925 resultados para Knee kinematics
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective To assess the diagnostic accuracy of the surface electromyography (sEMG) parameters associated with referred anterior knee pain in diagnosing patellofemoral pain syndrome (PFPS). Design Sensitivity and specificity analysis. Setting Physical rehabilitation center and laboratory of biomechanics and motor control. Participants Pain-free subjects (n=29) and participants with PFPS (n=22) selected by convenience. Interventions Not applicable. Main Outcome Measure The diagnostic accuracy was calculated for sEMG parameters’ reliability, precision, and ability to differentiate participants with and without PFPS. The selected sEMG parameter associated with anterior knee pain was considered as an index test and was compared with the reference standard for the diagnosis of PFPS. Intraclass correlation coefficient, SEM, independent t tests, sensitivity, specificity, negative and positive likelihood ratios, and negative and positive predictive values were used for the statistical analysis. Results The medium-frequency band (B2) parameter was reliable (intraclass correlation coefficient=.80–.90), precise (SEM=2.71–3.87 normalized unit), and able to differentiate participants with and without PFPS (P<.05). The association of B2 with anterior knee pain showed positive diagnostic accuracy values (specificity, .87; sensitivity, .70; negative likelihood ratio, .33; positive likelihood ratio, 5.63; negative predictive value, .72; and positive predictive value, .86). Conclusions The results provide evidence to support the use of EMG signals (B2 – frequency band of 45–96Hz) of the vastus lateralis and vastus medialis muscles with referred anterior knee pain in the diagnosis of PFPS.
Resumo:
Several machining processes have been created and improved in order to achieve the best results ever accomplished in hard and difficult to machine materials. Some of these abrasive manufacturing processes emerging on the science frontier can be defined as ultra-precision grinding. For finishing flat surfaces, researchers have been putting together the main advantages of traditional abrasive processes such as face grinding with constant pressure, fixed abrasives for two-body removal mechanism, total contact of the part with the tool, and lapping kinematics as well as some specific operations to keep grinding wheel sharpness and form. In the present work, both U d-lap grinding process and its machine tool were studied aiming nanometric finishing on flat metallic surfaces. Such hypothesis was investigated on AISI 420 stainless steel workpieces U d-lap ground with different values of overlap factor on dressing (Ud=1, 3, and 5) and grit sizes of conventional grinding wheels (silicon carbide (SiC)=#800, #600, and #300) applying a new machine tool especially designed and built for such finishing. The best results, obtained after 10 min of machining, were average surface roughness (Ra) of 1.92 nm, 1.19-μm flatness deviation of 25.4-mm-diameter workpieces, and mirrored surface finishing. Given the surface quality achieved, the U d-lap grinding process can be included among the ultra-precision abrasive processes and, depending on the application, the chaining steps of grinding, lapping, and polishing can be replaced by the proposed abrasive process.
Resumo:
Wild bearded capuchins (Cebus libidinosus, quadrupedal, medium-sized monkeys) crack nuts using large stones. We examined the kinematics and energetics of the nut-cracking action of two adult males and two adult females. From a bipedal stance, the monkeys raised a heavy hammer stone (1.46 and 1.32 kg, from 33 to 77% of their body weight) to an average height of 0.33 m, 60% of body length. Then, they rapidly lowered the stone by flexing the lower extremities and the trunk until the stone contacted the nut. A hit consisting of an upward phase and a downward phase averaged 0.74 s in duration. The upward phase lasted 69% of hit duration. All subjects added discernable energy to the stone in the downward phase. The monkeys exhibited individualized kinematic strategies, similar to those of human weight lifters. Capuchins illustrate that human-like bipedal stance and large body size are unnecessary to break tough objects from a bipedal position. The phenomenon of bipedal nut-cracking by capuchins provides a new comparative reference point for discussions of percussive tool use and bipedality in primates. Am J Phys Anthropol 138:210-220, 2009. (C) 2008 Wiley-Liss, Inc.
