1000 resultados para Percepción visual
Resumo:
To validate clinically an algorithm for correcting the error in the keratometric estimation of corneal power by using a variable keratometric index of refraction (nk) in a normal healthy population.
Resumo:
We show that subwavelength diffracted wave fields may be managed inside multilayered plasmonic devices to achieve ultra-resolving lensing. For that purpose we first transform both homogeneous waves and a broad band of evanescent waves into propagating Bloch modes by means of a metal/dielectric (MD) superlattice. Beam spreading is subsequently compensated by means of negative refraction in a plasmon-induced anisotropic effective-medium that is cemented behind. A precise design of the superlens doublet may lead to nearly aberration-free images with subwavelength resolution in spite of using optical paths longer than a wavelength.
Resumo:
Roman seals associated with collyria (Latin expression for eye drops /washes and lotions for eye maintenance) provide valuable information about eye care in the antiquity. These small, usually stone-made pieces bore engravings with the names of eye doctors and also the collyria used to treat an eye disease. The collyria seals have been found all over the Roman empire and Celtic territories in particular and were usually associated with military camps. In Hispania (Iberian Peninsula), only three collyria seals have been found. These findings speak about eye care in this ancient Roman province as well as about of the life of the time. This article takes a look at the utility and social significance of the collyria seals and seeks to give an insight in the ophthalmological practice of in the Roman Empire.
Resumo:
Presentamos un caso de pérdida de agudeza visual unilateral no explicable por factores corneales o retinianos en el que se detecta un lenticono posterior mediante tecnología de cámara Scheimpflug. En concreto, se trata de una paciente de 7 años de edad que acude con una disminución de la agudeza visual del ojo derecho desde hacía tres años. La agudeza visual del ojo derecho en lejos es de 0,3 con la mejor corrección y de cerca de 0,8. Se observaron reflejos retinoscópicos en tijera, así como la presencia de una pequeña opacidad lenticular polar posterior mediante biomicroscopía. No tenía antecedentes de patología ocular ni presentaba ninguna alteración compatible con el síndrome de Alport o el síndrome de Morning Glory, así como tampoco presentaba ningún tipo de alergia. Mediante un análisis con un sistema basado en tecnología de cámara Scheimpflug se pudo detectar un encurvamiento de la cara posterior del cristalino, confirmando el diagnóstico de lenticono posterior. La pérdida visual puede ser debida a que el lenticono se encuentra en la zona paracentral del cristalino, pudiendo también contribuir la opacidad congénita del cristalino. En conclusión, el ópticooptometrista, como primer eslabón en la atención visual primaria, puede pensar en el potencial diagnóstico de lenticono cuando no existe una pérdida de agudeza visual sin causa corneal, retiniana o refractiva que lo justifique, siendo la tecnología de cámara Scheimpflug muy útil para la confirmación del diagnóstico.
Resumo:
Se presenta un caso clínico con solución de lente de contacto cosmética para una paciente con midriasis máxima irrefléxica provocada por una complicación en cirugía de cataratas. El caso se complica al tener la paciente, además, una endo e hipertropía en ojo izquierdo (OI). Se realiza un estudio optométrico y contactológico en profundidad para establecer la idoneidad del tratamiento elegido y la solución propuesta y aceptada, que es la de adaptar una LC de material biocompatible y trabajada artesanalmente. Con ella se consigue un resultado muy natural y nos aseguramos que el material respeta por completo la fisiología del ojo. Después de una serie de pruebas adaptativas se consigue dotar a la paciente de la comodidad y similitud facial inicialmente consideradas en la primera visita, quedando así subsanada estéticamente esta atrofia ocular inicial.
Resumo:
Purpose: To define a range of normality for the vectorial parameters Ocular Residual Astigmatism (ORA) and topography disparity (TD) and to evaluate their relationship with visual, refractive, anterior and posterior corneal curvature, pachymetric and corneal volume data in normal healthy eyes. Methods: This study comprised a total of 101 consecutive normal healthy eyes of 101 patients ranging in age from 15 to 64 years old. In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system (Pentacam system Oculus Optikgeräte GmbH). Anterior corneal topographic data were imported from the Pentacam system to the iASSORT software (ASSORT Pty. Ltd.), which allowed the calculation of the ocular residual astigmatism (ORA) and topography disparity (TD). Linear regression analysis was used for obtaining a linear expression relating ORA and posterior corneal astigmatism (PCA). Results: Mean magnitude of ORA was 0.79 D (SD: 0.43), with a normality range from 0 to 1.63 D. 90 eyes (89.1%) showed against-the-rule ORA. A weak although statistically significant correlation was found between the magnitudes of posterior corneal astigmatism and ORA (r = 0.34, p < 0.01). Regression analysis showed the presence of a linear relationship between these two variables, although with a very limited predictability (R2: 0.08). Mean magnitude of TD was 0.89 D (SD: 0.50), with a normality range from 0 to 1.87 D. Conclusion: The magnitude of the vector parameters ORA and TD is lower than 1.9 D in the healthy human eye.
