811 resultados para Diagnostic validity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 300-strong Angus-Brahman cattle herd near Springsure, central Queensland, was being fed Acacia shirleyi (lancewood) browse during drought and crossed a 5-hectare, previously burnt area with an almost pure growth of Dysphania glomulifera subspecies glomulifera (red crumbweed) on their way to drinking water. Forty cows died of cyanide poisoning over 2 days before further access to the plant was prevented. A digital image of a plant specimen made on a flat-bed scanner and transmitted by email was used to identify D glomulifera. Specific advice on the plant's poisonous properties and management of the case was then provided by email within 2 hours of an initial telephone call by the field veterinarian to the laboratory some 600 km away. The conventional method using physical transport of a pressed dried plant specimen to confirm the identification took 5 days. D glomulifera was identified in the rumen of one of two cows necropsied. The cyanogenic potential of D glomulifera measured 4 days after collection from the site of cattle deaths was 18,600 mg HCN/kg in dry matter. The lethal dose of D glomulifera for a 420 kg cow was estimated as 150 to 190 g wet weight. The plant also contained 4.8% KNO3 equivalent in dry matter, but nitrate-nitrite poisoning was not involved in the deaths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Attention deficit hyperactivity disorder (ADHD) is a life-long condition, but because of its historical status as a self-remitting disorder of childhood, empirically validated and reliable methods for the assessment of adults are scarce. In this study, the validity and reliability of the Wender Utah Rating Scale (WURS) and the Adult Problem Questionnaire (APQ), which survey childhood and current symptoms of ADHD, respectively, were studied in a Finnish sample. Methods: The self-rating scales were administered to adults with an ADHD diagnosis (n = 38), healthy control participants (n = 41), and adults diagnosed with dyslexia (n = 37). Items of the self-rating scales were subjected to factor analyses, after which the reliability and discriminatory power of the subscales, derived from the factors, were examined. The effects of group and gender on the subscales of both rating scales were studied. Additionally, the effect of age on the subscales of the WURS was investigated. Finally, the diagnostic accuracy of the total scores was studied. Results: On the basis of the factor analyses, a four-factor structure for the WURS and five-factor structure for the APQ had the best fit to the data. All of the subscales of the APQ and three of the WURS achieved sufficient reliability. The ADHD group had the highest scores on all of the subscales of the APQ, whereas two of the subscales of the WURS did not statistically differ between the ADHD and the Dyslexia group. None of the subscales of the WURS or the APQ was associated with the participant's gender. However, one subscale of the WURS describing dysthymia was positively correlated with the participant's age. With the WURS, the probability of a correct positive classification was .59 in the current sample and .21 when the relatively low prevalence of adult ADHD was taken into account. The probabilities of correct positive classifications with the APQ were .71 and .23, respectively. Conclusions: The WURS and the APQ can provide accurate and reliable information of childhood and adult ADHD symptoms, given some important constraints. Classifications made on the basis of the total scores are reliable predictors of ADHD diagnosis only in populations with a high proportion of ADHD and a low proportion of other similar disorders. The subscale scores can provide detailed information of an individual's symptoms if the characteristics and limitations of each domain are taken into account. Improvements are suggested for two subscales of the WURS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To test the robustness and validity of our prototype LPS-specific multiplex PCR on P. multocida field isolates and develop the PCR into a diagnostic test capable of accurately and reliably typing P. multocida strains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enhanced diagnostic platforms for Post Entry Quarantine (PEQ) and market access (Phase 1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of a national diagnostic database for Emergency Plant Pests which will be web-accessible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Develop and implement a diagnostic framework designed to help advisors and farmers identify the causes of poor crop performance and implement appropriate remedial measures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate identification of pests is essential for practically all aspects of agricultural development and is critical to the operations of biosecurity that safeguard agricultural integrity and facilitate trade. Diagnostic capability is at the forefront of and complementary to, activities such as border protection, incursion management, surveillance and pest and disease certification. The efficiency of a biosecurity system therefore depends largely on the feedback between these activities and diagnostics. Australian scientists will train Thai scientists in diagnostics and surveillance to provide the Thai DOA with skills that will aid in the