937 resultados para false positive result


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Interferences with the Olympus immunoturbidimetric assay for ferritin have been reported because the antibodies used in the immunoassay are derived from rabbits. Rabbits are familiar pets known to be a risk factor for developing heterophilic (or interfering) antibodies. This report shows how the current Olympus Ferritin assay has been improved to eliminate the interference from heterophilic antibodies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To develop a provisional definition for the evaluation of response to therapy in juvenile dermatomyositis (DM) based on the Paediatric Rheumatology International Trials Organisation juvenile DM core set of variables. METHODS: Thirty-seven experienced pediatric rheumatologists from 27 countries achieved consensus on 128 difficult patient profiles as clinically improved or not improved using a stepwise approach (patient's rating, statistical analysis, definition selection). Using the physicians' consensus ratings as the "gold standard measure," chi-square, sensitivity, specificity, false-positive and-negative rates, area under the receiver operating characteristic curve, and kappa agreement for candidate definitions of improvement were calculated. Definitions with kappa values >0.8 were multiplied by the face validity score to select the top definitions. RESULTS: The top definition of improvement was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 1 of the remaining worsening by more than 30%, which cannot be muscle strength. The second-highest scoring definition was at least 20% improvement from baseline in 3 of 6 core set variables with no more than 2 of the remaining worsening by more than 25%, which cannot be muscle strength (definition P1 selected by the International Myositis Assessment and Clinical Studies group). The third is similar to the second with the maximum amount of worsening set to 30%. This indicates convergent validity of the process. CONCLUSION: We propose a provisional data-driven definition of improvement that reflects well the consensus rating of experienced clinicians, which incorporates clinically meaningful change in core set variables in a composite end point for the evaluation of global response to therapy in juvenile DM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intraoperative examination of sentinel axillary lymph nodes can be done by imprint cytology, frozen section, or, most recently, by PCR-based amplification of a cytokeratin signal. Using this technique, benign epithelial inclusions, representing mammary tissue displaced along the milk line, will likely generate a positive PCR signal and lead to a false-positive diagnosis of metastatic disease. To better appreciate the incidence of ectopic epithelial inclusions in axillary lymph nodes, we have performed an autopsy study, examining on 100 μm step sections 3,904 lymph nodes obtained from 160 axillary dissections in 80 patients. The median number of lymph nodes per axilla was 23 (15, 6, and 1 in levels 1, 2, and 3, respectively). A total of 30,450 hematoxylin-eosin stained slides were examined, as well as 8,825 slides immunostained with pan-cytokeratin antibodies. Despite this meticulous work-up, not a single epithelial inclusion was found in this study, suggesting that the incidence of such inclusions is much lower than the assumed 5% reported in the literature.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In heart transplantation (HTx), acute antibody-mediated rejection (AMR) is infrequent but carries high mortality and increased risk of graft vasculopathy. The diagnosis requires evidence of acute graft dysfunction, capillary lesions on endomyocardial biopsy (EMB), and immunopathological criteria of antibodymediated injury. Multiple markers of antibody-mediated injuries have been proposed, but there is ample debate on their usefulness. In kidney transplantation, C4d deposition in peritubular capillaries is a reliable marker of alloantibody-dependant graft injury. In this study, we prospectively screened all EMBs for C4d and CD68 in new HTx recipients, and correlated pathological fi ndings with immunological evidence of donor-specifi c antibodies (DSA) and graft dysfunction. Methods Between Nov 05 and Aug 08, we had 22 HTx, and 17 cases were analysed. All recipients received polyclonal rabbit anti-thymocytes globulin, calcineurin inhibitors, mycophenolate mofetil, and corticosteroids (weaning in 6 -12 months). They had EMB every 1-2 weeks in the fi rst 3 months, and then monthly for 9 months. C4d and CD 68 were assessed by immunochemistry. Echocardiography and DSA assessment or crossmatch (early phase) were realised if C4d or CD68 staining was positive. Results There was 1 early and 1 late AMR. Table 1 C4d and CD68 positive, at least 1 EMB 6 / 17; 35% 1 treated C4d and CD68 positive, at least 2 consecutive EMBs 3 / 17; 17.5% 1 treated C4d and CD68 positive, and graft dysfunction 1 / 17; 6% 1 treated C4d and CD68 positive, with DSA and crossmatch + 1 / 17; 6% 1 treated Table 2 C4d and CD68 positive, at least 1 EMB 1 / 17; 6% 1 treated C4d and CD68 positive, at least 2 consecutive EMBs 1 /17; 6% 1 treated C4d and CD68 positive and graft dysfunction 1 / 17; 6% 1 treated C4d and CD68 positive, and + DSA 1 / 17; 6% 1 treated Conclusion In this single-center experience, C4d / CD68 