Resumo:
This paper presents further results from our spectroscopic study of the globular cluster (GC) system of the group elliptical NGC 3923. From observations made with the GMOS instrument on the Gemini South Telescope, an additional 50 GC and ultra-compact dwarf (UCD) candidates have been spectroscopically confirmed as members of the NGC 3923 system. When the recessional velocities of these GCs are combined with the 29 GC velocities reported previously, a total sample of 79 GC/UCD velocities is produced. This sample extends to over 6 arcmin (>6 R-e similar to 30 kpc) from the centre of NGC 3923 and is used to study the dynamics of the GC system and the dark matter content of NGC 3923. It is found that the GC system of NGC 3923 displays no appreciable rotation, and that the projected velocity dispersion is constant with radius within the uncertainties. The velocity dispersion profiles of the integrated light and GC system of NGC 3923 are indistinguishable over the region in which they overlap. We find some evidence that the diffuse light and GCs of NGC 3923 have radially biased orbits within similar to 130 arcsec. The application of axisymmetric orbit-based models to the GC and integrated light velocity dispersion profiles demonstrates that a significant increase in the mass-to-light ratio (from M/L-V = 8 to 26) at large galactocentric radii is required to explain this observation. We therefore confirm the presence of a dark matter halo in NGC 3923. We find that dark matter comprises 17.5(-4.5)(+7.3) per cent of the mass within 1 R-e, 41.2(-10.6)(+18.2) per cent within 2 R-e and 75.6(-16.8)(+15.4) per cent within the radius of our last kinematic tracer at 6.9 R-e. The total dynamical mass within this radius is found to be 1.5(-0.25)(+0.4) x 10(12) M-circle dot. In common with other studies of large ellipticals, we find that our derived dynamical mass profile is consistently higher than that derived by X-ray observations, by a factor of around 2.
Resumo:
BALDON, R. D. M., D. F. M. LOBATO, L. P. CARVALHO, P. Y. L. WUN, P. R. P. SANTIAGO, and F. V. SERRAO. Effect of Functional Stabilization Training on Lower Limb Biomechanics in Women. Med. Sci. Sports Exerc., Vol. 44, No. 1, pp. 135-145, 2012. Purpose: This study aimed to verify the effects of functional stabilization training on lower limb kinematics, functional performance, and eccentric hip and knee torques. Methods: Twenty-eight women were divided into a training group (TG; n = 14), which carried out the functional stabilization training during 8 wk, and a control group (CG; n = 14), which carried out no physical training. The kinematic assessment of the lower limb was performed during a single-leg squat, and the functional performance was evaluated by way of the single-leg triple hop and the timed 6-m single-leg hop tests. The eccentric hip abductor, adductor, lateral rotator, medial rotator, and the knee flexor and extensor torques were measured using an isokinetic dynamometer. Results: After 8 wk, the TG significantly reduced the values for knee abduction (from -6.86 degrees to 1.49 degrees), pelvis depression (from -10.21 degrees to -7.86 degrees) and femur adduction (from 7.08 degrees to 5.19 degrees) as well as increasing the excursion of femur lateral rotation (from -0.55 degrees to -3.67 degrees). Similarly, the TG significantly increased the values of single-leg triple hop (from 3.52 to 3.92 m) and significantly decreased the values of timed 6-m single-leg hop tests (from 2.43 to 2.14 s). Finally, the TG significantly increased the eccentric hip abductor (from 1.31 to 1.45 N center dot m center dot kg(-1)), hip lateral rotator (from 0.75 to 0.91 N center dot m center dot kg(-1)), hip medial rotator (from 1.45 to 1.66 N center dot m center dot kg(-1)), knee flexor (from 1.43 to 1.55 N center dot m center dot kg(-1)), and knee extensor (from 3.46 to 4.40 N center dot m center dot kg(-1)) torques. Conclusions: Strengthening of the hip abductor and lateral rotator muscles associated with functional training improves dynamic lower limb alignment and increases the strength and functional performance.
Resumo:
The origin of cosmic rays at all energies is still uncertain. In this paper, we present and explore an astrophysical scenario to produce cosmic rays with energy ranging from below 10(15) to 3 x 10(20) eV. We show here that just our Galaxy and the radio galaxy Cen A, each with their own galactic cosmic-ray particles but with those from the radio galaxy pushed up in energy by a relativistic shock in the jet emanating from the active black hole, are sufficient to describe the most recent data in the PeV to near ZeV energy range. Data are available over this entire energy range from the KASCADE, KASCADE-Grande, and Pierre Auger Observatory experiments. The energy spectrum calculated here correctly reproduces the measured spectrum beyond the knee and, contrary to widely held expectations, no other extragalactic source population is required to explain the data even at energies far below the general cutoff expected at 6 x 10(19) eV, the Greisen-Zatsepin-Kuz'min turnoff due to interaction with the cosmological microwave background. We present several predictions for the source population, the cosmic-ray composition, and the propagation to Earth which can be tested in the near future.
