948 resultados para Medical devices-related pressure ulcer


Relevância:

50.00% 50.00%

Publicador:

Resumo:

OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work we studied the mixture of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS), a commercial polymer, with monobasic potassium phosphate (KDP), a piezoelectric salt, as a possible novel material in the fabrication of a low cost, easy-to-make,flexible pressure sensing device. The mixture between KDP and PEDOT: PSS was painted in a flexible polyester substrate and dried. Afterwards, I x V curves were carried out. The samples containing KDP presented higher values of current in smaller voltages than the PEDOT: PSS without KDP. This can mean a change in the chain arrays. Other results showed that the material responds to directly applied pressure to the sample that can be useful to sensors fabrication. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the isolated and associated effects of estrogen therapy (estradiol valerate 1 mg/d orally) and physical exercise (moderate aerobic exercise, 3 h/wk) on health-related quality of life (HRQOL) and menopausal symptoms among women who had undergone hysterectomy. Design: A 6-month, randomized, double-blind, placebo-controlled clinical trial with 44 postmenopausal women who had undergone hysterectomy. The interventions were physical exercise and hormone therapy (n = 9), being sedentary and hormone therapy (n = 14), physical exercise and placebo (n = 11), and being sedentary and placebo (n = 10). HRQOL was assessed by a Brazilian standard version of the Medical Outcome Study Short-Forrn Health Survey and symptoms by Kupperman Index at baseline and after 6 months. Results: There was a decrease in symptoms in all groups, but only groups who performed physical exercise showed an increase in quality of life. Analysis of variance showed that changes in physical functioning (P = 0.001) and bodily pain (P = 0.012) scores over the 6-month period differed significantly between women who exercised and women who were sedentary, regardless of hormone therapy. Hormone therapy had no effect, and there was also no significant association between physical exercise and hormone therapy in HRQOL. Conclusions: Physical exercises can reduce menopausal symptoms and enhance HRQOL, independent of whether hormone therapy is taken.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A survey was done to determine the most common hospital accidents with biologically contaminated material among students at the Medical College of the Federal University of Minas Gerais. Six hundred and ninety-four students (between fifth and twelfth semesters of the college course) answered the questionnaire individually. Three-hundred and forty-nine accidents were reported. The accident rate was found to be 33.9% in the third semester of the course, and increased over time, reaching 52.3% in the last semester. Sixty-three percent of the accidents were needlestick or sharp object injuries; 18.3% mucous membrane exposure; 16.6% were on the skin, and 1.7% were simultaneously on the skin and mucous membrane exposure. The contaminating substances were: blood (88.3%), vaginal secretion (1.7%), and others (9.1%). The parts of the body most frequently affected were: hands (67%), eyes (18.9%), mouth (1.7%), and others (6.3%). The procedures being performed when the accidents occurred were: suture (34.1%), applying anesthesia (16.6%), assisting surgery (8.9%), disposing of needles (8.6%), assisting delivery (6.3%), and others (25.9%). Forty-nine percent of those involved reported the accident to the accident control department. Of these 29.2% did not receive adequate medical assistance. Eight percent of those involved used antiretroviral drugs and of these 86% discontinued the treatment on receiving the Elisa method applied to the patient (HIV-negative); 6.4% discontinued the treatment due to its side-effects; and 16% completed the treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The medical records of 27 patients with hantavirus pulmonary syndrome were analyzed according to the need for invasive mechanical ventilation in relation to the following data up on hospital admission: age, gender, fever, cough, dyspnea, systolic arterial blood pressure, heart rate, levels of hemoglobin, hematocrit, leukocytes, lymphocytes, platelets, creatinine and arterial blood gases. The volume infused during the first 24 hours after admission, the use of inotropic agents, the use of corticosteroids and the patient outcomes were also evaluated. A favorable outcome was related to systolic blood pressure³ 100mmHg, heart rate lower than 100 beats per minute, creatinine below 1.6mg/dl, arterial blood pH³ 7.35, bicarbonate higher than 15mEq/dl, oxygen saturation higher than 84.1%, lower rehydration volume in the first 24 hours of hospitalization and no use of inotropic agents. Absence of clinical and laboratory signs of circulatory shock up on admission was associated with a favorable outcome of the patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Buruli Ulcer (BU) is a neglected infectious disease caused by Mycobacterium ulcerans that is responsible for severe necrotizing cutaneous lesions that may be associated with bone involvement. Clinical presentations of BU lesions are classically classified as papules, nodules, plaques and edematous infiltration, ulcer or osteomyelitis. Within these different clinical forms, lesions can be further classified as severe forms based on focality (multiple lesions), lesions' size (>15 cm diameter) or WHO Category (WHO Category 3 lesions). There are studies reporting an association between delay in seeking medical care and the development of ulcerative forms of BU or osteomyelitis, but the effect of time-delay on the emergence of lesions classified as severe has not been addressed. To address both issues, and in a cohort of laboratory-confirmed BU cases, 476 patients from a medical center in Allada, Benin, were studied. In this laboratory-confirmed cohort, we validated previous observations, demonstrating that time-delay is statistically related to the clinical form of BU. Indeed, for non-ulcerated forms (nodule, edema, and plaque) the median time-delay was 32.5 days (IQR 30.0-67.5), while for ulcerated forms it was 60 days (IQR 20.0-120.0) (p = 0.009), and for bone lesions, 365 days (IQR 228.0-548.0). On the other hand, we show here that time-delay is not associated with the more severe phenotypes of BU, such as multi-focal lesions (median 90 days; IQR 56-217.5; p = 0.09), larger lesions (diameter >15 cm) (median 60 days; IQR 30-120; p = 0.92) or category 3 WHO classification (median 60 days; IQR 30-150; p = 0.20), when compared with unifocal (median 60 days; IQR 30-90), small lesions (diameter =15 cm) (median 60 days; IQR 30-90), or WHO category 1+2 lesions (median 60 days; IQR 30-90), respectively. Our results demonstrate that after an initial period of progression towards ulceration or bone involvement, BU lesions become stable regarding size and focal/multi-focal progression. Therefore, in future studies on BU epidemiology, severe clinical forms should be systematically considered as distinct phenotypes of the same disease and thus subjected to specific risk factor investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PhD in Sciences Specialty in Physics

