881 resultados para Interaction modeling. Model-based development. Interaction evaluation.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The use of standard reference electrodes, such as Ag/AgCl or saturated calomel electrodes, in potentiometric and amperometric studies involving miniaturized electrochemical systems, or those operating under positive hydraulic pressure, is often impractical. Placement of the reference electrode in the direct vicinity of the working electrode is often prohibited by the dimensions or layout of the electrochemical cell, while the alternative strategy of locating the reference electrode in a separate compartment often leads to electrolyte leakage and contamination of the system. In the present study, we have investigated the functionality of a pseudoreference electrode comprising a platinum wire, one end of which was maintained in intimate contact with the internal solution of an Ag/AgCl reference electrode while the other was connected, via a BNC connector, to a platinum probe located within the electrochemical cell. Linear and cyclic voltammetric studies, involving both aqueous and nonaqueous electrolytes, were carried out using the pseudoreference electrode and an electrochemical cup-type cell with three electrodes or an electrochemical flow reactor. In all cases, the functionality of the Pt//Ag/AgCl system was similar to that of a conventional Ag/AgCl reference electrode. Variations in the electrolyte did not alter the potential or voltammetric profile recorded when using the pseudoreference system, although peak currents were generally improved and potential values shifted by approximately +350 mV in comparison with the Ag/AgCl electrode, therefore, the system pseudoreference can be applied in any electrochemical system due to the constant potential difference. It is concluded that the pseudoreference electrode can be used with advantage to obtain potentiometric and amperometric measurements in both simple and complex electrochemical systems.
Resumo:
A neural network model to predict ozone concentration in the Sao Paulo Metropolitan Area was developed, based on average values of meteorological variables in the morning (8:00-12:00 hr) and afternoon (13:00-17: 00 hr) periods. Outputs are the maximum and average ozone concentrations in the afternoon (12:00-17:00 hr). The correlation coefficient between computed and measured values was 0.82 and 0.88 for the maximum and average ozone concentration, respectively. The model presented good performance as a prediction tool for the maximum ozone concentration. For prediction periods from 1 to 5 days 0 to 23% failures (95% confidence) were obtained.
Resumo:
The behavior of composed Web services depends on the results of the invoked services; unexpected behavior of one of the invoked services can threat the correct execution of an entire composition. This paper proposes an event-based approach to black-box testing of Web service compositions based on event sequence graphs, which are extended by facilities to deal not only with service behavior under regular circumstances (i.e., where cooperating services are working as expected) but also with their behavior in undesirable situations (i.e., where cooperating services are not working as expected). Furthermore, the approach can be used independently of artifacts (e.g., Business Process Execution Language) or type of composition (orchestration/choreography). A large case study, based on a commercial Web application, demonstrates the feasibility of the approach and analyzes its characteristics. Test generation and execution are supported by dedicated tools. Especially, the use of an enterprise service bus for test execution is noteworthy and differs from other approaches. The results of the case study encourage to suggest that the new approach has the power to detect faults systematically, performing properly even with complex and large compositions. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
Antigen-kodierende RNA wird als eine sichere und effiziente Alternative zu traditionellen Impfstoff-Formulierungen, wie Peptid-, Protein-, rekombinanten viralen oder DNA basierten Impfstoffen betrachtet. Der endgültige klinische Nutzen RNA-basierter Impfstoffe wird von der Optimierung verschiedener Parameter abhängig sein, die zur Induktion und effizienten Expansion der humoralen und zellvermittelten Immunantwort beitragen. Vor diesem Hintergrund war die Zielsetzung der vorliegenden Arbeit, die Etablierung pharmakologischer und immunologischer Parameter für die Generierung effektiver Immunantworten durch RNA-Impfstoffe sowie deren Wirksamkeit in vitro und im Mausmodell unter Nutzung von Modellantigenen zu testen. Zur Untersuchung und Optimierung der