970 resultados para RAP-PCR
Resumo:
Most airborne microorganisms are natural components of our ecosystem. Soil, vegetation and animals, including humans, are sources for aerial release of these living or dead cells. In the past, assessment of airborne microorganisms was mainly restricted to occupational health concerns. Indeed, in several occupations, exposure to very high concentrations of non-infectious airborne bacteria and fungi, result in allergenic, toxic or irritant reactions. Recently, the threat of bioterrorism and pandemics have highlighted the urgent need to increase knowledge of bioaerosol ecology. More fundamentally, airborne bacterial and fungal communities begin to draw much more consideration from environmental microbiologists, who have neglected this area for a long time. This increased interest of scientists is to a great part due to the development and use of real-time PCR techniques to identify and quantify airborne microorganisms. Even if the advantages of the PCR technology are obvious, researchers are confronted with new problems. This review describes the methodological state of the art in bioaerosols field and emphasizes the future challenges and perspectives of the real-time PCR-based methods for airborne microorganism studies.
Resumo:
A single-step PCR assay with genus-specific primers for the amplification of a 223-bp region of the sequence encoding a 31-kDa immunogenetic Brucella abortus protein (BCSP31) was used for the rapid diagnosis of human brucellosis. We examined peripheral blood from 47 patients, with a total of 50 cases of brucellosis, and a group of 60 control subjects, composed of patients with febrile syndromes of several etiologies other than brucellosis, asymptomatic subjects seropositive for Brucella antibodies, and healthy subjects. Diagnosis of brucellosis was established in 35 cases (70%) by isolation of Brucella in blood culture and in the other 15 cases (30%) by clinical and serological means. The sensitivity of our PCR assay was 100%, since it correctly identified all 50 cases of brucellosis, regardless of the duration of the disease, the positivity of the blood culture, or the presence of focal forms. The specificity of the test was 98.3%, and the only false-positive result was for a patient who had had brucellosis 2 months before and possibly had a self-limited relapse. In those patients who relapsed, the results of our PCR assay were positive for both the initial infection and the relapse, becoming negative once the relapse treatment was completed and remaining negative in the follow-up tests at 2, 4, and 6 months. In conclusion, these results suggest that the PCR assay is rapid and easy to perform and highly sensitive and specific, and it may therefore be considered a useful tool for diagnosis of human brucellosis.
Resumo:
In order to evaluate the diagnostic yield of a PCR assay for patients with focal complications of brucellosis, we studied by PCR and by conventional microbiological techniques 34 nonblood samples from 32 patients with different focal forms of brucellosis. The samples from patients with brucellosis were paired to an equal number of control samples from the same locations of patients whose illnesses had different etiologies. Thirty-three of the 34 nonblood samples (97%) from the brucellosis patients were positive by PCR, whereas Brucella spp. were isolated from only 29.4% of the conventional cultures. For 11.4% of the patients, the confirmatory serological tests were either negative or showed titers below the diagnostic range. Two patients (6.2%) from the control group, both with tuberculous vertebral osteomyelitis, had a positive PCR result. The brucella PCR of blood from these two patients was also positive, and the two strains of Mycobacterium tuberculosis isolated were analyzed by the brucella PCR, with no evidence of amplification. These results show that the PCR assay is far more sensitive than conventional cultures, and this, coupled with its speed and reduction in risk to laboratory workers, makes this technique a very useful tool for the diagnosis of focal complications of brucellosis.
Resumo:
We studied two of the possible factors which can interfere with specific DNA amplification in a peripheral-blood PCR assay used for the diagnosis of human brucellosis. We found that high concentrations of leukocyte DNA and heme compounds inhibit PCR. These inhibitors can be efficiently suppressed by increasing the number of washings to four or five and decreasing the amount of total DNA to 2 to 4 microg, thereby avoiding false-negative results.
