989 resultados para SCREENING ACCURACY
Resumo:
Aims We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). Methods and results Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and A beta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (0). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and A beta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and A beta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and A beta reserves, respectively. Conclusion Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.
Resumo:
Background: Dementia screening in elderly people with low education can be difficult to implement. For these subjects, informant reports using the long (L) (26 items) and short (C) (16 items) versions of the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) can be useful. The objective of the present study was to investigate the performance of Brazilian versions of the IQCODE L, S and a new short version (SBr) (15 items) in comparison with the Mini-mental State Examination (MMSE) for dementia screening in elderly people with low education. Methods: Thirty-four patients with mild to moderate dementia, diagnosed according to ICD-10 criteria, and 57 controls were evaluated and divided into three groups based on their socioeconomic status and level of education. Patients were evaluated using the MMSE and the informants were interviewed using the IQCODE by interviewers blind to the clinical diagnosis. Results: Education was correlated with MMSE results (r = 0.280, p = 0.031), but not with the versions of the IQCODE. The performance of the instruments, evaluated by the ROC curves, was very similar, with good internal consistency (Cronbach`s alpha = 0.97). MMSE correctly classified 85.7% of the subjects while the three IQCODE versions (L, S and SBr) correctly classified 91.2% of the subjects. Conclusions: The long, short and the new short Brazilian IQCODE versions can be useful as a screening tool for mild and moderate patients with dementia in Brazil. The IQCODE is not biased by schooling, and it seems to be an adequate instrument for samples with low levels of education.
Resumo:
Background The CAMCOG is a brief neuropsychological battery designed to assess global cognitive function and ascertain the impairments that are required for the diagnosis of dementia. To date, the cut-off scores for mild cognitive impairment (MCI) have not been determined. Given the need for an earlier diagnosis of mild dementia, new cut-off values are also necessary, taking into account cultural and educational effects. Methods One hundred and fifty-seven older adults (mean age: 69.6 +/- 7.4 years) with 8 or more years of formal education (mean years of schooling 14.2 +/- 3.8) attending a memory clinic at the Institute of Psychiatry University of Sao Paulo were included. Subjects were divided into three groups according to their cognitive status, established through clinical and neuropsychological assessment: normal controls, n = 62; MCI, n = 65; and mild or moderate dementia, n = 30. ROC curve analyses were performed for dementia vs controls, MCI vs controls and MCI vs dementia. Results The cut-off values were: 92/93 for dementia is controls (AUC = 0.99: sensitivity: 100%, specificity: 95%); 95/96 for MCI vs controls (AUC = 0.83, sensitivity: 64%, specificity: 88%), and 85/86 for MCI vs dementia (AUC = 0.91, sensitivity: 81%, specificity: 88%). The total CAMCOG score was more accurate than its subtests Mini-mental State Examination, Verbal Fluency Test and Clock Drawing Test when used separately. Conclusions The CAMCOG discriminated controls and MCI from demented patients, but was less accurate to discriminate MCI from controls. The best cut-off value to differentiate controls and demented was higher than suggested in the original publication, probably because only cases of mild to moderate dementia were included. This is important given the need for a diagnostic at earlier stages of Alzheimer`s disease. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Introduction. Lower urinary tract symptoms (LUTS) and erectile dysfunction (ED) are common problems in middle-aged and older men. Recently, epidemiologic studies have shown significant associations between severity of LUTS and male sexual dysfunction. Aim. We analyzed the role of prostate enlargement, LUTS, and prostate specific antigen (PSA) levels in the erectile function of Brazilian men who underwent prostate cancer (PCa) screening. Method. We analyzed data from 1,008 consecutive patients enrolled in a PCa screening program. Benign prostatic hyperplasia (BPH) was defined as a prostate weight greater than 30 g as defined by digital rectal examination. For statistical analysis, we used the chi-squared and analysis of variance tests. The odds ratios (OR) for correlation of ED with prostate volume LUTS and PSA were estimated using logistic regression models. Main Outcome Measure. The American Urological Association (AUA) symptom score for LUTS and the International Index of Erectile Function. Results. Mean patient age was 61.2 years (45-87) and median PSA value was 1.9 ng/mL. BPH was identified in 48.5% of patients. Mild, moderate, and severe LUTS were found in 52.3%, 30.9%, and 16.8% of cases, respectively. ED was classified as absent, mild, mild to moderate, moderate, and severe in 18.6%, 23.1%, 18.6%, 15.2%, and 24.5%, respectively. While only 5.4% of the patients with no ED presented severe LUTS, this finding was observed in 27.1% of patients with severe ED (P<0.001). Univariate logistic regression analysis demonstrated that age, prostate volume, AUA symptom score, and PSA levels were significant predictors of ED. However, when controlled for patient age, only LUTS remained as an independent predictor of ED. Conclusions. Controlling for patient age, LUTS are independent risk factors for the development of ED among Brazilian men who undergo PCa screening.
