979 resultados para vibrational normal mode analysis maple water


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is concerned with a modeling method that can be used for an experimental identification of a dynamic system. More specifically, an equivalent lumped element system is presented to represent in a unique and exact manner a complete proportional-derivative (PD) controlled servo positioning system having a flexible manipulator. The impedance and mobility approach is used to transform the P and D control gains to an electrical spring and an electrical damper, respectively. The impedance model method is used to transform the flexible manipulator to a coupled system between a single contact mass at the driving position and a series of noncontact masses each of which is connected to the contact mass via a resilient member. This method is applicable whenever the driving point response of such a manipulator is available. Experimental work is presented to support the theory developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To compare three different designs for measuring the bond strength between Y-TZP ceramic and a composite material, before and after ceramic surface treatment, evaluating the influence of the size of the adhesive interface for each design.Methods. 'Macro'tensile, microtensile, 'macro'shear, microshear, 'macro'push-out, and micropush-out tests were carried out. Two Y-TZP surface treatments were evaluated: silanization (sil) and tribochemical silica coating (30 mu m silica-modified Al2O3 particles + silanization) (TBS). Failure mode analysis of tested samples was also performed. Results. Both the surface treatment and the size of the bonded interface significantly affected the results (p = 0.00). Regardless of the type of surface treatment, the microtensile and microshear tests had higher values than their equivalent "macro" tests. However, the push-out test showed the highest values for the "macro" test. The tensile tests showed the greatest variability in results. The tribochemical silica coating method significantly increased bond strength for all tests.Significance. Different test designs can change the outcome for Y-TZP/cement interfaces, in terms of mean values and reliability (variability). The 'micro'tests expressed higher bond strengths than their equivalent 'macro'tests, with the exception of the push-out test (macro > micro). (C) 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We measured alcohol levels by the Cordebard method in 148 CSF samples from individuals who had abstained from alcohol for at least 7 days prior to the beginning of the study. Each blood sample was accompanied by a CSF sample from the same patient. CSF samples found to be normal after analysis were used as controls. Mean alcohol concentration in blood did not differ significantly between the control group and the groups with altered CSF. The group with altered CSF had statistically higher alcohol levels in CSF than in blood. CSF lactate, glucose and protein levels were not correlated with alcohol level. The results suggest the presence of endogenous alcohol in the CSF, with levels increasing in the presence of pathological processes involving the nervous system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this manuscript, an automatic setup for screening of microcystins in surface waters by employing photometric detection is described. Microcystins are toxins delivered by cyanobacteria within an aquatic environment, which have been considered strongly poisonous for humans. For that reason, the World Health Organization (WHO) has proposed a provisional guideline value for drinking water of 1 mu g L-1. In this work, we developed an automated equipment setup, which allows the screening of water for concentration of microcystins below 0.1 mu g V. The photometric method was based on the enzyme-linked immunosorbent assay (ELISA) and the analytical signal was monitored at 458 nm using a homemade LED-based photometer. The proposed system was employed for the detection of microcystins in rivers and lakes waters. Accuracy was assessed by processing samples using a reference method and applying the paired t-test between results. No significant difference at the 95% confidence level was observed. Other useful features including a linear response ranging from 0.05 up to 2.00 mu g L-1 (R-2 =0.999) and a detection limit of 0.03 mu g L-1 microcystins were achieved. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La tecnica di ozonolisi viene applicata ai fanghi biologici derivanti da impianti di depurazione acque reflue urbane, e consiste nell'ottenere, grazie all'ozono, una minor massa fangosa da smaltire e una miglior trattabilità del fango residue. In questo elaborato si prendono in esame le sperimentazioni effettuate a Marina di Ravenna e si estraggono le prime conclusioni gestionali, economiche e ambientali sull'applicabilità del metodo a questo tipo di fango.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The surgical treatment of dysfunctional hips is a severe condition for the patient and a costly therapy for the public health. Hip resurfacing techniques seem to hold the promise of various advantages over traditional THR, with particular attention to young and active patients. Although the lesson provided in the past by many branches of engineering is that success in designing competitive products can be achieved only by predicting the possible scenario of failure, to date the understanding of the implant quality is poorly pre-clinically addressed. Thus revision is the only delayed and reliable end point for assessment. The aim of the present work was to model the musculoskeletal system so as to develop a protocol for predicting failure of hip resurfacing prosthesis. Methods. Preliminary studies validated the technique for the generation of subject specific finite element (FE) models of long bones from Computed Thomography data. The proposed protocol consisted in the numerical analysis of the prosthesis biomechanics by deterministic and statistic studies so as to assess the risk of biomechanical failure on the different operative conditions the implant might face in a population of interest during various activities of daily living. Physiological conditions were defined including the variability of the anatomy, bone densitometry, surgery uncertainties and published boundary conditions at the hip. The protocol was tested by analysing a successful design on the market and a new prototype of a resurfacing prosthesis. Results. The intrinsic accuracy of models on bone stress predictions (RMSE < 10%) was aligned to the current state of the art in this field. The accuracy of prediction on the bone-prosthesis contact mechanics was also excellent (< 0.001 mm). The sensitivity of models prediction to uncertainties on modelling parameter was found below 8.4%. The analysis of the successful design resulted in a very good agreement with published retrospective studies. The geometry optimisation of the new prototype lead to a final design with a low risk of failure. The statistical analysis confirmed the minimal risk of the optimised design over the entire population of interest. The performances of the optimised design showed a significant improvement with respect to the first prototype (+35%). Limitations. On the authors opinion the major limitation of this study is on boundary conditions. The muscular forces and the hip joint reaction were derived from the few data available in the literature, which can be considered significant but hardly representative of the entire variability of boundary conditions the implant might face over the patients population. This moved the focus of the research on modelling the musculoskeletal system; the ongoing activity is to develop subject-specific musculoskeletal models of the lower limb from medical images. Conclusions. The developed protocol was able to accurately predict known clinical outcomes when applied to a well-established device and, to support the design optimisation phase providing important information on critical characteristics of the patients when applied to a new prosthesis. The presented approach does have a relevant generality that would allow the extension of the protocol to a large set of orthopaedic scenarios with minor changes. Hence, a failure mode analysis criterion can be considered a suitable tool in developing new orthopaedic devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: The dimension stone qualification through the use of non-destructive tests (NDT) is a relevant research topic for the industrial characterisation of finite products, because the competition of low-costs products can be sustained by an offer of highqualification and a top-guarantee products. The synthesis of potentialities offered by the NDT is the qualification and guarantee similar to the well known agro-industrial PDO, Protected Denomination of Origin. In fact it is possible to guarantee both, the origin and the quality of each stone product element, even through a Factory Production Control on line. A specific disciplinary is needed. A research developed at DICMA-Univ. Bologna in the frame of the “OSMATER” INTERREG project, allowed identifying good correlations between destructive and non-destructive tests for some types of materials from Verbano-Cusio-Ossola region. For example non conventional ultrasonic tests, image analysis parameters, water absorption and other measurements showed to be well correlated with the bending resistance, by relationships varying for each product. In conclusion it has been demonstrated that a nondestructive approach allows reaching several goals, among the most important: 1) the identification of materials; 2) the selection of products; 3) the substitution of DT by NDT. Now it is necessary to move from a research phase to the industrial implementation, as well as to develop new ND technologies focused on specific aims.