952 resultados para Secondary wastewater treatment
Nitrification of high strength ammonia wastewtaer treatment - process selection is the major factor.
Resumo:
Biological nitrogen removal via the nitrite pathway in wastewater treatment is very important in Saving the cost of aeration and as an electron donor for denitrification. Wastewater nitrification and nitrite accumulation were carried out in a biofilm airlift reactor with autotrophic nitrifying biofilm. The biofilm reactor showed almost complete nitrification and most of the oxidized ammonium was present as nitrite at the ammonium load of 1.5 to 3.5 kg N/m3.d. Nitrite accumulation was stably achieved by the selective inhibition of nitrite oxidizers with free ammonia and dissolved oxygen limitation. Stable 100% conversion to nitrite could also be achieved even under the absence of free ammonia inhibition on nitrite oxidizers. Batch ammonium oxidation and nitrite oxidation with nitrite accumulating nitrifying biofilm showed that nitrite Oxidation was completely inhibited when free ammonia is higher than 0.2 mg N/L. However, nitrite oxidation activity was recovered as soon as the free ammonia concentration was below the threshold level when dissolved oxygen concentration was not the limiting factor. Fluorescence in situ hybridization analysis of cryosectioned nitrite accumulating nitrifying biofilm showed that the β-subclass of Proteobacteria, where ammonia oxidizers belong, was distributed outside the biofilm whereas the α-subclass of Proteobacteria, where nitrite oxidizers belong, was found mainly in the inner part of the biofilm. It is likely that dissolved oxygen deficiency or limitation in the inner part of the nitrifying biofilm, where nitrite oxidizers exist, is responsible for the complete shut down of the nitrite oxidizers activity under the absence of free ammonia inhibition.
Resumo:
Wastewater from cork processing industry present high levels of organic and phenolic compounds, such as tannins, with a low biodegradability and a significant toxicity. These compounds are not readily removed by conventional municipal wastewater treatment, which is largely based on primary sedimentation followed by biological treatment. The purpose of this work is to study the biodegradability of different cork wastewater fractions, obtained through membrane separation, in order to assess its potential for biological treatment and having in view its valorisation through tannins recovery, which could be applied in other industries. Various ultrafiltration and nanofiltration membranes where used, with molecular weight cut-offs (MWCO) ranging from 0.125 to 91 kDa. The wastewater and the different permeated fractions were analyzed in terms of Total Organic Carbon (TOC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Total Phenols (TP), Tannins, Color, pH and Conductivity. Results for the wastewater shown that it is characterized by a high organic content (670.5-1056.8 mg TOC/L, 2285-2604 mg COD/L, 1000-1225 mg BOD/L), a relatively low biodegradability (0.35-0.38 for BODs/COD and 0.44-0.47 for BOD20/COD) and a high content of phenols (360-410 mg tannic acid/L) and tannins (250-270 mg tannic acid/L). The results for the wastewater fractions shown a general decrease on the pollutant content of permeates, and an increase of its biodegradability, with the decrease of the membrane MWCO applied. Particularly, the permeated fraction from the membrane MWCO of 3.8 kDa, presented a favourable index of biodegradability (0.8) and a minimized phenols toxicity that enables it to undergo a biological treatment and so, to be treated in a municipal wastewater treatment plant. Also, within the perspective of valorisation, the rejected fraction obtained through this membrane MWCO may have a significant potential for tannins recovery. Permeated fractions from membranes with MWCO lower than 3.8 kDa, presented a particularly significant decline of organic matter and phenols, enabling this permeates to be reused in the cork processing and so, representing an interesting perspective of zero discharge for the cork industry, with evident environmental and economic advantages. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Cork processing involves a boiling step to make the cork softer, which consumes a high volume of water and generates a wastewater with a high organic content, rich in tannins. An assessment of the final wastewater characteristics and of the boiling water composition along the boiling process was performed. The parameters studied were pH, color, total organic carbon (TOC), chemical and biochemical oxygen demands (COD, BOD5, BOD20), total suspended solids (TSS), total phenols and tannins (TP, TT). It was observed that the water solutes extraction power is significantly reduced for higher quantities of cork processed. Valid relationships between parameters were established not only envisaging wastewater characterization but also to provide an important tool for wastewater monitoring and for process control/optimization. Boiling water biodegradability presented decreasing values with the increase of cork processed and for the final wastewater its value is always lower than 0.5, indicating that these wastewaters are very difficult to treat by biological processes. The biodegradability was associated with the increase of tannin content that can rise up to 0.7 g/L. These compounds can be used by other industries when concentrated and the clarified wastewater can be reused, which is a potential asset in this wastewater treatment.