Resumo:
Antibody phage display libraries are a useful tool in proteomic analyses. This study evaluated an antibody recombinant library for identification of sex-specific proteins on the sperm cell surface. The Griffin.1 library was used to produce phage antibodies capable of recognizing membrane proteins from Nelore sperm cells. After producing soluble monoclonal scFv, clones were screened on Simental sperm cells by flow cytometry and those that bound to 40-60% of cells were selected. These clones were re-analyzed using Nelore sperm cells and all clones bound to 40-60% of cells. Positive clones were submitted to a binding assay against male and female bovine leukocytes by flow cytometry and one clone preferentially bound to male cells. The results indicate that phage display antibodies are an alternative method for identification of molecules markers on sperm cells. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
P>Objective Congenital hypogonadotropic hypogonadism with anosmia (Kallmann syndrome) or with normal sense of smell is a heterogeneous genetic disorder caused by defects in the synthesis, secretion and action of gonadotrophin-releasing hormone (GnRH). Mutations involving autosomal genes have been identified in approximately 30% of all cases of hypogonadotropic hypogonadism. However, most studies that screened patients with hypogonadotropic hypogonadism for gene mutations did not include gene dosage methodologies. Therefore, it remains to be determined whether patients without detected point mutation carried a heterozygous deletion of one or more exons. Measurements We used the multiplex ligation-dependent probe amplification (MLPA) assay to evaluate the potential contribution of heterozygous deletions of FGFR1, GnRH1, GnRHR, GPR54 and NELF genes in the aetiology of GnRH deficiency. Patients We studied a mutation-negative cohort of 135 patients, 80 with Kallmann syndrome and 55 with normosmic hypogonadotropic hypogonadism. Results One large heterozygous deletion involving all FGFR1 exons was identified in a female patient with sporadic normosmic hypogonadotropic hypogonadism and mild dimorphisms as ogival palate and cavus foot. FGFR1 hemizygosity was confirmed by gene dosage with comparative multiplex and real-time PCRs. Conclusions FGFR1 or other autosomal gene deletion is a possible but very rare event and does not account for a significant number of sporadic or inherited cases of isolated GnRH deficiency.
Resumo:
Objective. To analyze the psychometric properties of the Brazilian Portuguese version of the Beck Anxiety Inventory (BAI) in terms of its internal consistency, scores distribution, concurrent and discriminant validity, and factorial analysis in a sample of university students and social anxiety disorder (SAD) cases and non-cases. Methods. A sample of Brazilian university students from the general population (N = 2314) and a sample of university students identified as cases (N = 88) and non-cases (N = 90) of SAD were assessed, using as a parameter the Structured Clinical Interview for the DSM-IV. The different instruments were completed individually in the presence of an experienced rater. Results. The BAI showed adequate internal consistency (0.88-0.92) and discriminant validity, with 0.74 sensitivity and 0.71 specificity for a cut-off score of 10. The factorial analysis suggested a three-factor solution to be the most adequate. Conclusions. The version of the BAI studied is quite adequate to be used in the context of Brazilian university students, identifying the presence of anxiety indicators. However, its usefulness to screen for SAD seems limited.
