929 resultados para Infrasound and low frequency noise-exposure
Resumo:
OBJECTIVES: We assessed the clinical characteristics of patients with acute ischemic stroke (AIS) with left ventricular ejection fraction (EF) ≤ 35% and investigated the association of low EF with early and long-term outcome. METHODS: A total of 2439 patients of the Acute Stroke Registry and Analysis of Lausanne (ASTRAL) were selected. Demographics, risk factors, pre-stroke treatment, and clinical, radiological and metabolic variables in patients with and without low EF were compared. Functional independence (modified Rankin Score ≤ 2) and mortality were recorded 1 week up to 12 months from admission. RESULTS: Low EF patients (n=119) were more commonly men, older, had higher rates of coronary artery disease and atrial fibrillation (AF), and more frequent pretreatment with anticoagulants, antiplatelets and antihypertensive agents. On admission, they presented with higher stroke severity and had lower values of systolic blood pressure, higher heart rate, and worse estimated glomerular filtration rate. Stroke-related disability and death rates were higher in low EF patients during follow-up (19.5% vs. 7.8% at 1 week, and 36.1% vs. 16.5% at 12 months). Increasing age, stroke severity, and AF were independent predictors of one-year mortality in these patients while prior use of statins had a favorable effect on early mortality. CONCLUSIONS: AIS in patients with low EF is associated with older age, cardiac comorbidities, and more severe clinical presentation. Low EF can identify a subset of AIS patients at high risk of early and long-term functional disability and mortality.
Resumo:
Many rural communities have developed around highways or major county roads; as a result, the main street through small rural communities is often part of a high-speed rural highway. Highways and county roads are characterized by high speeds outside the city limits; they then transition into a reduced speed section through the rural community. Consequently, drivers passing through the community often enter at high speeds and maintain those speeds as they travel through the community. Traffic calming in small rural communities along major roadways is common in Europe, but the U.S. does not have experience with applying traffic-calming measures outside of major urban areas. The purpose of the project was to evaluate traffic-calming treatments on the major road through small Iowa communities using either single-measure low-cost or gateway treatments. The project was partially funded by the Iowa Highway Research Board (IHRB). The focus of the IHRB portion was to evaluate single-measure, low-cost, traffic-calming measures that are appropriate to major roads through small rural communities. Seven different low-cost traffic treatments were implemented and evaluated in five rural Iowa communities. The research evaluated the use of two gateway treatments in Union and Roland; five single-measure treatments (speed table, on-pavement “SLOW” markings, a driver speed feedback sign, tubular markers, and on-pavement entrance treatments) were evaluated in Gilbert, Slater, and Dexter.
Resumo:
Descriptors: music performance anxiety, respiration, hyperventilation Surveys indicate that high-anxious musicians may suffer from hyperventilation (HV) before or during performance. Reported symptoms include shortness of breath, fast/ deep breathing and thumping heart. However, no study has yet tested if these selfreported symptoms reflect actual cardiorespiratory activity. Themain goal of this study was to determine if MPA is manifested physiologically in specific correlates of cardiorespiratory activity associated with HV.We studied 74 professional music students from Swiss Music Academies. In this study, we compared the most anxious students (highanxious; n 5 20) with the least anxious students (low-anxious; n 5 23) based on their self-reported performance anxiety. We measured cardiorespiratory patterns with the Lifeshirt system, end-tidal CO2 with a capnograph (EtCO2, a good non-invasive estimator of HV), self-perceived physiological activation and affective experience in three situations on different days: baseline, performance without audience, and performance with audience. Comparing measures for the private vs. the public concert, high- compared to low-anxious students showed a significant drop in EtCO2 before the public concert and reported larger increases in anxiety, tension, palpitations and breathing difficulties. In contrast, heart rate, respiratory rate and volume did not differ significantly between groups. The results of this study support the hypothesis thatMPA may be associated with a tendency to hyperventilate and, thus, point to a potential hyperventilation problem in high-anxious music students.
Resumo:
In the last two decades, anti-cancer vaccines have yielded disappointing clinical results despite the fact that high numbers of self/tumor-specific T cells can be elicited in immunized patients. Understanding the reasons behind this lack of efficacy is critical in order to design better treatment regimes. Recombinant lentivectors (rLVs) have been successfully used to induce antigen-specific T cells to foreign or mutated tumor antigens. Here, we show that rLV expressing a murine nonmutated self/tumor antigen efficiently primes large numbers of self/tumor-specific CD8(+) T cells. In spite of the large number of tumor-specific T cells, however, no anti-tumor activity could be measured in a therapeutic setting, in mice vaccinated with rLV. Accumulating evidence shows that, in the presence of malignancies, inhibition of T-cell activity may predominate overstimulation. Analysis of tumor-infiltrating lymphocytes revealed that specific anti-tumor CD8(+) T cells fail to produce cytokines and express high levels of inhibitory receptors such as programmed death (PD)-1. Association of active immunization with chemotherapy or antibodies that block inhibitory pathways often leads to better anti-tumor effects. We show here that combining rLV vaccination with either cyclophosphamide or PD-1 and PD-L1 blocking antibodies enhances rLV vaccination efficacy and improves anti-tumor immunity.