positive staining was frequent in the early phase and raised the question of false positive cases of AMR. However, these markers showed high specifi city for the diagnosis of AMR in the late phase. Of course these data need to be confi rmed in larger multi-center studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Autofluorescence bronchoscopy (AFB) is a highly sensitive tool for the detection of early bronchial cancers. However, its specificity remains limited due to primarily false positive results induced by hyperplasia, metaplasia and inflammation. We have investigated the potential of blue-violet backscattered light to eliminate false positive results during AFB in a clinical pilot study. METHODS: The diagnostic autofluorescence endoscopy (DAFE) system was equipped with a variable band pass filter in the imaging detection path. The backscattering properties of normal and abnormal bronchial mucosae were assessed by computing the contrast between the two tissue types for blue-violet wavelengths ranging between 410 and 490 nm in 12 patients undergoing routine DAFE examination. In a second study including 6 patients we used a variable long pass (LP) filter to determine the spectral design of the emission filter dedicated to the detection of this blue-violet light with the DAFE system. RESULTS: (Pre-)neoplastic mucosa showed a clear wavelength dependence of the backscattering properties of blue-violet light while the reflectivity of normal, metaplastic and hyperplastic autofluorescence positive mucosa was wavelength independent. CONCLUSIONS: Our results showed that the detection of blue-violet light has the potential to reduce the number of false positive results in AFB. In addition we determined the spectral design of the emission filter dedicated to the detection of this blue-violet light with the DAFE system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. METHODS: This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. RESULTS: During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. CONCLUSIONS: This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to assess whether Neisseria meningitidis, Listeria monocytogenes, Streptococcus pneumoniae and Haemophilus influenzae can be identified using the polymerase chain reaction technique in the cerebrospinal fluid of severely decomposed bodies with known, noninfectious causes of death or whether postmortem changes can lead to false positive results and thus erroneous diagnostic information. Biochemical investigations, postmortem bacteriology and real-time polymerase chain reaction analysis in cerebrospinal fluid were performed in a series of medico-legal autopsies that included noninfectious causes of death with decomposition, bacterial meningitis without decomposition, bacterial meningitis with decomposition, low respiratory tract infections with decomposition and abdominal infections with decomposition. In noninfectious causes of death with decomposition, postmortem investigations failed to reveal results consistent with generalized inflammation or bacterial infections at the time of death. Real-time polymerase chain reaction analysis in cerebrospinal fluid did not identify the studied bacteria in any of these cases. The results of this study highlight the usefulness of molecular approaches in bacteriology as well as the use of alternative biological samples in postmortem biochemistry in order to obtain suitable information even in corpses with severe decompositional changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Studies assessing skin irritation to chemicals have traditionally used laboratory animals; however, such methods are questionable regarding their relevance for humans. New in vitro methods have been validated, such as the reconstructed human epidermis (RHE) model (Episkin®, Epiderm®). The comparison (accuracy) with in vivo results such as the 4-h human patch test (HPT) is 76% at best (Epiderm®). There is a need to develop an in vitro method that better simulates the anatomo-pathological changes encountered in vivo. To develop an in vitro method to determine skin irritation using human viable skin through histopathology, and compare the results of 4 tested substances to the main in vitro methods and in vivo animal method (Draize test). Human skin removed during surgery was dermatomed and mounted on an in vitro flow-through diffusion cell system. Ten chemicals with known non-irritant (heptylbutyrate, hexylsalicylate, butylmethacrylate, isoproturon, bentazon, DEHP and methylisothiazolinone (MI)) and irritant properties (folpet, 1-bromohexane and methylchloroisothiazolinone (MCI/MI)), a negative control (sodiumchloride) and a positive control (sodiumlaurylsulphate) were applied. The skin was exposed at least for 4h. Histopathology was performed to investigate irritation signs (spongiosis, necrosis, vacuolization). We obtained 100% accuracy with the HPT model; 75% with the RHE models and 50% with the Draize test for 4 tested substances. The coefficients of variation (CV) between our three test batches were <0.1, showing good reproducibility. Furthermore, we reported objectively histopathological irritation signs (irritation scale): strong (folpet), significant (1-bromohexane), slight (MCI/MI at 750/250ppm) and none (isoproturon, bentazon, DEHP and MI). This new in vitro test method presented effective results for the tested chemicals. It