902 resultados para prosthetic devices
Resumo:
Prosthetic joint replacement is one of the most successful surgical procedures of the last century and the number of implanted artificial joints is rapidly growing. While the result of the procedure is generally positive, infections may occur leading to patient suffering, surgeon's frustration and important costs to the health system. Infection after prosthetic joint replacement is thus a feared complication as healing rates can be low, functional result poor and satisfaction of the patient abysmal. However, if a patient-adapted treatment of infected total joints is used, an overall success rate of above 90 % can be obtained. The patient-adapted treatment concept is based on five strong pillars: teamwork, understanding biofilm, proper diagnostics, proper definition and classification and patient-tailored treatment.
Resumo:
The objective of this study has been to make a profitability analysis of service contracts for a company in Finland. The purpose has been to see how profitable the contracts are and if there possibly were some things to change or develop in the contracts. Allocation rules of cost accounting, service costs both profitability and management of services have been considered in the theory part. All the service contracts that have been valid at least three last accounting periods have been included in the study. All direct costs relating to the contracts have been collected and indirect costs have been assigned to the contracts. Profitability of the contracts has been calculated over three years. Results have been analyzed according to the key figures the company is controlling. Some suggestions for developments have been given at the end of the study. The study has shown differences between the contracts. Part of them has turned out to be like the profitability aims of the company and part less profitable. The study has shown that many factors have an effect on the profitability of the service contracts.
Resumo:
Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.
Resumo:
Different therapeutic options for prosthetic joint infections exist, but surgery remains the key. With a two-stage exchange procedure, a success rate above 90% can be expected. Currently, there is no consensus regarding the optimal duration between explantation and the reimplantation in a two-stage procedure. The aim of this study was to retrospectively compare treatment outcomes between short-interval and long-interval two-stage exchanges. Patients having a two-stage exchange of a hip or knee prosthetic joint infection at Lausanne University Hospital (Switzerland) between 1999 and 2013 were included. The satisfaction of the patient, the function of the articulation and the eradication of infection, were compared between patients having a short (2 to 4 weeks) versus a long (4 weeks and more) interval during a two-stage procedure. Patient satisfaction was defined as good if the patient did not have pain and bad if the patient had pain. Functional outcome was defined good if the patient had a prosthesis in place and could walk, medium if the prosthesis was in place but the patient could not walk, and bad if the prosthesis was no longer in place. Infection outcome was considered good if there had been no re-infection and bad if there had been a re-infection of the prosthesis 145 patients (100 hips, 45 knees) were identified with a median age of 68 years (range 19-103). The median hospital stay was 58 days (range 10-402). The median follow-up was 12.9 months (range 0.5-152). 28 % and 72 % of the patients had a short-interval and long-interval exchange of the prosthesis, respectively. Patient satisfaction, functional outcome and infection outcome for patients having a short versus a long interval are reported in the Table. The patient satisfaction was higher when a long interval was performed whereas the functional and infection outcomes were higher when a short interval was performed. According to this study a short-interval exchange appears preferable to a long interval, especially in the view of treatment effectiveness and functional outcome.
Resumo:
Hip joint replacement is 1 of the most successful surgical procedures of the last century and the number of replacements implanted is steadily growing. An infected hip arthroplasty is a disaster, it leads to patient suffering, surgeon's frustration and significant costs to the health system. The treatment of an infected hip replacement is challenging, healing rates can be low, functional results poor with decreased patient satisfaction. However, if a patient-adapted treatment of infected hip joints is used a success rate of above 90% can be obtained.Patient-adapted treatment is based on 5 important concepts: teamwork; understanding the biofilm; diagnostic accuracy; correct definition and classification of PJI; and patient-tailored treatment.This review presents a patient-adapted treatment strategy to prosthetic hip infection. It incorporates the best aspects of the single and staged surgical strategies and promotes the short interval philosophy for the 2-stage approach.
Resumo:
In the health domain, the field of rehabilitation suffers from a lack specialized staff while hospital costs only increase. Worse, almost no tools are dedicated to motivate patients or help the personnel to carry out monitoring of therapeutic exercises. This paper demonstrates the high potential that can bring the virtual reality with a platform of serious games for the rehabilitation of the legs involving a head-mounted display and haptic robot devices. We first introduce SG principles and the current context regarding rehabilitation interventions followed by the description of an original haptic device called Lambda Health System. The architecture of the model is then detailed, including communication specifications showing that lag is imperceptible for user (60Hz). Finally, four serious games for rehabilitation using haptic robots and/or HMD were tested by 33 health specialists.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
Context awareness is emerging on mobile devices. Context awareness can be used to improve usability of a mobile device. Context awareness is particularly important on mobile devices due the limitations they have. At first in this work, a literature review on context awareness and mobile environment is made. For aiding context awareness there exist an implementation of a Context Framework for Symbian S60 devices. It provides a possibility for exchanging the contexts inside the device between the client applications of the local Context Framework. The main contribution of this thesis is to design and implement an enhancement to the S60 Context Framework for providing possibility to exchange context over device boundaries. Using the implemented Context Exchange System, the context exchange is neither depending on the type of the context nor the type of the client. In addition, the clients and the contexts can reside on any interconnected device. The usage of the system is independent of the programming language since in addition to using only Symbian C++ function interfaces it can also be utilized using XML scripts. The Meeting Sniffer application, which uses the Context Exchange System, was also developed in this work. Using this application, it is possible to recognize a meeting situation and suggest device profile change to a user.
