979 resultados para Detection Limit


Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: The epithelial sodium channel (ENaC) is composed of three homologous subunits: alpha, beta, and gamma. Mutations in the Scnn1b and Scnn1g genes, which encode the beta and the gamma subunits of ENaC, cause a severe form of hypertension (Liddle syndrome). The contribution of genetic variants within the Scnn1a gene, which codes for the alpha subunit, has not been investigated. METHODS: We screened for mutations in the COOH termini of the alpha and beta subunits of ENaC. Blood from 184 individuals from 31 families participating in a study on the genetics of hypertension were analyzed. Exons 13 of Scnn1a and Scnn1b, which encode the second transmembrane segment and the COOH termini of alpha- and beta-ENaC, respectively, were amplified from pooled DNA samples of members of each family by PCR. Constant denaturant capillary electrophoresis (CDCE) was used to detect mutations in PCR products of the pooled DNA samples. RESULTS: The detection limit of CDCE for ENaC variants was 1%, indicating that all members of any family or up to 100 individuals can be analyzed in one CDCE run. CDCE profiles of the COOH terminus of alpha-ENaC in pooled family members showed that the 31 families belonged to four groups and identified families with genetic variants. Using this approach, we analyzed 31 rather than 184 samples. Individual CDCE analysis of members from families with different pooled CDCE profiles revealed five genotypes containing 1853G-->T and 1987A-->G polymorphisms. The presence of the mutations was confirmed by DNA sequencing. For the COOH terminus of beta-ENaC, only one family showed a different CDCE profile. Two members of this family (n = 5) were heterozygous at 1781C-->T (T594M). CONCLUSION: CDCE rapidly detects point mutations in these candidate disease genes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Uimaveden klooridesinfioinnissa syntyy sivutuotteena haihtuvia ja haitallisia halogeeniyhdisteitä, kuten trihalometaaneja ja triklooriamiinia, jotka voivat heikentää allas-tilan sisäilman laatua merkittävästi. Tämän tutkimuksen tavoitteena oli kartoittaa näiden desinfioinnin sivutuotteiden pitoisuuksia suomalaisissa uimahalleissa sekä selvittää epäpuhtauksien kulkeutumista allastiloissa. Lisäksi pyrittiin löytämään merkittävimmät veden laatu- ja käsittelyparametrit sekä ilmanvaihtotekniset tekijät, jotka vaikuttavat vedestä haihtuvien epäpuhtauksien pitoisuuksiin hallitiloissa. Mittaukset tehtiin kymmenessä eri puolilla Suomea sijaitsevassa uimahallissa. Mittausten perusteella havaittiin, että allastilojen kloroformipitoisuudet vaihtelivat välillä 8,9-84,0 ¿g/m3. Terapia-allasostoilta mitatut pitoisuudet olivat pääallastiloista mitattuja pitoisuuksia suurempia ja aamulla mitattu pitoisuus alhaisempi kuin illalla mitattu. Lisäksi ilmastoiduista valvomoista mitatut pitoisuudet olivat merkittävästi allastilojen pitoisuuksia pienempiä. Triklooriamiininäytteistä suurin osa oli alle määritysrajan. Sisäilman kloroformipitoisuuden havaittiin korreloivan veden lämpötilan sekä ilman kosteuden kanssa. Triklooriamiinille tilastollista analyysiä ei voitu tehdä mm. määritys-rajan alle jääneiden näytteiden suuren osuuden vuoksi. Teknisten kyselyiden ja ilmanvaihtomittausten perusteella todettiin, että uimahallien ilmanvaihto toimii lämmitystarpeen vuoksi sekoittavana ja epäpuhtauksien leviämistä allastilassa ei voida käytännössä katsoen estää. Ilman virtausnopeudet pääaltaiden reunoilla olivat pieniä ja ilman virtauskenttien ei todettu vaikuttavan epäpuhtauksien kulkeutumiseen allastiloissa. Mittauskohteiden vähyydestä ja vedenkäsittelyn hallikohtaisista erityispiirteistä johtuen luotettavia johtopäätöksiä vedenkäsittelymenetelmien vaikutuksesta allasveden ja allastilan ilman laatuun ei pystytty tekemään.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Niemann-Pick type C (NP-C) is a rare progressive neurodegenerative lipid storage disorder with heterogeneous clinical presentation and challenging diagnostic procedures. Recently oxysterols have been reported to be specific biomarkers for NP-C but knowledge on the intra-individual variation and on reference intervals in children and adolescents are lacking. METHODS: We established a LC-MS/MS assay to measure Cholestane-3β, 5α, 6β-triol (C-triol) and 7-Ketocholesterol (7-KC) following Steglich esterification. To assess reference intervals and intra-individual variation we determined oxysterols in 148 children and adolescents from 0 to 18 years and repeat measurements in 19 of them. RESULTS: The reported method is linear (r>0.99), sensitive (detection limit of 0.03 ng/mL [0.07 nM] for C-triol, and 0.54 ng/mL [1.35 nM] for 7-KC) and precise, with an intra-day imprecision of 4.8% and 4.1%, and an inter-day imprecision of 7.0% and 11.0% for C-triol (28 ng/ml, 67 nM) and 7-KC (32 ng/ml, 80 nM), respectively. Recoveries for 7-KC and C-triol range between 93% and 107%. The upper reference limit obtained for C-triol is 40.4 ng/mL (95% CI: 26.4-61.7 ng/mL, 96.0 nM, 95% CI: 62.8-146.7 nM) and 75.0 ng/mL for 7-KC (95% CI: 55.5-102.5 ng/mL, 187.2 nM, 95% CI: 138.53-255.8 nM), with no age or gender dependency. Both oxysterols have a broad intra-individual variation of 46%±23% for C-triol and 52%±29% for 7-KC. Nevertheless, all Niemann-Pick patients showed increased C-triol levels including Niemann-Pick type A and B patients. CONCLUSIONS: The LC-MS/MS assay is a robust assay to quantify C-triol and 7-KC in plasma with well documented reference intervals in children and adolescents to screen for NP-C in the pediatric population. In