990 resultados para torque correlation factor
Resumo:
OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º) presented statistically significant difference from the proposed values (-7º). For the mandibular canines, American Orthodontics (-6.34º) and Ortho Organizers (-6.25º) presented statistically significant differences from the standards (-6º). Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.
Correlation between margin fit and microleakage in complete crowns cemented with three luting agents
Resumo:
Microleakage can be related to margin misfit. Also, traditional microleakage techniques are time-consuming. This study evaluated the existence of correlation between in vitro margin fit and a new microleakage technique for complete crowns cemented with 3 different luting agents. Thirty human premolars were prepared for full-coverage crowns with a convergence angle of 6 degrees, chamfer margin of 1.2 mm circumferentially, and occlusal reduction of 1.5 mm. Ni-Cr cast crowns were cemented with either zinc phosphate (ZP) (S.S. White), resin-modified glass-ionomer (RMGI) (Rely X Luting Cement) or a resin-based luting agent (RC) (Enforce). Margin fit (seating discrepancy and margin gap) was evaluated according to criteria in the literature under microscope with 0.001 mm accuracy. After thermal cycling, crowns were longitudinally sectioned and microleakage scores at tooth-cement interface were obtained and recorded at ×100 magnification. Margin fit parameters were compared with the one-way ANOVA test and microleakage scores with Kruskal-Wallis and Dunn's tests (alpha=0.05). Correlation between margin fit and microleakage was analyzed with the Spearman's test (alpha=0.05). Seating discrepancy and marginal gap values ranged from 81.82 µm to 137.22 µm (p=0.117), and from 75.42 µm to 78.49 µm (p=0.940), respectively. Marginal microleakage scores were ZP=3.02, RMGI=0.35 and RC=0.12 (p<0.001), with no differences between RMGI and RC scores. The correlation coefficient values ranged from -0.27 to 0.30 (p>0.05). Conclusion: Margin fit parameters and microleakage showed no strong correlations; cast crowns cemented with RMGI and RC had lower microleakage scores than ZP cement.
Resumo:
The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 oC-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs.
Resumo:
This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.
Resumo:
OBJECTIVES: The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350) and adhesive system [(Solobond Plus, Futurabond NR (VOCO) and Adper Single Bond (3M ESPE)] on the microtensile (μTBS) and microshear bond strength (μSBS) tests on enamel, and to correlate the bond strength means between them. MATERIAL AND METHODS: Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for μTBS and the other one for μSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37(0)C/24 h) specimens were stressed (0.5 mm/min). Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05). RESULTS: The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05). For both tests only the main factor resin composite was statistically significant (p<0.05). The correlation test detected a positive (r=0.91) and significant (p=0.01) correlation between the tests. CONCLUSIONS: The results were more influenced by the resin type than by the adhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions.
Resumo:
The aim of this study was to verify whether screw abutment lubrication can generate higher preload values compared to non-lubricated screws, a titanium abutment was screwed onto an implant analog and scanned with the Procera System to generate 20 zirconia abutments. MKIII Brånemark implants were clamped to a precision torque device, and the abutments were distributed in dry and wet groups with 10 specimens each. In the wet groups, the inner threads of the implants were filled with artificial saliva. All abutments were fastened with a Torqtite screw under 32 Ncm. Ten detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean detorque values were calculated and compared by a Student's t test (?=0.05). The wet condition presented significantly higher mean detorque than the dry condition (31.5 ± 1.2 versus 27.5 ± 1.5 Ncm, respectively; p=0.0000024). In conclusion, there was always a loss in the initial torque values when the removal torque was measured under both conditions. The wet condition presented higher mean torque than the dry condition. Better preload values were established in the wet group, suggesting that the abutment screw must be lubricated in saliva to avoid further loosening.
Resumo:
A modified version of the intruder-resident paradigm was used to investigate if social recognition memory lasts at least 24 h. One hundred and forty-six adult male Wistar rats were used. Independent groups of rats were exposed to an intruder for 0.083, 0.5, 2, 24, or 168 h and tested 24 h after the first encounter with the familiar or a different conspecific. Factor analysis was employed to identify associations between behaviors and treatments. Resident rats exhibited a 24-h social recognition memory, as indicated by a 3- to 5-fold decrease in social behaviors in the second encounter with the same conspecific compared to those observed for a different conspecific, when the duration of the first encounter was 2 h or longer. It was possible to distinguish between two different categories of social behaviors and their expression depended on the duration of the first encounter. Sniffing the anogenital area (49.9% of the social behaviors), sniffing the body (17.9%), sniffing the head (3%), and following the conspecific (3.1%), exhibited mostly by resident rats, characterized social investigation and revealed long-term social recognition memory. However, dominance (23.8%) and mild aggression (2.3%), exhibited by both resident and intruders, characterized social agonistic behaviors and were not affected by memory. Differently, sniffing the environment (76.8% of the non-social behaviors) and rearing (14.3%), both exhibited mostly by adult intruder rats, characterized non-social behaviors. Together, these results show that social recognition memory in rats may last at least 24 h after a 2-h or longer exposure to the conspecific.
