940 resultados para X-ray method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal analysis, powder diffraction, and Raman scattering as a function of the temperature were carried out on K2BeF4. Moreover, the crystal structure was determined at 293 K from powder diffraction. The compound shows a transition from Pna21 to Pnam space group at 921 K with a transition enthalpy of 5 kJ/mol. The transition is assumed to be first order because the compound shows metastability. Structurally and spectroscopically the transition is similar to those observed in (NH4)2SO4, which suggests that the low-temperature phase is ferroelectric. In order to confirm it, the spontaneous polarization has been computed using an ionic model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The oxidation of GaAs and AlGaAs targets subjected to O2+ bombardment has been analyzed, using in situ x¿ray photoelectron spectroscopy, as a function of time until steady state is reached. The oxides formed by the O2+ bombardment have been characterized in terms of composition and binding energy. A strong energy and angular dependence for the oxidation of As relative to Ga is found. Low energies as well as near normal angles of incidence favor the oxidation of As. The difference between Ga and As can be explained in terms of the formation enthalpy for the oxide and the excess supply of oxygen. In an AlGaAs target the Al is very quickly completely oxidized irrespective of the experimental conditions. The steady state composition of the altered layers show in all cases a preferential removal of As.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Peripheral assessment of bone density using photon absorptiometry techniques has been available for over 40 yr. The initial use of radio-isotopes as the photon source has been replaced by the use of X-ray technology. A wide variety of models of single- or dual-energy X-ray measurement tools have been made available for purchase, although not all are still commercially available. The Official Positions of the International Society for Clinical Densitometry (ISCD) have been developed following a systematic review of the literature by an ISCD task force and a subsequent Position Development Conference. These cover the technological diversity among peripheral dual-energy X-ray absorptiometry (pDXA) devices; define whether pDXA can be used for fracture risk assessment and/or to diagnose osteoporosis; examine whether pDXA can be used to initiate treatment and/or monitor treatment; provide recommendations for pDXA reporting; and review quality assurance and quality control necessary for effective use of pDXA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ironstones or petroplinthites are common materials in soils under humid tropical climate, generally defined as the result of Fe oxide accumulation in areas where the water table oscillates, and may exhibit considerable morphological variability. The aim of this study was to examine the internal structure and porosity of an ironstone fragment from a Petroferric Acrudox in Minas Gerais, Brazil, by computed tomography (CT) and conventional techniques. The sample analyzed had total porosity of 59.5 %, with large macropores in the form of tubular channels and irregular vughs, the latter with variable degrees of infilling by material released from the ironstone walls or the soil matrix. The CT scan also showed that the ironstone has wide variation in the density of the solid phase, most likely due to higher concentrations or thick intergrowths of hematite and magnetite/maghemite, especially in its outer rims. The implications of these results for water retention and soil formation in ironstone environments are briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of the soil pore system represents an important way of characterizing soil structure. Properties such as the shape and number of pores can be determined through soil pore evaluations. This study presents a three-dimensional (3D) characterization of the shape and number of pores of a sub-tropical soil. To do so, a second generation X-ray microtomograph equipped with a plain type detector was employed. A voltage of 120 kV and current of 80 mA was applied to the X-ray tube. The soil samples analyzed were collected at three different depths (0-10, 10-20, and 20-30 cm). The results obtained allowed qualitative (images) and quantitative (3D) analyses of the soil structure, revealing the potential of the microtomographic technique, as well as the study of differences in soil macroporosity at different depths. Macroporosity was 5.14 % in the 0-10 cm layer, 5.10 % in the 10-20 cm layer, and 6.64 % in the 20-30 cm layer. The macroporosity of unclassified pores (UN) was 0.30 % (0-10 and 10-20 cm) and 0.40 % (20-30 cm), while equant pores (EQ) had values of 0.01 % at the three depths under analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An x-ray photoelectron spectroscopy (XPS) analysis of Nb/Al wedge bilayers, oxidized by both plasma and natural oxidation, is reported. The main goal is to show that the oxidation state¿i.e., O:(oxidize)Al ratio¿, structure and thickness of the surface oxide layer, as well as the thickness of the metallic Al leftover, as functions of the oxidation procedure, can be quantitatively evaluated from the XPS spectra. This is relevant to the detailed characterization of the insulating barriers in (magnetic) tunnel junctions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the result of polar angle resolved x¿ray photoemission spectroscopy on Al(111)/O and cluster calculations of the O(1s) binding energy (BE) for various model situations. In the experimental data two O(1s) peaks are observed, separated by 1.3 eV. The angular behavior (depth¿resolution) could indicate that the lower BE peak is associated with an O atom under the surface, and the higher BE peak with an O atom above the surface. Equally, it could indicate oxygen islands on the surface where the perimeter atoms have a higher O(1s) BE than the interior atoms. The cluster calculations show that the former interpretation cannot be correct, since an O ads below the surface has a higher calculated O(1s) BE than one above. Cluster calculations simulating oxygen islands are, however, consistent with the experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The O 1s x-ray photoelectron spectroscopy spectrum for Al(111)/O at 300 K shows two components whose behavior as a function of time and variation of detection angle are consistent with either (a) a surface species represented by the higher binding-energy (BE) component and a subsurface species represented by the lower BE component, or (b) small close-packed oxygen islands with the interior atoms represented by the lower BE component and the perimeter atoms by the higher BE component. We have modeled both situations using ab initio Hartree-Fock wave functions for clusters of Al and O atoms. For an O atom in a threefold site, it was found that a below-surface position gave a higher O 1s BE than an above-surface position, incompatible with interpretation (a). This change in the O 1s BE could arise because the bond for O to Al may have a more covalent character when the O is below the surface than when it is above the surface. We present evidence consistent with this view. An O adatom island with all the O atoms in threefold sites gives calculated O 1s BE's which are significantly higher for the perimeter O atoms. Further, the results for an isolated O island without the Al substrate present also give higher BE¿s for the perimeter atoms. Both these results are consistent with interpretation (b). Published scanning-tunneling-microscopy data supports the suggestion that the chemisorbed state consists of small, close-packed islands, whereas the presence of two vibrational modes in high-resolution electron-energy-loss spectroscopy data has been interpreted as representing surface and subsurface oxygen atoms. In light of the present results, we suggest that a vibrational interpretation in terms of interior and perimeter adatoms should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermal analysis, powder diffraction, and Raman scattering as a function of the temperature were carried out on K2BeF4. Moreover, the crystal structure was determined at 293 K from powder diffraction. The compound shows a transition from Pna21 to Pnam space group at 921 K with a transition enthalpy of 5 kJ/mol. The transition is assumed to be first order because the compound shows metastability. Structurally and spectroscopically the transition is similar to those observed in (NH4)2SO4, which suggests that the low-temperature phase is ferroelectric. In order to confirm it, the spontaneous polarization has been computed using an ionic model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Any transportation infrastructure system is inherently concerned with durability and performance issues. The proportioning and uniformity control of concrete mixtures are critical factors that directly affect the longevity and performance of the portland cement concrete pavement systems. At present, the only means available to monitor mix proportions of any given batch are to track batch tickets created at the batch plant. However, this does not take into account potential errors in loading materials into storage silos, calibration errors, and addition of water after dispatch. Therefore, there is a need for a rapid, cost-effective, and reliable field test that estimates the proportions of as-delivered concrete mixtures. In addition, performance based specifications will be more easily implemented if there is a way to readily demonstrate whether any given batch is similar to the proportions already accepted based on laboratory performance testing. The goal of the present research project is to investigate the potential use of a portable x-ray fluorescence (XRF) technique to assess the proportions of concrete mixtures as they are delivered. Tests were conducted on the raw materials, paste and mortar samples using a portable XRF device. There is a reasonable correlation between the actual and calculated mix proportions of the paste samples, but data on mortar samples was less reliable.