Resumo:
The present work aims at evaluating the efficiency of an organic polymer from vegetal source used as coagulant for treating different types of industrial effluents. This coagulant (Flox-QT) is obtained from the Black Acacia (Acacia mearnsii). The effluents studied were produced in petrochemical, leather, cork stoppers, metalworking, olive oil, glue, paint (printing), textile and paper industries. The parameters analyzed in the effluents before and after treatment were selected according to the type of wastewater and included pH, conductivity, apparent colour, turbidity, total suspended solids (TSS), chemical oxygen demand (COD) and some metals. The coagulant proved to be efficient for almost all effluents tested. The best results were obtained for the paper industry wastewater, with 91% removal of chemical oxygen demand and 95% of total suspended solids removal. The estimated cost of this treatment would be only 0.24 Euro per cubic meter of treated effluent, only regarding the price of the coagulant and the required dosage. The use of this coagulant is also adequate for the valorisation of the sludge obtained, which in this case could be recycled for paper production.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Hidráulica
Resumo:
A Mundotêxtil foi fundada em 1975 tendo iniciado a sua actividade na área comercial de produtos têxteis. Actualmente é o maior produtor nacional de atoalhados de felpo e emprega 575 colaboradores. Como resultado do seu crescimento e sobretudo da actividade de tingimento de fio e felpo, as necessidades de água são consideráveis e o volume de efluentes gerados nos processos industriais é cada vez maior a empresa avançou com a construção de uma estação de tratamento por lamas activadas, colocando-a em funcionamento em Setembro de 2004. Inicialmente surgiram dificuldades para a remoção da cor e da concentração da Carência Química de Oxigénio (CQO) de modo a cumprir os limites máximos de emissão permitidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98, de 1 de Agosto. Com a descarga de parte dos efluentes no SIDVA e a utilização de um coagulante adicionado ao reactor o tratamento passou a apresentar melhores resultados. O intuito deste trabalho é o de apresentar soluções de modo a optimizar o funcionamento do tratamento biológico da Mundotêxtil. A optimização pode começar na concepção dos produtos, pode incidir no processo de fabrico para além de poder ser efectuada no seio da estação de tratamento biológico. Foi efectuado um estudo do tratamento biológico por lamas activadas no Laboratório de Tecnologia Química Profª Doutora Lída de Vasconcelos, laboratório tecnológico do Instituto Superior de Engenharia do Porto (ISEP) que decorreu nos meses de Maio, Junho e Julho de 2010. O estudo laboratorial foi efectuado para três situações distintas: 1) tratamento do efluente bruto sem qualquer tipo de pré-tratamento (ensaios 1 a 3); 2) tratamento do efluente bruto submetido a pré-tratamento com coagulante Ambifloc BIO MD (ensaios 4 e 5) e 3) tratamento com adição de fungos ao tanque de arejamento (ensaio 6). Foram utilizadas duas instalações de tratamento alimentadas a partir do mesmo tanque de alimentação. Os dois sistemas eram idênticos, diferiram nos caudais de alimentação de efluente que foram alterados ao longo do estudo. O efluente a tratar foi fornecido pela empresa Mundotêxtil, sendo recolhido por diversas vezes ao longo dos ensaios. Este efluente foi retirado após o pré-tratamento da empresa, ou seja este efluente é o mesmo que alimenta o tratamento biológico da Mundotêxtil. Devido a este facto o efluente usado no estudo laboratorial teve uma variabilidade no período em que decorreu o estudo, nomeadamente em termos de concentração de CQO e cor. A relação entre a Carência