914 resultados para efficiencies
Resumo:
As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.
Resumo:
The primary objective is to identify the critical factors that have a natural impact on the performance measurement system. It is important to make correct decisions related to measurement systems, which are based on the complex business environment. The performance measurement system is combined with a very complex non-linear factor. The Six Sigma methodology is seen as one potential approach at every organisational level. It will be linked to the performance and financial measurement as well as to the analytical thinking on which the viewpoint of management depends. The complex systems are connected to the customer relationship study. As the primary throughput can be seen in a new well-defined performance measurement structure that will also be facilitated as will an analytical multifactor system. These critical factors should also be seen as a business innovation opportunity at the same time. This master's thesis has been divided into two different theoretical parts. The empirical part consists of both action-oriented and constructive research approaches with an empirical case study. The secondary objective is to seek a competitive advantage factor with a new analytical tool and the Six Sigma thinking. Process and product capabilities will be linked to the contribution of complex system. These critical barriers will be identified by the performance measuring system. The secondary throughput can be recognised as the product and the process cost efficiencies which throughputs are achieved with an advantage of management. The performance measurement potential is related to the different productivity analysis. Productivity can be seen as one essential part of the competitive advantage factor.
Resumo:
All the experimental part of this final project was done at Laboratoire de Biotechnologie Environnementale (LBE) from the École Polytechnique Fédérale de Lausanne (EPFL), Switzerland, during 6 months (November 2013- May 2014). A fungal biofilter composed of woodchips was designed in order to remove micropollutants from the effluents of waste water treatment plants. Two fungi were tested: Pleurotus ostreatus and Trametes versicolor in order to evaluate their efficiency for the removal of two micropollutants: the anti-inflammatory drug naproxen and the antibiotic sulfamethoxazole,. Although Trametes versicolor was able to degrade quickly naproxen, this fungus was not any more active after one week of operation in the filter. Pleurotus ostreatus was, on contrary, able to survive more than 3 months in the filter, showing good removal efficiencies of naproxen and sulfamethoxazole during all this period, in tap water but also in real treated municipal wastewater. Several other experiments have provided insight on the removal mechanisms of these micropollutants in the fungal biofilter (degradation and adsorption) and also allowed to model the removal trend. Fungal treatment with Pleurotus ostreatus grown on wood substrates appeared to be a promising solution to improve micropollutants removal in wastewater.
Resumo:
Työn tarkoituksena oli hakea mittausjärjestelmän raja-arvoja optiselle kamerapohjaiselle roskalaskentajärjestelmälle sekä testata roskalaskentajärjestelmän toimivuus käytännössä. Tavoitteena oli tuotteistaa kamerapohjainen roskalaskenta-analyysi palvelutuotteeksi, jota voitaisiin hyödyntää sihtien kuntokartoituksessa ja ongelmanratkaisuvälineenä. Teoriaosa koostui kahdesta kokonaisuudesta: sulpun epäpuhtauksista, roskalaskennan teoriasta ja epäpuhtauksien mittausmenetelmistä sekä markkinoinnista, tuotteistamis- ja lanseerausprosessista palvelutuotteen näkökulmasta. Kokeellisessa osassa selvitettiin kamerapohjaiseen roskalaskentaanalyysiin vaikuttavia tekijöitä: kameran tarkennus, kuvan terävyys, analysoitavan arkin väri, neliömassa ja roskapitoisuus, impregnointi, valonlähde, kuvan muokkaus, tiedostomuoto ja pikselimäärä. Kamerapohjaisen roskalaskenta-analyysin soveltuvuus käytäntöön testattiin tehdasesimerkin avulla. Havaittiin, että kamerapohjaista roskalaskenta-analyysiä voitaisiin käyttää lähes kaikille massatyypeille. Työssä määriteltiin kalibrointimenetelmä kameran tarkentamiseksi arkin tasoon sekä suljinnopeusanalyysi massatyypistä riippuvan suljinnopeuden selvitykseen. Kamerapohjaisessa roskalaskenta-analyysissä määritettiin käytettäväksi arkin neliömassana 60 g/m2, suljinaukkoa F5 ja terävyysasetusta 5. Tulokseksi saatiin, että analysoitavia arkkeja ei tarvitse impregnoida tai jälkikäsitellä. Korrelaatiota Somerville-erotustehokkuuteen ei löytynyt. Esimerkkitehtaasta selvitettiin primääriportaan roskapitoisuudet ja erotustehokkuudet. Tehdasesimerkin tulosten perusteella havaittiin happivaiheen ja D0-vaiheen olleen tehokkaimpia epäpuhtauksien poistajia.
