818 resultados para Wire electrical discharge machining


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To identify individual and hospital characteristics associated with the risk of readmission in older inpatients for proximal femoral fracture in the period of 90 days after discharge. METHODS Deaths and readmissions were obtained by a linkage of databases of the Hospital Information System of the Unified Health System and the System of Information on Mortality of the city of Rio de Janeiro from 2008 to 2011. The population of 3,405 individuals aged 60 or older, with non-elective hospitalization for proximal femoral fracture was followed for 90 days after discharge. Cox multilevel model was used for discharge time until readmission, and the characteristics of the patients were used on the first level and the characteristics of the hospitals on the second level. RESULTS The risk of readmission was higher for men (hazard ratio [HR] = 1.37; 95%CI 1.08–1.73), individuals more than 79 years old (HR = 1.45; 95%CI 1.06–1.98), patients who were hospitalized for more than two weeks (HR = 1.33; 95%CI 1.06-1.67), and for those who underwent arthroplasty when compared with the ones who underwent osteosynthesis (HR = 0.57; 95%CI 0.41–0.79). Besides, patients admitted to state hospitals had lower risk for readmission when compared with inpatients in municipal (HR = 1.71; 95%CI 1.09–2.68) and federal hospitals (HR = 1.81; 95%CI 1.00–3.27). The random effect of the hospitals in the adjusted model remained statistically significant (p < 0.05). CONCLUSIONS Hospitals have complex structures that reflect in the quality of care. Thus, we propose that future studies may include these complexities and the severity of the patients in the analysis of the data, also considering the correlation between readmission and mortality to reduce biases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report and analyze the halting of the fuse effect propagation in optical fiber microwires. The increase of the mode field diameter in the tapered region decreases the optical intensity resulting in the extinction of the fuse effect. This fiber element presents a low insertion loss and can be introduced in the optical network in order to protect the active equipment from the damage caused by the fuse effect. (C) 2012 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fractional calculus (FC) is no longer considered solely from a mathematical viewpoint, and is now applied in many emerging scientific areas, such as electricity, magnetism, mechanics, fluid dynamics, and medicine. In the field of dynamical systems, significant work has been carried out proving the importance of fractional order mathematical models. This article studies the electrical impedance of vegetables and fruits from a FC perspective. From this line of thought, several experiments are developed for measuring the impedance of botanical elements. The results are analyzed using Bode and polar diagrams, which lead to electrical circuit models revealing fractional-order behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Física - Física Aplicada pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we present the explicit series solution of a specific mathematical model from the literature, the Deng bursting model, that mimics the glucose-induced electrical activity of pancreatic beta-cells (Deng, 1993). To serve to this purpose, we use a technique developed to find analytic approximate solutions for strongly nonlinear problems. This analytical algorithm involves an auxiliary parameter which provides us with an efficient way to ensure the rapid and accurate convergence to the exact solution of the bursting model. By using the homotopy solution, we investigate the dynamical effect of a biologically meaningful bifurcation parameter rho, which increases with the glucose concentration. Our analytical results are found to be in excellent agreement with the numerical ones. This work provides an illustration of how our understanding of biophysically motivated models can be directly enhanced by the application of a newly analytic method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um dos princípios da Gestão é: “If you cannot measure it, you cannot improve it.” In The Economist – 26.Dez.2008, idea of 19th century English physicist Lord Kelvin. Embora seja uma afirmação aplicável à gestão económica, também pode ser utilizada no domínio da gestão da energia. Este trabalho surge da necessidade sentida pela empresa Continental - Industria Têxtil do Ave, S.A. em efetuar uma atualização dos seus standards de produção, minimizando os seus consumos de eletricidade e gás natural. Foi necessário efetuar o levantamento dos consumos em diversas máquinas e equipamentos industriais, caracterizando e analisando os consumos ao longo de todo o processo produtivo. Para o tratamento de dados recolhidos foi desenvolvida uma folha de cálculo em MS Office ExcelTM com metodologia adequada ao equipamento em análise, que dará apoio ao decisor para a identificação dos aspetos que melhorem o processo produtivo e garantam uma elevada eficiência energética. Porém, não se enquadra no âmbito do Plano Nacional de Racionalização de Energia, sendo uma “auditoria energética” ao processo produtivo. Recentemente, a empresa, tem vindo a utilizar equipamentos eletrónicos