Bioquímica (CBO5) e a CQO situouse entre 0,47 e 0,63 o que traduz que está dentro dos valores típicos para um efluente têxtil. Os melhores resultados globais de remoção de CQO foram obtidos no ensaio 5 e estiveram compreendidos entre 73,2% e 77,5% para o ensaio 5.1 e entre 62,9 e 73,2% para o ensaio 5.2. Neste ensaio foi utilizado o coagulante. Todos os valores de concentração de CQO obtidos nos efluentes dos decantadores para os ensaios 2, 5 e 6 são inferiores aos valores limite de descarga definidos nas normas de descarga no rio Ave e o Decreto-Lei 236/98. Os valores de concentração de Sólidos Suspensos Totais (SST), pH, fósforo, CBO5 e cor nos decantadores cumpriram os limites de descarga definidos nas normas de descarga no rio Ave e no Decreto-Lei nº 236/98 em todos os ensaios. Os parâmetros cinéticos obtidos para os ensaios com descorante são os que melhor se ajustam ao projecto de uma instalação de tratamento biológico por lamas activadas do efluente da Mundotêxtil. Os valores obtidos, após ajuste, são os seguintes: k=0,015 L/(mgSSV*d); Sn=12 mg/L; a=0,7982 kgO2/kgCBO5; b=0,0233 [kgO2/(kgSSV*d); y=0,2253 kgSSV/kgCBO5; kd=0,0036 kgSSV/(kgSSV*d. Com base nos parâmetros cinéticos obtiveram-se os seguintes resultados para o projecto de uma estação de tratamento biológico por lamas activadas: · Tempo de retenção hidráulica no reactor de 1,79 d, · Volume do reactor igual a 3643 m3 · Consumo de oxigénio no reactor de 604 kg/d · Razão de recirculação igual a 0,8 · Volume total do decantador secundário igual a 540 m3 · Diâmetro do decantador secundário igual a 15 m A quantidade de oxigénio necessário é baixa e o valor mais adequado deverá ser da ordem de 1200 kg/d. Também foi efectuada uma análise aos produtos químicos consumidos pela empresa na área das tinturarias com a finalidade de identificar as substâncias com uma maior influência potencial no funcionamento da Estação de Tratamento Biológico. O encolante CB, Cera Têxtil P Líquida, Perfemina P-12, Meropan DPE-P, Meropan BRE-P, Indimina STS e Benzym TEC são os produtos químicos que têm uma influência potencial mais significativa na qualidade dos efluentes. Devido ao facto das temperaturas do efluente alimentado ao tratamento biológico da Mundotêxtil oscilarem entre 35 ºC e 43ºC efectuou-se um estudo às necessidades de água quente das tinturarias e por outro lado à capacidade de aquecimento dos efluentes disponíveis. Actualmente a racionalização dos consumos de água é cada vez mais premente, por isso também é apresentado neste trabalho um estudo para a substituição das máquinas convencionais das tinturarias com uma relação de banho 1:10 por máquinas de banho curto (1:6,5). Verifica-se a redução de consumos de 40% de água, 52% de energia eléctrica, 35% de produtos químicos, 51% das necessidades de vapor e por consequência um aumento da produtividade. A empresa pode reduzir os consumos de água em cerca de 280.000 m3/ano. A utilização do pré-tratamento com o coagulante permitirá baixar a concentração da CQO e reduzir a cor à entrada do reactor tratamento biológico. Deste modo é possível manter um tratamento eficiente à saída do tratamento biológico nas situações de descarga de cores carregadas e carga orgânica elevada. Com este conjunto de soluções, quer sejam aplicadas na totalidade ou não, a empresa Mundotêxtil pode enfrentar o futuro com mais confiança podendo estar preparada para fazer face à escassez de água e custos cada vez maiores da energia. Por outro lado pode tratar os seus efluentes a custos menores. A substituição das máquinas de tingimento por máquinas com relação de banho mais baixa (banho curto) implica investimentos elevados mas estes investimentos são necessários não só por motivos ambientais mas também devido à grande competitividade dos mercados.
