770 resultados para Tablets


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The analytical method of high performance liquid chromatography (HPLC) for the assay of benznidazole in tablets was developed and validated following the requirements of regulatory agencies. The method used as mobile phase acetonitrile:wather 1:1, a C18 column of 12.5 cm length x 4 mm id, 5 mm particles and lambda=316 nm. The statistical analysis of the results demonstrated that the method satisfies all parameters so as to be considered a safe and efficient analytical alternative of low cost for laboratory routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El lanzamiento de las tabletas, especialmente la iPad de Apple en 2010, abrió la competencia entre las compañías de comunicación en el sentido de hacer disponible el contenido para este entorno de medios emergentes. La fuga de lectores de periódicos impresos y la consecuente caída en las ganancias por publicidad, forzó a las compañías periodísticas a que buscaran los otros medios de mantener sus negocios. La diversificación de productos y la penetración de los periódicos en dispositivos móviles constituyen un escenario prometedor para el medio. El vertiginoso volumen de ventas de las tabletas indica que en 2012 serán comercializadas más de 140 millones de unidades en el mundo. El diseño de los periódicos en tabletas está íntimamente ligado al diseño de la versión impresa por la fuerza de su metáfora. El desafío es encontrar un diseño de páginas propio, aprovechando el potencial multimedia sin interferir negativamente en la legibilidad y en el carácter intrínseco de informar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Una de las prácticas de laboratorio de Tecnología Farmacéutica requiere la elaboración de comprimidos en la asignatura de Farmacia Galénica II siguiendo el mismo flujo de fabricación al empleado en la industria farmacéutica (pesada, tamización, mezclado, amasado, granulación, secado, mezclado y compresión). Estos comprimidos se analizan en la asignatura de Farmacia Galénica III (entre 6 y 12 meses más tarde) por los mismos alumnos según las directrices de la Real Farmacopea Española.En el trabajo se exponen gráficamente los resultados hallados y se comentan los principales puntos de mejora ya que el producto elaborado no es conforme en la mayoría de los casos (sólo alrededor del 50% de los productos elaborados por los alumnos podrían ser conformes, aún siendo un proceso validado). Realmente, la experiencia de los operadores es el punto más crítico que influye en los resultados de estos lotes de comprimidos, sobre todo en el laboratorio analítico. Esta hipótesis ha sido confirmada en lotes analizados por el personal cualificado del departamento de control de calidad del Servei de Desenvolupament del Medicament de la Facultat de Farmàcia de la Universitat de Barcelona, ya que en todos los casos los resultados obtenidos fueron más exactos, repetitivos y cercanos a los teóricos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the development and validation of simple and selective analytical method for determination of 3.4-methylenedioxymethamphetamine (MDMA) in Ecstasy tablets, using high performance liquid chromatography with fluorescence detection. Analysis was performed in a reversed phase column (LiChrospher 100 C18, 150 x 4.6 mm, 5 µm), isocratic elution with phosphate buffer 25 mmol/L pH 3.0 and acetonitrile (95:5, v/v). The method presents adequate linearity, selectivity, precision and accuracy. MDMA concentration in analyzed tablets showed a remarkable variability (from 8.5 to 59.5 mg/tablet) although the tablet weights were uniform, indicating poor manufacturing control thus imposing additional health risks to the users.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Celecoxib (CB) and lumiracoxib (LM) are potent COX-2 inhibitors widely marketed for the treatment of rheumatoid arthritis and osteoarthritis. Nevertheless, it is difficult to obtain because it are protected under patents. The aim of this work was to develop an extraction method of drugs, CB and LM, in order to obtain the drug with a purity degree appropriated for use in research projects. The developed method showed to be effective of both drugs, becoming interesting due to its low cost, easy and speed of execution, application to different dosage forms (capsules and tablets) and drugs with different physicochemical properties.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spectrophotometric methods of zero order, first and second derived order had been developed for olanzapine determination in tablets using ethanol and isopropanol as solvent. The two solvents revealed to be adequate. For the three methods the calibration curve coefficient of correlation had been greater than 0.9998 with limit of detection varying from 0.068 to 0.190 mg L-1, in ethanol, and 0.026 to 0.205 mg L-1, in isopropanol. The inter-day precision was inferior to 1.1 and 1.9 mg L-1 for ethanol and isopropanol, respectively. The average recoveries varied from 98 to 101%, in ethanol and 99 to 103% in isopropanol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Designer drug is a term used to describe psychoactive drugs of abuse which are usually synthesized by modifying the molecular structures of existing drugs of abuse. The term gained widespread popularity when MDMA (ecstasy) experienced a popularity boom in the mid 1980´s. In Brazil, designer drugs seizures have increased in the last few years, and actually tablets with unknown psychoactive compounds began to be forwarded to the Forensic Laboratories. This work describes the analytical assays that were performed to identify the chlorophenylpiperazine, a psychoactive substance first time identified in seized tablets in Sao Paulo state.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid, economical, reproducible, and simple direct spectrophotometric method was developed and validated for the assay of nitazoxanide in pharmaceutical formulations. Nitazoxanide concentration was estimated in water at 345 nm and pH 4.5. The method was suitable and validated for specificity, linearity, precision, and accuracy. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. The proposed method was successfully applied in the determination of nitazoxanide in coated tablets and in powders for oral suspension. This method was compared to a previously developed and validated method for liquid chromatography to the same drug. There was no significative difference between these methods for nitazoxanide quantitation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.