790 resultados para Pipe fittings
Resumo:
Desde o in??cio de 2000, a Canada School of Public Service (CSPS) e a Escola Nacional de Administra????o P??blica (ENAP) demonstraram interesse na possibilidade de coopera????o para desenvolver capacidades de gest??o de servidores p??blicos brasileiros. Um acordo assinado em 2003, inicialmente foi planejado para ser uma parceria de tr??s anos entre as duas escolas. No entanto, a parceria continua at?? hoje e agora estamos no final do segundo, e ??ltimo projeto de coopera????o t??cnica financiado pela Canadian International Development Agency (CIDA) entre Brasil e Canad??, denominado ???Desenvolvimento da Capacidade de Governan??a???. Este relat??rio representa o resultado deste segundo projeto, o qual ampliou o esfor??o de capacita????o da primeira parceria, focando agora em funcion??rios p??blicos mais pr??ximos da "linha de frente" da presta????o de servi??os, aumentando assim a efic??cia do governo nessas ??reas. O projeto mostrou ser bem-sucedido, principalmente, porque seguiu de perto os princ??pios do desenvolvimento eficaz e sustent??vel. Considerando a sua miss??o de desenvolver compet??ncias de servidores p??blicos, a ENAP deu prioridade, dentro deste projeto de coopera????o com o Canad??, a atividades que visam refor??ar a capacidade de governan??a do pa??s, trabalhando em conjunto com escolas em cinco regi??es: Norte, Nordeste, Centro-Oeste, Sudeste e Sul, com especial ??nfase nas ??reas mais pobres do pa??s, localizadas nas regi??es Norte e Nordeste. Foram participantes-chave neste projeto: i) seis escolas brasileiras regionais de administra????o p??blica; ii) uma das principais institui????es acad??micas do Canad?? - Queen's University, e iii) o Minist??rio do Desenvolvimento Social e Combate ?? Fome e tr??s Secretarias de Ra??a, Direitos Humanos e Pol??ticas para as Mulheres. Neste projeto, a CSPS compartilhou suas metodologias em educa????o a dist??ncia, lideran??a e gest??o p??blica. Trabalhando com parceiros brasileiros, ela tamb??m transferiu e adaptou curr??culos e conte??dos de seus cursos. A CIDA forneceu $1.845.000,00 por meio da Programa de Interc??mbio de Conhecimentos para a Promo????o da Eq??idade (PIPE) Brasil-Canad??. A ENAP e as EPBs contribu??ram com $993,752 e a CSPS contribuiu com material de curso, conhecimento e apoio t??cnico no valor de $ 1.000.000
Resumo:
Desde a d??cada de 1990, o Governo Federal brasileiro vem implementando uma agenda ambiciosa de reformas do Estado, centradas na redu????o da pobreza e na melhoria da efici??ncia dos servi??os p??blicos. As principais prioridades, conforme previstas no Plano Plurianual (PPA) para o per??odo 2003-2007, s??o as seguintes: inclus??o social e redu????o da desigualdade; crescimento econ??mico com gera????o de emprego; distribui????o de renda e respeito ao meio ambiente; promo????o e amplia????o dos direitos de cidadania; e fortalecimento da democracia. No in??cio de 2006, o Governo criou a Pol??tica Nacional de Desenvolvimento de Pessoal (Decreto 5.707), com o objetivo de melhorar e aumentar a efici??ncia e a efic??cia na presta????o de servi??os p??blicos. No marco dessa pol??tica recente, as escolas de administra????o p??blica desempenham um papel fundamental na identifica????o das compet??ncias que precisam ser desenvolvidas nas institui????es do governo, bem como na implementa????o de pol??ticas de capacita????o para os servidores p??blicos, diretamente e/ou em parceria com escolas de governo nos n??veis federal, estadual ou local. O Canad?? tamb??m est?? criando uma estrutura para levantar as compet??ncias necess??rias para os servidores p??blicos e desenvolv??