Resumo:
The market for emulsion polymers (latexes) is large and growing at the expense of other manufacturing processes that emit higher amounts of volatile organic solvents. The paint industry is not an exception and solvent-borne paints have been gradually substituted by aqueous paints. In their life-cycle, much of the aqueous paint used for architectural or decorative purposes will eventually be discharged into wastewater treatment facilities, where its polymeric nanoparticles (mainly acrylic and styrene-acrylic) can work as xenobiotics to the microbial communities present in activated sludge. It is well established that these materials are biocompatible at macroscopic scale. But is their behaviour the same at nanoscale? What happens to the polymeric nanoparticles during the activated sludge process? Do nanoparticles agregate and are discharged together with the sludge or remain in emulsion? How do microorganisms interact with these nanoparticles? Are nanoparticles degradated by them? Are they adsorbed? Are these nanoparticles toxic to the microbial community? To study the influence of these xenobiotics in the activated sludge process, an emulsion of cross-linked poly(butyl methacrylate) nanoparticles of ca. 50 nm diameter was produced and used as model compound. Activated sludge from a wastewater treatment plant was tested by the OCDE’s respiration inhibition test using several concentrations of PBMA nanoparticles. Particle aggregation was followed by Dynamic Light Scattering and microorganism surfaces were observed by Atomic Force Microscopy. Using sequential batch reactors (SBRs) and continuous reactors, both inoculated with activated sludge, the consumption of carbon, ammonia, nitrite and nitrate was monitored and compared, in the presence and absence of nanoparticles. No particles were detected in all treated waters by Dynamic Light Scattering. This can either mean that microorganisms can efficiently remove all polymer nanoparticles or that nanoparticles tend to aggregate and be naturally removed by precipitation. Nevertheless respiration inhibition tests demonstrated that microorganisms consume more oxygen in the presence of nanoparticles, which suggests a stress situation. It was also observed a slight decrease in the efficiency of nitrification in the presence of nanoparticles. AFM images showed that while the morphology of some organisms remained the same both in the presence and absence of nanoparticles, others assumed a rough surface with hilly like shapes of ca. 50 nm when exposed to nanoparticles. Nanoparticles are thus likely to be either incorporated or adsorbed at the surface of some organisms, increasing the overall respiration rate and decreasing nitrification efficiency. Thus, despite its biocompatibility at macroscopic scale, PBMA is likely to be no longer innocuous at nanoscale.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil Engenharia Sanitária
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia Química e Bioquímica pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
O tratamento das águas residuais domésticas surge com o intuito de degradar os poluentes presentes, para que as águas residuais tratadas não prejudiquem o ambiente nem a saúde pública. O presente trabalho teve como objetivo a conceção e o dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) na freguesia de Canelas com a finalidade de substituir a já existente e permitir a ampliação da área da rede de saneamento da freguesia. Foram considerados dois tipos de ETAR’s, compacta e convencional, para tratar águas residuais domésticas de aproxidamente 2000 habitantes, com um caudal médio de 400 m3/dia e um caudal de ponta de 1136,7 m3/dia. Das duas opções optou-se pela convencional uma vez que acarreta um menor investimento, no valor de 187 232 €, e se considera também mais adequada às características do efluente a tratar. O tratamento escolhido inclui inicialmente uma gradagem, com uma grade constituída por sete barras com um espaçamento de 20 mm entre elas, seguida de um tamisador rotativo com uma abertura de malha de 3 mm. Depois