994 resultados para orbital magnetization


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 12-year-old girl had a 6-year history of a large soft-tissue mass in her left orbit. The tumor biopsy was previously performed elsewhere when she was 7 years old, but no treatment was offered at that time. Later, the tumor was completely excised, and histologic examination revealed a mesenchymal neoplasia with typical hemangiopericytoma features. At 9 months of follow up, no evidence of local recurrence or metastasis was seen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven sides of cadaver heads were used to compare the surgical exposures provided by the mini-modified orbitozygomatic (MOz) and supra-orbital (SO) approaches. The Optotrak 3020 computerized tracking system (Northern Digital, Waterloo, ON, Canada) was utilized to evaluate the area of anatomical exposure defined by six points: (1) ipsilateral sphenoid ridge; (2) most distal point of the ipsilateral middle cerebral artery (MCA); (3) most distal point of the ipsilateral posterior cerebral artery (PCA); (4) most distal point of the contralateral PCA; (5) most distal point of the contralateral MCA; and (6) contralateral sphenoid ridge. Additionally, angles of approach for the ipsilateral MCA bifurcation, ipsilateral ICA bifurcation, basilar artery tip, contralateral MCA and ICA bifurcation and anterior communicating artery (AcomA) were evaluated, first for SO and then for MOz. An image guidance system was used to evaluate the limits of surgical exposure. No differences in the area of surgical exposure were noted (p > 0.05). Vertical angles were significantly wider for the ipsilateral and contralateral ICA bifurcation, AcomA, contralateral MCA and basilar tip (p < 0.05) for MOz. No differences in horizontal angles were observed between the approaches for the six targets (p > 0.05). There were no differences in the limits of exposure. MOz affords no additional surgical working space. However, our results demonstrate systematically that vertical exposure is improved. The MOz should be performed while planning an approach to these regions and a wider exposure in the vertical axis is needed. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the orbital evolution of a two co-orbital planet system which undergo tidal interactions with the central star. Our main goal is to investigate the final outcome of a system originally evolving in a 1:1 resonant configuration when the tidal effect acts to change the orbital elements. Preliminary results of the numerical simulations of the exact equations of motions indicate that, at least for equal mass planets, the combined effect of resonant motion and tidal interaction leads the system to orbital instability, including collisions between the planets. We discuss the cases of two hot super-Earths and two hot-Saturn planets, comparing with the results of dynamical maps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Key technology applications like magnetoresistive sensors or the Magnetic Random Access Memory (MRAM) require reproducible magnetic switching mechanisms. i.e. predefined remanent states. At the same time advanced magnetic recording schemes push the magnetic switching time into the gyromagnetic regime. According to the Landau-Lifschitz-Gilbert formalism, relevant questions herein are associated with magnetic excitations (eigenmodes) and damping processes in confined magnetic thin film structures.rnObjects of study in this thesis are antiparallel pinned synthetic spin valves as they are extensively used as read heads in today’s magnetic storage devices. In such devices a ferromagnetic layer of high coercivity is stabilized via an exchange bias field by an antiferromagnet. A second hard magnetic layer, separated by a non-magnetic spacer of defined thickness, aligns antiparallel to the first. The orientation of the magnetization vector in the third ferromagnetic NiFe layer of low coercivity - the freelayer - is then sensed by the Giant MagnetoResistance (GMR) effect. This thesis reports results of element specific Time Resolved Photo-Emission Electron Microscopy (TR-PEEM) to image the magnetization dynamics of the free layer alone via X-ray Circular Dichroism (XMCD) at the Ni-L3 X-ray absorption edge.rnThe ferromagnetic systems, i.e. micron-sized spin valve stacks of typically deltaR/R = 15% and Permalloy single layers, were deposited onto the pulse leading centre stripe of coplanar wave guides, built in thin film wafer technology. The ferromagnetic platelets have been applied with varying geometry (rectangles, ellipses and squares), lateral dimension (in the range of several micrometers) and orientation to the magnetic field pulse to study the magnetization behaviour in dependence of these magnitudes. The observation of magnetic switching processes in the gigahertz range became only possible due to the joined effort of producing ultra-short X-ray pulses at the synchrotron source BESSY II (operated in the so-called low-alpha mode) and optimizing the wave guide