924 resultados para Truman, Harry S.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify the effects of laser energy on intracanal dentin surfaces, by analyzing the morphologic changes and removal of debris in the apical third of 30 extracted human teeth, prepared and irradiated with the Nd:YAG laser and diode laser. Background Data: Lasers have been widely used in endodontics. The morphologic changes in dentin walls caused by Nd: YAG and diode laser irradiation could improve apical seals and cleanliness. Materials and Methods: The protocol used for Nd: YAG laser irradiation was 1.5 W, 100 mJ, and 15 Hz, in pulsed mode, and for diode laser was 2.5 W in continuous mode. Each specimen was irradiated four times at a speed of 2 mm/sec with a 20-sec interval between applications. Five calibrated examiners scored the morphologic changes and debris removal on a 4-point scale. Results: In analyzing the scores, there were no statistically significant differences between the two types of laser for either parameter, according to Kruskal-Wallis testing at p = 0.05. The SEM images showed fusion and resolidification of the dentin surface, with partial removal of debris on the specimens irradiated with the Nd: YAG laser and the diode laser, compared with controls. Conclusion: Both lasers promote morphologic changes and debris removal. These alterations of the dentin surface appeared to be more evident in the Nd: YAG laser group, but the diode laser group showed more uniform changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the influence of 810-nm-diode laser irradiation, applied before root canal filling, on apical sealing ability of three different resin-based sealers (AH Plus, EndoRez, and RealSeal). Background: Lasers have been widely used in endodontics. The dentin wall changes caused by laser irradiation could improve the sealing ability of endodontic cements. Methods: Sixty single-rooted human teeth were divided into six groups, according to the endodontic sealer used and previous 810-nm-diode laser irradiation. The protocol for laser irradiation was 2.5W in a continuous wave, in scanning mode, with four irradiations per tooth. After sample preparation, they were analyzed according to apical leakage with silver nitrate impregnation. Results: The RealSeal sealer achieved minimum leakage rates (1.24 mm), with significant differences at the 1% level (Tukey's test, p < 0.01) from AH Plus (1.84 mm) in nonirradiated groups. When the laser was used, there were also significant differences at the 5% level (p < 0.05) between irradiated groups (1.31 and 1.78 mm, respectively). Conclusion: The 810-nm-diode laser irradiation did not promote significant differences in apical leakage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Measurement of the transmitted intensity from a coherent monomode light source through a series of subwavelength slit arrays in Ag films, with varying array pitch and number of slits, demonstrates enhancement (suppression) by factors of as much as 6 (9) when normalized to the transmission efficiency of an isolated slit. Pronounced minima in the transmitted intensity are observed at array pitches corresponding to lambda(SPP), 2 lambda(SPP), and 3 lambda(SPP), where lambda(SPP) is the wavelength of the surface plasmon polariton (SPP). The position of these minima arises from destructive interference between incident propagating waves and pi-phase-shifted SPP waves. Increasing the number of slits to four or more does not increase appreciably the per-slit transmission intensity. A simple interference model fits well the measured transmitted intensity profile.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to quantify the mass transfer velocity using turbulence parameters from simultaneous measurements of oxygen concentration fields and velocity fields. The surface divergence model was considered in more detail, using data obtained for the lower range of beta (surface divergence). It is shown that the existing models that use the divergence concept furnish good predictions for the transfer velocity also for low values of beta, in the range of this study. Additionally, traditional conceptual models, such as the film model, the penetration-renewal model, and the large eddy model, were tested using the simultaneous information of concentration and velocity fields. It is shown that the film and the surface divergence models predicted the mass transfer velocity for all the range of the equipment Reynolds number used here. The velocity measurements showed viscosity effects close to the surface, which indicates that the surface was contaminated with some surfactant. Considering the results, this contamination can be considered slight for the mass transfer predictions. (C) 2009 American Institute of Chemical Engineers AIChE J, 56: 2005-2017; 2010

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Darcy-Weisbach equation was used in the analysis of flow over spillways, furnishing theoretical tools to design stilling basins. Predictions for the length of hydraulic jump stilling basins downstream of stepped and smooth spillways are presented, together with ranges of values for the Darcy-Weisbach friction factor of both spillways. The experimental data were compared with results of the theoretical solution of the gradually varied flow equation. All comparisons were made in non-dimensional form. The values of the Darcy-Weisbach friction factor were roughly five times smaller for smooth spillways than for stepped spillways. The theoretical predictions and the experimental data allow to present approximate equations for a preliminary evaluation of the length and the bed level of hydraulic jump stilling basins. In the same way, approximate equations were presented for the evaluation of the friction factor in smooth and stepped spillways, as a function of the Froude number at the downstream cross-section.