Resumo:
Tässä kandidaatintyössä on käsitelty akkuja ja vetypolttokennoja sähköauton voimanlähteenä. Työssä on esitelty sähköautojen ja niiden voimanlähteiden teknologioiden periaatteita, energiankantajia, hyötysuhteita ja päästöjä. Lisäksi on tarkasteltu polttomoottorikäyttöisiä autotekniikoita vertailukohdan saamiseksi. Työn lopuksi on analysoitu sähköautojen markkinoita ja niiden yleistymiseen vaikuttavia tekijöitä. Sähköautot mahdollistavat vaihtoehtoisten energialähteiden käytön, joka antaa tilaisuuden saasteiden ja päästöjen keskitettyyn vähentämiseen ja talteenottoon. Niiden avulla päästään myös pois öljyriippuvuudesta ja paikallisesti aiheutuneista päästöistä. Nykyisten polttoaineiden helpon käsiteltävyyden, kohtuullisien energiatiheyksien ja laajojen infrastruktuurien vuoksi käytössä olevien tekniikoiden syrjäyttäminen on vaikeaa. Uusien tekniikoiden etuja ja haittoja voidaan tarkastella yksinkertaisilla metodeilla, kuten kustannusten, hyötysuhteiden, päästöjen ja polttoaineiden elinkaarien vertailulla. Vertailua vaikeuttaa tosin hintatasojen ja verotuksen eroavaisuudet eri maissa, ja se on siksi suoritettava osin maakohtaisesti. Suurimpia esteitä uusille tekniikoille ovat tällä hetkellä niiden tuomat lisäkustannukset, infrastruktuurien puuttuminen ja nykyisten polttoaineiden korvaaminen toisella.
Resumo:
Fluorescence resonance energy transfer (FRET) is a non-radiative energy transfer from a fluorescent donor molecule to an appropriate acceptor molecule and a commonly used technique to develop homogeneous assays. If the emission spectrum of the donor overlaps with the excitation spectrum of the acceptor, FRET might occur. As a consequence, the emission of the donor is decreased and the emission of the acceptor (if fluorescent) increased. Furthermore, the distance between the donor and the acceptor needs to be short enough, commonly 10-100 Å. Typically, the close proximity between the donor and the acceptor is achieved via bioaffinity interactions e.g. antibody binding antigen. Large variety of donors and acceptors exist. The selection of the donor/acceptor pair should be done not only based on the requirements of FRET but also the performance expectancies and the objectives of the application should be considered. In this study, the exceptional fluorescence properties of the lanthanide chelates were employed to develop two novel homogeneous immunoassays: a non-competitive hapten (estradiol) assay based on a single binder and a dual-parametric total and free PSA assay. In addition, the quenching efficiencies and energy transfer properties of various donor/acceptor pairs were studied. The applied donors were either europium(III) or terbium(III) chelates; whereas several organic dyes (both fluorescent and quenchers) acted as acceptors. First, it was shown that if the interaction between the donor/acceptor complexes is of high quality (e.g. biotin-streptavidin) the fluorescence of the europium(III) chelate could be quenched rather efficiently. Furthermore, the quenching based homogeneous non-competitive assay for estradiol had significantly better sensitivity (~67 times) than a corresponding homogeneous competitive assay using the same assay components. Second, if the acceptors were chosen to emit at the emission minima of the terbium(III) chelate, several acceptor emissions could be measured simultaneously without significant cross-talk from other acceptors. Based on these results, the appropriate acceptors were chosen for the dual-parameter assay. The developed homogeneous dual-parameter assay was able to measure both total and free PSA simultaneously using a simple mix and measure protocol. Correlation of this assay to a heterogeneous single parameter assay was excellent (above 0.99 for both) when spiked human plasma samples were used. However, due to the interference of the sample material, the obtained concentrations were slightly lower with the homogeneous than the heterogeneous assay, especially for the free PSA. To conclude, in this work two novel immunoassay principles were developed, which both are adaptable to other analytes. However, the hapten assay requires a rather good antibody with low dissociation rate and high affinity; whereas the dual-parameter assay principle is applicable whenever two immunometric complexes can form simultaneously, provided that the requirements of FRET are fulfilled.