-las como um componente da Renova????o do Servi??o P??blico em todo o governo. Como institui????es l??deres no desenvolvimento de compet??ncias de servidores p??blicos, a Canada School of Public Service (CSPS) e a Escola Nacional de Administra????o P??blica (ENAP) firmaram uma parceria para implementar o Projeto de Desenvolvimento de Capacidade de Governan??a no Brasil. A finalidade do Projeto ?? melhorar a capacidade de servidores p??blicos federais, estaduais e municipais do Brasil para desenvolver e implementar programas de capacita????o e gerenciar pol??ticas p??blicas descentralizadas. Espera-se que essa parceria e o resultante compartilhamento de experi??ncias em capacita????o para governan??a efetiva contribuam para a redu????o da pobreza e das desigualdades no Brasil, por meio do desenvolvimento de compet??ncias de servidores na presta????o de servi??os p??blicos eficazes e eficientes, voltados para o cidad??o. O Projeto re??ne, al??m das duas principais Escolas de Governo no Canad?? e no Brasil, seis Escolas Brasileiras de Administra????o P??blica regionais e duas renomadas Institui????es Acad??micas Canadenses ??? a Queen???s University e a Western Ontario University. O Minist??rio do Desenvolvimento Social e Combate ?? Fome (MDS) e tr??s Secretarias Especiais do Governo Federal ??? Ra??a (SEPPIR), Direitos Humanos (SEDH) e Pol??ticas para as Mulheres (SPM) ??? tamb??m se envolver??o nas atividades de compartilhamento de conhecimentos com o Human Resources and Skills Development Canada (HRSDC) e a Canada Public Service Agency (CPSA). A CIDA fornecer?? CND$1.700.000 por meio do Programa Brasil-Canad?? de Interc??mbio de Conhecimentos para a Promo????o da Equidade (PIPE). A contribui????o da ENAP ser?? de CND$1.069.707 em esp??cie. A CSPS contribuir?? com cursos, al??m de conhecimentos e suporte t??cnicos, avaliados em CND$1.000.000. Aproveitando a parceria entre a CSPS e a ENAP, que resultou na transfer??ncia e na adapta????o bem sucedidas de cursos e metodologias canadenses, o novo projeto extrapola o n??cleo do servi??o p??blico em Bras??lia, alcan??ando escolas de governo em regi??es brasileiras em situa????o de desvantagem. ?? semelhan??a do papel da CSPS no primeiro projeto, a ENAP fortalecer?? a capacidade das escolas parceiras regionais para capacitar servidores p??blicos envolvidos na presta????o de servi??os aos brasileiros. O interc??mbio estruturado entre Minist??rios dos Governos canadense e brasileiro tamb??m aplicar?? a aprendizagem mais diretamente a quest??es de pol??ticas e programas sociais do Brasil. O desafio assumido neste Projeto ?? a adapta????o de conhecimentos e aprendizagem, com vistas a melhorar a implementa????o de pol??ticas e programas sociais. Para tanto, a CSPS e a ENAP introduzir??o novos cursos nos curr??culos das escolas parceiras e incorporar??o novos m??todos e tecnologias de aprendizagem como, por exemplo, comunidades de pr??tica virtuais e um componente de tutoria (mentoring) envolvendo o Human Resources and Skills Development Canada e o Minist??rio do Desenvolvimento Social e Combate ?? Fome do Brasil. Seis institui????es da Rede Nacional de Escolas de Governo do Brasil e do Programa de Parceria da ENAP foram selecionadas e convidadas a se unir ?? CSPS e ?? ENAP nesse novo Projeto: a Universidade Federal do Par?? (UFPA), de Bel??m (estado do Par?? ??? regi??o Norte); a Funda????o Joaquim Nabuco (FUNDAJ), de Recife (Pernambuco ??? Nordeste); a Universidade Corporativa do Servi??o P??blico / Secretaria de Administra????o do Estado da Bahia (UCS/SAEB), Salvador (Bahia ??? Nordeste); a Escola de Governo do Mato Grosso do Sul (ESCOLAGOV), Campo Grande (estado do Mato Grosso do Sul ??? Centro-Oeste); a Escola Nacional de Ci??ncias Estat??sticas / Instituto Brasileiro de Geografia e Estat??stica (ENCE/IBGE), Rio de Janeiro (estado do Rio de Janeiro ??? Sudeste); e o Instituto Municipal de Administra????o P??blica (IMAP) de Curitiba (Paran?? ??? Sul). Essas escolas de refer??ncia foram escolhidas segundo sua capacidade de trabalhar como p??los de pr??ticas inovadoras em pol??ticas p??blicas e disseminar os benef??cios do Projeto para outras escolas em suas regi??es, por meio da Rede Nacional coordenada pela ENAP. O objetivo dessa parceria ?? fortalecer as escolas de governo locais, para que estas desenvolvam, por meio de eventos de aprendizagem, compet??ncias em servidores p??blicos, a fim de aumentar a capacidade do governo na implementa????o e gest??o de pol??ticas p??blicas. O Plano de Implementa????o do Projeto (PIP) descreve o trabalho a ser realizado por essas institui????es nos pr??ximos 30 meses, ao tempo em que serve de guia para os Parceiros do Projeto no que se refere ??s a????es e aos recursos necess??rios para a obten????o dos resultados acordados. Na medida em que o Projeto estiver em andamento e os parceiros iniciarem um interc??mbio produtivo de conhecimentos, o Plano de Trabalho Anual ser?? atualizado e revisto por meio de reuni??es anuais de avalia????o e encontros do Comit?? Diretor do Projeto, com vistas a assegurar que os resultados descritos no PIP sejam alcan??ados com sucesso
Resumo:
Pretende-se com este trabalho de Projecto de Mestrado conceber uma câmara frigorífica de 20000 m3 para armazenar produtos congelados e estudar um sistema frigorífico com dois fluidos frigorigénios que serão o CO2 (R-744) e o NH3 (R-717) O trabalho inicia-se com a definição dos objectivos principais para o projecto de um sistema frigorífico deste tipo. Após a definição dos objectivos, o projecto propõe um estudo termodinâmico do CO2 (R-744) como fluido frigorigénio, definindo se o seu historial de utilização, características principais, diagrama pressão-entalpia com a distinção das diversas fases do fluído, comparação em diversos parâmetros com outros fluidos, o porquê da utilização deste fluído, problemas comuns em sistemas com a presença deste fluído, entre outros parâmetros de estudo. De seguida será feito o dimensionamento de uma câmara frigorífica de 20000 m3 para armazenar produtos congelados paletizados através de um balanço térmico manual e um balanço térmico informático através do programa da Centauro comparando no final o resultado dos dois métodos. Será feito uma descrição das características básicas da câmara frigorífica com um esquema simples do edifício. Será abordado de seguida o sistema frigorífico a CO2 (R-744) e a NH3 (R-717) nas suas diversas características, nomeadamente no cálculo de caudais, diagrama pressão-entalpia, dimensionamento de tubagens e finalmente selecção de equipamento. Procede-se assim também ao estudo um sistema apenas a NH3 (R-717) com as suas diversas características nomeadamente no cálculo de caudais, diagrama pressão-entalpia, dimensionamento de tubagens e finalmente selecção dos equipamentos mais importantes, para que desta forma se proceda à comparação dos dois sistemas a nível energético, consumo eléctrico e manutenção de equipamentos. Finalmente proceder-se-á interpretação de resultados com o objectivo final de escolher a melhor solução nos vários parâmetros de comparação, para o esquema em questão.
Computational evaluation of hydraulic system behaviour with entrapped air under rapid pressurization
Resumo:
The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.
Computational evaluation of hydraulic system behaviour with entrapped air under rapid pressurization
Resumo:
The pressurization of hydraulic systems containing entrapped air is considered a critical condition for the infrastructure's security due to transient pressure variations often occurred. The objective of the present study is the computational evaluation of trends observed in variation of maximum surge pressure resulting from rapid pressurizations. The comparison of the results with those obtained in previous studies is also undertaken. A brief state of art in this domain is presented. This research work is applied to an experimental system having entrapped air in the top of a vertical pipe section. The evaluation is developed through the elastic model based on the method of characteristics, considering a moving liquid boundary, with the results being compared with those achieved with the rigid liquid column model.