development of a Thai Diagnostic Network. The skills will be taught using a range of pests, including some which have particular biosecurity importance for both Australia and Thailand such as citrus canker, potato viruses and fruit flies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Development of molecular markers for rapid diagnosis of phosphine resistance in insects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart failure (HF) affects approximately 23 million individuals worldwide and this number is increasing, due to an aging and growing population. Early detection of HF is crucial in the management of this debilitating disease. Current diagnostic methods for HF rely heavily on clinical imaging techniques and blood analysis, which makes them less than ideal for population-based screening purposes. Studies focusing on developing novel biomarkers for HF have utilized various techniques and biological fluids, including urine and saliva. Promising results from these studies imply that these body fluids can be used in evaluating the clinical manifestation of HF and will one day be integrated into a clinical workflow and facilitate HF management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. OBJECTIVE The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. METHODS Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. RESULTS All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. LIMITATIONS This PA protocol consisted of controlled activity trials. CONCLUSIONS Accelerometers provide valid and reliable measures of PA intensity among youth with CP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Sedentary behavior is continuing to emerge as an important target for health promotion. The purpose of this study was to determine the validity of a self-report use of time recall tool, the Multimedia Activity Recall for Children and Adults (MARCA) in estimating time spent sitting/lying, compared with a device-based measure. METHODS Fifty-eight participants (48% female, [mean±standard deviation] 28±7.4 years of age, 23.9±3.05 kg/m2) wore an activPAL device for 24-h and the following day completed the MARCA. Pearson correlation coefficients (r) were used to analyse convergent validity of the adult MARCA compared with activPAL estimates of total sitting/lying time. Agreement was examined using Bland-Altman plots. RESULTS According to activPAL estimates, participants spent 10.4 hr/day [standard deviation (SD)=2.06] sitting or lying down while awake. The correlation between MARCA and activPAL estimates of total sit/lie time was r=0.77 (95% confidence interval = 0.64-0.86; p<0.001). Bland-Altman analyses revealed a mean bias of +0.59 hr/day with moderately wide limits of agreement (-2.35 hours to +3.53 hr/day). CONCLUSIONS This study found a moderate to strong agreement between the adult MARCA and the activPAL, suggesting that the MARCA is an appropriate tool for the measurement of time spent sitting or lying down in an adult population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Based on self-reported measures, sedentary time has been associated with chronic disease and mortality. This study examined the validity of the wrist-worn GENEactiv accelerometer for measuring sedentary time (i.e. sitting and lying) by posture classification, during waking hours in free living adults. DESIGN Fifty-seven participants (age=18-55 years 52% male) were recruited using convenience sampling from a large metropolitan Australian university. METHODS Participants wore a GENEActiv accelerometer on their non-dominant wrist and an activPAL device attached to their right thigh for 24-h (00:00 to 23:59:59). Pearson's Correlation Coefficient was used to examine the convergent validity of the GENEActiv and the activPAL for estimating total sedentary time during waking hours. Agreement was illustrated using Bland and Altman plots, and intra-individual agreement for posture was assessed with the Kappa statistic. RESULTS Estimates of average total sedentary time over 24-h were 623 (SD 103) min/day from the GENEActiv, and 626 (SD 123) min/day from the activPAL, with an Intraclass Correlation Coefficient of 0.80 (95% confidence intervals 0.68-0.88). Bland and Altman plots showed slight underestimation of mean total sedentary time for GENEActiv relative to activPAL (mean difference: -3.44min/day), with moderate limits of agreement (-144 to 137min/day). Mean Kappa for posture was 0.53 (SD 0.12), indicating moderate agreement for this sample at the individual level. CONCLUSIONS The estimation of sedentary time by posture classification of the wrist-worn GENEActiv accelerometer was comparable to the activPAL. The GENEActiv may provide an alternative, easy to wear device based measure for descriptive estimates of sedentary time in population samples