Resumo:
Human activities have resulted in increased nutrient levels in many rivers all over Europe. Sustainable management of river basins demands an assessment of the causes and consequences of human alteration of nutrient flows, together with an evaluation of management options. In the context of an integrated and interdisciplinary environmental assessment (IEA) of nutrient flows, we present and discuss the application of the nutrient emission model MONERIS (MOdelling Nutrient Emissions into River Systems) to the Catalan river basin, La Tordera (north-east Spain), for the period 1996–2002. After a successful calibration and verification process (Nash-Sutcliffe efficiencies E=0.85 for phosphorus and E=0.86 for nitrogen), the application of the model MONERIS proved to be useful in estimating nutrient loads. Crucial for model calibration, in-stream retention was estimated to be about 50 % of nutrient emissions on an annual basis. Through this process, we identified the importance of point sources for phosphorus emissions (about 94% for 1996–2002), and diffuse sources, especially inputs via groundwater, for nitrogen emissions (about 31% for 1996–2002). Despite hurdles related to model structure, observed loads, and input data encountered during the modelling process, MONERIS provided a good representation of the major interannual and spatial patterns in nutrient emissions. An analysis of the model uncertainty and sensitivity to input data indicates that the model MONERIS, even in data-starved Mediterranean catchments, may be profitably used by water managers for evaluating quantitative nutrient emission scenarios for the purpose of managing river basins. As an example of scenario modelling, an analysis of the changes in nutrient emissions through two different future scenarios allowed the identification of a set of relevant measures to reduce nutrient loads.
Resumo:
Very often hydrochloric acid is employed in acidification operations aiming to dissolve the mineral matrix in petroleum wheel operations, which always require intense use of corrosion inhibitors. This work presents an evaluation of common indicators, phenolfthaleine, fluorescein, methylene blue, alizarine S and methyl orange, as corrosion inhibitors for carbon steel in HCl 15% w/v at temperatures of 26, 40 and 60 ºC. Fluorescein and methyl orange show excelent corrosion inhibition efficiencies at 26 ºC; however at 60 ºC only fluorescein shows good corrosion inhibition when employed with alcohol and/or formaldehyde. For the fluorescein 1% w/v + formaldehyde 0.6% w/v mixture we present polarization and impedance curves and adsorption isotherms.
Resumo:
Diplomityön tavoitteena on selvittää Loviisan ydinvoimalaitoksen höyryturbiinin hyötysuhteen parantamismahdollisuuksia. Työn kuvaan liittyvät oleellisesti höyryturbiinin siipivyöhykkeiden nopeuskolmioiden sekä hyötysuhteiden laskenta. Höyryturbiinien kehityskaarta sekä turbiinin häviökerrointen laskentayhtälöitä on esitetty useasta eri lähteestä ja vuosikymmeniltä. Työssä selvitettiin uusimpia ydinvoimalaitosten kostea höyryturbiinien suunnitteluperusteita lukuisista eri lähteistä. Kaikkien lähteiden mukaan kostean höyryn alueella tapahtuvaa paisuntaa on haasteellista mallintaa. Työssä on esitelty artikkeleissa tulleita eri näkökulmia höyryturbiinien suorituskyvyn parantamiseksi, sekä rakenteellisia että laskennallisia. Työssä esitellään monia turbiinin virtauksen ja suorituskyvyn laskentamenetelmiä. Esimerkiksi Baumannin säännön laskenta on yksinkertainen tapa käsitellä turbiinin suorituskykyä kostean höyryn alueella. Keskeisimpiä tehtyjä havaintoja oli se, että korkeapaineturbiinin ensimmäisestä vaiheesta löytyi mahdollista parannuspotentiaalia Loviisaan ydinvoimalaitoksen tehon lisäämiseksi. Ensimmäisessä vaiheessa on oletettu siipien olevan Laval –tyyppisiä, mutta käytännössä näin ei ole. Korkeapaineturbiinin nykyisen turbosuuttimen toimintaa voitaisiin tehostaa. Lisäksi Loviisan matalapaineturbiinin viimeisen siipivaiheen jälkeen aiheutuu suuret ulosvirtaushäviöt. Osa suurinopeuksisen virtauksen energiasta pystyttäisiin kuitenkin hyödyntämään vielä ulosvirtauskanavassa olevalla diffuusorilla.