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been demonstrated that iodine does have an important influence on atmospheric chemistry, especially the formation of new particles and the enrichment of iodine in marine aerosols. It was pointed out that the most probable chemical species involved in the production or growth of these particles are iodine oxides, produced photochemically from biogenic halocarbon emissions and/or iodine emission from the sea surface. However, the iodine chemistry from gaseous to particulate phase in the coastal atmosphere and the chemical nature of the condensing iodine species are still not understood. A Tenax / Carbotrap adsorption sampling technique and a thermo-desorption / cryo-trap / GC-MS system has been further developed and improved for the volatile organic iodine species in the gas phase. Several iodo-hydrocarbons such as CH3I, C2H5I, CH2ICl, CH2IBr and CH2I2 etc., have been measured in samples from a calibration test gas source (standards), real air samples and samples from seaweeds / macro-algae emission experiments. A denuder sampling technique has been developed to characterise potential precursor compounds of coastal particle formation processes, such as molecular iodine in the gas phase. Starch, TMAH (TetraMethylAmmonium Hydroxide) and TBAH (TetraButylAmmonium Hydroxide) coated denuders were tested for their efficiencies to collect I2 at the inner surface, followed by a TMAH extraction and ICP/MS determination, adding tellurium as an internal standard. The developed method has been proved to be an effective, accurate and suitable process for I2 measurement in the field, with the estimated detection limit of ~0.10 ng∙L-1 for a sampling volume of 15 L. An H2O/TMAH-Extraction-ICP/MS method has been developed for the accurate and sensitive determination of iodine species in tropospheric aerosol particles. The particle samples were collected on cellulose-nitrate filters using conventional filter holders or on cellulose nitrate/tedlar-foils using a 5-stage Berner impactor for size-segregated particle analysis. The water soluble species as IO3- and I- were separated by anion exchanging process after water extraction. Non-water soluble species including iodine oxide and organic iodine were digested and extracted by TMAH. Afterwards the triple samples were analysed by ICP/MS. The detection limit for particulate iodine was determined to be 0.10~0.20 ng•m-3 for sampling volumes of 40~100 m3. The developed methods have been used in two field measurements in May 2002 and September 2003, at and around the Mace Head Atmospheric Research Station (MHARS) located at the west coast of Ireland. Elemental iodine as a precursor of the iodine chemistry in the coastal atmosphere, was determined in the gas phase at a seaweed hot-spot around the MHARS, showing I2 concentrations were in the range of 0~1.6 ng∙L-1 and indicating a positive correlation with the ozone concentration. A seaweed-chamber experiment performed at the field measurement station showed that the I2 emission rate from macro-algae was in the range of 0.019~0.022 ng•min-1•kg-1. During these experiments, nanometer-particle concentrations were obtained from the Scanning Mobility Particle Sizer (SMPS) measurements. Particle number concentrations were found to have a linear correlation with elemental iodine in the gas phase of the seaweeds chamber, showing that gaseous I2 is one of the important precursors of the new particle formation in the coastal atmosphere. Iodine contents in the particle phase were measured in both field campaigns at and around the field measurement station. Total iodine concentrations were found to be in the range of 1.0 ~ 21.0 ng∙m-3 in the PM2.5 samples. A significant correlation between the total iodine concentrations and the nanometer-particle number concentrations was observed. The particulate iodine species analysis indicated that iodide contents are usually higher than those of iodate in all samples, with ratios in the range of 2~5:1. It is possible that those water soluble iodine species are transferred through the sea-air interface