985 resultados para Fit-body


Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Two more bodies, including a that of child discovered in a tree, were retrieved in the Lockyer Valley at the weekend, reinforcing the grisly complexity of the search for the missing."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this chapter we aim to provide a 'pracademic' view on the reasons why we have boards and why they undertake certain activities. Our approach is based primarily on academic research, hopefully tempered with a real-world understanding of governance issues. We also rely on insights we have gleaned from our own research that primarily relies on observing boards in action.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common finding in brand extension literature is that extension’s favorability is a function of the perceived fit between the parent brand and its extension (Aaker and Keller 1990; Park, Milberg, and Lawson 1991; Volckner and Sattler 2006) that is partially mediated by perceptions of risk (Milberg, Sinn, and Goodstein 2010; Smith and Andrews 1995). In other words, as fit between the parent brand and its extension increases, parent brand beliefs become more readily available, thus increasing consumer certainty and confidence about the new extension, which results in more positive evaluations. On the other hand, as perceived fit decreases, consumer certainty about the parent brand’s ability to introduce the extension is reduced, leading to more negative evaluations. Building on the notion that perceived fit of vertical line extensions is a function of the price/quality distance between parent brand and its extension (Lei, de Ruyter, and Wetzels 2008), traditional brand extension knowledge predicts a directionally consistent impact of perceived fit on evaluations of vertical extensions. Hence, vertical (upscale or downscale) extensions that are placed closer to the parent brand in the price/quality spectrum should lead to higher favorability ratings compared to more distant ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To estimate the burden of disease attributable to excess body weight using the body mass index (BMI), by age and sex, in South Africa in 2000. Design. World Health Organization comparative risk assessment (CRA) methodology was followed. Re-analysis of the 1998 South Africa Demographic and Health Survey data provided mean BMI estimates by age and sex. Populationattributable fractions were calculated and applied to revised burden of disease estimates. Monte Carlo simulation-modelling techniques were used for the uncertainty analysis. Setting. South Africa. Subjects. Adults 30 years of age. Outcome measures. Deaths and disability-adjusted life years (DALYs) from ischaemic heart disease, ischaemic stroke, hypertensive disease, osteoarthritis, type 2 diabetes mellitus, and selected cancers. Results. Overall, 87% of type 2 diabetes, 68% of hypertensive disease, 61% of endometrial cancer, 45% of ischaemic stroke, 38% of ischaemic heart disease, 31% of kidney cancer, 24% of osteoarthritis, 17% of colon cancer, and 13% of postmenopausal breast cancer were attributable to a BMI 21 kg/m2. Excess body weight is estimated to have caused 36 504 deaths (95% uncertainty interval 31 018 - 38 637) or 7% (95% uncertainty interval 6.0 - 7.4%) of all deaths in 2000, and 462 338 DALYs (95% uncertainty interval 396 512 - 478 847) or 2.9% of all DALYs (95% uncertainty interval 2.4 - 3.0%). The burden in females was approximately double that in males. Conclusions. This study shows the importance of recognising excess body weight as a major risk to health, particularly among females, highlighting the need to develop, implement and evaluate comprehensive interventions to achieve lasting change in the determinants and impact of excess body weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of the tibia. An optimal nail design should both facilitate insertion and anatomically fit the bone geometry at its final position in order to reduce the risk of stress fractures and malalignments. Due to the nonexistence of suitable commercial software, we developed a software tool for the automated fit assessment of nail designs. Furthermore, we demonstrated that an optimised nail, which fits better at the final position, is also easier to insert. Three-dimensional models of two nail designs and 20 tibiae were used. The fitting was quantified in terms of surface area, maximum distance, sum of surface areas and sum of maximum distances by which the nail was protruding into the cortex. The software was programmed to insert the nail into the bone model and to quantify the fit at defined increment levels. On average, the misfit during the insertion in terms of the four fitting parameters was smaller for the Expert Tibial Nail Proximal bend (476.3 mm2, 1.5 mm, 2029.8 mm2, 6.5 mm) than the Expert Tibial Nail (736.7 mm2, 2.2 mm, 2491.4 mm2, 8.0 mm). The differences were statistically significant (p ≤ 0.05). The software could be used by nail implant manufacturers for the purpose of implant design validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of tibia. Selection of the correct nail insertion point is important for axial alignment of bone fragments and to avoid iatrogenic fractures. However, the standard entry point (SEP) may not always optimise the bone-nail fit due to geometric variations of bones. This study aimed to investigate the optimal entry for a given bone-nail pair using the fit quantification software tool previously developed by the authors. The misfit was quantified for 20 bones with two nail designs (ETN and ETN-Proximal Bend) related to the SEP and 5 entry points which were 5 mm and 10 mm away from the SEP. The SEP was the optimal entry point for 50% of the bones used. For the remaining bones, the optimal entry point was located 5 mm away from the SEP, which improved the overall fit by 40% on average. However, entry points 10 mm away from the SEP doubled the misfit. The optimised bone-nail fit can be achieved through the SEP and within the range of a 5 mm radius, except posteriorly. The study results suggest that the optimal entry point should be selected by considering the fit during insertion and not only at the final position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last five years the Safety Institute of Australia Limited (SIA) has developed and implemented a number of strategies to gain professional recognition for the ‘generalist occupational health and safety (OHS) professional’ in Australia and internationally. Despite a considerable amount of work by the SIA aimed at gaining professional status, there does not appear to have been any published debate or reflection about how the drive for professionalism (the ‘professional project’) will contribute to the prevention of occupational disease and injury. Professionalisation has been promoted as a sign of maturity for the SIA and as an unquestionably good outcome, as it has been assumed that professionalisation will provide unmitigated benefits for workplace health and safety. The aim of this paper is to critically reflect on the processes of professionalisation (the professional project) and discuss the ways in which this project may shape the field of occupational health and safety.