848 resultados para ultrassonografia ocular
Resumo:
We present 6 patients with ocular involvement due to paracoccidioidomycosis. All cases were confirmed by the finding of Paracoccidioides brasiliensis in histopathological or direct mycologic examination of material from the lesion in the eyelid or conjunctiva. In two cases the bulbar conjunctiva was also involved, in another the cornea, and still another patient developed endophthalmitis. The presence of this mutilating disease which may lead to blindness should be suspected when chronic blepharitis or palpebral ulcerated papular lesions are detected in patients from endemic areas of paracoccidioidomycosis. This etiology should also be suspected in patients with anterior and posterior uveitis after discarding the most frequent causes of this condition. © 1988 Kluwer Academic Publishers.
Resumo:
Purpose: To study the effects of two drugs (captopril and propranolol) used in the treatment of systemic hypertension, on the intraocular pressure (IOP) of anesthetized dogs. Methods: 24 dogs, divided into 3 groups of 8 each. In the first group, 1.5 mg/kg IV of captopril (an angiotensin converting enzyme inhibitor) was administered. In the second group, 1.5 mg/kg IV of propranolol (a beta-blocker) was administered. The third group was the control. IOP and blood pressure (BP) were measured by manometry. The perfusion pressure was calculated by the difference between BP and IOP (BP-IOP). The parameters were studied at 6 moments (0, 10, 30, 60, 90 and 120 minutes). Results: There was significant reduction of IOP (p<0.05) with captopril and propranolol, without difference between the drugs. With captopril the BP and PP decreased markedly at 10 and 30 minutes. With propranolol there was no reduction of BP or PP. Conclusions: Captopril and propranolol reduced IOP. However, the marked reduction of BP, and consequently of PP caused by captopril may be undesirable for irrigation of the optic nerve.
Resumo:
The ocular losses are embarrassing to the bearer because they commit the face which has the essential organs for the human relationship. The present study shows the multidiscipline interaction in the treatment of a child who lost his left eye victim of a fire gun and needed an ocular plastic surgery for a correct prosthesis insertion. The ocular prosthesis fills in the ocular cavity simulating the facial growth and restoring its symmetry. Therefore, there are aesthetics, anatomic and physiological improvement on the child's face that allows her to be reinstated in society without being discriminated for her differences. © 2005 Elsevier Ltd. All rights reserved.
Resumo:
The patient with anophthalmia may present feelings of inferiority and rejection. Knowing his/her needs and expectations contribute to a better technical intervention. Purpose: To elaborate a questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis. Methods: An exploratory research was used to elaborate the questionnaire, by means of a guided interview followed by writing down what was said by the interviewees, who were adult patients of the Bucco-Maxillo-Facial Prosthesis Center of FOSJC - UNESP. The guided interview was made up of 14 items directly related to the future outline of the profile. Each item of the interview resulted in questions of the questionnaire, which was pretested twice before reaching its final version. Results: The patients reported, in the exploratory research, unpleasant feelings with the loss of the eye; relationship shyness; expectations regarding surgery and prosthesis use; a wish to receive explanations and to hold their opinion about the treatment. The questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis is, therefore, made of 43 questions divided into 5 blocks in order to aid the comprehension of the inquired aspects and to facilitate both the computation of data and discussion, and also to improve the selection of questions according to the objective of the researcher or professional. Conclusions: It was concluded that the questionnaire was viable, can be used in full or by selecting blocks and provide a panorama of the patient's history related to the problem he/she faces, from the loss of the ocular globe to the confection of the prosthesis.
Resumo:
The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05). All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging.
