913 resultados para liquid chromatography-tandem MS
Resumo:
Determination of free urinary cortisol is a test of choice in the diagnosis of Cushing's syndrome. In this study, cortisol was quantified using reversed-phase high-performance liquid chromatography (RP-HPLC) in urine samples previously extracted with ether and using triamcinolone acetonide as internal standard (IS). A BDS-Hypersil-C18® column, water-acetonitrile (72:28; v/v), with a flow rate of 1.0 mL/min and detection at 243 nm were used. This method showed to be both effective and efficient, with sensitivity and linearity ranging from 2.50 to 150 μg/L, and can be used in substitution to the radioimmunoassay technique within this concentration range.
Resumo:
Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.
Resumo:
A chromatographic technique for determination of rutin and narcissin in marigold extract and topical formulations was developed and validated. The method shows linearity over the concentration range of 0.2 - 6.0 μg/mL of rutin (r = 0.9986) and 0.8 - 12.0 μg/mL of narcissin (r = 0.9951). The values obtained for precision and accuracy are in agreement with ICH guidelines. Both the formulation excipients and the porcine ear skin samples did not interfere with the flavonoids determination. The recovery of rutin and narcissin in skin samples added with marigold extract was 81.41% and 83.35%, respectively, which demonstrate the applicability of this method to perform skin penetration studies.
Resumo:
An analytical procedure to quantify 3-benzophenone, octylmethoxycinnamate and octylsalicylate was validated and employed to assess these ultraviolet filters in sunscreen formulations and from skin penetration studies. The effect of the vehicle on the skin retention of these filters was investigated. HPLC and extraction procedure were found to be reliable when obtaining data for the sunscreen formulations and for evaluation skin penetration. The results demonstrated that a cream gel generated higher epidermal concentrations of these filters than a lotion or cream-based formulation. Additionally, when comparing the skin retentions of each filter using the same formulation, 3-benzophenone showed the highest skin retention.
Resumo:
The hydroalcoholic extracts prepared from standard leaves of Maytenus ilicifolia and commercial samples of espinheira-santa were evaluated qualitatively (fingerprinting) and quantitatively. In this paper, fingerprinting chromatogram coupled with Principal Component Analysis (PCA) is described for the metabolomic analysis of standard and commercial espinheira-santa samples. The epicatechin standard was used as an external standard for the development and validation of a quantitative method for the analysis in herbal medicines using a photo diode array detector. This method has been applied for quantification of epicatechin in commercialized herbal medicines sold as espinheira-santa in Brazil and in the standard sample of M. ilicifolia.
Resumo:
The bioassay, first order derivative UV spectrophotometry and chromatographic methods for assaying fluconazole capsules were compared. They have shown great advantages over the earlier published methods. Using the first order derivative, the UV spectrophotometry method does not suffer interference of excipients. Validation parameters such as linearity, precision, accuracy, limit of detection and limit of quantitation were determined. All methods were linear and reliable within acceptable limits for antibiotic pharmaceutical preparations being accurate, precise and reproducible. The application of each method as a routine analysis should be investigated considering cost, simplicity, equipment, solvents, speed, and application to large or small workloads.
Resumo:
A simple, rapid and selective method using high-performance liquid chromatography with ultraviolet detection (267 nm) was applied for the determination of tryptophan in plasma. Separation was carried out on a C18 column (150 x 4.6 mm internal diameter) in 6 min. The mobile phase consisted of 5 mM the sodium acetate and acetonitrile (92:8, v/v). The method was shown to be precise and accurate, and good recovery of analyte was achieved, characterizing the method as efficient and reliable for use in laboratory analysis.
Resumo:
A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm) column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35) and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999).
Resumo:
A fast and efficient method has been developed and validated for the determination of fipronil in bovine plasma. Samples were subjected to solid-phase extraction (SPE) followed by reversed phase liquid chromatography (LC) separation, using acetonitrile/water (60:40 v/v) as the mobile phase with a flow rate of 1.0 mL/min and ultraviolet (UV) detection at 210 nm. Ethiprole was used as the internal standard (IS). The method was found to be linear over the range 5-500 ng/mL (r = 0.999). The limit of quantitation (LOQ) was validated at 5 ng/mL. The method was successfully applied to monitor plasma concentrations following subcutaneous administration of fipronil in cattle.
Resumo:
This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.
Resumo:
Enantiomeric aglycone lignans contained in a mixture were separated from a fraction of the extract of the stems of Alibertia sessilis (Vell.) K. Schum. (Rubiaceae) by preparative high-performance liquid chromatography. An efficient and fast separation can be achieved with methanol-water (30:70, v/v). Their structures were identified as (+)-lyoniresinol 3alpha-O-beta-glucopyranoside and (-)-lyoniresinol 3alpha-O-beta-glucopyranoside, being reported for the first time in Rubiaceae.