do tamisador, optou-se por um sistema de desarenação/desengorduramento com um volume do tanque de 3,95 m3 e um fluxo de ar de 17,9 m3/h. Na fase seguinte considerou-se um tratamento biológico por lamas ativadas em regime de arejamento prolongado num tanque de arejamento de volume igual a 245,8 m3 com um arejador submerso, seguindo-se um decantador secundário de volume 33,3 m3. Por último, escolheu-se um sistema de desinfeção por ultravioleta e, a montante do mesmo, um filtro rápido para eliminar pequenas partículas que o efluente ainda possa conter. Para a desinfeção foram consideradas duas secções com cinco módulos de duas lâmpadas cada, ou seja, vinte lâmpadas ultravioleta. Dos resíduos produzidos pelo tratamento da água residual, os gradados e as areias serão encaminhados para aterro, enquanto que as lamas serão enviadas para a ETAR das Termas de S.Vicente, para que sofram o tratamento adequado e sejam encaminhadas para o destinal final adequado (aplicação em solos agrícolas, compostagem ou em alternativa para aterro). No caso da ETAR covencional foi ainda avaliada a possível reutilização de um decantador da ETAR de Milhundos uma vez que esta se encontrava em fase de desativação. Desta avaliação, concluiu-se que não seria economicamente viável o seu reaproveitamento. Mestrado em Engenharia Química – Tecnologias de Proteção Ambiental Para além disso realizou-se também um levantamento dos principais problemas que ocorrem na maioria das ETAR’s e foram apresentadas as respetivas sugestões de resolução. A realização de um inquérito permititu concluir que os odores são o problema que mais causa incómodo à população.
Resumo:
A atividade humana e industrial usa a água para as suas atividades do quotidiano. A água é um recurso natural escasso cuja qualidade deve ser protegida, defendida, gerida e tratada em conformidade com o seu uso. Nesse âmbito, a gestão das águas prossegue objetivos de proteção da saúde humana e de preservação, proteção e melhoria da qualidade do ambiente[1]. Desde o final do seculo XIX até aos dias de hoje, verificou-se uma forte evolução nos sistemas de tratamento de águas residuais. Esta evolução foi fundamental para dar resposta às maiores exigências de qualidade do efluente tratado. O sistema de lamas ativadas é um dos processos de tratamento biológico das águas residuais mais usados em todo o mundo. Este trabalho consiste no desenvolvimento do projeto de conceção e dimensionamento de uma Estação de Tratamento de Águas Residuais (ETAR) para servir um pequeno aglomerado de cerca de 3200 habitantes equivalentes (hab.eq.), tendo como objetivo o dimensionamento de todas as etapas de tratamento necessárias ao cumprimento da legislação em vigor para a descarga das águas residuais urbanas no meio recetor. O Decreto-lei nº 152/97[2], relativo ao tratamento de águas residuais urbanas, juntamente com o Decreto-lei nº 149/2004[3] que identifica as zonas sensíveis e de zonas menos sensíveis, permitem que as entidades licenciadoras definam o grau de tratamento que a instalação deve possuir tendo em consideração a classificação do meio onde o efluente tratado é descarregado. O Decreto-Lei n.º 135/2009[1] estabelece o regime de identificação, gestão, monitorização e classificação da qualidade das águas balneares, impondo a qualidade microbiológica da água residual tratada mediante o meio recetor, e portanto conseguindo-se assim definir o tratamento de desinfeção a adotar. Resumidamente, a conceção do tratamento focou as seguintes etapas: tratamento preliminar formado por uma unidade compacta de tamisação, desarenador e desengordurador, tratamento secundário por lamas ativadas em regime de arejamento prolongado constituído por dois reatores com cerca de 400 m3 de volume seguido de um decantador com um diâmetro de 9.5 m, tratamento terciário de desinfeção composto por uma microtamisação seguido de desinfeção UV, e a utilização das operações comuns de espessamento e desidratação das lamas produzidas em excesso pelo tratamento, constituída por com um espessador gravítico com 4.6 m de diâmetro, e um filtro banda para a desidratação.