Resumo:
The presence of entrapped air in pressurized hydraulic systems is considered a critical condition for the infrastructure security, due to the transient pressure enhancement related with its dynamic behaviour, similar to non-linear spring action. A mathematical model for the assessment of hydraulic transients resulting from rapid pressurizations, under referred condition is presented. Water movement was modeled through the elastic column theory considering a moving liquid boundary and the entrapped air pocket as lumped gas mass, where the acoustic effects are negligible. The method of characteristics was used to obtain the numerical solution of the liquid flow. The resulting model is applied to an experimental set-up having entrapped air in the top of a vertical pipe section and the numerical results are analyzed.
Resumo:
OBJECTIVE: To assess the impact of town planning, infrastructure, sanitation and rainfall on the bacteriological quality of domestic water supplies. METHODS: Water samples obtained from deep and shallow wells, boreholes and public taps were cultured to determine the most probable number of Escherichia coli and total coliform using the multiple tube technique. Presence of enteric pathogens was detected using selective and differential media. Samples were collected during both periods of heavy and low rainfall and from municipalities that are unique with respect to infrastructure planning, town planning and sanitation. RESULTS: Contamination of treated and pipe distributed water was related with distance of the collection point from a utility station. Faults in pipelines increased the rate of contamination (p<0.5) and this occurred mostly in densely populated areas with dilapidated infrastructure. Wastewater from drains was the main source of contamination of pipe-borne water. Shallow wells were more contaminated than deep wells and boreholes and contamination was higher during period of heavy rainfall (p<0.05). E. coli and enteric pathogens were isolated from contaminated supplies. CONCLUSIONS: Poor town planning, dilapidated infrastructure and indiscriminate siting of wells and boreholes contributed to the low bacteriological quality of domestic water supplies. Rainfall accentuated the impact.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Water covers over 70% of the Earth's surface, and is vital for all known forms of life. But only 3% of the Earth's water is fresh water, and less than 0.3% of all freshwater is in rivers, lakes, reservoirs and the atmosphere. However, rivers and lakes are an important part of fresh surface water, amounting to about 89%. In this Master Thesis dissertation, the focus is on three types of water bodies – rivers, lakes and reservoirs, and their water quality issues in Asian countries. The surface water quality in a region is largely determined both by the natural processes such as climate or geographic conditions, and the anthropogenic influences such as industrial and agricultural activities or land use conversion. The quality of the water can be affected by pollutants discharge from a specific point through a sewer pipe and also by extensive drainage from agriculture/urban areas and within basin. Hence, water pollutant sources can be divided into two categories: Point source pollution and Non-point source (NPS) pollution. Seasonal variations in precipitation and surface run-off have a strong effect on river discharge and the concentration of pollutants in water bodies. For example, in the rainy season, heavy and persistent rain wash off the ground, the runoff flow increases and may contain various kinds of pollutants and, eventually, enters the water bodies. In some cases, especially in confined water bodies, the quality may be positive related with rainfall in the wet season, because this confined type of fresh water systems allows high dilution of pollutants, decreasing their possible impacts. During the dry season, the quality of water is largely related to industrialization and urbanization pollution. The aim of this study is to identify the most common water quality problems in Asian countries and to enumerate and analyze the methodologies used for assessment of water quality conditions of both rivers and confined water bodies (lakes and reservoirs). Based on the evaluation of a sample of 57 papers, dated between 2000 and 2012, it was found that over the past decade, the water quality of rivers, lakes, and reservoirs in developing countries is being degraded. Water pollution and destruction of aquatic ecosystems have caused massive damage to the functions and integrity of water resources. The most widespread NPS in Asian countries and those which have the greatest spatial impacts are urban runoff and agriculture. Locally, mine waste runoff and rice paddy are serious NPS problems. The most relevant point pollution sources are the effluents from factories, sewage treatment plant, and public or household facilities. It was found that the most used methodology was unquestionably the monitoring activity, used in 49 of analyzed studies, accounting for 86%. Sometimes, data from historical databases were used as well. It can be seen that taking samples from the water body and then carry on laboratory work (chemical analyses) is important because it can give an understanding of the water quality. 