine (cnge) has been synthesized and characterized. The crystal structural data show the formation of a ZnN5O core where the metal coordinates to two mutually perpendicular o-phenanthrolines as bidentate ligands [Zn-N bond lengths in the 2.124(2)-2.193(2) angstrom range], the cyanide nitrogen of a cnge [d(Zn-N) = 2.092(2) angstrom, angle(Zn-N-C) = 161.1(2)degrees], and a water molecule [d(Zn-Ow) = 2.112(2) angstrom]. Spectral data (FT-IR, Raman, and fluorescence) and speciation studies are in agreement with the structure found in the solid state and the one proposed to exist in the solution. To evaluate the changes in the microbiological activity of Zn, antibacterial studies were carried out by observing the changes in minimum inhibitory concentration of the complex, the ligands, and the metal against five different bacterial strains. The antibacterial activity of Zn improved upon complexation in three of the tested strains.
Resumo:
A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 mu L) were diluted 1:50 in a solution containing 0.01% v/v Triton (R) X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 mu g L-1 for Ca-44, Cu-63, Fe-57, Mg-24, Zn-64, Se-82 and Mn-55, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.
Resumo:
A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 µL) were diluted 1:50 in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 µg L-1 for 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 82Se and 55Mn, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.
Resumo:
Estuarine systems play an important role in the retention of toxic trace elements owing to the affinity of these elements with particles dissolved in water. This work presents the use of a voltammetric sensor to monitor heavy metal (Zn (II), Cd(II) and Pb (II)) concentrations in the Cananéia-Iguape Estuarine-Lagoon region (São Paulo State, Brazil). Lower concentrations were found in the Southern estuarine system (Cananéia City) and increased concentrations observed in the Northern sector (Iguape City) were promoted by anthropogenic activities, with particular influence from the historical introduction of mining wastes and inputs from agricultural, industrial and domestic effluents. The proposed method is reliable, inexpensive and fast, can simultaneously provide information on the concentration of these metallic ions and can be easily used for field measurements aboard oceanographic ships.
Resumo:
The interactions between outdoor bronzes and the environment, which lead to bronze corrosion, require a better understanding in order to design effective conservation strategies in the Cultural Heritage field. In the present work, investigations on real patinas of the outdoor monument to Vittorio Bottego (Parma, Italy) and laboratory studies on accelerated corrosion testing of inhibited (by silane-based films, with and without ceria nanoparticles) and non-inhibited quaternary bronzes are reported and discussed. In particular, a wet&dry ageing method was used both for testing the efficiency of the inhibitor and for patinating bronze coupons before applying the inhibitor. A wide range of spectroscopic techniques has been used, for characterizing the core metal (SEM+EDS, XRF, AAS), the corroded surfaces (SEM+EDS, portable XRF, micro-Raman, ATR-IR, Py-GC-MS) and the ageing solutions (AAS). The main conclusions were: 1. The investigations on the Bottego monument confirmed the differentiation of the corrosion products as a function of the exposure geometry, already observed in previous works, further highlighting the need to take into account the different surface features when selecting conservation procedures such as the application of inhibitors (i.e. the relative Sn enrichment in unsheltered areas requires inhibitors which effectively interact not only with Cu but also with Sn). 2. The ageing (pre-patination) cycle on coupons was able to reproduce the relative Sn enrichment that actually happens in real patinated surfaces, making the bronze specimens representative of the real support for bronze inhibitors. 3. The non-toxic silane-based inhibitors display a good protective efficiency towards pre-patinated surfaces, differently from other widely used inhibitors such as benzotriazole (BTA) and its derivatives. 4. The 3-mercapto-propyl-trimethoxy-silane (PropS-SH) additivated with CeO2 nanoparticles generally offered a better corrosion protection than PropS-SH.