into the particle phase. The ratio of water soluble (iodate + iodide) and non-water soluble species (probably iodine oxide and organic iodine compounds) was observed to be in the range of 1:1 to 1:2. It appears that higher concentrated non-water soluble species, as the products of the photolysis from the gas phase into the particle phase, can be obtained in those samples while the nucleation events occur. That supports the idea that iodine chemistry in the coastal boundary layer is linked with new particle formation events. Furthermore, artificial aerosol particles were formed from gaseous iodine sources (e.g. CH2I2) using a laboratory reaction-chamber experiment, in which the reaction constant of the CH2I2 photolysis was calculated to be based upon the first order reaction kinetic. The end products of iodine chemistry in the particle phase were identified and quantified.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde die zeitaufgelöste Photoemissions Elektronenmikroskopie (TR-PEEM) für die in-situ Untersuchung ultraschneller dynamischer Prozesse in dünnen mikrostrukturierten magnetischen Schichten während eines rasch verändernden externen Magnetfelds entwickelt. Das Experiment basiert auf der Nutzung des XMCD-Kontrasts (X-ray magnetic circular dichroism) mit Hilfe des zirkularpolarisierten Lichts von Synchrotronstrahlungsquellen (Elektronenspeicherringen BESSY II (Berlin) und ESRF (Grenoble)) für die dynamische Darstellung der magnetischen Domänen während ultraschneller Magnetisierungsvorgänge. Die hier entwickelte Methode wurde als erfolgreiche Kombination aus einer hohen Orts- und Zeitauflösung (weniger als 55 nm bzw. 15 ps) realisiert. Mit der hier beschriebenen Methode konnte nachgewiesen werden, dass die Magnetisierungsdynamik in großen Permalloy-Mikrostrukturen (40 µm x 80 µm und 20 µm x 80 µm, 40 nm dick) durch inkohärente Drehung der Magnetisierung und mit der Bildung von zeitlich abhängigen Übergangsdomänen einher geht, die den Ummagnetisierungsvorgang blockieren. Es wurden neue markante Differenzen zwischen der magnetischen Response einer vorgegebenen Dünnfilm-Mikrostruktur auf ein gepulstes externes Magnetfeld im Vergleich zu dem quasi-statischen Fall gefunden. Dies betrifft die Erscheinung von transienten raumzeitlichen Domänenmustern und besonderen Detailstrukturen in diesen Mustern, welche im quasi-statischen Fall nicht auftreten. Es wurden Beispiele solcher Domänenmuster in Permalloy-Mikrostrukturen verschiedener Formen und Größen untersucht und diskutiert. Insbesondere wurde die schnelle Verbreiterung von Domänenwänden infolge des präzessionalen Magnetisierungsvorgangs, die Ausbildung von transienten Domänenwänden und transienten Vortizes sowie die Erscheinung einer gestreiften Domänenphase aufgrund der inkohärenten Drehung der Magnetisierung diskutiert. Ferner wurde die Methode für die Untersuchung von stehenden Spinwellen auf ultradünnen (16 µm x 32 µm groß und 10 nm dick) Permalloy-Mikrostrukturen herangezogen. In einer zum periodischen Anregungsfeld senkrecht orientierten rechteckigen Mikrostruktur wurde ein induziertes magnetisches Moment gefunden. Dieses Phänomen wurde als „selbstfangende“ Spinwellenmode interpretiert. Es wurde gezeigt, dass sich eine erzwungene Normalmode durch Verschiebung einer 180°-Néelwand stabilisiert. Wird das System knapp unterhalb seiner Resonanzfrequenz angeregt, passt sich die Magnetisierungsverteilung derart an, dass ein möglichst großer Teil der durch das Anregungsfeld eingebrachten Energie im System verbleibt. Über einem bestimmten Grenzwert verursacht die Spinwellenmode nahe der Resonanzfrequenz eine effektive Kraft senkrecht zur 180°-Néel-Wand. Diese entsteht im Zentrum der Mikrostruktur und wird durch die streufeldinduzierte Kraft kompensiert. Als zusätzliche Möglichkeit wurden die Streufelder von magnetischen Mikrostrukturen während der dynamischen Prozesse quantitativ bestimmt und das genaue zeitliche Profil des Streufelds untersucht. Es wurde gezeigt, dass das zeitaufgelöste Photoemissions Elektronenmikroskop als ultraschnelles oberflächensensitives Magnetometer eingesetzt werden kann.