Resumo:
BACKGROUND Nucleic acid amplification tests are increasingly used for the rapid diagnosis of tuberculosis. We undertook a comparative study of the efficiency and diagnostic yield of a real-time PCR senX3-regX3 based assay versus the classical IS6110 target and the new commercial methods. METHODS This single-blind prospective comparative study included 145 consecutive samples: 76 from patients with culture-confirmed tuberculosis (86.8% pulmonary and 13.2% extrapulmonary tuberculosis: 48.7% smear-positive and 51.3% smear-negative) and 69 control samples (24 from patients diagnosed with non-tuberculous mycobacteria infections and 45 from patients with suspected tuberculosis which was eventually ruled out). All samples were tested by two CE-marked assays (Xpert®MTB/RIF and AnyplexTM plus MTB/NTM) and two in-house assays targeting senX3-regX3 and the IS6110 gene. RESULTS The detection limit ranged from 1.00E+01 fg for Anyplex, senX3-regX3 and IS6110 to 1.00E+04 fg for Xpert. All three Xpert, senX3-regX3 and IS6110 assays detected all 37 smear-positive cases. Conversely, Anyplex was positive in 34 (91.9%) smear-positive cases. In patients with smear-negative tuberculosis, differences were observed between the assays; Xpert detected 22 (56.41%) of the 39 smear-negative samples, Anyplex 24 (61.53%), senX3-regX3 28 (71.79%) and IS6110 35 (89.74%). Xpert and senX3-regX3 were negative in all control samples; however, the false positive rate was 8.7% and 13% for Anyplex and IS6110, respectively. The overall sensitivity was 77.6%, 85.7%, 77.3% and 94.7% and the specificity was 100%, 100%, 90.8% and 87.0% for the Xpert, senX3-regX3, Anyplex and IS6110 assays, respectively. CONCLUSION Real-time PCR assays targeting IS6110 lack the desired specificity. The Xpert MTB/RIF and in-house senX3-regX3 assays are both sensitive and specific for the detection of MTBC in both pulmonary and extrapulmonary samples. Therefore, the real time PCR senX3-regX3 based assay could be a useful and complementary tool in the diagnosis of tuberculosis.
Resumo:
The amount of sequence data available today highly facilitates the access to genes from many gene families. Primers amplifying the desired genes over a range of species are readily obtained by aligning conserved gene regions, and laborious gene isolation procedures can often be replaced by quicker PCR-based approaches. However, in the case of multigene families, PCR-based approaches bear the often ignored risk of incomplete isolation of family members. This problem is most prominent in gene families with highly variable and thus unpredictable number of gene copies among species, such as in the major histocompatibility complex (MHC). In this study, we (i) report new primers for the isolation of the MHC class IIB (MHCIIB) gene family in birds and (ii) share our experience with isolating MHCIIB genes from an unprecedented number of avian species from all over the avian phylogeny. We report important and usually underappreciated problems encountered during PCR-based multigene family isolation and provide a collection of measures to help significantly improving the chance of successfully isolating complete multigene families using PCR-based approaches.
Resumo:
A fast method for the identification of recombinant vaccinia viruses directly from individual plaques is described. Plaques are picked, resuspended in PBS-A and processed for PCR using two 'universal' primers. The amplified sequences are analyzed by agarose gel electrophoresis. This procedure allows discrimination between spontaneously arising TK-negative mutants, which do not carry the inserted gene, and the desired TK-negative recombinants resulting from insertional inactivation of the TK gene.
Resumo:
Mycoplasma hominis is a fastidious micro-organism causing genital and extragenital infections. We developed a specific real-time PCR that exhibits high sensitivity and low intrarun and interrun variabilities. When applied to clinical samples, this quantitative PCR allowed to confirm the role of M. hominis in three patients with severe extragenital infections.
Resumo:
Originally composed of the single family Chlamydiaceae, the Chlamydiales order has extended considerably over the last several decades. Chlamydia-related bacteria were added and classified into six different families and family-level lineages: the Criblamydiaceae, Parachlamydiaceae, Piscichlamydiaceae, Rhabdochlamydiaceae, Simkaniaceae, and Waddliaceae. While several members of the Chlamydiaceae family are known pathogens, recent studies showed diverse associations of Chlamydia-related bacteria with human and animal infections. Some of these latter bacteria might be of medical importance since, given their ability to replicate in free-living amoebae, they may also replicate efficiently in other phagocytic cells, including cells of the innate immune system. Thus, a new Chlamydiales-specific real-time PCR targeting the conserved 16S rRNA gene was developed. This new molecular tool can detect at least five DNA copies and show very high specificity without cross-amplification from other bacterial clade DNA. The new PCR was validated with 128 clinical samples positive or negative for Chlamydia trachomatis or C. pneumoniae. Of 65 positive samples, 61 (93.8%) were found to be positive with the new PCR. The four discordant samples, retested with the original test, were determined to be negative or below detection limits. Then, the new PCR was applied to 422 nasopharyngeal swabs taken from children with or without pneumonia; a total of 48 (11.4%) samples were determined to be positive, and 45 of these were successfully sequenced. The majority of the sequences corresponded to Chlamydia-related bacteria and especially to members of the Parachlamydiaceae family.
