923 resultados para Maxillofacial prosthesis implantation


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computational modelling is becoming ever more important for obtaining regulatory approval for new medical devices. An accepted approach is to infer performance in a population from an analysis conducted for an idealised or ‘average’ patient; we present here a method for predicting the performance of an orthopaedic implant when released into a population—effectively simulating a clinical trial. Specifically we hypothesise that an analysis based on a method for predicting the performance in a population will lead to different conclusions than an analysis based on an idealised or ‘average’ patient. To test this hypothesis we use a finite element model of an intramedullary implant in a bone whose size and remodelling activity is different for each individual in the population. We compare the performance of a low Young’s modulus implant (View the MathML source) to one with a higher Young’s modulus (200 GPa). Cyclic loading is applied and failure is assumed when the migration of the implant relative to the bone exceeds a threshold magnitude. The analysis for an idealised of ‘average’ patient predicts that the lower modulus device survives longer whereas the analysis simulating a clinical trial predicts no statistically-significant tendency (p=0.77) for the low modulus device to perform better. It is concluded that population-based simulations of implant performance–simulating a clinical trial–present a very valuable opportunity for more realistic computational pre-clinical testing of medical devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To evaluate the outcome of Baerveldt implantation with adjunctive mitomycin-C in cases of complicated glaucoma. PATIENTS AND METHODS: The authors reviewed the charts of all patients who had undergone Baerveldt implantation with mitomycin-C between January 1993 and March 1995. Success was defined before data collection as an intraocular pressure (IOP) between 5 and 21 mm Hg, with or without medications. The success rate was calculated using the Kaplan-Meier actuarial method. RESULTS: Twenty-nine patients were identified. The mean preoperative IOP was 33.6 mm Hg, with an average of 2.0 antiglaucoma medications. The probability of success at 6 and 12 months for patients who received mitomycin-C during Baerveldt implantation was 82.4% and 73.3%, respectively. Choroidal effusion with a flat anterior chamber (10.3%), corneal edema (6.8%), and conjunctival erosion (6.8%) were the most frequent complications. CONCLUSION: In this retrospective series of complicated glaucoma, the implantation of a Baerveldt drainage device with adjunctive mitomycin-C had a satisfactory outcome. The complications encountered and the clinical efficacy were comparable to those of previously reported series in which mitomycin-C was not used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the outcome of combined mitomycin-C filtering surgery, phacoemulsification, and foldable intraocular lens (IOL) implantation. Setting: Wills Eye Hospital, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. Methods: This retrospective study evaluated 182 eyes of 174 patients who had combined mitomycin-C trabeculectomy, phacoemulsification, and insertion of a foldable IOL through a 3.5 mm incision. Success of the combined procedure was defined as intraocular pressure (IOP) below 21 mm Hg, with or without medications, and no serious complication. Success rates were calculated using the Kaplan-Meier actuarial method. Results: Mean follow-up was 16.7 months ± 5.4 (SD). The probability of success at 6, 12, 18, and 24 months was 98.3, 95.6, 90.6, and 88.0%, respectively. When compared with preoperativety, visual acuity improved one or more lines in 148 eyes (81.3%) and worsened one or more lines in 15 (8.2%); 111 eyes (61.0%) achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsule opacification requiring capsulotomy, which occurred in 22 cases (12.0%). Conclusion: The 1 year and 2 year IOP control rate of combined mitomycin-C filtering procedures and phacoemulsification in glaucoma patients was high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the efficacy and safety of intraoperative mitomycin C (MMC) in eyes undergoing Ahmed Glaucoma Valve implantation. Design Randomized controlled clinical trial. Participants Sixty patients with refractory glaucoma. Intervention Sixty eyes of 60 patients with refractory glaucoma were randomized to receive intraoperative MMC (0.5 mg/ml for 5 minutes) (n = 34) or balanced salt solution (n = 26) during Ahmed Glaucoma Valve implantation. Main outcome measures Surgical success was defined according to 2 different criteria: (1) postoperative intraocular pressure (IOP) between 6 and 21 mmHg, with or without antiglaucoma medications, and (2) IOP reduction of at least 30% relative to preoperative values. Eyes requiring additional glaucoma surgery, developing phthisis, or showing loss of light perception were classified as failures. Success rates in both groups were compared using Kaplan-Meier survival curves and the log rank test. Other outcome measures were mean IOP, number of glaucoma medications, and complications. Results After a mean follow-up of 12.3 months, Kaplan-Meier survival analysis showed a probability of success of 59% at 18 months for the MMC group and 61% for the control group when the first criterion for success was used (IOP between 6 and 21 mmHg). When an IOP reduction of at least 30% was used as the criterion to define success, the Kaplan-Meier survival analysis demonstrated a probability of success at 18 months of 62% for the MMC group and 67% for the control group. There were no significant differences in survival rates between the 2 groups with either criterion (P = 0.75 and P = 0.37, respectively). After 15 days postoperatively, the mean IOP did not significantly differ for both MMC and control eyes. Mean numbers of postoperative antiglaucoma medications were similar in MMC-treated eyes and controls. There was no significant difference between the incidences of postoperative complications in both groups. Conclusion Mitomycin C did not increase the short- or intermediate-term success rates of Ahmed Glaucoma Valve implantation. © 2004 by the American Academy of Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care.

METHODS/DESIGN: EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate.

TRIAL REGISTRATION: ISRCTN44464607.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report describes the implantation of a standard posterior chamber intraocular lens (IOL) in a patient with bilateral cataract and anterior megalophthalmos. After extracapsular cataract extraction, the IOL was sutured to the posterior surface of the iris and anterior capsule. Different types of IOLs were used in each eye, and the surgical technique was adapted to the characteristics of the IOL. No complications were noted. Visual rehabilitation was successful. Extracapsular cataract extraction with a posterior chamber IOL sutured to the posterior surface of the iris and anterior capsule is a useful option in patients with anterior megalophthalmos and cataract.