Resumo:
Interest in corneal biomechanics has increased with the development of new refractive surgery techniques aimed at modifying corneal properties and a variety of surgical options for corneal ectasia management. The human cornea behaves as soft biological material. It is a viscoelastic tissue and its response to a force applied to it depends not only on the magnitude of the force, but also on the velocity of the application. There are concerns about the limitations to measuring corneal biomechanical properties in vivo. To date, 2 systems are available for clinical use: the Ocular Response Analyzer, a dynamic bidirectional applanation device, and the Corvis ST, a dynamic Scheimpflug analyzer device. These devices are useful in clinical practice, especially for planning some surgical procedures and earlier detection of ectatic conditions, but further research is needed to connect the clinical measurements obtained with these devices to the standard mechanical properties.
Resumo:
Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.
Resumo:
Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.
Resumo:
Background To evaluate the 3-year clinical outcomes after toric implantable collamer lens (ICL) implantation for the management of moderate to high myopic astigmatism. Methods Thirty-four eyes of 20 patients who underwent toric ICL implantation were reviewed. All eyes completed 3-year follow-up. Uncorrected (UDVA) and corrected (CDVA) distance LogMAR visual acuities, refraction, endothelial cell density (ECD), and surgical complications were evaluated. Vectorial analysis of astigmatic correction was also done. Results A significant improvement in UDVA, CDVA, manifest spherical and cylindrical refraction was observed at 1 week and remained stable after 3 years. Twenty-six eyes (76.5 %) gained lines of CDVA, and two eyes (5.9 %) showed a loss of 1 line of CDVA. The spherical equivalent (SE) was within ±0.50 D of emmetropia in 18 eyes (52.9 %) and within ±1.00 D in 28 eyes (82.4 %). Differences between target-induced astigmatism (TIA) and surgically-induced astigmatism (SIA) were statistically significant (p < 0.01), and a trend to undercorrection of the refractive astigmatism was present after 3 years. The magnitude of flattening effect (FE) was found to be significantly lower than the magnitude of TIA (p < 0.01). The magnitude of the torque vector was always positive, with a value below 0.50 D in all cases. No vision-threatening complications were observed during the follow-up. Conclusion Toric ICL implantation is an effective and safe surgical option that provides a relatively predictable and stable refractive correction of myopic astigmatism. Further improvements are needed to minimize the degree of undercorrection.
Resumo:
Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.
Resumo:
Background To analyze and compare the relationship between anterior and posterior corneal shape evaluated by a tomographic system combining the Scheimpflug photography and Placido-disc in keratoconus and normal healthy eyes, as well as to evaluate its potential diagnostic value. Methods Comparative case series including a sample of 161 eyes of 161 subjects with ages ranging from 7 to 66 years and divided into two groups: normal group including 100 healthy eyes of 100 subjects, and keratoconus group including 61 keratoconus eyes of 61 patients. All eyes received a comprehensive ophthalmologic examination including an anterior segment analysis with the Sirius system (CSO). Antero-posterior ratios for corneal curvature (k ratio) and shape factor (p ratio) were calculated. Logistic regression analysis was used to evaluate if some antero–posterior ratios combined with other clinical parameters were predictors of the presence of keratoconus. Results No statistically significant differences between groups were found in the antero–posterior k ratios for 3-, 5- and 7-mm diameter corneal areas (p ≥ 0.09). The antero–posterior p ratio for 4.5- and 8-mm diameter corneal areas was significantly higher in the normal group than in the keratoconus group (p < 0.01). The k ratio for 3, 5, and 7 mm was significantly higher in the keratoconus grade IV subgroup than in the normal group (p < 0.01). Furthermore, significant differences were found in the p ratio between the normal group and the keratoconus grade II subgroup (p ≤ 0.01). Finally, the logistic regression analysis identified as significant independent predictors of the presence of keratoconus (p < 0.01) the 8-mm anterior shape factor, the anterior chamber depth, and the minimal corneal thickness. Conclusions The antero-posterior k and p ratios are parameters with poor prediction ability for keratoconus, in spite of the trend to the presence of more prolate posterior corneal surfaces compared to the anterior in keratoconus eyes.