Resumo:
Early treatment of meningococcal meningitis is mandatory but may negate the cerebrospinal fluid culture. Etiological diagnosis then mainly relies on PCR. Here, we report a case of false-negative results for real-time PCR for a Neisseria meningitidis serogroup B isolate with a polymorphism in the ctrA gene.
Resumo:
Résumé : Un nombre croissant de cas de malaria chez les voyageurs et migrants a été rapporté. Bien que l'analyse microscopique des frottis sanguins reste traditionnellement l'outil diagnostic de référence, sa fiabilité dépend considérablement de l'expertise de l'examinateur, pouvant elle-même faire défaut sous nos latitudes. Une PCR multiplex en temps réel a donc été développée en vue d'une standardisation du diagnostic. Un ensemble d'amorces génériques ciblant une région hautement conservée du gène d'ARN ribosomial 18S du genre Plasmodium a tout d'abord été conçu, dont le polymorphisme du produit d'amplification semblait suffisant pour créer quatre sondes spécifiques à l'espèce P. falciparum, P. malariae, P. vivax et P. ovale. Ces sondes utilisées en PCR en temps réel se sont révélées capables de détecter une seule copie de plasmide de P. falciparum, P. malariae, P. vivax et P. ovale spécifiquement. La même sensibilité a été obtenue avec une sonde de screening pouvant détecter les quatre espèces. Quatre-vingt-dix-sept échantillons de sang ont ensuite été testés, dont on a comparé la microscopie et la PCR en temps réel pour 66 (60 patients) d'entre eux. Ces deux méthodes ont montré une concordance globale de 86% pour la détection de plasmodia. Les résultats discordants ont été réévalués grâce à des données cliniques, une deuxième expertise microscopique et moléculaire (laboratoire de Genève et de l'Institut Suisse Tropical de Bâle), ainsi qu'à l'aide du séquençage. Cette nouvelle analyse s'est prononcé en faveur de la méthode moléculaire pour tous les neuf résultats discordants. Sur les 31 résultats positifs par les deux méthodes, la même réévaluation a pu donner raison 8 fois sur 9 à la PCR en temps réel sur le plan de l'identification de l'espèce plasmodiale. Les 31 autres échantillons ont été analysés pour le suivi de sept patients sous traitement antimalarique. Il a été observé une baisse rapide du nombre de parasites mesurée par la PCR en temps réel chez six des sept patients, baisse correspondant à la parasitémie déterminée microscopiquement. Ceci suggère ainsi le rôle potentiel de la PCR en temps réel dans le suivi thérapeutique des patients traités par antipaludéens. Abstract : There have been reports of increasing numbers of cases of malaria among migrants and travelers. Although microscopic examination of blood smears remains the "gold standard" in diagnosis, this method suffers from insufficient sensitivity and requires considerable expertise. To improve diagnosis, a multiplex real-time PCR was developed. One set of generic primers targeting a highly conserved region of the 18S rRNA gene of the genus Plasmodium was designed; the primer set was polymorphic enough internally to design four species-specific probes for P. falciparum, P. vivax, P. malarie, and P. ovale. Real-time PCR with species-specific probes detected one plasmid copy of P. falciparum, P. vivax, P. malariae, and P. ovale specifically. The same sensitivity was achieved for all species with real-time PCR with the 18S screening probe. Ninety-seven blood samples were investigated. For 66 of them (60 patients), microscopy and real-time PCR results were compared and had a crude agreement of 86% for the detection of plasmodia. Discordant results were reevaluated with clinical, molecular, and sequencing data to resolve them. All nine discordances between 18S screening PCR and microscopy were resolved in favor of the molecular method, as were eight of nine discordances at the species level for the species-specific PCR among the 31 samples positive by both methods. The other 31 blood samples were tested to monitor the antimalaria treatment in seven patients. The number of parasites measured by real-time PCR fell rapidly for six out of seven patients in parallel to parasitemia determined microscopically. This suggests a role of quantitative PCR for the monitoring of patients receiving antimalaria therapy.