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Through a consideration of audience experience of embodiment in contemporary dance performance, this project used kinesthetic empathy as a theoretical construct to inform choreographic decision-making. The research outcome challenged the traditional performer/audience relationship through an interactive dance performance work entitled Planets. This acted as a platform that allowed both audience and performer to collaboratively listen to, process and form movement in a shared kinesthetic state. This connection was enabled through the distribution of interactive art objects, which responded to the shifting proximity between performer and audience. The performance was thus experienced through following a shared goal as instigated by the interactive technology. Through practice-led research, knowledge from kinesthetic empathy, embodied cognition and the mirror neuron system were used to develop the project’s aim in encouraging interactive audiences to engage in movement. This aim influenced studio explorations of movement through an enquiry into the kinesthetic self in dance. Investigations used movement quality, tension, mobility and acceleration to access a familiar movement vocabulary appropriate for a broad interactive audience. This informed the role of the researcher as performer. Planets was developed as a collaborative project between Michael Smith and interactive visual designer Andy Bates and performed over three nights at the Ars Electronica Festival 2014 in Linz, Austria. Supported by documented footage from Planets and audience responses to the performances, this paper draws together the theoretical underpinnings behind the development of the work and includes the experiential perspective of the performer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis undertakes an empirical investigation to identify factors that influence the decision to undertake weight loss behaviour using the nationally representative HILDA dataset. Although many factors influenced the decision, the findings suggested that body weight satisfaction was the greatest determinant of weight loss dieting. This thesis therefore conducted a further empirical study to analyse the determinants of body weight satisfaction. A rank-hypothesis was found to better predict variation in body weight satisfaction levels than the absolute value of the individual's Body Mass Index (BMI) or the relative-norm hypothesis, which are commonly reported in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This video was prepared as a teaching resource for CARRS-Q's Under the Limit Drink Driving Rehabilitation Program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of whole-body imaging at single-cell resolution enables system-level approaches to studying cellular circuits in organisms. Previous clearing methods focused on homogenizing mismatched refractive indices of individual tissues, enabling reductions in opacity but falling short of achieving transparency. Here, we show that an aminoalcohol decolorizes blood by efficiently eluting the heme chromophore from hemoglobin. Direct transcardial perfusion of an aminoalcohol-containing cocktail that we previously termed CUBIC coupled with a 10 day to 2 week clearing protocol decolorized and rendered nearly transparent almost all organs of adult mice as well as the entire body of infant and adult mice. This CUBIC-perfusion protocol enables rapid whole-body and whole-organ imaging at single-cell resolution by using light-sheet fluorescent microscopy. The CUBIC protocol is also applicable to 3D pathology, anatomy, and immunohistochemistry of various organs. These results suggest that whole-body imaging of colorless tissues at high resolution will contribute to organism-level systems biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anatomically pre-contoured fracture fixation plates are a treatment option for bone fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. However, recent studies showed that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. Therefore, the plates have to be manually fitted and deformed by surgeons to fit each patient optimally. The process is time-intensive and labor-intensive, and could lead to adverse clinical implications such as wound infection or plate failure. This paper proposes a new iterative method to simulate the patient-specific deformation of an optimally fitting plate for pre-operative planning purposes. We further demonstrate the validation of the method through a case study. The proposed method involves the integration of four commercially available software tools, Matlab, Rapidform2006, SolidWorks, and ANSYS, each performing specific tasks to obtain a plate shape that fits optimally for an individual tibia and is mechanically safe. A typical challenge when crossing multiple platforms is to ensure correct data transfer. We present an example of the implementation of the proposed method to demonstrate successful data transfer between the four platforms and the feasibility of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation programs of bone-anchorage prostheses relying either on the OPRA (Integrum, Sweden) or the ILP (Orthodynamics, Germany) fixation involve some forms of static load bearing exercises (LBE). So far, most of biomechanical studies of these static LBEs focused on the direct measurements of the actual forces and moments applied on the OPRA fixation of individuals with transfemoral amputation (TFA). To date, the proof-of-concept of an apparatus to conduct these kinetic measurements has been presented, along with some preliminary data. The understanding of the kinetic data is essential to improve rehabilitation programs as well as the design of upcoming loading frames. However, kinetic information alone is difficult to interpret without concomitant kinematic data. The purpose of this preliminary study was to introduce a qualitative analysis describing the different body postures during LBE for a group of TFAs.