6 papers (11%) used a method that combined monitoring data and modeling. 6 papers (11%) just applied a model to estimate the quality of water. Modeling is a useful resource when there is limited budget since some models are of free download and use. In particular, several of used models come from the U.S.A, but they have their own purposes and features, meaning that a careful application of the models to other countries and a critical discussion of the results are crucial. 5 papers (9%) focus on a method combining monitoring data and statistical analysis. When there is a huge data matrix, the researchers need an efficient way of interpretation of the information which is provided by statistics. 3 papers (5%) used a method combining monitoring data, statistical analysis and modeling. These different methods are all valuable to evaluate the water quality. It was also found that the evaluation of water quality was made as well by using other types of sampling different than water itself, and they also provide useful information to understand the condition of the water body. These additional monitoring activities are: Air sampling, sediment sampling, phytoplankton sampling and aquatic animal tissues sampling. Despite considerable progress in developing and applying control regulations to point and NPS pollution, the pollution status of rivers, lakes, and reservoirs in Asian countries is not improving. In fact, this reflects the slow pace of investment in new infrastructure for pollution control and growing population pressures. Water laws or regulations and public involvement in enforcement can play a constructive and indispensable role in environmental protection. In the near future, in order to protect water from further contamination, rapid action is highly needed to control the various kinds of effluents in one region. Environmental remediation and treatment of industrial effluent and municipal wastewaters is essential. It is also important to prevent the direct input of agricultural and mine site runoff. Finally, stricter environmental regulation for water quality is required to support protection and management strategies. It would have been possible to get further information based in the 57 sample of papers. For instance, it would have been interesting to compare the level of concentrations of some pollutants in the diferente Asian countries. However the limit of three months duration for this study prevented further work to take place. In spite of this, the study objectives were achieved: the work provided an overview of the most relevant water quality problems in rivers, lakes and reservoirs in Asian countries, and also listed and analyzed the most common methodologies.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
Foi realizado um estudo sobre o efeito do tipo de fluidos na transferência de calor. Pretende-se determinar a influência da concentração da solução de Goma de Xantano, do número de Reynolds, do número de Weissenberg, da temperatura e do tempo de escoamento no coeficiente de transferência de calor, jH. O estudo da transferência de calor foi feito num permutador de tubos duplos concêntricos. Já o estudo da reologia foi realizado num reómetro. Na caracterização reológica das soluções de XG, a viscosidade aumenta com a concentração das soluções, diminui para taxas de deformação crescentes e com o aumento da temperatura para ambas as soluções. Os dados mostram um aumento da intensidade da pseudoplasticidade com a concentração do polímero, sendo os valores representados pelo modelo de Sisco. A degradação da solução de 0,20% de goma de xantano a 25 ºC, com o escoamento, é muito acelerada. Os resultados dos ensaios apresentam uma diminuição da viscosidade de 9,4% a 22,9%, para tempos de escoamento de 12 a 47 horas, respectivamente. Num escoamento turbulento em conduta de secção circular constante os resultados mostram uma redução de arrasto total de 18 para 33%. Para a solução de 0,10 % de XG, verifica-se um aumento do calor transferido de 115% e de 130%, quando a temperatura aumenta de 25 ºC para 36 ºC, respectivamente. A água apresenta valores de calor transferido superiores, cerca de 170%, aos da solução de 0,1 %XG. O factor de correlação empírico de Colbourn (jH), utilizado neste trabalho apresenta valores de acordo com a relação de Cho and Hartnett (1985): jH<2/f. Quando o caudal do fluido quente aumenta verifica-se uma diminuição do factor jH. Em relação ao tempo de escoamento verifica-se uma diminuição de cerca de 70% do coeficiente de transferência de calor ao fim de 47 horas. Finalmente verificamos uma diminuição do factor de transferência de calor com o aumento da temperatura do fluido quente, para ambas as concentrações de goma de xantano. Para as soluções de 0,10 e 0,20% de XG essa diminuição variou entre 38 e 15% e entre 34 e 3%, respectivamente.