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: This study aims to assess whether patent foramen ovale (PFO) closure is superior to medical therapy in preventing recurrence of cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We searched PubMed for randomized trials which compared PFO closure with medical therapy in cryptogenic stroke/TIA using the items: "stroke or cerebrovascular accident or TIA" and "patent foramen ovale or paradoxical embolism" and "trial or study". RESULTS: Among 650 potentially eligible articles, 3 were included including 2303 patients. There was no statistically significant difference between PFO-closure and medical therapy in ischemic stroke recurrence (1.91% vs. 2.94% respectively, OR: 0.64, 95%CI: 0.37-1.10), TIA (2.08% vs. 2.42% respectively, OR: 0.87, 95%CI: 0.50-1.51) and death (0.60% vs. 0.86% respectively, OR: 0.71, 95%CI: 0.28-1.82). In subgroup analysis, there was significant reduction of ischemic strokes in the AMPLATZER PFO Occluder arm vs. medical therapy (1.4% vs. 3.04% respectively, OR: 0.46, 95%CI: 0.21-0.98, relative-risk-reduction: 53.2%, absolute-risk-reduction: 1.6%, number-needed-to-treat: 61.8) but not in the STARFlex device (2.7% vs. 2.8% with medical therapy, OR: 0.93, 95%CI: 0.45-2.11). Compared to medical therapy, the number of patients with new-onset atrial fibrillation (AF) was similar in the AMPLATZER PFO Occluder arm (0.72% vs. 1.28% respectively, OR: 1.81, 95%CI: 0.60-5.42) but higher in the STARFlex device (0.64% vs. 5.14% respectively, OR: 8.30, 95%CI: 2.47-27.84). CONCLUSIONS: This meta-analysis does not support PFO closure for secondary prevention with unselected devices in cryptogenic stroke/TIA. In subgroup analysis, selected closure devices may be superior to medical therapy without increasing the risk of new-onset AF, however. This observation should be confirmed in further trials using inclusion criteria for patients with high likelihood of PFO-related stroke recurrence.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Minister for Health and Children has requested that an independent review be carried out of the circumstances surrounding the employment of a UK based Consultant Psychiatrist, Dr John Harding-Price, to a locum psychiatrist position with the South Eastern Health Board (SEHB) while he was suspended by the General Medical Council (GMC) in the United Kingdom and consequently the subject of legal proceedings by the Medical Council in Ireland. The Consultant was continuously registered with the Medical Council since 1968. Download the document here

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Acute subdural haematoma (ASDH) is one of the conditions most strongly associated with severe brain injury. Reports prior to 1980 describe overall mortality rates for acute subdural haematomas (SDH's) ranging from 40% to 90% with poor outcomes observed in all age groups. Recently, improved results have been reported with rapid diagnosis and surgical treatment. The elderly are predisposed to bleeding due to normal cerebral atrophy related to aging, stretching the bridging veins from the dura. Prognosis in ASDH is associated with age, time from injury to treatment, presence of pupillary abnormalities, Glasgow Coma Score (GCS) or motor score on admission, immediate coma or lucid interval, computerized tomography findings (haematoma volume, degree of midline shift, associated intradural lesion, compression of basal cisterns), post-operative intracranial pressure and type of surgery. Advancing age is known to be a determinant of outcome in head injury. The authors present the results of a retrospective study carried out in Beaumont Hospital, Dublin, Ireland's national neurosurgical centre. The aim of this study was to examine the impact of age on outcome in patients with ASDH following severe head injury. Only cases with acute subdural haematoma requiring surgical evacuation were recruited.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: Failed back surgery syndrome (FBSS) patients experience pain, functional disability, and reduced health-related quality of life (HRQoL) despite anatomically successful surgery. Examining sub-dimensions of health outcomes measures provides insight into patient well-being. Materials and Methods: The international multicenter PROCESS trial collected detailed HRQoL (EuroQol-5D; Short-Form 36) and function (Oswestry Disability Index) information on 100 FBSS patients. Results: At baseline, patients reported moderate-to-severe leg and back pain adversely affecting all dimensions of function and HRQoL. Compared with conventional medical management alone, patients also receiving spinal cord stimulation (SCS) reported superior pain relief, function, and HRQoL at six months on overall and most sub-component scores. The majority of these improvements with SCS were sustained at 24 months. Nonetheless, 36-40% of patients experienced ongoing marked disability (standing, lifting) and HRQoL problems (pain/discomfort). Conclusions: Longer-term patient management and research must focus on these refractory FBSS patients with persisting poor function and HRQoL outcomes.