952 resultados para Lente intraocular multifocal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To report acute/subacute vision loss and paracentral scotomata in patients with idiopathic multifocal choroiditis/punctate inner choroidopathy due to large zones of acute photoreceptor attenuation surrounding the chorioretinal lesions. METHODS Multimodal imaging case series. RESULTS Six women and 2 men were included (mean age, 31.5 ± 5.8 years). Vision ranged from 20/20-1 to hand motion (mean, 20/364). Spectral domain optical coherence tomography demonstrated extensive attenuation of the external limiting membrane, ellipsoid and interdigitation zones, adjacent to the visible multifocal choroiditis/punctate inner choroidopathy lesions. The corresponding areas were hyperautofluorescent on fundus autofluorescence and were associated with corresponding visual field defects. Full-field electroretinogram (available in three cases) showed markedly decreased cone/rod response, and multifocal electroretinogram revealed reduced amplitudes and increased implicit times in two cases. Three patients received no treatment, the remaining were treated with oral corticosteroids (n = 4), oral acyclovir/valacyclovir (n = 2), intravitreal/posterior subtenon triamcinolone acetate (n = 3), and anti-vascular endothelial growth factor (n = 2). Visual recovery occurred in only three cases of whom two were treated. Varying morphological recovery was found in six cases, associated with decrease in hyperautofluorescence on fundus autofluorescence. CONCLUSION Multifocal choroiditis/punctate inner choroidopathy can present with transient or permanent central photoreceptor attenuation/loss. This presentation is likely a variant of multifocal choroiditis/punctate inner choroidopathy with chorioretinal atrophy. Associated changes are best evaluated using multimodal imaging.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transforming growth factor beta 1 (TGF beta 1)-null mice die fro complications due to an early-onset multifocal inflammatory disorder. We show here that cardiac cells are hyperproliferative and that intercellular adhesion molecule 1 (ICAM-1) is elevated. To determine which phenotypes are primarily caused by a deficiency in TGF beta 1 from those that are secondary to inflammation, we applied immunosuppressive therapy and genetic combination with the severe combined immunodeficiency (SCID) mutation to inhibit the inflammatory response. Treatment with antibodies to the leukocyte function-associated antigen 1 doubled longevity, reduced inflammation, and delayed heart cell proliferation. TGF beta 1-null SCID mice displayed no inflammation or cardiac cell proliferation, survived to adulthood, and exhibited normal major histocompatibility complex II (MHC II) and ICAM-1 levels. TGF beta 1-null pups born to a TGF beta 1-null SCID mother presented no gross congenital heart defects, indicating that TGF beta 1 alone does not play an essential role in heart development. These results indicate that lymphocytes are essential for the inflammatory response, cardiac cell proliferation, and elevated MHC II and ICAM-1 expression, revealing a vital role for TGF beta 1 in regulating lymphocyte proliferation and activation, which contribute to the maintenance of self tolerance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate visual results with two multifocal diffractive lenses designed with the same platform but with different additions. SETTING: Grupo Innova Ocular clinics. METHODS: A total of 50 eyes from 50 patients were included. Group 1 (n = 25) was implanted with the TECNIS® 1 ZLB +3.25 and group 2 (n = 25) with the TECNIS® 1 ZKB +2.75. Patients were assessed at 24 hours, 1 week and 1 month postoperatively. At surgical discharge, corrected (CDVA) and uncorrected distance visual acuity (UCDVA), near visual acuity (VA) at 25, 40 and 80 cm, visual quality and the defocus curve were measured. RESULTS: Changes in sphere and spherical equivalent were statistically significant (p<0.01) in both groups at 1 week and 1 month compared to preoperative values. In group 1, UCDVA logMAR at 1 month was 0.06 ± 0.02. In group 2, UCDVA at 1 month was 0.03 ± 0.03. In near vision, the TECNIS® 1 ZLB group obtained a VA logMAR of 0.35 ± 0.02 at 25 cm, 0.13 ± 0.02 at 40 cm and 0.27 ± 0.02 at 80 cm, while in the TECNIS® 1 ZKB group, the values were 0.38  ± 0.03, 0.14 ± 0.03 and 0.23 ± 0.06, respectively. No statistically significant differences were found either when results for visual quality were compared. CONCLUSION: Both the TECNIS® 1 ZLB and TECNIS® 1 ZKB are excellent options for obtaining good distance and near vision, in addition to providing good intermediate vision, especially at distances such as those required for working with computers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape. METHODS: Twenty-one patients (42 eyes) with cataract and less than 1.50 D of corneal astigmatism underwent implantation of one FineVision/MicoF IOL in one eye and one POD FineVision IOL in the contralateral eye (PhysIOL, Liège, Belgium) at IOA Madrid Innova Ocular, Madrid, Spain. IOL allocation was random. Outcome measures, all evaluated 3 months postoperatively, included monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), distance-corrected intermediate (DCIVA), and near (DCNVA) visual acuity (at 80, 40, and 25 cm) under photopic conditions, refraction, IOL centration, haptic rotation, dysphotopsia, objective quality of vision and aberration quantification, patient satisfaction, and spectacle independence. RESULTS: Three months postoperatively, mean monocular UDVA, CDVA, DCIVA, and DCNVA (40 cm) under photopic conditions were 0.04 ± 0.07, 0.01 ± 0.04, 0.15 ± 0.11, and 0.16 ± 0.08 logMAR for the eyes implanted with the POD FineVision