Resumo:
Current technology trends in medical device industry calls for fabrication of massive arrays of microfeatures such as microchannels on to nonsilicon material substrates with high accuracy, superior precision, and high throughput. Microchannels are typical features used in medical devices for medication dosing into the human body, analyzing DNA arrays or cell cultures. In this study, the capabilities of machining systems for micro-end milling have been evaluated by conducting experiments, regression modeling, and response surface methodology. In machining experiments by using micromilling, arrays of microchannels are fabricated on aluminium and titanium plates, and the feature size and accuracy (width and depth) and surface roughness are measured. Multicriteria decision making for material and process parameters selection for desired accuracy is investigated by using particle swarm optimization (PSO) method, which is an evolutionary computation method inspired by genetic algorithms (GA). Appropriate regression models are utilized within the PSO and optimum selection of micromilling parameters; microchannel feature accuracy and surface roughness are performed. An analysis for optimal micromachining parameters in decision variable space is also conducted. This study demonstrates the advantages of evolutionary computing algorithms in micromilling decision making and process optimization investigations and can be expanded to other applications
Resumo:
The purpose of this thesis was to study how certificates could be used to improve security of mobile devices. In the theoretical part the usage of certificates to improve security is explained. In the practical part a concept of certificate handling middleware is introduced and implemented. This is to demonstrate what kind of functionality is needed to provide an improvement over the current situation in security with mobile devices. The certificate handling middleware is a concept that would work better if implemented directly into mobile device's core functionality. Many of the mobile devices have a certificate store to some degree and often it is not used to store other people's certificates. A certificate store combined with address book and added with possibility to add attributes to the people such as group memberships would be sufficient to satisfy the needs of many emerging sharing and social applications.
Resumo:
This thesis discusses the design and implementation of a real-time musical pair improvisation scenario for mobile devices. In the scenario transferring musical information over a network connection was required. The suitability of available wireless communication technologies was evaluated and communication was analyzed and designed on multiple layers of TCP/IP protocol stack. Also an application layer protocol was designed and implemented for the scenario. The implementation was integrated into a mobile musical software for children using available software components and libraries although the used platform lead to hardware and software constraints. Software limitations were taken into account in design. The results show that real-time musical improvisation can be implemented with wireless communication and mobile technology. The results also show that link layer had the most significant effect on real-time communication in the scenario.
Resumo:
Along with the increasing in demand of mobile computing, Push Notification (PN) is widely used in mobile phones and other devices. PN allows the developer to send messages to the end users even when the client application is not running at the moment. This solves the problem produced by non-supported multi-tasking feature as well as saving battery life. Microsoft Push Notification Service (MPNS) is one solution to use PNs in Windows Phones. The thesis gives the developers an idea of how to use PNs by introducing MPNS, comparing MPNS with other Push Notification Services, usage of different PN types analysis, and PN simulation system implementation.
Resumo:
The forthcoming media revolution of exchanging paper documents to digital media in construction engineering requires new tools to be developed. The basis of this bachelor’s thesis was to explore the preliminary possibilities of exporting imagery from a Building Information Modelling –software to a mobile phone on a construction yard. This was done by producing a Web Service which uses the design software’s Application Programming Interface to interact with a structures model in order to produce the requested imagery. While mobile phones were found lacking as client devices, because of limited processing power and small displays, the implementation showed that the Tekla Structures API can be used to automatically produce various types of imagery. Web Services can be used to transfer this data to the client. Before further development the needs of the contractor, benefits for the building master and inspector and the full potential of the BIM-software need to be mapped out with surveys.
Resumo:
Purpose To evaluate the compliance and degree of satisfaction of nulligravida (has not given birth) and parous (had already given birth) women who are using intrauterine devices (IUDs). Methods A cross-sectional cohort study was conducted comparing nulligravida and parous women who had had an IUD inserted between July 2009 and November 2011. A total of 84 nulligravida women and 73 parous women were included. Interviews were conducted with women who agreed to participate through telephone contact. Statistical analysis was performed with Student s t-test and Mann-Whitney test for numeric variables; Pearson s chi-square test to test associations; and, whenever pertinent, Fisher s exact test for categorical variables. A survival curve was constructed to estimate the likelihood of each woman continuing the use of the IUD. A significance level of 5% was established. Results When compared with parous women, nulligravida women had a higher education level (median: 12 vs. 10 years). No statistically significant differences were found between the nulligravida and parous women with respect to information on the use of the IUD, prior use of other contraceptive methods, the reason for having chosen the IUD as the current contraceptive method, reasons for discontinuing the use and adverse effects, compliance, and degree of satisfaction. The two groups did not show any difference in terms of continued use of the IUD (p = 0.4). Conclusion There was no difference in compliance or the degree of satisfaction or continued use of IUDs between nulligravida and parous women, suggesting that IUD use may be recommended for women who have never been pregnant.