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Air concentration measurements performed along the lower nappe of a bottom aerator through the impact and downstream flow regions permitted the calculation of air entrainment along the jet length. The air uptake was also measured in the air supply conduit. It was shown that integration of the concentration profiles along the jet overestimates the air uptake measured in the air supply conduit. Corrective procedures were developed by adapting the concept of entrained and entrapped air, in which the latter is re-circulated in the cavity, but both are measured by air concentration probes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow chamber was used to impart a steady laminar shear stress on a recombinant Chinese hamster ovary (CHO) cell line expressing human growth hormone (hGH). The cells were subjected to shear stress ranging from 0.005 to 0.80 N m(-2). The effect of shear stress on the cell specific glucose uptake, cell specific hGH, and lactate productivity rates were calculated. No morphological changes to the cells were observed over the range of shear stresses examined. When the cells were subjected to 0.10 N m(-2) shear in protein-free media without Pluronic F-68, recombinant protein production ceased with no change in cell morphology, whereas control cultures were expressing hGH at 0.35 mug/10(6) cells/h. Upon addition of the shear protectants, Pluronic F-68 (0.2% [w/v]) or fetal bovine serum (1.0% [v/v] FBS), the productivity of the cells was restored. The effect of increasing shear stress on the cells in protein-free medium containing Pluronic F-68 was also investigated. Cell specific metabolic rates were calculated for cells under shear stress and for no-shear control cultures performed in parallel, with shear stress rates expressed as a percentage of those obtained for control cultures. Upon increasing shear from 0.005 to 0.80 N m(-2), the cell specific hGH productivity decreased from 100% at 0.005 N m(-2) to 49% at 0.80 N m(-2) relative to the no-shear control. A concurrent increase in the glucose uptake rate from 115% at 0.01 N m(-2) to 142% at 0.80 N m(-2), and decreased lactate productivity from 92% to 50%, revealed a change in the yield of products from glucose compared with the static control. It was shown that shear stress, at sublytic levels in medium containing Pluronic F-68, could decrease hGH specific productivity. (C) 2002 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Percutaneous transluminal coronary angioplasty is a frequently used interventional technique to reopen arteries that have narrowed because of atherosclerosis. Restenosis, or renarrowing of the artery shortly after angioplasty, is a major limitation to the success of the procedure and is due mainly to smooth muscle cell accumulation in the artery wall at the site of balloon injury. In the present study, we demonstrate that the antiangiogenic sulfated oligosaccharide, PI-88, inhibits primary vascular smooth muscle cell proliferation and reduces intimal thickening 14 days after balloon angioplasty of rat and rabbit arteries. PI-88 reduced heparan sulfate content in the injured artery wall and prevented change in smooth muscle phenotype. However, the mechanism of PI-88 inhibition was not merely confined to the antiheparanase activity of this compound. PI-88 blocked extracellular signal-regulated kinase-1/2 (ERK1/2) activity within minutes of smooth muscle cell injury. It facilitated FGF-2 release from uninjured smooth muscle cells in vitro, and super-released FGF-2 after injury while inhibiting ERK1/2 activation. PI-88 inhibited the decrease in levels of FGF-2 protein in the rat artery wall within 8 minutes of injury. PI-88 also blocked injury-inducible ERK phosphorylation, without altering the clotting time in these animals. Optical biosensor studies revealed that PI-88 potently inhibited (K-i 10.3 nmol/L) the interaction of FGF-2 with heparan sulfate. These findings show for the first time the capacity of this sulfated oligosaccharide to directly bind FGF-2, block cellular signaling and proliferation in vitro, and inhibit injury-induced smooth muscle cell hyperplasia in two animal models. As such, this study demonstrates a new role for PI-88 as an inhibitor of intimal thickening after balloon angioplasty. The full text of this article is available online at http://www.circresaha.org.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: We compared 12-month outcomes, regarding ischemic events, repeat intervention, and ST, between diabetic and nondiabetic patients treated with the Genous (TM) EPC capturing R stent (TM) during routine nonurgent percutaneous coronary intervention (PCI) using data from the multicenter, prospective worldwide e-HEALING registry. Background: Diabetic patients have an increased risk for restenosis and stent thrombosis (ST). Methods: In the 4,996 patient e-HEALING registry, 273 were insulin requiring diabetics (IRD), 963 were non-IRD (NIRD), and 3,703 were nondiabetics. The 12-month primary outcome was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction (MI) and target vessel revascularization. Secondary outcomes were the composite of cardiac death, MI or target lesion revascularization (TLR), and individual outcomes including ST. Cumulative event rates were estimated with the Kaplan-Meier method and compared with a log-rank test. Results: TVF rates were respectively 13.4% in IRD, 9.0% in NIRD, and 7.9% in nondiabetics (P < 0.01). This was mainly driven by a higher mortality hazard in IRD (P < 0.001) and NIRD (P = 0.07), compared with nondiabetics. TLR rates were comparable in NIRD and nondiabetics, but significantly higher in IRD (P = 0.04). No difference was observed in ST. Conclusion: The 1-year results of the Genous stent in a real-world population of diabetics show higher TVF rates in diabetics compared with nondiabetics, mainly driven by a higher mortality hazard. IRD is associated with a significant higher TLR hazard. Definite or probable ST in all diabetic patients was comparable with nondiabetics. (J Interven Cardiol 2011;24:285-294)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: e-HEALING is a worldwide, internet-based registry designed to capture post marketing clinical data on the use of the Genous (TM) EPC capturing R stent (TM). Rapid restoration of a healthy endothelial layer after stent placement by capturing circulating endothelial progenitor cells may reduce both stent thrombosis (ST) and in-stent-restenosis. Methods and results: We planned a 5,000 patient registry with >= 1 lesion suitable for stenting. The 12-month primary outcome was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction (MI) and target vessel revascularisation. Secondary outcomes were the composite of cardiac death, MI or target lesion revascularisation (TLR), and individual outcomes including ST. A total of 4,939 patients received >= 1 Genous stent between 2005 and 2007. Baseline characteristics showed a median age of 63 years, 79% males, 25% diabetics, and 37% with prior MI. A total of 49% of lesions treated were ACC/AHA type B2 or C; 1.1 stents per lesion were used. At 12 months, TVF occurred in 8.4% and the composite of cardiac death, MI or TLR in 7.9%. Twelve-month TLR and ST were 5.7% and 1.1%, respectively. Conclusions: Coronary stenting with the Genous results in good clinical outcomes, and low incidences of repeat revascularisation and ST.