Resumo:
The parasitic protozoan Leishmania (Leishmania) amazonensis alternates between mammalian and insect hosts. In the insect host, the parasites proliferate as procyclic promastigotes andthen differentiate into metacyclic infective forms. The meta 1 gene is preferentially expressed during metacyclogenesis. Meta 1 expression profile determination along parasite growth curves revealed that the meta 1 mRNA level peaked at the early stationary phase then decreased to an intermediate level. No correlation was observed between meta 1 expression and infectivity. Conversely, infectivity correlated with the increase of apoptotic cells in the late stationary phase.
Resumo:
BACKGROUND: Rett syndrome (RS) is a severe neurodevelopmental X-linked dominant disorder caused by mutations in the MECP2 gene. PURPOSE: To search for point mutations on the MECP2 gene and to establish a correlation between the main point mutations found and the phenotype. METHOD: Clinical evaluation of 105 patients, following a standard protocol. Detection of point mutations on the MECP2 gene was performed on peripheral blood DNA by sequencing the coding region of the gene. RESULTS: Classical RS was seen in 68% of the patients. Pathogenic point mutations were found in 64.1% of all patients and in 70.42% of those with the classical phenotype. Four new sequence variations were found, and their nature suggests patogenicity. Genotype-phenotype correlations were performed. CONCLUSION: Detailed clinical descriptions and identification of the underlying genetic alterations of this Brazilian RS population add to our knowledge of genotype/phenotype correlations, guiding the implementation of mutation searching programs.
Resumo:
The aim of this study was to verify the influence of an experimental heat treatment (170ºC/10 min) using a casting furnace on the mechanical properties (hardness and flexural strength) of 2 commercial direct resin composites (TPH Spectrum and Filtek P60) compared to a commercial indirect resin system (BelleGlass). Heat treatment temperature was determined after thermal characterization by thermogravimetry (TG) and differential scanning calorimetry (DSC). Data was analyzed by ANOVA and Tukey's test at 5% significance level. There was statistical significance for the main factor heat treatment (p=0.03) and composite (p=0.02), for flexural strength. For Knoop hardness, only the main factor composite was statistically significant (p=0.00). P60 presented higher hardness than TPH. No statistically significant correlation between mechanical properties tested was detected. Based on these results, it was possible to conclude that heat treatment influenced flexural strength of direct composites, while it was not observed for hardness. The association of direct composites with a simple post-cure heat treatment may be an alternative for current indirect composite systems, although more studies are needed to verify other properties of the composites for this application.
Resumo:
Estuarine hydrodynamics is a key factor in the definition of the filtering capacity of an estuary and results from the interaction of the processes that control the inlet morphodynamics and those that are acting in the mixing of the water in the estuary. The hydrodynamics and suspended sediment transport in the Camboriú estuary were assessed by two field campaigns conducted in 1998 that covered both neap and spring tide conditions. The period measured represents the estuarine hydrodynamics and sediment transport prior to the construction of the jetty in 2003 and provides important background information for the Camboriú estuary. Each field campaign covered two complete tidal cycles with hourly measurements of currents, salinity, suspended sediment concentration and water level. Results show that the Camboriú estuary is partially mixed with the vertical structure varying as a function of the tidal range and tidal phase. The dynamic estuarine structure can be balanced between the stabilizing effects generated by the vertical density gradient, which produces buoyancy and stratification flows, and the turbulent effects generated by the vertical velocity gradient that generates vertical mixing. The main sediment source for the water column are the bottom sediments, periodically resuspended by the tidal currents. The advective salt and suspended sediment transport was different between neap and spring tides, being more complex at spring tide. The river discharge term was important under both tidal conditions. The tidal correlation term was also important, being dominant in the suspended sediment transport during the spring tide. The gravitational circulation and Stokes drift played a secondary role in the estuarine transport processes.
Resumo:
The present contribution explores the impact of the QUALIS metric system for academic evaluation implemented by CAPES (Coordination for the Development of Personnel in Higher Education) upon Brazilian Zoological research. The QUALIS system is based on the grouping and ranking of scientific journals according to their Impact Factor (IF). We examined two main points implied by this system, namely: 1) its reliability as a guideline for authors; 2) if Zoology possesses the same publication profile as Botany and Oceanography, three fields of knowledge grouped by CAPES under the subarea "BOZ" for purposes of evaluation. Additionally, we tested CAPES' recent suggestion that the area of Ecology would represent a fourth field of research compatible with the former three. Our results indicate that this system of classification is inappropriate as a guideline for publication improvement, with approximately one third of the journals changing their strata between years. We also demonstrate that the citation profile of Zoology is distinct from those of Botany and Oceanography. Finally, we show that Ecology shows an IF that is significantly different from those of Botany, Oceanography, and Zoology, and that grouping these fields together would be particularly detrimental to Zoology. We conclude that the use of only one parameter of analysis for the stratification of journals, i.e., the Impact Factor calculated for a comparatively small number of journals, fails to evaluate with accuracy the pattern of publication present in Zoology, Botany, and Oceanography. While such simplified procedure might appeals to our sense of objectivity, it dismisses any real attempt to evaluate with clarity the merit embedded in at least three very distinct aspects of scientific practice, namely: productivity, quality, and specificity.
