944 resultados para Classificació AMS::51 Geometry
Resumo:
Let $\pi : \widetilde C \to C$ be an unramified double covering of irreducible smooth curves and let $P$ be the attached Prym variety. We prove the scheme-theoretic theta-dual equalities in the Prym variety $T(\widetilde C)=V^2$ and $T(V^2)=\widetilde C$, where $V^2$ is the Brill-Noether locus of $P$ associated to $\pi$ considered by Welters. As an application we prove a Torelli theorem analogous to the fact that the symmetric product $D^{(g)}$ of a curve $D$ of genus $g$ determines the curve.
Resumo:
AIMS: Published incidences of acute mountain sickness (AMS) vary widely. Reasons for this variation, and predictive factors of AMS, are not well understood. We aimed to identify predictive factors that are associated with the occurrence of AMS, and to test the hypothesis that study design is an independent predictive factor of AMS incidence. We did a systematic search (Medline, bibliographies) for relevant articles in English or French, up to April 28, 2013. Studies of any design reporting on AMS incidence in humans without prophylaxis were selected. Data on incidence and potential predictive factors were extracted by two reviewers and crosschecked by four reviewers. Associations between predictive factors and AMS incidence were sought through bivariate and multivariate analyses for different study designs separately. Association between AMS incidence and study design was assessed using multiple linear regression. RESULTS: We extracted data from 53,603 subjects from 34 randomized controlled trials, 44 cohort studies, and 33 cross-sectional studies. In randomized trials, the median of AMS incidences without prophylaxis was 60% (range, 16%-100%); mode of ascent and population were significantly associated with AMS incidence. In cohort studies, the median of AMS incidences was 51% (0%-100%); geographical location was significantly associated with AMS incidence. In cross-sectional studies, the median of AMS incidences was 32% (0%-68%); mode of ascent and maximum altitude were significantly associated with AMS incidence. In a multivariate analysis, study design (p=0.012), mode of ascent (p=0.003), maximum altitude (p<0.001), population (p=0.002), and geographical location (p<0.001) were significantly associated with AMS incidence. Age, sex, speed of ascent, duration of exposure, or history of AMS were inconsistently reported and therefore not further analyzed. CONCLUSIONS: Reported incidences and identifiable predictive factors of AMS depend on study design.
Resumo:
Studies regarding the field of this work aim to substitute industrial mechanical conveyors with pneumatic conveyors to overcome the disadvantages in solids flow regulation and risks posed to production and health. The experimental part of this work examines how the granular material properties, fluidizing airflow rate, equipment geometry, and pressures along the pipes affect the mass flow rate through the system. The results are compared with those obtained from previous experiments conducted with alumina. Experiments were carried out with a pilot scale downer-riser system at Outotec Research Center Frankfurt. Granular materi-als used in this work are named as sand, ilmenite, iron ore 1 and iron ore 2.
Resumo:
La solució principal que es dóna en aquest projecte és el desenvolupament d'una aplicació web que permeti a l'usuari poder gestionar les categories i categoritzar les converses d'un xat, on totes les converses quedaran registrades i categoritzades per poder fer un anàlisi posterior.
Resumo:
El projecte que es desenvolupa té per objectiu optimitzar el procediment que utilitzen els professionals mèdics per a elaborar el diagnòstic de les patologies que pateixen els pacients. Els criteris que s'optimitzen són variables, com ara minimitzar el cost de les exploracions necessàries i maximitzar l'eficiència, sempre a partir dels símptomes que acusi el pacient. Com a estratègia per a resoldre aquest problema s'utilitzen els arbres de classificació.
Resumo:
The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.
Resumo:
Aquest programari enmarca diversos algorimes supervisats, que extreuen informació devaris fitxers, i diversos agents classificadors que la transporten a un agent Manager.Finalment, aquest agent Manager computa tota aquesta informació rebuda per predir diferents valors de diverses instàncies aleatòries introduïdes per l'usuari.
Resumo:
Soitinnus: Piano.
Resumo:
Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finflo, which is a Navier-Stokes solver. All the cases are modeled with the Chien's k – έ- turbulence model, and selected cases are modeled also with the k – ώ-SST turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements. When comparing the computational results to the measured results, it is evident that the k – ώ-SST turbulence model predicts the flow fields better. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher efficiency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller efficiency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency, the increment being 1...3 percentage points, when compared to the vaneless unpinched geometry. The measurement results confirm that the pinch is beneficial to the performance of the compressor. The flow fields are more uniform with the pinched cases, and the slow flow regions are smaller. The peak efficiency is approximately 2 percentage points and the design point efficiency approximately 4 percentage points higher with the pinched geometries than with the un- pinched geometry. According to the measurements, the two best geometries are the ones with the most pinch at the shroud, the case with the pinch only at the shroud being slightly better of the two. The vaned diffusers also have better efficiency than the vaneless unpinched geometries. However, the pinched cases have even better efficiencies. The vaned diffusers narrow the operating range considerably, whilst the pinch has no significant effect on the operating range.
Resumo:
Digitoitu 13. 8. 2008.
Resumo:
Digitoitu 13. 8. 2008.
Resumo:
Gutenberg-lehti ilmestyi vuosina 1893-1915. Se oli perustettu ammattilehdeksi ja yhdyssiteeksi Suomen kirjanpainajille sekä äänenkannattajaksi Suomen kirjaltajaliitolle.
Resumo:
In this thesis, a computer software for defining the geometry for a centrifugal compressor impeller is designed and implemented. The project is done under the supervision of Laboratory of Fluid Dynamics in Lappeenranta University of Technology. This thesis is similar to the thesis written by Tomi Putus (2009) in which a centrifugal compressor impeller flow channel is researched and commonly used design practices are reviewed. Putus wrote a computer software which can be used to define impeller’s three-dimensional geometry based on the basic geometrical dimensions given by a preliminary design. The software designed in this thesis is almost similar but it uses a different programming language (C++) and a different way to define the shape of the impeller meridional projection.