Resumo:
Objective: To translate, culturally adapt and validate the "Knee Society Score"(KSS) for the Portuguese language and determine its measurement properties, reproducibility and validity. Method: We analyzed 70 patients of both sexes, aged between 55 and 85 years, in a cross-sectional clinical trial, with diagnosis of primary osteoarthritis,undergoing total knee arthroplasty surgery. We assessed the patients with the English version of the KSS questionnaire and after 30 minutes with the Portuguese version of the KSS questionnaire, done by a different evaluator. All the patients were assessed preoperatively, and again at three, and six months postoperatively. Results: There was no statistical difference, using Cronbach's alpha index and the Bland-Altman graphical analysis, for the knees core during the preoperative period (p=1), and at three months (p=0.991) and six months postoperatively (p=0.985). There was no statistical difference for knee function score for all three periods (p=1.0). Conclusion: The Brazilian version of the Knee Society Score is easy to apply, as well providing as a valid and reliable instrument for measuring the knee score and function of Brazilian patients undergoing TKA. Level of Evidence: Level I - Diagnostic Studies Investigating a Diagnostic Test- Testing of previously developed diagnostic criteria on consecutive patients (with universally applied 'gold' reference standard).
Resumo:
Objectives: To estimate the effects of low level laser therapy in combination with a programme of exercises on pain, functionality, range of motion, muscular strength and quality of life in patients with osteoarthritis of the knee. Design: A randomized double-blind placebo-controlled trial with sequential allocation of patients to different treatment groups. Setting: Special Rehabilitation Services. Subjects: Forty participants with knee osteoarthritis, 2-4 osteoarthritis degree, aged between 50 and 75 years and both genders. Intervention: Participants were randomized into one of two groups: the laser group (low level laser therapy dose of 3 J and exercises) or placebo group (placebo laser and exercises). Main measures: Pain was assessed using a visual analogue scale (VAS), functionality using the Lequesne questionnaire, range of motion with a universal goniometer, muscular strength using a dynamometer, and activity using the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) questionnaire at three time points: (T1) baseline, (T2) after the end of laser therapy (three weeks) and (T3) the end of the exercises (11 weeks). Results: When comparing groups, significant differences in the activity were also found (P = 0.03). No other significant differences (P > 0.05) were observed in other variables. In intragroup analysis, participants in the laser group had significant improvement, relative to baseline, on pain (P = 0.001), range of motion (P = 0.01), functionality (P = 0.001) and activity (P < 0.001). No significant improvement was seen in the placebo group. Conclusion: Our findings suggest that low level laser therapy when associated with exercises is effective in yielding pain relief, function and activity on patients with osteoarthritis of the knees.
Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101
Resumo:
Background. Further clarification is needed with regard to the degree of atrophy in individual muscle groups and its possible relationship to joint torque deficit poststroke. Objective. The purpose of this study was to investigate quadriceps and hamstring muscle volume and strength deficits of the knee extensors and flexors in people with chronic hemiparesis compared with a control group. Design. This was a cross-sectional study. Methods. Thirteen individuals with hemiparesis due to chronic stroke (hemiparetic group) and 13 individuals who were healthy (control group) participated in this study. Motor function, quadriceps and hamstring muscle volume, and maximal concentric and eccentric contractions of the knee extensors and flexors were assessed. Results. Only the quadriceps muscle of the paretic limb showed reduced muscle volume (24%) compared with the contralateral (nonparetic) limb. There were no differences in muscle volume between the hemiparetic and control groups. The peak torque of the paretic-limb knee extensors and flexors was reduced in both contraction modes and velocities compared with the nonparetic limb (36%-67%) and with the control group (49%-75%). The nonparetic limb also showed decreased extensor and flexor peak torque compared with the control group (17%-23%). Power showed similar deficits in strength (12%-78%). There were significant correlations between motor function and strength deficits (.54-.67). Limitations. Magnetic resonance imaging coil length did not allow measurement of the proximal region of the thigh. Conclusions. There were different responses between quadriceps and hamstring muscle volumes in the paretic limb that had quadriceps muscle atrophy only. However, both paretic and nonparetic limbs showed knee extensor and flexor torque and power reduction.
Resumo:
Intensive scheduling in sports requires athletes to resume physical activity shortly after injury. The purpose of this study was to investigate early isokinetic muscle strength and knee function on bone-patellar tendon-bone (BPTB) ACL reconstruction with double femoral pin fixation or interference screw technique. A prospective study was conducted from 2008 to 2009, with 48 athletes who received femoral BPTB fixation with interference screw (n = 26) or double pin (n = 22). Clinical (IKDC objective score and hop test) and isokinetic muscle strength (peak torque (PT), PT/body weight and flexion/extension rate (F/E) in 60 and 240A degrees/s) were analyzed at 6 months of follow-up. Analysis at baseline showed no differences between groups before surgery related to age, gender, associated injury, Tegner or Lysholm score; thus showing that groups were similar. During follow-up, however, there were significant differences between the two groups in some of the isokinetic muscle strength: PT/BW 60A degrees/s (Double Pin = 200% +/- A 13% vs. Interference Screw = 253% +/- A 16%*, *P = 0.01); F/E 60A degrees/s (Double Pin = 89% +/- A 29%* vs. Interference Screw = 74% +/- A 12%, *P = 0.04). No statistical differences between groups were observed on IKDC objective score, hop test and complications. The significant muscle strength outcome of the interference screw group found in this study gives initial evidence that this fixation technique is useful for athletes that may need accelerated rehabilitation. Early return to sports ability signaled by isokinetic muscle strength is of clinical relevance as it is one of the main goals for athletes' rehabilitation. III.