Resumo:
PURPOSE. The purpose of this study was to further assess the psychometric qualities of the Mini-Social Phobia Inventory (MS) to screen for social anxiety disorder (SAD). DESIGN AND METHODS. The MS and other self- and clinician-rated scales for anxiety and social anxiety were applied in 2,314 university students and in samples of SAD patients (n = 88) and nonpatients (n = 90). FINDINGS. The MS revealed adequate discriminative validity, internal consistency (alpha = 0.49-0.73), convergent validity with the Social Phobia Inventory, Brief Social Phobia Scale, and Self-Statements During Public Speaking Scale and convergent and divergent validity with the Beck Anxiety Inventory. PRACTICE IMPLICATIONS. The MS has shown to be a fast and efficient screening instrument for SAD in different cultures and contexts.
Resumo:
This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.
Resumo:
Wills' Mineral Processing Technology provides practising engineers and students of mineral processing, metallurgy and mining with a review of all of the common ore-processing techniques utilized in modern processing installations. Now in its Seventh Edition, this renowned book is a standard reference for the mineral processing industry. Chapters deal with each of the major processing techniques, and coverage includes the latest technical developments in the processing of increasingly complex refractory ores, new equipment and process routes. This new edition has been prepared by the prestigious J K Minerals Research Centre of Australia, which contributes its world-class expertise and ensures that this will continue to be the book of choice for professionals and students in this field. This latest edition highlights the developments and the challenges facing the mineral processor, particularly with regard to the environmental problems posed in improving the efficiency of the existing processes and also in dealing with the waste created. The work is fully indexed and referenced.
Resumo:
The aim of this investigation was to assess the diagnostic accuracy of intraoperative cultures for the early identification of patients who are at risk of infection after primary total hip arthroplasty. Four or six swabs were obtained immediately before the wound closure in 263 primary total hip replacements. Patients with a maximum of one positive culture were denoted as patients with a normal profile and did not receive any treatment. Patients with two or more positive cultures, with the same organism identified, were denoted as patients with a risk profile and received treatment with a specific antibiotic as determined by the antibiogram for six weeks. The follow-up ranged from a minimum of one year to five years and eleven months, concentrating on the presence or absence of infection, which was defined as discharge of pus through the surgical wound or as a fistula at any time after surgery. The accuracy of this procedure ( number of cases correctly identified in relation to the total number of cases) in the group of 152 arthroplasties in which 4 swabs per patient were collected was 96%. In the group of 111 arthroplasties in which 6 swabs per patient were collected the accuracy was 95.5%. We conclude that the collection of swabs under the conditions described is a method of high accuracy ( above 95%) for the evaluation of risk of infection after primary total hip arthroplasty.
Resumo:
BACKGROUND: Comparative genomic hybridization (CGH) is a valuable alternative to fluorescence in situ hybridization (FISH) for preimplantation genetic screening (PGS) because it allows full karyotype analysis. However, this approach requires the cryopreservation of biopsied embryos until results are available. The aim of this study is to reduce the hybridization period of CGH, in order to make this short-CGH technique suitable for PGS of Day-3 embryos, avoiding the cryopreservation step. METHODS: Thirty-two fibroblasts from six aneuploid cell lines (Coriell) and 48 blastomeres from 10 Day-4 embryos, discarded after PGS by FISH with 9 probes (9-chr-FISH), were analysed by short-CGH. A reanalysis by the standard 72 h-CGH and FISH using telomeric probes was performed when no concordant results between short-CGH and FISH diagnosis were observed. The short-CGH was subsequently applied in a clinical case of advanced maternal age. RESULTS: In 100% of the fibroblasts analysed, the characteristic aneuploidies of each cell line were detected by short-CGH. The results of the 48 blastomeres screened by short-CGH were supported by both 72 h-CGH results and FISH reanalysis. The chromosomes most frequently involved in aneuploidy were 22 and 16, but aneuploidies for the other chromosomes, excepting 1, 10 and 13, were also detected. Forty-one of the 94 aneuploid events observed (43.6%) corresponded to chromosomes which are not analysed by 9-chr-FISH. CONCLUSIONS: We have performed a preliminary validation of the short-CGH technique, including one clinical case, suggesting this approach may be applied to Day-3 aneuploidy analysis, thereby avoiding embryo cryopreservation and perhaps helping to improve implantation rate after PGS.
Resumo:
Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.