Resumo:
Esta dissertação descreve o trabalho desenvolvido ao longo de um ano e um mês desde a pesquisa teórica até à prática experimental no âmbito da unidade curricular de Dissertação/estágio do Mestrado em Engenharia Química, no ramo Tecnologias em Proteção Ambiental. O tema desta dissertação consiste na avaliação do funcionamento de duas estações de tratamento de águas residuais (ETAR) do interior do município de Vila Nova de Gaia no que diz respeito ao possível aumento da resistência a antibióticos na ETAR de Febros e na ETAR de Lever. Os testes de sensibilidade a antibióticos (TSA) foram executados para ambas as ETAR, sendo as amostras de água recolhidas na entrada e na saída dos reatores biológicos (tratamento secundário). Além disso, foram realizados testes de avaliação da eficiência de desinfeção por radiação ultravioleta (UV) relativamente à Escherichia coli (E. coli) na ETAR de Lever. Os antibióticos selecionados para a realização deste trabalho foram a Eritromicina, a Azitromicina, a Claritromicina, a Ofloxacina, a Ciprofloxacina, o Sulfametoxazol, o Trimetoprim e o Metronidazol. Esta seleção baseou-se no facto de estes serem alguns dos antibióticos mais consumidos e mais persistentes no meio ambiente. A bactéria E. coli (isolada a partir de amostras das águas residuais estudadas) foi escolhida para a realização deste estudo uma vez que está sempre presente nas águas residuais domésticas e está associada a fenómenos de multirresistência a antibióticos. Os testes de TSA foram realizados seguindo a metodologia de difusão por discos. No período do estudo (Março a Junho de 2015) identificaram-se situações quer de aumento de resistência quer de aumento de sensibilidade aos antibióticos testados. As situações mais graves de aumento de resistência, a que corresponderam a halos nulos, verificaram-se para os antibióticos Claritromicina, Trimetoprim e Metronidazol, ocorrendo com maior frequência para os dois últimos, que aliás são fármacos que são administrados em simultâneo. Os períodos mais problemáticos em termos de aumento das resistências foram ligeiramente diferentes nas duas ETAR. No caso da ETAR de Febros correspondeu ao mês Abril e na ETAR de Lever ocorreu entre o final de Abril e o início de Maio. Considera-se que estes períodos poderão coincidir com um aumento do consumo destes fármacos devido à sua utilização no combate a infeções respiratórias muito comuns nesta altura do ano. Não se observou qualquer sensibilidade da E. coli para o Metronidazol porque é um antibiótico com indicação para algumas bactérias anaeróbias, fungos e giardia, e que à partida não tem capacidade para eliminar a E. coli. A eficiência da desinfeção na ETAR de Lever relativamente à remoção de E. coli foi satisfatória. Sendo de salientar a importância da manutenção, no que se refere à identificação de possíveis avarias nas lâmpadas e correspondente limpeza. Os resultados deste trabalho provam a existência de estirpes da bactéria E. coli resistentes a alguns dos antibióticos estudados, o que reforça a importância da desinfeção no tratamento de águas residuais domésticas.