Resumo:
The objective of this study was to optimize and validate the solid-liquid extraction (ESL) technique for determination of picloram residues in soil samples. At the optimization stage, the optimal conditions for extraction of soil samples were determined using univariate analysis. Ratio soil/solution extraction, type and time of agitation, ionic strength and pH of extraction solution were evaluated. Based on the optimized parameters, the following method of extraction and analysis of picloram was developed: weigh 2.00 g of soil dried and sieved through a sieve mesh of 2.0 mm pore, add 20.0 mL of KCl concentration of 0.5 mol L-1, shake the bottle in the vortex for 10 seconds to form suspension and adjust to pH 7.00, with alkaline KOH 0.1 mol L-1. Homogenate the system in a shaker system for 60 minutes and then let it stand for 10 minutes. The bottles are centrifuged for 10 minutes at 3,500 rpm. After the settlement of the soil particles and cleaning of the supernatant extract, an aliquot is withdrawn and analyzed by high performance liquid chromatography. The optimized method was validated by determining the selectivity, linearity, detection and quantification limits, precision and accuracy. The ESL methodology was efficient for analysis of residues of the pesticides studied, with percentages of recovery above 90%. The limits of detection and quantification were 20.0 and 66.0 mg kg-1 soil for the PVA, and 40.0 and 132.0 mg kg-1 soil for the VLA. The coefficients of variation (CV) were equal to 2.32 and 2.69 for PVA and TH soils, respectively. The methodology resulted in low organic solvent consumption and cleaner extracts, as well as no purification steps for chromatographic analysis were required. The parameters evaluated in the validation process indicated that the ESL methodology is efficient for the extraction of picloram residues in soils, with low limits of detection and quantification.
Resumo:
Large volumes of plasma can be fractionated by the method of Cohn at low cost. However, liquid chromatography is superior in terms of the quality of the product obtained. In order to combine the advantages of each method, we developed an integrated method for the production of human albumin and immunoglobulin G (IgG). The cryoprecipitate was first removed from plasma for the production of factor VIII and the supernatant of the cryoprecipitate was fractionated by the method of Cohn. The first precipitate, containing fractions (F)-I + II + III, was used for the production of IgG by the chromatographic method (see Tanaka K et al. (1998) Brazilian Journal of Medical and Biological Research, 31: 1375-1381). The supernatant of F-I + II + III was submitted to a second precipitation and F-IV was obtained and discarded. Albumin was obtained from the supernatant of the precipitate F-IV by liquid chromatography, ion-exchange on DEAE-Sepharose FF, filtration through Sephacryl S-200 HR and introduction of heat treatment for fatty acid precipitation. Viral inactivation was performed by pasteurization at 60ºC for 10 h. The albumin product obtained by the proposed procedure was more than 99% pure for the 15 lots of albumin produced, with a mean yield of 25.0 ± 0.5 g/l plasma, containing 99.0 to 99.3% monomer, 0.7 to 1.0% dimers, and no polymers. Prekallikrein activator levels were <=5 IU/ml. This product satisfies the requirements of the 1997 Pharmacopée Européenne.
Resumo:
In order to obtain intravenous immunoglobulin G (iv IgG) of high quality from F-I+II+III or F-II+III pastes prepared by the Cohn method, we developed a chromatography process using ion exchange gels, Q-Sepharose FF and CM-Sepharose FF, and Sephacryl S-300 gel filtration. Viral inactivation was performed by incubating the preparation with pepsin at pH 4.0 at 35oC for 18 h. The characteristics of 28 batches produced by us were: yield 4.3 ± 0.2 g/l plasma, i.e., a recovery of 39.1 ± 1.8%; IgG subclasses distribution: IgG1 = 58.4%, IgG2 = 34.8%, IgG3 = 4.5% and IgG4 = 2.3%; IgG size distribution was 98.4% monomers, 1.2% dimers and 0.4% polymers and protein aggregates; anticomplement activity was less than 0.5 CH50/mg IgG, and prekallikrein activator activity (PKA) was less than 5 IU/ml. These characteristics satisfied the requirements of the European Pharmacopoea edition, and the regulations of the Brazilian Health Ministry (M.S. Portaria No. 2, 30/10/1998).
Resumo:
We describe a new simple, selective and sensitive micromethod based on HPLC and fluorescence detection to measure debrisoquine (D) and 4-hydroxydebrisoquine (4-OHD) in urine for the investigation of xenobiotic metabolism by debrisoquine hydroxylase (CYP2D6). Four hundred µl of urine was required for the analysis of D and 4-OHD. Peaks were eluted at 8.3 min (4-OHD), 14.0 min (D) and 16.6 min for the internal standard, metoprolol (20 µg/ml). The 5-µm CN-reverse-phase column (Shimpack, 250 x 4.6 mm) was eluted with a mobile phase consisting of 0.25 M acetate buffer, pH 5.0, and acetonitrile (9:1, v/v) at 0.7 ml/min with detection at lexcitation = 210 nm and lemission = 290 nm. The method, validated on the basis of measurements of spiked urine, presented 3 ng/ml (D) and 6 ng/ml (4-OHD) sensitivity, 390-6240 ng/ml (D) and 750-12000 ng/ml (4-OHD) linearity, and 5.7/8.2% (D) and 5.3/8.2% (4-OHD) intra/interassay precision. The method was validated using urine of a healthy Caucasian volunteer who received one 10-mg tablet of Declinax®, po, in the morning after an overnight fast. Urine samples (diuresis of 4 or 6 h) were collected from zero to 24 h. The urinary excretion of D and 4-OHD, Fel (0-24 h), i.e., fraction of dose administered and excreted into urine, was 6.4% and 31.9%, respectively. The hydroxylation capacity index reported as metabolic ratio was 0.18 (D/4-OHD) for the person investigated and can be compared to reference limits of >12.5 for poor metabolizers (PM) and <12.5 for extensive metabolizers (EM). In parallel, the recovery ratio (RR), another hydroxylation capacity index, was 0.85 (4-OHD: SD + 4-OHD) versus reference limits of RR <0.12 for PM and RR >0.12 for EM. The healthy volunteer was considered to be an extensive metabolizer on the basis of the debrisoquine test.