First charge collection and position-precision data on the medium-resistivity silicon strip detectors before and after neutron irradiation up to 2x10(14) n/cm(2)


Autoria(s): Li Z; Dezilllie B; Eremin V; Li CJ; Verbitskaya E
Data(s)

1999

Resumo

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

于2010-11-15批量导入

zhangdi于2010-11-15 17:02:32导入数据到SEMI-IR的IR

Made available in DSpace on 2010-11-15T09:02:32Z (GMT). No. of bitstreams: 1 3015.pdf: 439849 bytes, checksum: 9feb002c02d7a3cfab1fdd4fce186ba4 (MD5) Previous issue date: 1999

Univ Florence.; Ist Nazl Fis Nucl.

Brookhaven Natl Lab, Upton, NY 11973 USA; RAS, AF Ioffe Physicotech Inst, St Petersburg, Russia; Chinese Acad Sci, Inst Semicond, Beijing 100083, Peoples R China

Univ Florence.; Ist Nazl Fis Nucl.

Identificador

http://ir.semi.ac.cn/handle/172111/15047

http://www.irgrid.ac.cn/handle/1471x/105241

Idioma(s)

英语

Publicador

ELSEVIER SCIENCE BV

PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS

Fonte

Li Z; Dezilllie B; Eremin V; Li CJ; Verbitskaya E .First charge collection and position-precision data on the medium-resistivity silicon strip detectors before and after neutron irradiation up to 2x10(14) n/cm(2) .见:ELSEVIER SCIENCE BV .NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 426 (1),PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDS ,1999,38-46

Palavras-Chave #半导体物理 #strip detectors #silicon detectors #annealing #simulation #irradiation #N-EFF #JUNCTION DETECTORS #RADIATION-DAMAGE #MODELS
Tipo

会议论文