Resumo:
Objectives: To compare stabilometric parameters of elderly female fallers and non-fallers associated or not with knee osteoarthritis (OA). Methods: Fifty-six elderly female fallers and non-fallers diagnosed or not with unilateral or bilateral knee OA were divided into the following groups: FOA (n = 10), elderly female falters with knee OA; FNOA (n = 11), elderly female fallers without knee OA; NFOA (n = 14), elderly female non-fallers with knee OA; and NFNOA (n = 21), elderly female non-fallers without knee OA. For analyzing semi-static balance on a force platform with the elderly females standing, the following parameters were assessed in four conditions: center of pressure (COP), anterior-posterior and mediolateral displacements (APD and MLD, respectively); and COP anterior-posterior and mediolateral displacement velocities (APV and MLV, respectively). The following conditions were assessed: 1) standing on a firm wooden surface with eyes open (WSEO); 2) standing on a firm wooden surface with eyes closed (WSEC); 3) standing on a foam surface with eyes open (FSEO); 4) standing on a foam surface with eyes closed (FSEC). Results: The elderly females with knee OA showed greater APD in all four conditions assessed (P < 0.05), while the elderly female fallers showed greater MLD (P < 0.05). No difference between the groups was observed for APV and MLV (P > 0.05). Conclusions: Knee OA per se increases APD of the COP, while the history of falls, regardless of the presence of knee OA, hinders postural control in the ML direction.
Resumo:
Arthritis of the knee is the most common type of joint inflammatory disorder and it is associated with pain and inflammation of the joint capsule. Few studies address the effects of the 810-nm laser in such conditions. Here we investigated the effects of low-level laser therapy (LLLT; infrared, 810-nm) in experimentally induced rat knee inflammation. Thirty male Wistar rats (230-250 g) were anesthetized and injected with carrageenan by an intra-articular route. After 6 and 12 h, all animals were killed by CO(2) inhalation and the articular cavity was washed for cellular and biochemical analysis. Articular tissue was carefully removed for real-time PCR analysis in order to evaluate COX-1 and COX-2 expression. LLLT was able to significantly inhibit the total number of leukocytes, as well as the myeloperoxidase activity with 1, 3, and 6 J (Joules) of energy. This result was corroborated by cell counting showing the reduction of polymorphonuclear cells at the inflammatory site. Vascular extravasation was significantly inhibited at the higher dose of energy of 10 J. Both COX-1 and 2 gene expression were significantly enhanced by laser irradiation while PGE(2) production was inhibited. Low-level laser therapy operating at 810 nm markedly reduced inflammatory signs of inflammation but increased COX-1 and 2 gene expression. Further studies are necessary to investigate the possible production of antiinflammatory mediators by COX enzymes induced by laser irradiation in knee inflammation.
Resumo:
Background: The progression of diabetes and the challenge of daily tasks may result in changes in biomechanical strategies. Descending stairs is a common task that patients have to deal with, however it still has not been properly studied in this population. Objectives: We describe and compare the net joint moments and kinematics of the lower limbs in diabetic individuals with and without peripheral neuropathy and healthy controls during stair descent. Method: Forty-two adults were assessed: control group (13), diabetic group (14), and neuropathic diabetic group (15). The flexor and extensor net moment peaks and joint angles of the hip, knee, and ankle were described and compared in terms of effect size and ANOVAs (p<0.05). Results: Both diabetic groups presented greater dorsiflexion [large effect size] and a smaller hip extensor moment [large effect size] in the weight acceptance phase. In the propulsion phase, diabetics with and without neuropathy showed a greater hip flexor moment [large effect size] and smaller ankle extension [large effect size]. Conclusion: Diabetic patients, even without neuropathy, revealed poor eccentric control in the weight acceptance phase, and in the propulsion phase, they showed a different hip strategy, where they chose to take the leg off the ground using more flexion torque at the hip instead of using a proper ankle extension function.