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die FT-Rheologie wird zur Unterscheidung verschiedener Kamm-Topologien in Polystyrollösungen und –schmelzen angewendet. Die Polystyrole werden in Abhängigkeit der Deborahzahl De unter LAOS-Bedingungen vermessen. Die Meßergebnisse zeigen, daß der Schritt von wohldefinierten Systemen (lineare Ketten, Sterne) zu solchen mit statistischer Verteilung wie in Kämmen zu großen Veränderungen sowohl im linearen als auch im nichtlinearen Bereich der rheologischen Messungen führt. Sowohl die Masterkurven als auch die Intenstiäten I3/1 und Phasen Phi3 der Nichtlinearitäten der einzelnen Proben weisen jeweils deutliche Unterschiede untereinander auf. Diese sind durch die bisherigen Ergebnisse noch nicht vollständig mit topologischen Merkmalen in Verbindung zu bringen. Die Messungen wurden mit dem von McLeish eingeführten Pom-pom Modell und daraus weiterentwickelten double convected-Pom-pom Modell (DCPP) simuliert und lieferten gute Übereinstimmung sowie auch Vorhersagen über den experimentell nicht mehr zugänglichen Bereich. Zur Untersuchung des Einflusses von mechanischer Scherung auf die lokale, molekulare Dynamik wird das LAOS-Experiment in situ mit dielektrischer Spektroskopie kombiniert. Dazu wurde eine Apparatur entwickelt, die das hochsensitive ARES-Rheometer mit dem hochauflösenden dielektrischen ALPHA-Analyzer verbindet. Mit dieser Apparatur wurde das Typ-A Polymer 1,4-cis-Polyisopren, mit einem Dipolmoment entlang des Rückgrats, bei oszillatorischer Scherung unter gleichzeitiger Aufnahme eines dielektrischen Spektrums vermessen. Es konnte gezeigt werden, daß die oszillatorische Verscherung weder die charakteristische Relaxationszeit noch die Form des Normal Mode Peaks beeinflußt, wohl aber die dielektrische Stärke Delta epsilon. Diese entspricht der Fläche unter dem e“-Peak und kann mit einer Debye- und einer Cole/Davidson-Funktion angepasst werden. Die Abnahme der dielektrischen Stärke mit zunehmender Scheramplitude kann mit der Orientierungsverteilung der End-zu-End-Vektoren in der Probe erklärt werden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diese Arbeit befasst sich mit den optischen Resonanzen metallischer Nanopartikel im Abstand weniger Nanometer von einer metallischen Grenzfläche. Die elektromagnetische Wechselwirkung dieser „Kugel-vor-Fläche“ Geometrie ruft interessante optische Phänomene hervor. Sie erzeugt eine spezielle elektromagnetische Eigenmode, auch Spaltmode genannt, die im Wesentlichen auf den Nanospalt zwi-schen Kugel und Oberfläche lokalisiert ist. In der quasistatischen Näherung hängt die Resonanzposition nur vom Material, der Umgebung, dem Film-Kugel Abstand und dem Kugelradius selbst ab. Theoretische Berechnungen sagen für diese Region unter Resonanzbedingungen eine große Verstärkung des elektro-magnetischen Feldes voraus. rnUm die optischen Eigenschaften dieser Systeme zu untersuchen, wurde ein effizienter plasmonenver-mittelnder Dunkelfeldmodus für die konfokale Rastermikroskopie durch dünne Metallfilme entwickelt, der die Verstärkung durch Oberflächenplasmonen sowohl im Anregungs- als auch Emissionsprozess ausnutzt. Dadurch sind hochwertige Dunkelfeldaufnahmen durch die Metallfilme der Kugel-vor-Fläche Systeme garantiert, und die Spektroskopie einzelner Resonatoren wird erleichtert. Die optischen Untersuchungen werden durch eine Kombination von Rasterkraft- und Rasterelektronenmikroskopie vervollständigt, so dass die Form und Größe der untersuchten Resonatoren in allen drei Dimensionen bestimmt und mit den optischen Resonanzen korreliert werden können. Die Leistungsfähigkeit des neu entwickelten Modus wird für ein Referenzsystem aus Polystyrol-Kugeln auf einem Goldfilm demonstriert. Hierbei zeigen Partikel gleicher Größe auch die erwartete identische Resonanz.rnFür ein aus Gold bestehendes Kugel-vor-Fläche System, bei dem der Spalt durch eine selbstorganisierte Monolage von 2-Aminoethanthiol erzeugt wird, werden die Resonanzen von Goldpartikeln, die durch Reduktion mit Chlorgoldsäure erzeugt wurden, mit denen von idealen Goldkugeln verglichen. Diese ent-stehen aus den herkömmlichen Goldpartikeln durch zusätzliche Bestrahlung mit einem Pikosekunden Nd:Yag Laser. Bei den unbestrahlten Partikeln mit ihrer Unzahl an verschiedenen Formen zeigen nur ein Drittel der untersuchten Resonatoren ein Verhalten, das von der Theorie vorhergesagt wird, ohne das dies mit ihrer Form oder Größe korrelieren würde. Im Fall der bestrahlten Goldkugeln tritt eine spürbare Verbesserung ein, bei dem alle Resonatoren mit den theoretischen Rechnungen übereinstimmen. Eine Änderung der Oberflächenrauheit des Films zeigt hingegen keinen Einfluß auf die Resonanzen. Obwohl durch die Kombination von Goldkugeln und sehr glatten Metallfilmen eine sehr definierte Probengeometrie geschaffen wurde, sind die experimentell bestimmten Linienbreiten der Resonanzen immer noch wesentlich größer als die berechneten. Die Streuung der Daten, selbst für diese Proben, deutet auf weitere Faktoren hin, die die Spaltmoden beeinflußen, wie z.B. die genaue Form des Spalts. rnDie mit den Nanospalten verbundenen hohen Feldverstärkungen werden untersucht, indem ein mit Farbstoff beladenes Polyphenylen-Dendrimer in den Spalt eines aus Silber bestehenden Kugel-vor-Fläche