IOL and 0.03 ± 0.05, 0.01 ± 0.02, 0.17 ± 0.12, and 0.14 ± 0.08 logMAR for those receiving the FineVision/MicroF IOL. Moreover, the POD FineVision IOL showed similar centration (P > .05) and better rotational stability (P < .05) than the FineVision/MicroF IOL. Regarding halos, there was a minimal but statistically significant difference, obtaining better results with FineVision/MicroF. Full spectacle independence was reported by all patients. CONCLUSIONS: This study revealed similar visual outcomes for both trifocal IOLs under test (POD FineVision and FineVision/MicroF). However, the POD FineVision IOL showed better rotational stability, as afforded by its design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se presenta un caso clínico con solución de lente de contacto cosmética para una paciente con midriasis máxima irrefléxica provocada por una complicación en cirugía de cataratas. El caso se complica al tener la paciente, además, una endo e hipertropía en ojo izquierdo (OI). Se realiza un estudio optométrico y contactológico en profundidad para establecer la idoneidad del tratamiento elegido y la solución propuesta y aceptada, que es la de adaptar una LC de material biocompatible y trabajada artesanalmente. Con ella se consigue un resultado muy natural y nos aseguramos que el material respeta por completo la fisiología del ojo. Después de una serie de pruebas adaptativas se consigue dotar a la paciente de la comodidad y similitud facial inicialmente consideradas en la primera visita, quedando así subsanada estéticamente esta atrofia ocular inicial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente, la adaptación de lentes de contacto nos ofrece una buena solución óptica para anisometropías, ya que se consigue igualar el tamaño de las imágenes retinianas, astigmatismos irregulares, consiguiendo regularizar la superficie corneal anterior, en miopías medias y elevadas, porque se logra un mayor tamaño de imagen retiniana respecto a la lente oftálmica, en casos de hipermetropías altas o afaquias, al conseguir un aumento del campo visual, y en nistagmus, ya que la lente acompaña al movimiento del ojo. A continuación, presentamos un caso de rehabilitación visual completa con la adaptación de una lente de contacto híbrida de geometría inversa en una córnea operada de cirugía LASIK miópica fallida, que tuvo como consecuencia una inducción muy significativa de irregularidad corneal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La lente híbrida de geometría inversa PS ofrece una mejoría de la calidad visual en pacientes con córneas irregulares tras cirugía refractiva miópica, mostrándose como una excelente opción en aquellos casos en que el insuficiente lecho corneal imposibilita retratamientos posteriores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diurnal changes in corneal geometry, pachymetry, and intraocular pressure (IOP) in a healthy eye were recorded. The deformation response to an air puff was simulated using 3 levels of corneal stiffness. The response was dependent on IOP and pachymetry and not only on the biomechanical properties of the cornea. Similarly, the maximum variability due to the diurnal changes in pachymetry and IOP in the corneal displacement generated by the air puff was found to reach 5%. Therefore, diurnal changes in IOP and corneal thickness were able to induce some variability in the air puff–based corneal deformation response. This potential variability should be considered when the biomechanical properties of the cornea are analyzed with air-puff devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The aim was to evaluate the visual performance achieved with a new multifocal hybrid contact lens and to compare it with that obtained with two other currently available multifocal soft contact lenses. Methods: This pilot prospective comparative study comprised a total of 16 presbyopic eyes of eight patients ranging in age from 43 to 58 years. All patients were fitted with three different models of multifocal contact lens: Duette multifocal (SynergEyes), Air Optix AQUA multifocal (Alcon) and Biofinity multifocal (CooperVision). Fittings were performed randomly in each patient according to a random number sequence, with a wash-out period between fittings of seven days. At two weeks post-fitting, visual, photopic contrast sensitivity and ocular aberrometry were evaluated. Results: No statistically significant differences were found in distance and near visual acuity achieved with the three different types of multifocal contact lens (p ≥ 0.05). Likewise, no significant differences between lenses were found in the monocular and binocular defocus curve (p ≥ 0.10). Concerning contrast sensitivity, better monocular contrast sensitivities for 6, 12 and 18 cycles per degree were found with the Duette and Air Optix multifocal compared to Biofinity (p = 0.02). Binocularly, differences between lenses were not significant (p ≥ 0.27). Furthermore, trefoil aberration was significantly higher with Biofinity multifocal (p < 0.01) and Air Optix (p = 0.01) multifocal compared to Duette. Conclusions: The Duette multifocal hybrid contact lens seems to provide similar visual quality outcomes in presbyopic patients with low corneal astigmatism, when compared with other soft multifocal contact lenses. This preliminary result should be confirmed in studies with larger samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). Setting: Premium Clinic, Teplice, Czech Republic. Design: Prospective case series. Methods: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. Results: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of −1.0 diopter (D) and −2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. Conclusion: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality.