Dimensional Accuracy of Computer-Aided Design/Computer-Assisted Manufactured Orbital Prostheses


Autoria(s): MARAFON, Priscila Galzo; MATTOS, Beatriz Silva Camara; SABOIA, Antonio Carlos Lorenz; NORITOMI, Pedro Yoshito
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2010

Resumo

Purpose: The aim of this research was to assess the dimensional accuracy of orbital prostheses based on reversed images generated by computer-aided design/computer-assisted manufacturing (CAD/CAM) using computed tomography (CT) scans. Materials and Methods: CT scans of the faces of 15 adults, men and women older than 25 years of age not bearing any congenital or acquired craniofacial defects, were processed using CAD software to produce 30 reversed three-dimensional models of the orbital region. These models were then processed using the CAM system by means of selective laser sintering to generate surface prototypes of the volunteers` orbital regions. Two moulage impressions of the faces of each volunteer were taken to manufacture 15 pairs of casts. Orbital defects were created on the right or left side of each cast. The surface prototypes were adapted to the casts and then flasked to fabricate silicone prostheses. The establishment of anthropometric landmarks on the orbital region and facial midline allowed for the data collection of 31 linear measurements, used to assess the dimensional accuracy of the orbital prostheses and their location on the face. Results: The comparative analyses of the linear measurements taken from the orbital prostheses and the opposite sides that originated the surface prototypes demonstrated that the orbital prostheses presented similar vertical, transversal, and oblique dimensions, as well as similar depth. There was no transverse or oblique displacement of the prostheses. Conclusion: From a clinical perspective, the small differences observed after analyzing all 31 linear measurements did not indicate facial asymmetry. The dimensional accuracy of the orbital prostheses suggested that the CAD/CAM system assessed herein may be applicable for clinical purposes. Int J Prosthodont 2010;23:271-276.

Foundation for Research Support of the State of Sao Paulo (FAPESP-Fundacao de Amparo a Pesquisa do Estado de Sao Paulo)[06/03765-4]

Identificador

INTERNATIONAL JOURNAL OF PROSTHODONTICS, v.23, n.3, p.271-276, 2010

0893-2174

http://producao.usp.br/handle/BDPI/25575

http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000278617200015&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord

Idioma(s)

eng

Publicador

QUINTESSENCE PUBLISHING CO INC

Relação

International Journal of Prosthodontics

Direitos

restrictedAccess

Copyright QUINTESSENCE PUBLISHING CO INC

Palavras-Chave #CAPTURING 3-DIMENSIONAL DATA #DEVELOPING FACIAL PROSTHESES #AURICULAR PROSTHESES #CAD/CAM TECHNIQUES #EAR #FABRICATION #DESIGN #TOMOGRAPHY #STEREOLITHOGRAPHY #REHABILITATION #Dentistry, Oral Surgery & Medicine
Tipo

article

original article

publishedVersion