should be further validated using a greater number of substances; and tested in different laboratories in order to suitably evaluate reproducibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Since the first anti-doping tests in the 1960s, the analytical aspects of the testing remain challenging. The evolution of the analytical process in doping control is discussed in this paper with a particular emphasis on separation techniques, such as gas chromatography and liquid chromatography. These approaches are improving in parallel with the requirements of increasing sensitivity and selectivity for detecting prohibited substances in biological samples from athletes. Moreover, fast analyses are mandatory to deal with the growing number of doping control samples and the short response time required during particular sport events. Recent developments in mass spectrometry and the expansion of accurate mass determination has improved anti-doping strategies with the possibility of using elemental composition and isotope patterns for structural identification. These techniques must be able to distinguish equivocally between negative and suspicious samples with no false-negative or false-positive results. Therefore, high degree of reliability must be reached for the identification of major metabolites corresponding to suspected analytes. Along with current trends in pharmaceutical industry the analysis of proteins and peptides remains an important issue in doping control. Sophisticated analytical tools are still mandatory to improve their distinction from endogenous analogs. Finally, indirect approaches will be discussed in the context of anti-doping, in which recent advances are aimed to examine the biological response of a doping agent in a holistic way.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During a 3-year period, 848 patients were detected as carriers of methicillin-resistant Staphylococcus aureus (MRSA) by the Xpert MRSA assay (Cepheid). Among them, 108 patients (12.7 %) were colonized with strains showing methicillin-susceptible phenotypes and absence of the mecA gene, despite being positive with the rapid polymerase chain reaction (PCR) assay. DNA sequences of the staphylococcal cassette chromosome mec (SCCmec) insertion site of these "false-positive" strains was determined by direct sequencing of the genomic DNA. More than half (53.7 %) of the strains had DNA sequences unrelated to either SCC or SCCmec and one-third had DNA sequences related to non-mec SCC. Only 10.2 % of the strains carried sequences related to SCCmec, suggesting that a sequence containing the mecA gene was lost from an SCCmec. These findings differ from the general idea that all methicillin-susceptible S. aureus having positive Xpert MRSA assay results are essentially MRSA that lost the mecA gene.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A serological survey of hepatitis B virus (HBV) and hepatitis C virus (HCV) infections was carried out on a random sex- and age-stratified sample of 1006 individuals aged 25-64 years in the Seychelles islands. Anti-HBc and anti-HCV antibodies were detected using commercially available enzyme-linked immunosorbent assays (ELISA), followed by a Western blot assay in the case of a positive result for anti-HCV. The age-adjusted seroprevalence of anti-HBc antibodies was 8.0% (95% CI: 6.5-9.9%) and the percentage prevalence among males/females increased from 7.0/3.1 to 19.1/13.4 in the age groups 25-34 to 55-64 years, respectively. Two men and three women were positive for anti-HCV antibodies, with an age-adjusted seroprevalence of 0.34% (95% CI: 0.1-0.8%). Two out of these five subjects who were positive for anti-HCV also had anti-HBc antibodies. The seroprevalence of anti-HBc was significantly higher in unskilled workers, persons with low education, and heavy drinkers. The age-specific seroprevalence of anti-HBc in this population-based survey, which was conducted in 1994, was approximately three times lower than in a previous patient-based survey carried out in 1979. Although there are methodological differences between the two surveys, it is likely that the substantial decrease in anti-HBc prevalence during the last 15 years may be due to significant socioeconomic development and the systematic screening of blood donors since 1981. Because hepatitis C virus infections are serious and the cost of treatment is high, the fact that the prevalence of anti-HCV antibodies is at present low should not be an argument for not screening blood donors for anti-HCV and eliminating those who are positive.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The specificity of ethyl glucuronide (EtG) in hair as marker of alcohol consumption exceeds by far those of fatty acid ethyl esters. False positive cases are therefore very rare but not excluded as recent publications have shown. Especially, the use of plant extracts containing high percentages of ethanol can lead to EtG hair concentrations typically found in cases of chronic alcohol consumption. As proposed by Baumgartner et al., a nucleohilic substitution could most likely explain this phenomenon. Fresh and dried plants as well as commercial hair lotions based on plants extracts have been analysed for EtG presence or EtG formation. Methods: Urtica dioica, Plantago lanceolata, Cortex Quercus, Sempervivum, Armoracia rusticana, Juniperus communis, Brassica alba, Thymian