Resumo:
Relatório de Estágio para obtenção do grau de Mestre em Engenharia na Área de Especialização em Edificações
Resumo:
Neste trabalho é abordado o estágio efectuado por um período de sete meses na E.A. (Engenheiros Associados) e um estudo de caso sobre as tecnologias aplicadas no isolamento térmico de paredes exteriores. Na primeira parte deste relatório é efectuada uma breve caracterização da empresa e da sua actividade no mercado. A Engenheiros e Associados tem a sua estrutura assente nos seguintes sectores: Técnico-Comercial, de Aprovisionamento e de Gestão Administrativa; da qual foi efectuada uma descrição do trabalho desenvolvido em cada um desses sectores, nomeadamente a permanência na obra e as visitas e diligências às obras. A segunda parte deste relatório, que é a parte fulcral do trabalho desenvolvido, assenta sobre o sistema de ETICS (External Thermal Insulation Composite System), ou seja, o sistema de reboco delgado armado sobre isolamento térmico. Foi utilizado o sistema Cappotto na Obra de Requalificação da Urbanização de Vila d’Este – 1ª Fase. Após uma breve apresentação e evolução da história do ETICS ao longo do tempo, é exposta a caracterização da obra onde vai ser aplicado o sistema, que recai sobre a tipologia dos edifícios. Refira-se que, neste relatório, os edifícios por serem de construção túnel se dividem em três tipos: tipo plana ou corrente, tipo ângulo e tipo topo. Na Analise de Patologias efectuada evidenciam-se as fissuras e a humidade presentes em quase toda a extensão dos referidos edifícios antes do tratamento, tornando-as assim as principais anomalias destes edifícios. Foram elemento de foco as anomalias existentes nos edifícios, como: Deterioração do fibrocimento; Insuficiência das caleiras; Deficiências das impermeabilizações; Ausência de rufos; Deficiência das ligações; Degradação do revestimento e pintura; Fissuração do reboco; Degradação dos forros exteriores; Deterioração das padieiras; Deterioração dos peitoris; Deterioração das juntas de dilatação; Infiltrações e condensações; Ruptura das canalizações; Deslocamentos; Deficiências de ventilação; Deficiências de estanqueidade; Inexistência de Sistema de combate a incêndios. Para estas patologias são apresentadas as propostas de solução de forma a eliminar as mesmas. Sendo o ETICS escolhido por ser o sistema que elimina a maior parte destas patologias, tendo em conta uma relação de qualidade/preço, é abordada de uma forma detalhada e extensiva da aplicação do sistema antes, durante e depois da obra em si. Assim como, é feita uma descrição pormenorizada do material utilizado para a implementação do sistema. A análise dos pontos críticos refere-se a zonas sensíveis onde há a necessidade de reforço do sistema com vista a eliminar o aparecimento posterior de patologias, como por exemplo as características de suporte. Após a aplicação do sistema podem aparecer algumas patologias das quais se destaca o facto dos produtos serem preparados em obra, o erro humano nas dosagens do fabricante e no acrescento de água sem necessidade e a par das condições climatéricas, são as causas mais comuns do aparecimento de anomalias no sistema de ETICS, provocando fissurações e infiltrações, que são descritas neste relatório. É também abordada a manutenção e reparação do sistema, onde a manutenção refere-se à lavagem e à remoção de microorganismos das paredes e posterior pintura. A reparação dos danos divide-se em dois tipos, áreas até 2 cm2 e áreas maiores que 2 cm2. Por fim, são apresentados alguns rendimentos, que foram possíveis obter ao longo do desenvolvimento do trabalho, dos materiais e da mão-de-obra, dando origem aos custos directos. Sendo também abordadas as vantagens e desvantagens do sistema desde o seu início até à sua conclusão.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores.Área de Especialização de Sistemas Autónomos
Resumo:
The erosion depth profile of planar targets in balanced and unbalanced magnetron cathodes with cylindrical symmetry is measured along the target radius. The magnetic fields have rotational symmetry. The horizontal and vertical components of the magnetic field B are measured at points above the cathode target with z = 2 x 10(-3) m. The experimental data reveal that the target erosion depth profile is a function of the angle. made by B with a horizontal line defined by z = 2 x 10(-3) m. To explain this dependence a simplified model of the discharge is developed. In the scope of the model, the pathway lengths of the secondary electrons in the pre-sheath region are calculated by analytical integration of the Lorentz differential equations. Weighting these lengths by using the distribution law of the mean free path of the secondary electrons, we estimate the densities of the ionizing events over the cathode and the relative flux of the sputtered atoms. The expression so deduced correlates for the first time the erosion depth profile of the target with the angle theta. The model shows reasonably good fittings to the experimental target erosion depth profiles confirming that ionization occurs mainly in the pre-sheath zone.