addition our results suggest that especially the C-triol is a biomarker for all three Niemann-Pick diseases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Insulin determination in blood sampled during post-mortem investigation has been repeatedly asserted as being of little diagnostic value due to the rapid occurrence of decompositional changes and blood haemolysis. In this study, we assessed the feasibility of insulin determination in post-mortem serum, vitreous humour, bile, and cerebrospinal and pericardial fluids in one case of fatal insulin self-administration and a series of 40 control cases (diabetics and non-diabetics) using a chemiluminescence enzyme immunoassay. In the case of suicide by insulin self-administration, insulin concentrations in pericardial fluid and bile were higher than blood clinical reference values, though lower than post-mortem serum concentration. Insulin concentrations in vitreous (11.50 mU/L) and cerebrospinal fluid (17.30 mU/L) were lower than blood clinical reference values. Vitreous insulin concentrations in non-diabetic control cases were lower than the estimated detection limit of the method. These preliminary results tend to confirm the usefulness of insulin determination in vitreous humour in situations of suspected fatal insulin administration. Additional findings pertaining to insulin determination in bile, pericardial, and cerebrospinal fluid would suggest that analysis performed in post-mortem serum and injection sites could be complemented, in individual cases, by investigations carried out in alternative biological fluids. Lastly, these results would indicate that analysis with chemiluminescence enzyme immunoassay may provide suitable data, similar to analysis with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and immunoradiometric assay, to support the hypothesis of insulin overdose. Copyright © 2015 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The CORNISH project is the highest resolution radio continuum survey of the Galactic plane to date. It is the 5 GHz radio continuum part of a series of multi-wavelength surveys that focus on the northern GLIMPSE region (10° < l < 65°), observed by the Spitzer satellite in the mid-infrared. Observations with the Very Large Array in B and BnA configurations have yielded a 1.''5 resolution Stokes I map with a root mean square noise level better than 0.4 mJy beam 1. Here we describe the data-processing methods and data characteristics, and present a new, uniform catalog of compact radio emission. This includes an implementation of automatic deconvolution that provides much more reliable imaging than standard CLEANing. A rigorous investigation of the noise characteristics and reliability of source detection has been carried out. We show that the survey is optimized to detect emission on size scales up to 14'' and for unresolved sources the catalog is more than 90% complete at a flux density of 3.9 mJy. We have detected 3062 sources above a 7σ detection limit and present their ensemble properties. The catalog is highly reliable away from regions containing poorly sampled extended emission, which comprise less than 2% of the survey area. Imaging problems have been mitigated by down-weighting the shortest spacings and potential artifacts flagged via a rigorous manual inspection with reference to the Spitzer infrared data. We present images of the most common source types found: H II regions, planetary nebulae, and radio galaxies. The CORNISH data and catalog are available online at http://cornish.leeds.ac.uk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for the determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry, using the Zeeman effect background correction and the STPF conditions is proposed. The effect of iron (III) on the phosphorus signal was studied. It was verified, through the pyrolysis temperature curves, that iron (III) is an efficient chemical modifier, thermically stabilizing phosphorus up to 1400ºC. The phosphorus signal increases with the iron (III) concentration, but in the range, which corresponds to the usual concentrations of iron in the sample solutions, the increase is small. Phosphorus was determined in three standard reference materials, after its dissolution in a mixture of hydrochloric and perchloric acids in a PTFE bomb. The agreement with the certified concentration values was excellent. Iron (III) was added to the reference analytical solutions prepared in the blank of the dissolution, while the sample solutions were measured directly, since they already contained the modifier. The detection limit (k = 2) was 0.0042% of phosphorus in the steel sample.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple flow cell for potentiometric detection is described. It was assembled by making use of two perspex pieces fixed together by means of four screws, and allow the connection of plane membrane conventional electrodes to flow system. Details about its construction are presented. The device performance was evaluated by making use of a cyanide ion-selective electrode. The relative standard deviation was about 0.5% with a detection limit of 8.0 x 10-6 mol CN- dm-3. Under experimental conditions, the linear range was 10-5 to10-2 mol dm-3.