Resumo:
A method is proposed for the determination of the moisture content of aromatic plants. This method is based on the co-distillation of the starting material in a modified Clevenger apparatus with four organic solvents (toluene, cyclohexane, dichloromethane and carbon tetrachloride). The results were compared with those obtained by oven drying at 105 ºC and steam distillation of the essential oil. The efficiencies of the methods were shown to be equivalent. The solvent distillation method was more practical, especially with respect to operating time (2 h).
Resumo:
Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finflo, which is a Navier-Stokes solver. All the cases are modeled with the Chien's k – έ- turbulence model, and selected cases are modeled also with the k – ώ-SST turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements. When comparing the computational results to the measured results, it is evident that the k – ώ-SST turbulence model predicts the flow fields better. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher efficiency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller efficiency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency, the increment being 1...3 percentage points, when compared to the vaneless unpinched geometry. The measurement results confirm that the pinch is beneficial to the performance of the compressor. The flow fields are more uniform with the pinched cases, and the slow flow regions are smaller. The peak efficiency is approximately 2 percentage points and the design point efficiency approximately 4 percentage points higher with the pinched geometries than with the un- pinched geometry. According to the measurements, the two best geometries are the ones with the most pinch at the shroud, the case with the pinch only at the shroud being slightly better of the two. The vaned diffusers also have better efficiency than the vaneless unpinched geometries. However, the pinched cases have even better efficiencies. The vaned diffusers narrow the operating range considerably, whilst the pinch has no significant effect on the operating range.
Resumo:
Occurrence and removal of 81 representative Pharmaceutical Active Compounds (PhACs) were assessed in a municipal WWTP located in a highly industrialized area, with partial water reuse after UV tertiary treatment and discharge to a Mediterranean river. Water monitoring was performed in an integrated way at different points in the WWTP and river along three seasons. Consistent differences between therapeutic classes were observed in terms of influent concentration, removal efficiencies and seasonal variation. Conventional (primary and secondary) treatment was unable to completely remove numerous compounds and UV-based tertiary treatment played a complementary role for some of them. Industrial activity influence was highlighted in terms of PhACs presence and seasonal distribution. Even if global WWTP effluent impact on the studied river appeared to be minor, PhACs resulted widespread pollutants in river waters. Contamination can be particularly critical in summer in water scarcity areas, when water flow decreases considerably
Resumo:
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions
Resumo:
The influences of the spray-drying parameters and the type of nanoparticles (nanocapsules or nanospheres) on the characteristics of nanoparticle-coated diclofenac-loaded microparticles were investigated by using a factorial design 3². Gastrointestinal tolerance following oral administration in rats was evaluated. Formulations were selected considering the best yields, the best encapsulation efficiencies and the lowest water contents, presenting surfaces completely coated by nanostructures and a decrease in the surface areas in relation to the uncoated core. In vitro drug release demonstrated the influence of the nanoparticle-coating on the dissolution profiles of diclofenac. Nanocapsule-coated microparticles presented a protective effect on the gastrointestinal mucosa.
Resumo:
Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.