Resumo:
Échelle(s) : [ca 1:200 000], échelle de 0,01 pour 2000 mètres
Resumo:
The performance of the Xpert MRSA polymerase chain reaction (PCR) assay on pooled nose, groin, and throat swabs (three nylon flocked eSwabs into one tube) was compared to culture by analyzing 5,546 samples. The sensitivity [0.78, 95 % confidence interval (CI) 0.73-0.82] and specificity (0.99, 95 % CI 0.98-0.99) were similar to the results from published studies on separated nose or other specimens. Thus, the performance of the Xpert MRSA assay was not affected by pooling the three specimens into one assay, allowing a higher detection rate without increasing laboratory costs, as compared to nose samples alone.
Resumo:
Keskushermosto- ja neonataali-infektiot ovat herpes simplex -virusten aiheuttamista taudeista vakavimpia. Niihin on olemassa lääkitys, joka on tehokkain, kun se aloitetaan aivan sairauden alkuvaiheessa. Näiden infektioiden diagnostiikassa PCR-menetelmä on herkin. Tämä menetelmä on kuitenkin työläs ja aikaa vievä, joten uudet nopeammat menetelmät ovat tervetulleita. Opinnäytetyö tehtiin HUSLABin virologian osastolle. Työssä testattiin QIAGENIN artus®HSV-1/2 LC PCR-reagenssipakkausta, joka on tehty käytettäväksi Roche diagnosticsin reaaliaikaisella PCR-laitteella LightCyclerillä. Lisäksi työssä testattiin automaattista bioMérieuxin NucliSens easyMAG- nukleiinihappoeristyslaitetta. Referenssinä käytettiin HUSLABin virologian osastolla testaushetkellä käytössä olevia menetelmiä. Reaaliaikaisen PCR-menetelmän herkkyyttä testattiin positiivisilla HSV-1 ja HSV-2 kontrollilaimennussarjoilla. Menetelmän oikeellisuutta testattiin määrittämällä laaduntarkkailu- ja potilasnäytteitä, jotka olivat likvoria. Tuloksia verrattiin QCMD:n antamiin ja perinteisellä ”in house”- PCR-menetelmällä saatuihin referenssituloksiin. Spesifisyyttä testattiin muiden ihmisten herpesvirusten positiivisilla kontrolleilla. Automaattisen nukleiinihappoeristysmenetelmän toimivuutta testattiin HSV-positiivisilla ja -negatiivisilla likvornäytteillä, jotka oli aikaisemmin eristetty fenoli-kloroformiuutolla. Tulokset QIAGENIN artus®HSV-1/2 LC PCR-reagenssipakkauksesta olivat hyviä. Kont-rollilaimennussarjan määrityksessä reaaliaikainen PCR-menetelmä osoittautui perinteistä ”in house”- PCR-menetelmää herkemmäksi. Potilasnäytteiden määrityksessä tulokset olivat yhtenevät. EasyMAG- nukleiinihappoeristysmenetelmällä eristettyjen potilasnäytteiden määrityksistä saadut tulokset olivat myös hyviä. Kun tuloksia verrattiin fenoli-kloroformiuutolla saatuihin tuloksiin, olivat tulokset yhtä näytettä lukuun ottamatta yhtenevät. Molemmat testattavat menetelmät ovat nopeita ja virhelähteiden mahdollisuus on vähäisempi kuin perinteisessä ”in house”-PCR menetelmässä ja fenoli-kloroformiuutolla nukleiinihappoa eristettäessä. Tutkimusten tulokset osoittivat molempien menetelmien soveltuvan hyvin HSV:n eristykseen ja määritykseen likvornäytteistä.