Resumo:
OBJETIVO: Validar uma escala de auto-eficácia para adesão ao tratamento anti-retroviral em crianças e adolescentes com HIV/AIDS, levando em consideração a perspectiva dos pais/responsáveis, e avaliar a sua reprodutibilidade. MÉTODOS: O estudo foi realizado no Hospital-Dia do Centro de Referência e Treinamento em DST/AIDS de São Paulo. Foram entrevistados os pais/responsáveis de 54 crianças e adolescentes de 6 meses a 20 anos que passaram em consulta de rotina pelo serviço. Os dados de auto-eficácia foram levantados pela escala de auto-eficácia para seguir prescrição anti-retroviral (AE), que foi calculada de duas maneiras: análise fatorial e fórmula já definida. A consistência interna da escala foi verificada pelo coeficiente ade Cronbach. A validade foi avaliada pela comparação das médias dos escores entre grupos de pacientes aderentes e não aderentes ao tratamento anti-retroviral (teste de Mann-Whitney) e cálculo do coeficiente de correlação de Spearman entre os escores e parâmetros clínicos. A reprodutibilidade foi verificada por meio do teste de Wilcoxon, pelo coeficiente de correlação intraclasse (CCI) e pelo gráfico de Bland-Altman. RESULTADOS: A escala de AE apresentou boa consistência interna (a= 0,87) e boa reprodutibilidade (CCI = 0,69 e CCI = 0,75). Quanto à validade, a escala de AE conseguiu discriminar pacientes aderentes e não aderentes ao tratamento anti-retroviral (p = 0,002) e apresentou correlação significativa com a contagem de CD4 (r = 0,28; p = 0,04). CONCLUSÕES: A escala de AE pode ser utilizada para avaliar a adesão à terapia anti-retroviral em crianças e adolescentes com HIV/AIDS, levando em consideração a perspectiva dos pais/cuidadores.
Resumo:
Objetivou-se identificar fatores de risco para nascimentos pré-termo por meio de estudo caso-controle populacional que envolve nascidos vivos hospitalares de mães residentes em Londrina, Paraná, Brasil. Os casos foram os 328 nascimentos pré-termo e os controles, uma amostra proporcional de 369 nascimentos com 37 semanas ou mais. Realizou-se análise de regressão logística múltipla hierarquizada. Verificou-se associação (p < 0,05) para as variáveis: sócio-econômicas - moradia em favela e baixa idade do chefe familiar; características maternas: IMC < 19 e > 30kg/m², com filho anterior pré-termo, com tratamento para engravidar; características maternas durante a gestação: com companheiro há no máximo dois anos, preocupações, bebida alcoólica semanal, pré-natal inadequado, prática de caminhada como proteção; agravos na gestação - sangramento, infecção do trato genital, volume alterado do líquido amniótico, hipertensão arterial e internação; gestação múltipla. A identificação de fatores de risco e a melhoria da qualidade da atenção pré-concepcional e pré-natal podem reduzir a prematuridade.
Resumo:
OBJETIVO:Validar escala de insatisfação corporal para adolescentes. MÉTODOS: Participaram do estudo 386 adolescentes, de ambos os sexos, entre dez e 17 anos de idade, de uma escola particular de ensino fundamental e médio, de São Bernardo do Campo, SP, em 2006. Foram realizadas tradução e adaptação cultural da "Escala de Evaluación de Insatisfación Corporal para Adolescentes" para o português. Foram avaliadas consistência interna por meio do coeficiente alfa de Cronbach, análise fatorial pelo método Varimax e validade discriminante pelas diferenças entre médias de estado nutricional, utilizando-se o teste de Kruskal-Wallis. Na validação concorrente, calculou-se o coeficiente de correlação de Spearman entre a escala e o índice de massa corporal, a razão circunferência quadril e a circunferência da cintura. Para reprodutibilidade, foram utilizados o teste de Wilcoxon, o coeficiente de correlação intra-classe. RESULTADOS: A escala traduzida não apresentou discordâncias significativas com a original. A escala apresentou consistência interna satisfatória para todos os subgrupos estudados (fases inicial e intermediária de adolescência, ambos os sexos) e foi capaz de discriminar os adolescentes segundo o estado nutricional. Na análise concorrente, as três medidas corporais foram correlacionadas, exceto adolescentes do sexo masculino em fase inicial, e sua reprodutibilidade foi confirmada. CONCLUSÕES: A Escala de Avaliação da Insatisfação Corporal para Adolescentes está traduzida e adaptada para o português e apresentou resultados satisfatórios, sendo recomendada para avaliação do aspecto atitudinal da imagem corporal de adolescentes.