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Sedentary behaviour is associated with several deleterious health consequences. Although device-based measures of sedentary time are available, they are costly and do not provide a measure of domain specific sedentary time. High quality self-report measures are necessary to accurately capture domain specific sedentary time, and to provide an alternative to devices when cost is an issue. In this study, the Past-day Adults’ Sedentary Time (PAST) questionnaire, previously shown to have acceptable validity and reliability in a sample of breast cancer survivors, was modified for a university sample and validity of the modified questionnaire was examined compared with activPAL. Methods Participants (n = 58, age = 18–55 years, 48% female, 66% students) were recruited from the University of Queensland (students and staff). They answered the PAST questionnaire, which asked about time spent sitting or lying down for work, study, travel, television viewing, leisure-time computer use, reading, eating, socialising and other purposes, during the previous day. Time reported for these questions was summed to provide a measure of total sedentary time. Participants also wore an activPAL device for the full day prior to completing the questionnaire and recorded their wake and sleep times in an activity log. Total waking sedentary time derived from the activPAL was used as the criterion measure. Correlation (Pearson's r) and agreement (Bland–Altman plots) between PAST and activPAL sedentary time were examined. Results Participants were sedentary (activPAL-determined) for approximately 66% of waking hours. The correlation between PAST and activPAL sedentary time for the whole sample was r = 0.50 [95% confidence interval (CI) = 0.28–0.67]; and higher for non-students (r = 0.63, 95% CI = 0.26–0.84) than students (r = 0.46, 95% CI = 0.16–0.68). Bland–Altman plots revealed that the mean difference between the two measures was 19 min although limits of agreement were wide (95% limits of agreement −4.1 to 4.7 h). Discussion The PAST questionnaire provides an acceptable measure of sedentary time in this population, which included students and adults with high workplace sitting. These findings support earlier research that questionnaires employing past-day recall of sedentary time provide a viable alternative to existing sedentary behaviour questionnaires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

- Objectives To develop and test a valid and reliable assessment of wheelchair skills for individuals with spinal cord injuries (SCI); the Queensland Evaluation of Wheelchair Skills (QEWS). - Setting Hospital, Australia. - Methods Phase 1: Four Delphi panel rounds with clinical experts were used to develop the QEWS. Phase 2: Intra-rater and inter-rater reliability of the QEWS items were examined in 100 people with SCI. Phase 3a: Concurrent validity was investigated by examining the association between QEWS total scores and physiotherapists’ global ratings of wheelchair skill performance. Phase 3b: Construct validity was tested in 20 people with recent SCI by examining change in QEWS total scores between when they first mobilised in a wheelchair and scores obtained 10 weeks later. - Results Phase 1: The QEWS was developed. Phase 2: The intra-class correlation coefficients reflecting the intra-rater reliability and the inter-rater reliability for the QEWS total score were 1.00 and 0.98, with scores being within one point of each other 96 and 91% of the time, respectively. Phase 3a: The QEWS total scores were comparable with the global rating of wheelchair skill performance (r2=0.93). Phase 3b: The QEWS scores changed by a median (interquartile range (IQR)) of 4 (1 to 6) points over the 10-week period following first wheelchair mobilisation. - Conclusion The QEWS is a valid and reliable tool for measuring wheelchair skills in individuals with SCI. The QEWS is efficient and practical to administer and does not require specialised equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stored product beetles that are resistant to the fumigant pesticide phosphine (hydrogen phosphide) gas have been reported for more than 40 years in many places worldwide. Traditionally, determination of phosphine resistance in stored product beetles is based on a discriminating dose bioassay that can take up to two weeks to evaluate. We developed a diagnostic cleaved amplified polymorphic sequence method, CAPS, to detect individuals with alleles for strong resistance to phosphine in populations of the red flour beetle, Tribolium castaneum, and the lesser grain borer, Rhyzopertha dominica, according to a single nucleotide mutation in the dihydrolipoamide dehydrogenase (DLD) gene. We initially isolated and sequenced the DLD genes from susceptible and strongly resistant populations of both species. The corresponding amino acid sequences were then deduced. A single amino acid mutation in DLD in populations of T.castaneum and R.dominica with strong resistance was identified as P45S in T.castaneum and P49S in R.dominica, both collected from northern Oklahoma, USA. PCR products containing these mutations were digested by the restriction enzymes MboI and BstNI, which revealed presence or absence, respectively of the resistant (R) allele and allowed inference of genotypes with that allele. Seven populations of T.castaneum from Kansas were subjected to discriminating dose bioassays for the weak and strong resistance phenotypes. Application of CAPS to these seven populations confirmed the R allele was in high frequency in the strongly resistant populations, and was absent or at a lower frequency in populations with weak resistance, which suggests that these populations with a low frequency of the R allele have the potential for selection of the strong resistance phenotype. CAPS markers for strong phosphine resistance will help to detect and confirm resistant beetles and can facilitate resistance management actions against a given pest population.