964 resultados para swd: Normalization
Resumo:
In this paper we explore the relative performance of two recently developed wave packet methodologies for reactive scattering, namely the real wave packet Chebyshev domain propagation of Gray and Balint-Kurti [J. Chem. Phys. 108, 950 (1998)] and the Lanczos subspace wave packet approach of Smith [J. Chem. Phys. 116, 2354 (2002); Chem. Phys. Lett. 336, 149 (2001)]. In the former method, a modified Schrodinger equation is employed to propagate the real part of the wave packet via the well-known Chebyshev iteration. While the time-dependent wave packet from the modified Schrodinger equation is different from that obtained using the standard Schrodinger equation, time-to-energy Fourier transformation yields wave functions which differ only trivially by normalization. In the Lanczos subspace approach the linear system of equations defining the action of the Green operator may be solved via either time-dependent or time-independent methods, both of which are extremely efficient due to the simple tridiagonal structure of the Hamiltonian in the Lanczos representation. The two different wave packet methods are applied to three dimensional reactive scattering of H+O-2 (total J=0). State-to-state reaction probabilities, product state distributions, as well as initial-state-resolved cumulative reaction probabilities are examined. (C) 2002 American Institute of Physics.
Resumo:
Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6 mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.
Resumo:
Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6 mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.
Resumo:
The main purpose of performance appraisal in organizations is, or should be, to improve the engagement, learning process and progress of the employees and to align individual with team and organizational performance. However, performance appraisal can also be interpreted as an instrument of normalization, discipline and surveillance. This study thus aims to explore and discuss the complex schema of intrinsic and extrinsic objectives of performance appraisal system of the Portuguese public organizations (SIADAP - Performance Evaluation Integrated System). We have developed an exploratory and qualitative case study to capture appraisers and appraises perceptions. The data were analyzed in light of foucauldian theories. According to the qualitative data, namely the discourses of the appraisers and their subordinates, the SIADAP is seen as an instrument of control and dominance that aims to introduce political rationalities, limiting the career progression of the employees. Though some key points of Foucault’s perspective were identified, foucauldian framework revealed some limitations to capture all the complexity inherent to performance appraisal. This study opens new perspectives about the SIADAP and can be of major importance as far as political reflection about performance appraisal in public organizations is concerned.
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI, although, controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.
Resumo:
The use of iris recognition for human authentication has been spreading in the past years. Daugman has proposed a method for iris recognition, composed by four stages: segmentation, normalization, feature extraction, and matching. In this paper we propose some modifications and extensions to Daugman's method to cope with noisy images. These modifications are proposed after a study of images of CASIA and UBIRIS databases. The major modification is on the computationally demanding segmentation stage, for which we propose a faster and equally accurate template matching approach. The extensions on the algorithm address the important issue of pre-processing that depends on the image database, being mandatory when we have a non infra-red camera, like a typical WebCam. For this scenario, we propose methods for reflection removal and pupil enhancement and isolation. The tests, carried out by our C# application on grayscale CASIA and UBIRIS images show that the template matching segmentation method is more accurate and faster than the previous one, for noisy images. The proposed algorithms are found to be efficient and necessary when we deal with non infra-red images and non uniform illumination.
Resumo:
Esta Dissertação de Mestrado subordina-se ao tema: “Normalização de Ensaios de Carga”, sendo esta uma temática pouco desenvolvida em Portugal e para a qual não existe qualquer legislação. Os ensaios de carga são realizados em Portugal sem que haja uma legislação que normalize a sua realização e por isso cada entidade segue a sua metodologia nomeadamente entidades como o Laboratório Nacional de Engenharia Civil (LNEC) ou a Faculdade de Engenharia da Universidade do Porto (FEUP). Os objectivos principais deste trabalho são o estudo da legislação estrangeira existente para ensaios de carga e o seu confronto com as metodologias seguidas em Portugal, com o intuito de identificar aspectos consensuais e controversos e definir questões que possam ser transpostas para um documento normativo português. Este trabalho inicia-se com uma pesquisa bibliográfica, através da qual vão ser abordados conceitos básicos sobre os ensaios de carga como os seus objectivos, os tipos de ensaios ou o modo de tratamento de resultados e será elaborada uma breve resenha histórica dos ensaios de carga. É estudada a legislação existente noutros países, seleccionando-se os aspectos mais relevantes. São também abordadas as metodologias adoptadas por diversas entidades em Portugal como o LNEC e a FEUP. Por último, numa vertente mais analítica serão seleccionados os aspectos mais relevantes da legislação internacional e será estabelecido o confronto com as metodologias seguidas em Portugal de maneira a identificar aspectos relevantes a constar num documento normativo a elaborar futuramente em Portugal.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde.
Resumo:
Introdução – A reconstrução mamária, no processo pós-cancro da mama, poderá ser levada a cabo através da lipoaspiração cujas consequências poderão ser ultrapassadas através da fisioterapia. Objetivo – Verificar, num estudo de caso, os resultados da drenagem linfática manual (DLM) e das bandas neuromusculares (BNM) na dor, edema, hematoma e pigmentação do abdómen e mamas após lipoaspiração para reconstrução mamária. Metodologia – Uma paciente foi sujeita a 10 sessões de fisioterapia com aplicação de DLM e BNM. Em cada sessão foram avaliados, nas mamas e no abdómen, a dor, o edema, o hematoma e a pigmentação. Resultados – Eliminação da dor, desaparecimento do hematoma abdominal, normalização da pigmentação mamária e diminuição do edema. Conclusão – Neste estudo de caso, a DLM e as BNM melhoram as consequências no pós-cirúrgico de lipoaspiração para reconstrução mamária. ABSTRACT - Introduction – Breast reconstruction, post breast cancer, can be carried out through liposuction which consequences may be overcomed through physiotherapy. Objective – Check, in a study case, the results of manual lymphatic drainage (MLD) and neuromuscular bandages (NMB) in pain, edema, bruising and pigmentation on abdomen and breasts, after liposuction for breast reconstruction. Methodology – A patient underwent 10 sessions of physiotherapy with application of MLD and NMB. In each session were evaluated breast and abdomen pain, edema, bruising and pigmentation. Results – Elimination of pain, disappearance of abdominal hematoma, normalization of breast pigmentation and reduction of edema. Conclusion – In this study case, MLD and NMB improve the consequences of post-surgical liposuction for breast reconstruction.
Resumo:
Jornadas de Contabilidade e Fiscalidade promovidas pelo Instituto Superior de Contabilidade e Administração do Porto, em Abril de 2009
Resumo:
Jornadas de Contabilidade e Fiscalidade promovidas pelo Instituto Superior de Contabilidade e Administração do Porto, em Abril de 2009
Resumo:
Dissertação apresentada ao Instituto Superior de Contabilidade e Administração do Porto para a obtenção do Grau de Mestre em Auditoria Orientada pelo Dr. José da Silva Fernandes
Resumo:
Dissertação para a obtenção do grau de mestre em Contabilidade e Finanças Orientador: Mestre António Costa Reis
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI although controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.