Resumo:
O presente relatório é o corolário do Estágio Curricular que a autora efetuou, durante o segundo semestre do ano letivo de 2014/2015 na SBS – Engenharia Civil, Hidráulica e Ambiente, Lda. Nesta empresa a autora foi integrada na equipa técnica que elaborou um Projeto de Execução para uma Estação de Tratamento de Águas Residuais que irá ser construída em Montemor-o-Novo, tendo-lhe sido atribuídas as seguintes tarefas principais: i) estudo de ferramentas de dimensionamento de ETAR; e ii) estudo dos processos de tratamento de águas residuais a instalar. O tratamento de águas residuais não é matéria que conste do atual Plano de Estudos do Mestrado em Engenharia Civil do ISEP. Este facto, associado à premente necessidade de dar resposta às expectativas da Entidade Acolhedora, obrigou a autora a um esforço de aprendizagem significativo. Nesta fase foi executada uma aprofundada pesquisa bibliográfica que permitiu à autora obter o nível de conhecimentos teóricos necessário para a plena integração na Equipa de Projeto. Já integrada na Equipa de Projeto o primeiro trabalho desenvolvido pela autora foi a análise detalhada do Caderno de Encargos e da respetiva Nota Técnica. Seguidamente a autora participou em todas as fases do Projeto tendo, por isso, colaborado na análise do Estudo Geotécnico, no dimensionamento dos órgãos da ETAR, no cálculo do perfil hidráulico, na definição de formas (plantas e cortes) dos órgãos, na elaboração da Lista de Equipamentos e do Mapa de Quantidades e, por último, na elaboração da Memória Descritiva e Justificativa do Processo de Tratamento e Equipamentos. O Caso Prático incluído no presente documento é, em larga medida, o corolário do processo de aprendizagem de que a autora beneficiou no decorrer do Estágio Curricular. Grande parte das tarefas que a autora executou ao longo da elaboração do projeto relacionaram-se com o dimensionamento dos órgãos da ETAR e com os respetivos cálculos hidráulicos. Os conhecimentos teórico-práticos desta forma adquiridos foram reunidos num conjunto de ferramentas, maioritariamente folhas de cálculo, que se verificou serem úteis nos processos de dimensionamento e de teste de soluções alternativas. É parte integrante deste relatório um capítulo no qual é feita uma detalhada apresentação dos conceitos teóricos subjacentes ao Projeto de ETAR. Este capítulo reflete o estudo que a autora teve necessidade de efetuar antes de se sentir capaz de integrar a Equipa de Projeto.
Resumo:
Dissertação para a obtenção do Grau de Mestre em Engenharia e Gestão da Água
Resumo:
Enhanced biological phosphorus removal (EBPR) is the most economic and sustainable option used in wastewater treatment plants (WWTPs) for phosphorus removal. In this process it is important to control the competition between polyphosphate accumulating organisms (PAOs) and glycogen accumulating organisms (GAOs), since EBPR deterioration or failure can be related with the proliferation of GAOs over PAOs. This thesis is focused on the effect of operational conditions (volatile fatty acid (VFA) composition, dissolved oxygen (DO) concentration and organic carbon loading) on PAO and GAO metabolism. The knowledge about the effect of these operational conditions on EBPR metabolism is very important, since they represent key factors that impact WWTPs performance and sustainability. Substrate competition between the anaerobic uptake of acetate and propionate (the main VFAs present in WWTPs) was shown in this work to be a relevant factor affecting PAO metabolism, and a metabolic model was developed that successfully describes this effect. Interestingly, the aerobic metabolism of PAOs was not affected by different VFA compositions, since the aerobic kinetic parameters for phosphorus uptake, polyhydroxyalkanoates (PHAs) degradation and glycogen production were relatively independent of acetate or propionate concentration. This is very relevant for WWTPs, since it will simplify the calibration procedure for metabolic models, facilitating their use for full-scale systems. The DO concentration and aerobic hydraulic retention time (HRT) affected the PAO-GAO competition, where low DO levels or lower aerobic HRT was more favourable for PAOs than GAOs. Indeed, the oxygen affinity coefficient was significantly higher for GAOs than PAOs, showing that PAOs were far superior at scavenging for the often limited oxygen levels in WWTPs. The operation of WWTPs with low aeration is of high importance for full-scale systems, since it decreases the energetic costs and can potentially improve WWTP sustainability. Extended periods of low organic carbon load, which are the most common conditions that exist in full-scale WWTPs, also had an impact on PAO and GAO activity. GAOs exhibited a substantially higher biomass decay rate as compared to PAOs under these conditions, which revealed a higher survival capacity for PAOs, representing an advantage for PAOs in EBPR processes. This superior survival capacity of PAOs under conditions more closely resembling a full-scale environment was linked with their ability to maintain a residual level of PHA reserves for longer than GAOs, providing them with an effective energy source for aerobic maintenance processes. Overall, this work shows that each of these key operational conditions play an important role in the PAO-GAO competition and should be considered in WWTP models in order to improve EBPR processes.