design of the samples for high frequency electromagnetic excitation (FWHM typically several 100 ps). Space and time resolution of the experiment could be reduced to d = 100 nm and deltat = 15 ps, respectively.rnIn conclusion, it could be shown that the magnetization dynamics of the free layer of a synthetic GMR spin valve stack deviates significantly from a simple phase coherent rotation. In fact, the dynamic response of the free layer is a superposition of an averaged critically damped precessional motion and localized higher order spin wave modes. In a square platelet a standing spin wave with a period of 600 ps (1.7 GHz) was observed. At a first glance, the damping coefficient was found to be independent of the shape of the spin-valve element, thus favouring the model of homogeneous rotation and damping. Only by building the difference in the magnetic rotation between the central region and the outer rim of the platelet, the spin wave becomes visible. As they provide an additional efficient channel for energy dissipation, spin waves contribute to a higher effective damping coefficient (alpha = 0.01). Damping and magnetic switching behaviour in spin valves thus depend on the geometry of the element. Micromagnetic simulations reproduce the observed higher-order spin wave mode.rnBesides the short-run behaviour of the magnetization of spin valves Permalloy single layers with thicknesses ranging from 3 to 40 nm have been studied. The phase velocity of a spin wave in a 3 nm thick ellipse could be determined to 8.100 m/s. In a rectangular structure exhibiting a Landau-Lifschitz like domain pattern, the speed of the field pulse induced displacement of a 90°-Néel wall has been determined to 15.000 m/s.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the last decades magnetic circular dichroism (MCD) has attracted much interest and evolved into various experimental methods for the investigation of magnetic thin films. For example, synchrotron-based X-ray magnetic circular dichroism (XMCD) displays the absolute values of spin and orbital magnetic moments. It thereby benefits from large asymmetry values of more than 30% due to the excitation of atomic core-levels. Similarly large values are also expected for threshold photoemission magnetic circular dichroism (TPMCD). Using lasers with photon energies in the range of the sample work function this method gives access to the occupied electronic structure close to the Fermi level. However, except for the case of Ni(001) there exist only few studies on TPMCD moreover revealing much smaller asymmetries than XMCD-measurements. Also the basic physical mechanisms of TPMCD are not satisfactorily understood. In this work we therefore investigate TPMCD in one- and two-photon photoemission (1PPE and 2PPE) for ferromagnetic Heusler alloys and ultrathin Co films using ultrashort pulsed laser light. The observed dichroism is explained by a non-conventional photoemission model using spin-resolved band-structure calculations and linear response theory. For the two Heusler alloys Ni2MnGa and Co2FeSi we give first evidence of TPMCD in the regime of two-photon photoemission. Systematic investigations concerning general properties of TPMCD in 1PPE and 2PPE are carried out at ultrathin Co films grown on Pt(111). Here, photon-energy dependent measurements reveal asymmetries of 1.9% in 1PPE and 11.7% in 2PPE. TPMCD measurements at decreased work function even yield larger asymmetries of 6.2% (1PPE) and 17% (2PPE), respectively. This demonstrates that enlarged asymmetries are also attainable for the TPMCD effect on Co(111). Furthermore, we find that the TPMCD asymmetry is bulk-sensitive for 1PPE and 2PPE. This means that the basic mechanism leading to the observed dichroism must be connected to Co bulk properties; surface effects do not play a crucial role. Finally, the enhanced TPMCD asymmetries in 2PPE compared to the 1PPE case are traced back to the dominant influence of the first excitation step and the existence of a real intermediate state. The observed TPMCD asymmetries cannot be interpreted by conventional photoemission theory which only considers direct interband transitions in the direction of observation (Γ-L). For Co(111), these transitions lead to evanescent final states. The excitation to such states, however, is incompatible with the measured bulk-sensitivity of the asymmetry. Therefore, we generalize this model by proposing the TPMCD signal to arise mostly from direct interband transitions in crystallographic directions other than (Γ-L). The necessary additional momentum transfer to the excited electrons is most probably provided by electron-phonon or -magnon scattering processes. Corresponding calculations on the basis of this model are in reasonable agreement with the experimental results so that this approach represents a promising tool for a quantitative description of the TPMCD effect. The present findings encourage an implementation of our experimental technique to time- and spatially-resolved photoemission electron microscopy, thereby