Ocular residual astigmatism and topographic disparity vector indexes in normal healthy eyes


Autoria(s): Piñero, David P.; Ruiz Fortes, Pedro; Pérez Cambrodí, Rafael J.; Mateo Pérez, Verónica; Artola, Alberto
Contribuinte(s)

Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía

Grupo de Óptica y Percepción Visual (GOPV)

Data(s)

30/05/2014

30/05/2014

01/02/2014

Resumo

Purpose: To define a range of normality for the vectorial parameters Ocular Residual Astigmatism (ORA) and topography disparity (TD) and to evaluate their relationship with visual, refractive, anterior and posterior corneal curvature, pachymetric and corneal volume data in normal healthy eyes. Methods: This study comprised a total of 101 consecutive normal healthy eyes of 101 patients ranging in age from 15 to 64 years old. In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system (Pentacam system Oculus Optikgeräte GmbH). Anterior corneal topographic data were imported from the Pentacam system to the iASSORT software (ASSORT Pty. Ltd.), which allowed the calculation of the ocular residual astigmatism (ORA) and topography disparity (TD). Linear regression analysis was used for obtaining a linear expression relating ORA and posterior corneal astigmatism (PCA). Results: Mean magnitude of ORA was 0.79 D (SD: 0.43), with a normality range from 0 to 1.63 D. 90 eyes (89.1%) showed against-the-rule ORA. A weak although statistically significant correlation was found between the magnitudes of posterior corneal astigmatism and ORA (r = 0.34, p < 0.01). Regression analysis showed the presence of a linear relationship between these two variables, although with a very limited predictability (R2: 0.08). Mean magnitude of TD was 0.89 D (SD: 0.50), with a normality range from 0 to 1.87 D. Conclusion: The magnitude of the vector parameters ORA and TD is lower than 1.9 D in the healthy human eye.

Identificador

Contact Lens and Anterior Eye. 2014, 37(1): 49-54. doi:10.1016/j.clae.2013.07.006

1367-0484 (Print)

1476-5411 (Online)

http://hdl.handle.net/10045/37740

10.1016/j.clae.2013.07.006

Idioma(s)

eng

Publicador

Elsevier

Relação

http://dx.doi.org/10.1016/j.clae.2013.07.006

Direitos

© 2013 British Contact Lens Association. Published by Elsevier Ltd.

info:eu-repo/semantics/restrictedAccess

Palavras-Chave #Ocular residual astigmatism #Posterior corneal astigmatism #Topography disparity #Corneal astigmatism #Óptica
Tipo

info:eu-repo/semantics/article