Systems gebracht wird. Das Dendrimer in der Schale besteht lediglich aus Phenyl-Phenyl Bindungen und garantiert durch die damit einhergende Starrheit des Moleküls eine überragende Formstabiliät, ohne gleichzeitig optisch aktiv zu sein. Die 16 Dithiolan Endgruppen sorgen gleichzeitig für die notwendige Affinität zum Silber. Dadurch kann der im Inneren befindliche Farbstoff mit einer Präzision von wenigen Nanometern im Spalt zwischen den Metallstrukturen platziert werden. Der gewählte Perylen Farbstoff zeichnet sich wiederum durch hohe Photostabilität und Fluoreszenz-Quantenausbeute aus. Für alle untersuchten Partikel wird ein starkes Fluoreszenzsignal gefunden, das mindestens 1000-mal stärker ist, als das des mit Farbstoff überzogenen Metallfilms. Das Profil des Fluoreszenz-Anregungsspektrums variiert zwischen den Partikeln und zeigt im Vergleich zum freien Farbstoff eine zusätzliche Emission bei höheren Frequenzen, was in der Literatur als „hot luminescence“ bezeichnet wird. Bei der Untersuchung des Streuverhaltens der Resonatoren können wieder zwei unterschiedliche Arten von Resonatoren un-terschieden werden. Es gibt zunächst die Fälle, die bis auf die beschriebene Linienverbreiterung mit einer idealen Kugel-vor-Fläche Geometrie übereinstimmen und dann andere, die davon stark abweichen. Die Veränderungen der Fluoreszenz-Anregungsspektren für den gebundenen Farbstoffs weisen auf physikalische Mechanismen hin, die bei diesen kleinen Metall/Farbstoff Abständen eine Rolle spielen und die über eine einfache wellenlängenabhängige Verstärkung hinausgehen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined spectroscopic and ab initio theoretical study of the doubly hydrogen-bonded complex of 2-pyridone (2PY) with NH3 has been performed. The S-1 <- S-0 spectrum extends up to approximate to 1200 cm(-1) above the 0(0)(0) band, close to twice the range observed for 2PY. The S-1 state nonradiative decay for vibrations above approximate to 300 cm(-1) in the NH3 complex is dramatically slowed down relative to bare 2PY. Also, the Delta v=2,4,... overtone bands of the v(1)' and v(2)' out-of-plane vibrations that dominate the low-energy spectral region of 2PY are much weaker or missing for 2PY center dot NH3, which implies that the bridging (2PY)NH center dot center dot center dot NH3 and H2NH center dot center dot center dot O=C H-bonds clamp the 2PY at a planar geometry in the S-1 state. The mass-resolved UV vibronic spectra of jet-cooled 2PY center dot NH3 and its H/D mixed isotopomers are measured using two-color resonant two-photon ionization spectroscopy. The S-0 and S-1 equilibrium structures and normal-mode frequencies are calculated by density functional (B3LYP) and correlated ab initio methods (MP2 and approximate second-order coupled-cluster, CC2). The S-1 <- S-0 vibronic assignments are based on configuration interaction singles (CIS) and CC2 calculations. A doubly H-bonded bridged structure of C-S symmetry is predicted, in agreement with that of Held and Pratt [J. Am. Chem. Soc. 1993, 115, 9718]. While the B3LYP and MP2 calculated rotational constants are in very good agreement with experiment, the calculated H2NH center dot center dot center dot O=C H-bond distance is approximate to 0.7 angstrom shorter than that derived by Held and Pratt. On the other hand, this underlines their observation that ammonia can act as a strong H-bond donor when built into an H-bonded bridge. The CC2 calculations predict the H2NH center dot center dot center dot O distance to increase by 0.2 angstrom upon S-1 <- S-0 electronic excitation, while the (2PY)NH center dot center dot center dot NH3 H-bond remains nearly unchanged. Thus, the expansion of the doubly H-bonded bridge in the excited state is asymmetric and almost wholly due to the weakening of the interaction of ammonia with the keto acceptor group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the operation of optical isolators based on magneto-optics waveguide arrays beyond the coupled mode analysis. Semi-vectorial beam propagation simulations demonstrate that evanescent tail coupling and the effects of radiation are responsible for degrading the device’s performance. Our analysis suggests that these effects can be mitigated when the array size is scaled up. In addition, we propose the use of radiation blockers in order to offset some of these effects, and we show that they provide a dramatic improvement in performance. Finally, we also study the robustness of the system with respect to fabrication tolerances using the coupled mode theory. We show that small, random variations in the system’s parameters tend to average out as the number of optical guiding channels increases.