enabling a real time imaging of magnetization dynamics of single excited states in a ferromagnetic material on a femtosecond timescale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die vorliegende Dissertation beschaftigt sich mit der Steuerung der Absorption und Orbitalenergien von Perylenmonoimiden und Perylendiimiden fur die Anwendung in organischer Photovoltaik (OPV). Eine breite Absorption spielt hier eine wichtige Rolle, um moglichst viel Licht zu ernten, das dann in elektrische Energie umgewandelt wird. Um sicher zu stellen, dass die Zelle ezient arbeiten kann, ist die Abstimmung von Orbitalenergien eine zweite wichtige Voraussetzung. Es werden drei neue Design-Konzepte fur Perylenmonoimid-Sensibilatoren fur Festk orper-Farbstosolarzellen (solid-state dye-sensitised solar cells - sDSSCs) untersucht. Die Synthese, die optischen und elektronischen Eigenschaften der neuen Sensibilisator- Verbindungen sowie ihre Leistungsdaten in sDSSCs werden beschrieben und diskutiert. Die in dieser Arbeit vorgestellten Konzepte reichen von der Einfuhrung von - Abstandhaltern uber neue Funktionalisierungen bis hin zur Erweiterung der Perylenmonimid Grundkorper. Der Push-Pull-Charakter der Systeme variiert von starker Kopplung bis zu kompletter Entkopplung des Donors vom Akzeptor. Dies hat einen starken Ein uss sowohl auf die Absorptionseigenschaften, als auch auf die HOMO/LUMO Energie-Niveaus der Verbindungen. Einige der Konzepte konnen auf Perylendiimide ubertragen werden. Ein Beispiel von Perylendiimid (PDI)-Farbsteuerung wird an einer Reihe von drei Terthiophen-PDIs gezeigt

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the use of computer-assisted designed and manufactured (CAD/CAM) orbital wall and floor implants for late reconstruction of extensive orbital fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the long-term clinical and radiologic findings after insertion of a bioresorbable polylactide plates P(L/DL)LA 70/30 implant (PolyMax) in the repair of orbital floor and wall defects, with special focus on stability and clinical signs of foreign-body reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to share our clinical experience in the use and accuracy of a newly designed, low-profile titanium mesh (Modus OPS 1.5; Medartis, Basel, Switzerland) for primary internal orbital reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of an accidental death or potential suicide by revolver with subsequent injury of another person. A 44-year-old man shot himself in the head while manipulating his.38 caliber special revolver in the kitchen in the presence of his wife, standing approximately 1.5 m next to him. After passing through the husband's head, the lead round-nose bullet entered the region underneath his wife's left eye. When the bullet left the man's head, it retained the energy to penetrate the soft tissue at this distance, including the skin and thin bone plates like the orbital wall. Owing to the low energy of the projectile, the entry wound was of atypical in shape and without loss of tissue. Only a small line-resembling a cut-was externally visible. The man died in the hospital from his injuries; his wife suffered visual loss of her left eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal hollowing due to temporal muscle atrophy after standard skull base surgery is common. Various techniques have been previously described to correct the disfiguring defect. Most often reconstruction is performed using freehand molded polymethylmethacrylate cement. This method and material are insufficient in terms of aesthetic results and implant characteristics. We herein propose reconstruction of such defects with a polyetheretherketone (PEEK)-based patient-specific implant (PSI) including soft-tissue augmentation to preserve normal facial topography. We describe a patient who presented with a large temporo-orbital hemangioma that had been repaired with polymethylmethacrylate 25 years earlier. Because of a toxic skin atrophy fistula, followed by infection and meningitis, this initial implant had to be removed. The large, disfiguring temporo-orbital defect was reconstructed with a PEEK-based PSI. The lateral orbital wall and the temporal muscle atrophy were augmented with computer-aided design and surface modeling techniques. The operative procedure to implant and adopt the reconstructed PEEK-based PSI was simple, and an excellent cosmetic outcome was achieved. The postoperative clinical course was uneventful over a 5-year follow-up period. Polyetheretherketone-based combined bony and soft contour remodeling is a feasible and effective method for cranioplasty including combined bone and soft-tissue reconstruction of temporo-orbital defects. Manual reconstruction of this cosmetically delicate area carries an exceptional risk of disfiguring results. Augmentation surgery in this anatomic location needs accurate PSIs to achieve satisfactory cosmetic results. The cosmetic outcome achieved in this case is superior compared with previously reported techniques.