RNA-Pharmakokinetik, als einem Schlüsselaspekt der klinischen Medikamentenentwicklung, wurde der Einfluss von strukturellen Modifikationen auf die Transkriptstabilität und Translationseffizienz von Reporter-Proteinen in einer zeitabhängigen Kinetik evaluiert. Es wurde gezeigt, dass ein poly(A) Schwanz von 120 Adenosinen, verglichen mit einem kürzeren, ein freies 3´ poly(A) Ende, verglichen mit einem verdeckten und eine doppelte β-globin 3´ UTR, unabhängig voneinander zu einer Erhöhung der IVT-RNA Stabilität und zu einer Verbesserung der Translationseffizienz beitrugen und dadurch insgesamt zu einer erhöhten Proteinexpression führten. Antigen-kodierende IVT-RNA mit diesen molekularen Merkmalen in Kombination führte, im Vergleich zur Standard IVT-RNA, zu einer erhöhten Dichte und Stabilität von Peptid/MHC-Komplexen auf der Zelloberfläche transfizierter DCs und dadurch zu einer verbesserten Stimulation von CD4+ und CD8+ T-Zellen im murinen und humanen System. Mit dem Ziel, die RNA kodierte Antigenform für die Induktion einer verstärkten Antikörperantwort zu modifizieren, wurde im zweiten Teil der Arbeit ein Antigen-IgM Fusionskonstrukt hergestellt und hinsichtlich seiner Eignung als neues Impfstoff-Format untersucht. Die Ausgangshypothese, dass die RNA kodierten Antigen-IgM Fusionsproteine polymerisieren, von transfizierten Zellen sezerniert werden und aufgrund der repetitiven Antigenstruktur im Vergleich mit dem monomeren Antigen zu einer Verstärkung der Antikörperantwort führen, wurde in vitro und in vivo im Mausmodell bestätigt. Die Entwicklung und Evaluierung von Zytokinfusionsproteinen zur selektiven Verstärkung der antigenspezifischen Immunantworten bildeten den dritten Schwerpunkt der vorliegenden Arbeit. Zur weiteren Verstärkung der Antikörperantwort wurde basierend auf den Resultaten aus dem zweiten Teil ein IL2-IgM Fusionskonstrukt hergestellt. Die Ko-Transfektion von Antigen-IgM und IL2-IgM kodierender IVT-RNA führte zu einer signifikant stärkeren Antikörperantwort als die Ko-Transfektion von Antigen-IgM und IL2. Für die Initiierung einer erfolgreichen anti-Tumor-Immunantwort ist das Priming antigenspezifischer T-Zellen essentiell. Um die Effizienz dieses Prozesses zu steigern, wurde ein bifunktionelles IL2-mCD40L Fusionskonstrukt hergestellt und sein Einfluss auf die Effektorfunktion von DCs in vitro und in vivo untersucht. Es wurde gezeigt, dass ein RNA kodiertes IL2-mCD40L Fusionsprotein als genetisches Adjuvanz zu einer Effizienzsteigerung des Priming zytotoxischer T-Zellen führt. Somit wurden in dieser Arbeit durch die Optimierung der Pharmakokinetik, die Modifikation der Antigenform und die Herstellung und Evaluierung von Zytokinfusionskonstrukten als genetische Adjuvantien, RNA-basierte Impfstoffe für eine optimierte Induktion von antigenspezifischen Immunantworten weiter verbessert.
Resumo:
During my PhD,I have been develop an innovative technique to reproduce in vitro the 3D thymic microenvironment, to be used for growth and differentiation of thymocytes, and possible transplantation replacement in conditions of depressed thymic immune regulation. The work has been developed in the laboratory of Tissue Engineering at the University Hospital in Basel, Switzerland, under the tutorship of Prof.Ivan Martin. Since a number of studies have suggested that the 3D structure of the thymic microenvironment might play a key role in regulating the survival and functional competence of thymocytes, I’ve focused my effort on the isolation and purification of the extracellular matrix of the mouse thymus. Specifically, based on the assumption that TEC can favour the differentiation of pre-T lymphocytes, I’ve developed a specific decellularization protocol to obtain the intact, DNA-free extracellular matrix of the adult mouse thymus. Two different protocols satisfied the main characteristics of a decellularized matrix, according to qualitative and quantitative assays. In particular, the quantity of DNA was less than 10% in absolute value, no positive staining for cells was found and the 3D structure and composition of the ECM were maintained. In addition, I was able to prove that the decellularized matrixes were not cytotoxic for the cells themselves, and were able to increase expression of MHC II antigens compared to control cells grown in standard conditions. I was able to prove that TECs grow and proliferate up to ten days on top the decellularized matrix. After a complete characterization of the culture system, these innovative natural scaffolds could be used to improve the standard culture conditions of TEC, to study in vitro the action of different factors on their differentiation genes, and to test the ability of TECs to induce in vitro maturation of seeded T lymphocytes.