que permitem otimizar o funcionamento mecânico dos equipamentos e das potências instaladas dos transformadores, na tentativa de racionalizar o consumo da energia elétrica. Outros equipamentos como, conversores de frequência para controlo de motores, balastros eletrónicos que substituem os convencionais balastros ferromagnéticos das lâmpadas de descarga fluorescente, têm sido incluídos ao nível das instalações elétricas, sendo gradualmente substituída a eletromecânica pela eletrónica. Este tipo de soluções vem deteriorar as formas de onda da corrente e da tensão do sistema pela introdução de distorções harmónicas. Faz ainda parte deste trabalho, um estudo de uma solução que melhore, simultaneamente o fator de potência e reduza as harmónicas presentes num posto de transformação localizado no seio da fábrica. Esta solução, permite melhorar a qualidade da energia elétrica e as condições de continuidade de serviço, garantindo melhores condições de exploração e incrementando a produtividade da empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intelligent electrical grids can be considered as the next generation of electrical energy transportation. The enormous potential leads to worldwide focus of research on the technology of smart grids. This paper aims to present a review of the Brazilian electricity sector in context with the integration of communication technologies for smart grids. The work gives an overview of the generation, transmission and distribution of electrical energy in the Brazil and a brief summary of the current electricity market. Smart grid technologies are introduced and the requirements for the Brazilian power system are pointed out. Various technologies for communication within an intelligent network are presented and their characteristics, advantages and disadvantages are compared to the Brazilian conditions. In addition, a summary is given of current pilot projects for Smart Grid technologies within Brazil, as well as a presentation of individual selected projects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sol-gel chemistry allows the immobilization of organic molecules of biological origin on suibtable solid supports, permitting their integration into biosensing devices widening the possibility of local applications. The present work is an application of this principle, where the link between electrical receptor platform and the antibody acting as biorecognition element is made by sol-gel chemistry. The immunosensor design was targeted for carcinoembryonic antigen (CEA), an important biomarker for screening the colorectal cancer, by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SVW). The device displayed linear behavior to CEA in EIS and in SWV assays ranging from 0.50 to 1.5ng/mL, and 0.25 to 1.5ng/mL, respectively. The corresponding detection limits were 0.42 and 0.043 ng/mL. Raman spectroscopy was used to characterize the surface modifications on the conductive platform (FTO glass). Overall, simple sol-gel chemistry was effective at the biosensing design and the presented approach can be a potential method for screening CEA in point-of-care, due to the simplicity of fabrication, short response time and low cost. - See more at: http://www.eurekaselect.com/127192/article#sthash.m1AWhINx.dpuf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Until this day, the most efficient Cu(In,Ga)Se2 thin film solar cells have been prepared using a rather complex growth process often referred to as three-stage or multistage. This family of processes is mainly characterized by a first step deposited with only In, Ga and Se flux to form a first layer. Cu is added in a second step until the film becomes slightly Cu-rich, where-after the film is converted to its final Cu-poor composition by a third stage, again with no or very little addition of Cu. In this paper, a comparison between solar cells prepared with the three-stage process and a one-stage/in-line process with the same composition, thickness, and solar cell stack is made. The one-stage process is easier to be used in an industrial scale and do not have Cu-rich transitions. The samples were analyzed using glow discharge optical emission spectroscopy, scanning electron microscopy, X-ray diffraction, current–voltage-temperature, capacitance-voltage, external quantum efficiency, transmission/reflection, and photoluminescence. It was concluded that in spite of differences in the texturing, morphology and Ga gradient, the electrical performance of the two types of samples is quite similar as demonstrated by the similar J–V behavior, quantum spectral response, and the estimated recombination losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Mortality after ICU discharge accounts for approx. 