Resumo:
Purpose: The aim of this study was to evaluate the roughness of colorless ocular button and four brands of colorless acrylic resins designed to fabricate ocular prosthesis as a function of weathering (1008 h) and different thickness (1 and 3.5 mm). Materials and methods: One-hundred-and-twenty specimens were fabricated and distributed in 12 groups. The analysis was carried out by means of digital roughness meter. Results: Data were analyzed statistically by ANOVA and Tukey test at 1% significance. The results showed that there was no statistically significant difference after the weathering period. Both the Vipi Cril acrylic resin with 3.5 mm in thickness and ocular button with 1 mm in thickness presented the lowest roughness values (0.12. Ra). Conclusion: The roughness of the acrylic resins and the ocular button was not affect by the weathering of 1008 h. However, the thickness of the specimens proved to have a major influence on roughness property. © 2010.
Resumo:
Until recently, ultrasonography was not considered one of the prevailing imaging methods for thoracic evaluation due to its limitations in evaluating lesions located below thoracic gas collections in individuals with normal lung tissue as well as in those with pneumothorax. Nevertheless, ultrasound has an advantage over other imaging techniques. It allows not only differentiating pleural from pulmonary lesions, but also identifying and assessing peripheral pulmonary lesions. Thus, thoracic ultrasound has become more popular in Veterinary Medicine as an ancillary method in the diagnosis and treatment of several diseases of the thoracic cavity, especially in emergency settings. This review aims at providing information on the main alterations found in the chest wall, mediastinum, pleura, lung and diaphragm by means of ultrasonography.
Resumo:
PURPOSE: To compare the diagnostic accuracy of sonohysterography (HSN) and conventional transvaginal ultrasound (USG) in assessing the uterine cavity of infertile women candidate to assisted reproduction techniques (ART). METHODS: Comparative cross-sectional study with 120 infertile women candidate to ART, assisted at Centro de Reprodução Assistida (CRA) of Hospital Regional da Asa Sul (HRAS), Brasília-DF, from August 2009 to November 2010. Sonohysterography was performed with saline solution infusion in a close system. The sonohysterography finding was compared to previous USG results. The uterine cavity was considered abnormal whenthe endometrium was found to be thicker than expectedduring the menstrual cycle and whenan endometrial polyp, a submucous myoma and an abnormal shape of the uterine cavity were observed. The statistical analysis was doneusing absolute frequencies, percentage values and the χ 2, with the level of significance set at5%. RESULTS:HSN revealed that 92 (76.7%) infertile women candidate to ARThad anormal uterine cavity, while 28 (23.3%) had the following abnormalities: 15 polyps (12.5%).
Resumo:
Making an artificial iris with an aesthetically acceptable color is an important aspect of ocular rehabilitation. This work evaluated the influence of different disinfecting solutions on changes to the color of artificial irises used in ocular prostheses. Fifty samples simulating ocular prostheses were produced with cobalt blue artificial irises and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite, and 4% chlorhexidine. The samples were disinfected for 120 days and subjected to a color readings by spectrophotometry, using the CIE L*a*b* system, before the disinfection period (B), after 60 days of disinfectant exposure (T 1), and after 120 days of disinfectant exposure (T 2). Color differences (ΔE) were calculated for the intervals between T 1 and B (T 1B), and between T 2 and B (T 2B). The data were evaluated by analysis of variance and the Tukey Honestly Significantly Different (α = 0.05). All disinfectant groups exhibited color changes. The mean color change observed for all groups overall during T 2B (ΔE = 3.51) was significantly greater than that observed during T 1B (ΔE = 2.10). All groups exhibited greater color change for the b* values when compared to the a* and L* values. There were no significant differences between the disinfectant groups. It can be concluded that the time period of disinfection and storage significantly affected the stability of artificial iris color, independent of the disinfectant used. © 2012 Wiley Periodicals, Inc.