Resumo:
Non-invasive molecular-imaging technologies are playing a key role in drug discovery, development and delivery. Positron Emission Tomography (PET) is such a molecular imaging technology and a powerful tool for the observation of various deceases in vivo. However, it is limited by the availability of vectors with high selectivity to the target and radionuclides with a physical half-life which matches the biological half-life of the observed process. The 68Ge/68Ga radionuclide generator makes the PET-nuclide anywhere available without an on-site cyclotron. Besides the perfect availability 68Ga shows well suited nuclide properties for PET, but it has to be co-ordinated by a chelator to introduce it in a radiopharmaceuticals.rnHowever, the physical half-life of 68Ga (67.7 min) might limit the spectrum of clinical applications of 68Ga-labelled radiodiagnostics. Furthermore, 68Ga-labelled analogues of endoradiotherapeuticals of longer biological half-live such as 90Y- or 177Lu-labeled peptides and proteins cannot be used to determine individual radiation dosimetry directly. rnThus, radionuclide generator systems providing positron emitting daughters of extended physical half-life are of renewed interest. In this context, generator-derived positron emitters with longer physical half-life are needed, such as 72As (T½ = 26 h) from the 72Se/72As generator, or 44Sc (T½ = 3.97 h) from the 44Ti/44Sc generator.rnIn this thesis the implementation of radioactive gallium-68 and scandium-44 for molecular imaging and nuclear medical diagnosis, beginning with chemical separation and purification of 44Ti as a radionuclide mother, investigation of pilot generators with different elution mode, building a prototype generator, development and investigation of post-processing of the generator eluate, its concentration and further purification, the labeling chemistry under different conditions, in vitro and in vivo studies of labeled compounds and, finally, in vivo imaging experiments are described.
Resumo:
Seventeen bones (sixteen cadaveric bones and one plastic bone) were used to validate a method for reconstructing a surface model of the proximal femur from 2D X-ray radiographs and a statistical shape model that was constructed from thirty training surface models. Unlike previously introduced validation studies, where surface-based distance errors were used to evaluate the reconstruction accuracy, here we propose to use errors measured based on clinically relevant morphometric parameters. For this purpose, a program was developed to robustly extract those morphometric parameters from the thirty training surface models (training population), from the seventeen surface models reconstructed from X-ray radiographs, and from the seventeen ground truth surface models obtained either by a CT-scan reconstruction method or by a laser-scan reconstruction method. A statistical analysis was then performed to classify the seventeen test bones into two categories: normal cases and outliers. This classification step depends on the measured parameters of the particular test bone. In case all parameters of a test bone were covered by the training population's parameter ranges, this bone is classified as normal bone, otherwise as outlier bone. Our experimental results showed that statistically there was no significant difference between the morphometric parameters extracted from the reconstructed surface models of the normal cases and those extracted from the reconstructed surface models of the outliers. Therefore, our statistical shape model based reconstruction technique can be used to reconstruct not only the surface model of a normal bone but also that of an outlier bone.
Resumo:
As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.
Resumo:
This paper presents a kernel density correlation based nonrigid point set matching method and shows its application in statistical model based 2D/3D reconstruction of a scaled, patient-specific model from an un-calibrated x-ray radiograph. In this method, both the reference point set and the floating point set are first represented using kernel density estimates. A correlation measure between these two kernel density estimates is then optimized to find a displacement field such that the floating point set is moved to the reference point set. Regularizations based on the overall deformation energy and the motion smoothness energy are used to constraint the displacement field for a robust point set matching. Incorporating this non-rigid point set matching method into a statistical model based 2D/3D reconstruction framework, we can reconstruct a scaled, patient-specific model from noisy edge points that are extracted directly from the x-ray radiograph by an edge detector. Our experiment conducted on datasets of two patients and six cadavers demonstrates a mean reconstruction error of 1.9 mm