892 resultados para Location precision


Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray diffraction and Rutherford backscattering/channeling were used to characterize the crystalline quality of an InN layer grown on Al2O3(0001) Using metal-organic chemical-vapor deposition. A full width at half maximum of 0.27 degrees from an InN(0002) omega scan and a minimum yield of 23% from channeling measurements show that this 480-nm-thick InN layer grown at low temperature (450 degrees C) has a relatively good crystalline quality. High-resolution x-ray diffraction indicates that the InN layer contains a small fraction of cubic InN, besides the predominant hexagonal phase. From this InN sample, the lattice constants a=0.353 76 nm and c=0.570 64 nm for the hexagonal InN and a=0.4986 nm for the cubic InN were determined independently. 2 theta/omega-chi mapping and a pole figure measurement revealed that the crystallographic relationship among the cubic InN, the hexagonal InN, and the substrate is: InN[111]parallel to InN[0001]parallel to Al2O3[0001] and InN{110}parallel to InN{1120}parallel to Al2O3{1010}, and that the cubic InN is twinned. Photoluminescence measurements indicate that the band-gap energy of this sample is approximately 0.82 eV. (c) 2006 American Vacuum Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a robust face location system based on human vision simulations to automatically locate faces in color static images. Our method is divided into four stages. In the first stage we use a gauss low-pass filter to remove the fine information of images, which is useless in the initial stage of human vision. During the second and the third stages, our technique approximately detects the image regions, which may contain faces. During the fourth stage, the existence of faces in the selected regions is verified. Having combined the advantages of Bottom-Up Feature Based Methods and Appearance-Based Methods, our algorithm performs well in various images, including those with highly complex backgrounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of image restoration is to restore the original clear image from the existing blurred image without distortion as possible. A novel approach based on point location in high-dimensional space geometry method is proposed, which is quite different from the thought ways of existing traditional image restoration approaches. It is based on the high-dimensional space geometry method, which derives from the fact of the Principle of Homology-Continuity (PHC). Begin with the original blurred image, we get two further blurred images. Through the regressive deducing curve fitted by these three images, the first iterative deblured image could be obtained. This iterative "blurring-debluring-blurring" process is performed till reach the deblured image. Experiments have proved the availability of the proposed approach and achieved not only common image restoration but also blind image restoration which represents the majority of real problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Penning trap, which can measure the atomic masses with the highest precision, is one of the most important facilities in nuclear physics research nowadays. The precision mass data play an important role in the studies of nuclear models, mass formulas, nuclear synthesis processes in the nuclear astrophysics, symmetries of the weak interaction and the conserved vector current (CVC) hypothesis. The status of high precision mass measurement around the world, the basic principle of Penning trap and the basic information about the LPT (Lanzhou Penning Trap) are introduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectra of the ionized oxygen atom were researched with the Pro-500i monochromator equipped with CCD. The beam foil method was used at energy of 2 MeV in a 2 x 1.7 Tandem accelerator. In this work, we report 201 spectral lines determined in the region 250-350 nm, and most spectral lines were attributed to n, l energy level transitions from O II to O IV atoms. Our experimental results are in good agreement with existing theoretical calculations. Many lines reported in this paper have not been measured in past experiments, and a majority of them are week transitional lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

在发展髙性能多路小型化前端电路方面,阐述了一种用于测试时间的系统电路的设计与实现。其突出特点是转换速度快,电路结构简单,输入信号范围大、精度高、功耗低,电路采用改进的TAC方法,用于处理快速的时间信号,利用高速DMOS开关,并优化控制逻辑时序,极大提高了测试精度。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Natl Chiao Tung Univ, Dept Comp Sci

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is found that the nitro substituent of some aromatic bifunctional compounds shows unusual reactivity towards protonation. In the chemical ionization mass spectra of nitrobenzoic acids and their esters and amides, and of nitrophenols and their ethers, protonations on the carboxyl, ester, amide, hydroxyl or alkoxyl groups are highly suppressed by that on the nitro group. As a result, fragmentations based on protonation on these groups unexpectedly become negligible. Ortho effects were observed for all the ortho isomers where the initial protonation on the nitro group is followed by an intramolecular proton transfer reaction, which leads to the expected 'normal' fragmentations. Protonation on the nitro substituent is much more favourable in energy than on any of the other substituents. The interaction of the two substituents through the conjugating benzene ring is found to be responsible for this 'unfair' competitive protonation. The electron-attracting nitro group strongly destabilizes the MH+ ions formed through protonation on the other substituent; although the COR (R = OH, OMe, OEt, NH2) groups are also electron-withdrawing, their effects are weaker than that of NO2; thus protonation on the latter group produces more-stable MH+ ions. On the other hand, an electron-releasing group OR (R = H, Me, Et) stabilizes the nitro-protonated species; the stronger the electron-donating effect of this group the more stable the nitro-protonated ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

文中研究的相关跟踪技术主要应用于飞航导弹的末制导。现阶段,激光制导技术、GPS制导技术、合成孔径雷达(SAR)制导技术在我国的实际应用还不成熟,传统的电视、红外制导技术仍然具有很强的生命力,因而,基于可见光的视频相关跟踪技术具有重要的研究价值。本文主要论述的两种相关算法是:多灰度点相关(MPC)、区域模板相关(RTC)。其中多点相关(MPC)算法的跟踪灵敏度高,定位精度好,硬件实现比较方便,实时性能好;区域模板相关算法(RTC),在图像的匹配过程中,不仅考虑了目标区域的灰度特征,而且兼顾了区域里多灰度层次的位置特征、面积特征,算法具有很好的鲁棒性。文中深入研究了两种相关跟踪算法,并针对它们在实际应用中的不足,提出了有效的改善措施。最后,本文对两种相关跟踪算法进行了初步融合,一是:通过粗匹配、精匹配过程来选取目标跟踪点;二是:提出了一种度量模板更新的能量准则函数。大量的仿真实验结果表明:改进后的两种相关跟踪技术可以较好地完成一些复杂背景下的目标跟踪任务,两种算法的有效结合又进一步提高了目标跟踪的稳定性能和可靠性能。本文研究的一些相关跟踪技术已经运用到实际工程项目中。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PSD是一种高分辨率、实时性好的光电位置敏感器件,因而具有广泛应用的前景.但在光照度变化条件下,输出信号存在非线性飘移,因而影响了作为位置检测传感器的检测精度,尤其在3D测量时适用性受到了限制.针对这个问题,提出了一种PSD位置传感器的非线性误差补偿方法.该方法针对目标的空间距离变化所产生的PSD输出非线性飘移,采用归一化模型进行误差修正,很大程度上改进了PSD的输出一致性,使基于PSD的3D测量系统性能得以提高.