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A flow injection (FI) spectrophotometric procedure is proposed for the determination of vitamin B6 (pyridoxine hydrochloride) in pharmaceutical preparations. Powdered samples containing from 2.5 to 4.5 mg, were previously dissolved in 0.1 mol L-1 phosphate buffer solution (pH 7.0) and a volume of 500 muL was injected directly into a carrier stream consisting of this same phosphate buffer solution, flowing at 4.4 mL min-1. The stable blue indophenol dye produced in the oxidation of pyridoxine hydrochloride by potassium hexacyanoferrate(III) and N,N-diethyl-p-phenylenediamine solution was directly measured at 684 nm. Vitamin B6 was determined in five pharmaceutical preparations in the 0.5 to 6.0 mg L-1 concentration range (calibration graph: A= -0.00499 + 0.11963 C; r= 0.9991, where A is the absorbance and C is the vitamin B6 concentration in mg L-1), with a detection limit of 0.02 mg L-1 (3 Sblank/slope). The recovery of this vitamin from three samples ranged from 97.5 to 103.3 %. The analytical frequency was 62 h-1 and r.s.d. were less than 2% for solutions containing 1.0 and 3.0 mg L-1 vitamin B6 (n= 10). The results obtained for the determination of vitamin B6 in commercial formulations were in good agreement with those obtained by a spectrophotometric procedure (r=0.9997) and also with the label values (r= 0.9998).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Little is known about the amount of water and ash in brazilian foodstuffs and plants. The relationships between fresh, dry and ash weight were determined in 40 different biological samples. It could be an important tool when one studies biological material containing low concentration of the chemical elements. This study address to determine these relationships and to provide the amount of biological material that one needs to collect. It aims to supply information that could be used to improve the detection limit, precision and accuracy of the analytical methodology utilized.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a system for electrochemical hydride generation using flow-injection and atomic absorption spectrometry to determine selenium in biological materials. The electrolytic cell was constructed by assembling two reservoirs, one for the sample and the other for the electrolytic solution separated by a Nafion membrane. Each compartment had a Pt electrode. The sample and electrolyte flow-rates, acidic media, and applied current were adjusted to attain the best analytical performance and ensure the membrane lifetime. The atomisation system used a T quartz tube in an air-LPG flame. The composition of the flame, the observation height, and the argon flow rate used to carry the hydrides were critically investigated. The system allowed to perform thirty determinations per hour with a detection limit of 10 mug L-1 of Se. Relative standard deviations were in general lower than 1.5% for a solution containing 20.0 and 34.0 mug L-1 of Se in a typical sample digest. Accuracy was assessed analysing the certified materials: rice flour (NIST-1568) from National Institute of Standard and Technology and dried fish (MA-A-2), whole animal blood (A-2/1974) from the International Atomic Energy Agency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple and low cost flow cell is proposed for measurements by solid-phase spectrophotometry employing a conventional spectrophotometer. The flow cell geometry allows the employment of a large amount of the solid support without causing both excessive attenuation of the radiation beam and increasing of the back-pressure. The adaptation of the flow cell in the optical path of the spectrophotometer in order to increase the precision is discussed. The flow cell characteristics were demonstrated by measurements of Co(II), employing 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18 bonded silica as solid support. The apparent molar absorptivity and coefficient of variation were estimated as 1.86 x 10(5) L mol-1 cm-1 and 1.4 % (n=15). A sample throughput of 40 determinations per hour and a detection limit of 15 mug L-1 (99.7 % confidence level) were achieved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present work proposes the application of the 4-Hidroxy-3-(2-hydroxynaphtylazo)-benzenesulphonic acid (C.I. 15670), Alizarine Violet N (AVN), as a reagent for direct aluminium determination using molecular absorption spectrophotometry in the presence of tensoatives. Al(III) cation reacts with AVN in pH 9.4, forming a red complex, stable for at least 24 hours, with absorption minimum at 607nm and, against a reagent blank, (epsiloncomplex - epsilonreagent) = -2.71x10(4) L.mol-1.cm-1. The reaction occurs in the presence of a Triton-X100 and CTAB tensoatives mixture, in the presence of EDTA. Al(III) determination is possible in the linear range of 50 up to 400ng.mL-1, with a detection limit of 41 ng.mL-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A flow injection spectrophotometric method was developed for determining aspartame in sweeteners. Sample was dissolved in water and 250 µL of the solution was injected into a carrier stream of 5.0 x 10-5 mol L-1 sodium borate solution. The sample flowed through a column (14 cm x 2.0 mm) packed with Zn3(PO4)2 immobilized in a polymeric matrix of polyester resin and Zn(II) ions were released from the solid-phase reactor by formation of the Zn(II)-aspartame complex. The mixture merged with a stream of borate buffer solution (pH 9.0) containing 0.030 % (m/v) alizarin red S and the Zn(II)-alizarin red complex formed was measured spectrophotometrically at 540 nm. The calibration graph for aspartame was linear in the concentration range from 10 to 80 µg mL-1 with a detection limit of 4 µg mL-1 of aspartame. The RSD was 0.3 % for a solution containing 40 µg mL-1 aspartame (n = 10) and seventy results were obtained per hour. The proposed method was applied for determining aspartame in commercial sweeteners.