vulgaris, Salvia officinalis, Majorana hortensis, Aloe vera, birch gingko and green tea leafs, ginger, lemon grass were extracted in water, water/ethanol (50/50) and ethanol (100%). The extracts as well as diluted hair lotions were measured by immunological test (Microgenics DRI® EtG assay) and by LC-MS/MS on Shimadzu Nexera UHPLC coupled with an AB Sciex 4500 QTrap. Results: EtG could not be detected in water extracts of all tested plants. However, DRI® EtG assay indicated the presence of EtG in 66% of the tested ethanolic plant extracts. That could only be confirmed by mass spectrometry in the cases of fresh thyme as well as in dried birch, oak and plantain extracts where EtG concentrations between of 0.25 and 2,09 mg/l were measured. In one hair lotion, the EtG concentration was 0,76 mg/l. Conclusion: Ethanolic plant extracts represents a non-negligible risk for false positive EtG hair tests, especially when applied as lotion without following washing out. The use of hair care products must therefore be evaluated at every hair sampling. In case of doubt, the product should be analysed by mass spectrometric methods since the presence of EtG can't be proven by use of the DRI® EtG assay, only. Our results support Baumgartner's assumption of a nucleophilic substitution in presence of ethanol because EtG was only measured in the ethanolic extracts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Continuous EEG (cEEG) is increasingly used to monitor brain function in neuro-ICU patients. However, its value in patients with coma after cardiac arrest (CA), particularly in the setting of therapeutic hypothermia (TH), is only beginning to be elucidated. The aim of this study was to examine whether cEEG performed during TH may predict outcome. METHODS: From April 2009 to April 2010, we prospectively studied 34 consecutive comatose patients treated with TH after CA who were monitored with cEEG, initiated during hypothermia and maintained after rewarming. EEG background reactivity to painful stimulation was tested. We analyzed the association between cEEG findings and neurologic outcome, assessed at 2 months with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). RESULTS: Continuous EEG recording was started 12 ± 6 hours after CA and lasted 30 ± 11 hours. Nonreactive cEEG background (12 of 15 (75%) among nonsurvivors versus none of 19 (0) survivors; P < 0.001) and prolonged discontinuous "burst-suppression" activity (11 of 15 (73%) versus none of 19; P < 0.001) were significantly associated with mortality. EEG seizures with absent background reactivity also differed significantly (seven of 15 (47%) versus none of 12 (0); P = 0.001). In patients with nonreactive background or seizures/epileptiform discharges on cEEG, no improvement was seen after TH. Nonreactive cEEG background during TH had a positive predictive value of 100% (95% confidence interval (CI), 74 to 100%) and a false-positive rate of 0 (95% CI, 0 to 18%) for mortality. All survivors had cEEG background reactivity, and the majority of them (14 (74%) of 19) had a favorable outcome (CPC 1 or 2). CONCLUSIONS: Continuous EEG monitoring showing a nonreactive or discontinuous background during TH is strongly associated with unfavorable outcome in patients with coma after CA. These data warrant larger studies to confirm the value of continuous EEG monitoring in predicting prognosis after CA and TH.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Chest pain can be caused by various conditions, with life-threatening cardiac disease being of greatest concern. Prediction scores to rule out coronary artery disease have been developed for use in emergency settings. We developed and validated a simple prediction rule for use in primary care. METHODS: We conducted a cross-sectional diagnostic study in 74 primary care practices in Germany. Primary care physicians recruited all consecutive patients who presented with chest pain (n = 1249) and recorded symptoms and findings for each patient (derivation cohort). An independent expert panel reviewed follow-up data obtained at six weeks and six months on symptoms, investigations, hospital admissions and medications to determine the presence or absence of coronary artery disease. Adjusted odds ratios of relevant variables were used to develop a prediction rule. We calculated measures of diagnostic accuracy for different cut-off values for the prediction scores using data derived from another prospective primary care study (validation cohort). RESULTS: The prediction rule contained five determinants (age/sex, known vascular disease, patient assumes pain is of cardiac origin, pain is worse during exercise, and pain is not reproducible by palpation), with the score ranging from 0 to 5 points. The area under the curve (receiver operating characteristic curve) was 0.87 (95% confidence interval [CI] 0.83-0.91) for the derivation cohort and 0.90 (95% CI 0.87-0.93) for the validation cohort. The best overall discrimination was with a cut-off value of 3 (positive result 3-5 points; negative result <or= 2 points), which had a sensitivity of 87.1% (95% CI 79.9%-94.2%) and a specificity of 80.8% (77.6%-83.9%). INTERPRETATION: The prediction rule for coronary artery disease in primary care proved to be robust in the validation cohort. It can help to rule out coronary artery disease in patients presenting with chest pain in primary care.