20-30% of deaths. We examined whether post-ICU discharge mortality is associated with the presence and severity of organ dysfunction/failure just before ICU discharge. PATIENTS AND METHODS: The study used the database of the EURICUS-II study, with a total of 4,621 patients, including 2,958 discharged alive to the general wards (post-ICU mortality 8.6%). Over a 4-month period we collected clinical and demographic characteristics, including the Simplified Acute Physiology Score (SAPS II), Nine Equivalents of Nursing Manpower Use Score, and Sequential Organ Failure Assessment (SOFA) score. RESULTS: Those who died in the hospital after ICU discharge had a higher SAPS II score, were more frequently nonoperative, admitted from the ward, and had stayed longer in the ICU. Their degree of organ dysfunction/failure was higher (admission, maximum, and delta SOFA scores). They required more nursing workload resources while in the ICU. Both the amount of organ dysfunction/failure (especially cardiovascular, neurological, renal, and respiratory) and the amount of nursing workload that they required on the day before discharge were higher. The presence of residual CNS and renal dysfunction/failure were especially prognostic factors at ICU discharge. Multivariate analysis showed only predischarge organ dysfunction/failure to be important; thus the increased use of nursing workload resources before discharge probably reflects only the underlying organ dysfunction/failure. CONCLUSIONS: It is better to delay the discharge of a patient with organ dysfunction/failure from the ICU, unless adequate monitoring and therapeutic resources are available in the ward.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A indústria automóvel necessita aumentar a produtividade de forma sistemática, com vista à redução de custos e incremento da competitividade. A otimização dos produtos e processos é uma constante. O presente trabalho foi solicitado pela empresa FicoCables, do Grupo FICOSA, tendo em vista a otimização do processo de injeção de pequenas peças injetadas em ZAMAK, que constituem o bloqueio na extremidade de cada cabo metálico inserido nos automóveis para abertura da mala, portas, travão de mão, reservatório de combustível, capô, etc. A empresa possui cerca de 52 equipamentos de injeção de ZAMAK, cuja temperatura dos bicos era mantida com base numa chama de gás. Os sucessivos problemas de controlo do sistema ditaram uma mudança estratégica no aquecimento desses bicos, passando a ser usadas resistências elétricas anelares. No entanto, esta mudança veio a apresentar problemas inesperados, os quais se vieram inclusivamente a tornar em problemas de segurança, devido ao desgaste interior prematuro dos bicos, os quais apresentaram esmo problema de rotura. Paralelamente, todos os parâmetros relacionados com este processo de fabrico estavam também estudados de forma algo incipiente, pelo que se tornou necessário compreender e dissecar todas as variáveis relacionadas com o processo e implementar sistemas que impedissem o ajuste não controlado dos parâmetros por parte dos operadores. Também os moldes foram alvo de ações de melhoria, com vista a evitar problemas na zona de contacto do bico com o molde. O processo foi analisado em pormenor, permitindo um controlo muito mais apurado do mesmo. Os resultados fizeram sentir-se de forma imediata, graças ao trabalho desenvolvido neste estudo e à abertura demonstrada pela empresa para implementar todas as soluções propostas. O resultado final traduz-se num incremento significativo da segurança para os operadores, num controlo muito mais apurado de todos os parâmetros envolvidos no processo, numa maior garantia da qualidade nos produtos injetados em ZAMAK e em ganhos financeiros significativos para a empresa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use, manipulation and application of electrical currents, as a controlled interference mechanism in the human body system, is currently a strong source of motivation to researchers in areas such as clinical, sports, neuroscience, amongst others. In electrical stimulation (ES), the current applied to tissue is traditionally controlled concerning stimulation amplitude, frequency and pulse-width. The main drawbacks of the transcutaneous ES are the rapid fatigue induction and the high discomfort induced by the non-selective activation of nervous fibers. There are, however, electrophysiological parameters whose response, like the response to different stimulation waveforms, polarity or a personalized charge control, is still unknown. The study of the following questions is of great importance: What is the physiological effect of the electric pulse parametrization concerning charge, waveform and polarity? Does the effect change with the clinical condition of the subjects? The parametrization influence on muscle recruitment can retard fatigue onset? Can parametrization enable fiber selectivity, optimizing the motor fibers recruitment rather than the nervous fibers, reducing contraction discomfort? Current hardware solutions lack flexibility at the level of stimulation control and physiological response assessment. To answer these questions, a miniaturized, portable and wireless controlled device with ES functions and full integration with a generic biosignals acquisition platform has been created. Hardware was also developed to provide complete freedom for controlling the applied current with respect to the waveform, polarity, frequency, amplitude, pulse-width and duration. The impact of the methodologies developed is successfully applied and evaluated in the contexts of fundamental electrophysiology, psycho-motor rehabilitation and neuromuscular disorders diagnosis. This PhD project was carried out in the Physics Department of Faculty of Sciences and Technology (FCT-UNL), in straight collaboration with PLUX - Wireless Biosignals S.A. company and co-funded by the Foundation for Science and Technology.