Resumo:
The cardiovascular system is under the control of the circadian clock, and disturbed circadian rhythms can induce cardiovascular pathologies. This cyclic regulation is probably brought about by the circadian expression of genes encoding enzymes and regulators involved in cardiovascular functions. We have previously shown that the rhythmic transcription of output genes is, in part, regulated by the clock-controlled PAR bZip transcription factors DBP (albumin D-element Binding Protein), HLF (Hepatic Leukemia Factor), and TEF (Thyrotroph Embryonic Factor). The simultaneous deletion of all three PAR bZip transcription factors leads to increased morbidity and shortened life span. Here, we demonstrate that Dbp/Tef/Hlf triple knockout mice develop cardiac hypertrophy and left ventricular dysfunction associated with a low blood pressure. These dysfunctions are exacerbated by an abnormal response to this low blood pressure characterized by low aldosterone levels. The phenotype of PAR bZip knockout mice highlights the importance of circadian regulators in the modulation of cardiovascular functions.
Resumo:
We show that in the limit of a large number of dimensions a wide class of nonextremal neutral black holes has a universal near-horizon limit. The limiting geometry is the two-dimensional black hole of string theory with a two-dimensional target space. Its conformal symmetry explains the properties of massless scalars found recently in the large-D limit. For black branes with string charges, the near-horizon geometry is that of the three-dimensional black strings of Horne and Horowitz. The analogies between the α′ expansion in string theory and the large-D expansion in gravity suggest a possible effective string description of the large-D limit of black holes. We comment on applications to several subjects, in particular to the problem of critical collapse.
'Royal Gala' apple quality stored under ultralow oxygen concentration and low temperature conditions
Resumo:
The objective of this work was to evaluate the interaction of ultralow oxygen concentrations (ULO) with storage temperatures and carbon dioxide partial pressures and its influence on fruit quality preservation and on the occurrence of physiological disorders in 'Royal Gala' apples. The experiment was carried out in a completely randomized design, with four replicates 25-fruit. ULO conditions (1.0 kPa O2 + 2.0 kPa CO2; 0.8 kPa O2 + 1.5 kPa CO2; 0.8 kPa O2 + 1.0 kPa CO2; 0.6 kPa O2 + 1.5 kPa CO2; and 0.6 kPa O2 + 1.0 kPa CO2) were tested at 0, 0.5 and 1.0°C, in a 5x3 factorial arrangement. Fruit quality and ripening analyses were performed after eight-month storage plus seven days of shelf-life at 20°C. Oxygen partial pressures below 0.8 kPa increased the occurrence of internal breakdown and mealiness. The best ULO condition was 1.0 kPa O2 + plus 2.0 kPa CO2 at 1.0°C. The interaction of ULO conditions and storage temperatures shows the need of increasing O2 partial pressure at higher storage temperatures.
Resumo:
A 47-year-old male taxi driver experienced multiple adverse drug reactions during therapy with clomipramine (CMI) and quetiapine for major depressive disorder, after having been unsuccessfully treated with adequate doses of mirtazapine and venlafaxine. Drug serum concentrations of CMI and quetiapine were significantly increased and pharmacogenetic testing showed a poor metabolizer status for CYP2D6, low CYP3A4/5 activity and normal CYP2C19 genotype. After reduction of the CMI dose and discontinuation of quetiapine, all ADR subsided except for the increase in liver enzymes. The latter improved but did not normalize completely, even months later, possibly due to concomitant cholelithiasis.
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.
Resumo:
Among adolescents, overweight, obesity and metabolic syndrome are rapidly increasing in recent years as a consequence of unhealthy palatable diets. Animal models of diet-induced obesity have been developed, but little is known about the behavioural patterns produced by the consumption of such diets. The aim of the present study was to determine the behavioural and biochemical effects of a cafeteria diet fed to juvenile male and female rats, as well as to evaluate the possible recovery from these effects by administering standard feeding during the last week of the study. Two groups of male and female rats were fed with either a standard chow diet (ST) or a cafeteria (CAF) diet from weaning and for 8 weeks. A third group of males (CAF withdrawal) was fed with the CAF diet for 7 weeks and the ST in the 8th week. Both males and females developed metabolic syndrome as a consequence of the CAF feeding, showing overweight, higher adiposity and liver weight, increased plasma levels of glucose, insulin and triglycerides, as well as insulin resistance, in comparison with their respective controls. The CAF diet reduced motor activity in all behavioural tests, enhanced exploration, reduced anxiety-like behaviour and increased social interaction; this last effect was more pronounced in females than in males. When compared to animals only fed with a CAF diet, CAF withdrawal increased anxiety in the open field, slightly decreased body weight, and completely recovered the liver weight, insulin sensitivity and the standard levels of glucose, insulin and triglycerides in plasma. In conclusion, a CAF diet fed to young animals for 8 weeks induced obesity and metabolic syndrome, and produced robust behavioural changes in young adult rats, whereas CAF withdrawal in the last week modestly increased anxiety, reversed the metabolic alterations and partially reduced overweight.
Resumo:
Article sobre la tolerància a la sequera i les necessitats de llum d'espècies de l'alt i baix sublitoral de macroalgues de la Mediterrània del gènere Cystoseira C. Agardh (Fucales, Phaeophyceae)
Resumo:
Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.