Resumo:
Purpose: The aim of this study was to evaluate the expression of the protein annexin A1 (ANXA1), a potent endogenous regulator of the inflammatory process, in ocular toxoplasmosis. Methods: C57BL/6 female mice were infected using intravitreal injections of either 10 6 tachyzoites of Toxoplasma gondii (RH strain; T. gondii) or PBS only (control groups). After 24, 48, and 72 h, animals were sacrificed and their eyes were harvested for histopathological, immunohistochemical, and ultrastructural immunocytochemical analysis of ANXA1. Human retinal pigment epithelial (RPE) cells (ARPE-19) were infected in vitro with T. gondii and collected after 60, 120, 240 min, and 24 h. Results: Compared with non-infected eyes, an intense inflammatory response was observed in the anterior (24 h after infection) and posterior segments (72 h after infection) of the infected eye, characterized by neutrophil infiltration and by the presence of tachyzoites and their consequent destruction along with disorganization of normal retina architecture and RPE vacuolization. T. gondii infection was associated with a significant increase of ANXA1 expression in the neutrophils at 24, 48, and 72 h, and in the RPE at 48 and 72 h. In vitro studies confirmed an upregulation of ANXA1 levels in RPE cells, after 60 and 120 min of infection with T. gondii. Conclusions: The positive modulation of endogenous ANXA1 in the inflammatory and RPE cells during T. gondii infection suggests that this protein may serve as a therapeutic target in ocular toxoplasmosis. © 2012 Molecular Vision.
Resumo:
The aim of this study was to assess the improvement in psychosocial awareness of anophthalmic patients wearing ocular prostheses and its relationship with demographic characteristics, factors of loss/treatment, social activity, and relationship between professional and patient. Surveys including a form for evaluation of psychosocial pattern were conducted with 40 anophthalmic patients rehabilitated with ocular prosthesis at the Center of Oral Oncology in the authors' dental school from January 1998 to November 2010. The improvement in psychosocial awareness was assessed by comparing the perception of some feelings reported in the period of eye loss and currently. Wilcoxon tests were applied for comparison of patients' perception between the periods. χ2 tests were used to assess the relationship between the improvement in psychosocial awareness and the variables of the study. In addition, the logistic regression model measured this relationship with the measure of odds ratio. The feelings of shame, shyness, preoccupation with hiding it, sadness, insecurity and fear were significant for improvement in psychosocial awareness. It was concluded that the anophthalmic patients wearing an ocular prosthesis has significant improvement in psychosocial awareness after rehabilitation. © 2012 International Association of Oral and Maxillofacial Surgeons.
Resumo:
Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti-free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples. © 2012 The Gerodontology Society and John Wiley & Sons A/S.
Resumo:
The aim of this study was evaluate the renal hemodynamics of bitches with pyometra by means of laboratory tests, ultrasound B mode and Doppler, before and after treatment with ovariohysterectomy (OSH). This study evaluated 30 bitches with pyometra, all were subjected to OSH (moment 1) and 20 were evaluated after 7 days (moment 2). The renal perfusion, the resistivity index (RI) of the main renal artery and the interlobar arteries (cranial, middle and caudal) were statistically different between times 1 and 2 (p<0,05). There was no statistical difference for renal perfusion between the left and the right kidney at the time 1 and 2. The correlations between the IR of the main artery and the variables used to determine renal function were stablished at the time 1. For the correlated variables: urea, creatinine, proteinuria, ratio GGT/creatinine and protein/creatinine were curvilinear and positive associations with the resistivity index of the main renal artery (p<0,05), however these correlations were considered medium and weak. Comparing the RI of the main renal artery with different scores of dehydration and renal perfusion, there was statistical difference, and show increased of resistance renal in bitches with moderate reduction in renal perfusion as well as in dehydrated bitches. Were evaluated several features of renal morphology in ultrasound B mode, however, only the presence of pelvic dilatation, medullary signal and other changes as infarcts areas and diffuse hyperechoic spots in the renal cortical and medullary were statistically different from one moment to the other, most frequently at the time 2. The results of this study show that the Doppler ultrasound can identify changes of reduction in renal perfusion by color Doppler and the increasing of the resistivity index of the renal arteries in some bitches with pyometra. As well as, the ultrasound B mode, although has non-specific changes, can detect progressive renal disorders in bitches with pyometra.