872 resultados para Masa muscular


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The myotonic dystrophy (MD) is a multisystem neuromuscular disease that can affect the respiratory muscles and heart function, and cause impairment in quality of life. Objectives: Investigate the changes in respiratory muscle strength, health-related quality of life (HRQoL) and autonomic modulation heart rate (HR) in patients with MD. Methods: Twenty-three patients performed assessment of pulmonary function, sniff nasal inspiratory pressure (SNIP), the maximal inspiratory (MIP) and expiratory (MEP) pressure, and of HRQoL (SF-36 questionnaire). Of these patients, 17 underwent assessment of heart rate variability (HRV) at rest, in the supine and seated positions. Results: The values of respiratory muscle strength were 64, 70 and 80% of predicted for MEP, MIP, and SNIP, respectively. Significant differences were found in the SF-36 domains of physical functioning (58.7 ± 31,4 vs. 84.5 ± 23, p<0.01) and physical problems (43.4 ± 35.2 vs. 81.2 ± 34, p<0.001) when patients were compared with the reference values. Single linear regression analysis demonstrated that MIP explains 29% of the variance in physical functioning, 18% of physical problems and 20% of vitality. The HRV showed that from supine position to seated, HF decreased (0.43 x 0.30), and LF (0.57 x 0.70) and the LF/HF ratio (1.28 x 2.22) increased (p< 0.05). Compared to healthy persons, LF was lower in both male patients (2.68 x 2.99) and women (2.31 x 2.79) (p< 0.05). LF / HF ratio and LF were higher in men (5.52 x 1.5 and 0.8 x 0.6, p <0.05) and AF in women (0.43 x 0.21) (p< 0.05). There was positive correlation between the time of diagnosis and LF / HF ratio (r = 0.7, p <0.01). Conclusions: The expiratory muscle strength was reduced. The HRQoL was more impaired on the physical aspects and partly influenced by changes in inspiratory muscle strength. The HRV showed that may be sympathetic dysfunction in autonomic modulation of HR, although with normal adjustment of autonomic modulation during the change of posture. The parasympathetic modulation is higher in female patients and sympathetic tends to increase in patients with longer diagnosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of evaluating the respiratory muscles with a variety of tests has been proposed by several studies, once that the combination of several tests would allow a better diagnosis and therefore, a better clinical follow of disorders of the respiratory muscles. This study aimed to evaluate the feasibility of adapting a national electronic manovacuometer to measure the nasal inspiratory pressure (study 1) and analyze the level of load intensity of maximum voluntary ventilation, as well as the variables that may influence this maneuver in healthy subjects (study 2). We studied 20 healthy subjects by a random evaluation of two measures of SNIP in different equipments: a national and an imported. In study 2 it was analyzed the intensity of the load of MVV test, change in pressure developed during the maneuver, the possible differences between genders, and the correlations between the flow developed in the test and the result of MVV. In study 1 it was found the average for both measures of nasal inspiratory pressures: 125 ± 42.4 cmH2O for the imported equipment and 131.7 ± 28.7 cmH2O for the national one. Pearson analysis showed a significant correlation between the average, with a coefficient r = 0.63. The average values showed no significant differences evaluated by paired t test (p> 0.05). In the Bland-Altman analysis it was found a BIAS = 7 cmH2O, SD 32.9 and a confidence interval of - 57.5 cmH2O up to 71.5 cmH2O. In the second study it was found significant differences between the genders in the air volume moved, being higher in males 150.9 ± 13.1 l / min vs 118.5 ± 15.7 L / min for (p = 0.0002, 95% CI 44.85 to 20:05). Regarding the inspiratory and expiratory loading, they were significantly higher in men than in women, peak inspiratory pressure (34.7 ± 5.3 cmH2O vs 19.5 ± 4.2 cmH2O, 95% CI - 18.0 to -12.3, p <0.0001), peak expiratory (33.8 vs. 23.1 ± 5.9 cmH2O ± 5.4 cmH2O, 95% CI -17.1 to - 4.6, p <0.0001), and the delta pressure (59.7 ± 10 cmH2O vs 36.8 ± 8.3 cmH2O, 95% CI 14.5 to 31.2, p <0.0002). The Pearson correlation showed that the flow generated by the maneuver is strongly correlated with the delta-expiratory pressure / inspiratory (r2= 0.83,R = 0.91, 95%IC 0.72 a 0.97 e p< 0.0001).Through these results we suggest that the national electronic manovacuometer is feasible and safe to perform the sniff test in healthy subjects. For the MVV, there are differences between the genders in the intensity of pressure developed during the maneuver. We found a load intensity considered low during the MVV, and found a strong correlation between the flow generated in the test and the delta pressure expiratory / inspiratory

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity may affect the respiratory system, causing changes in respiratory function and in the pulmonary volumes and flows. Objectives: To evaluate the influence of obesity in the movement of thoracoabdominal complex at rest and during maximal voluntary ventilation (MVV), and the contribution between the different compartments of this complex and the volume changes of chest wall between obese and non-obese patients. Materials and Methods: We studied 16 patients divided into two groups: the obese group (n = 8) and group non-obese (n = 8). The two groups were homogeneous in terms of spirometric characteristics (FVC mean: 4.97 ± 0.6 L - 92.91 ± 10.17% predicted, and 4.52 ± 0.6 L - 93.59 ± 8.05%), age 25.6 ± 5.0 and 26.8 ± 4.9 years, in non-obese and obese respectively. BMI was 24.93 ± 3.0 and 39.18 ± 4.3 kg/m2 in the groups investigated. All subjects performed breathing calm and slow and maneuver MVV, during registration for optoelectronic plethysmography. Statistical analysis: we used the unpaired t test and Mann-Whitney. Results: Obese individuals had a lower percentage contribution of the rib cage abdominal (RCa) during breathing at rest and VVM. The variation of end expiratory (EELV) and end inspiratory (EILV) lung volumes were lower in obese subjects. It has been found asynchrony and higher distortion between compartments of thoracoabdominal complex in obese subjects when compared to non-obese. Conclusions: Central obesity impairs the ventilation lung, reducing to adaptation efforts and increasing the ventilatory work

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Pilates Method is a modality of exercise that has been growing in recent decades, but few researches has been conducted with elderly and little is known about its benefits in this population. Objective: To evaluate the effect of a program of Mat Pilates exercises in muscle performance and postural balance in elderly women. Materials and Method: This is a randomized controlled trial that evaluated the muscle performance (isokinetic dynamometer Biodex System 3 Pro®) and postural balance (Balance Master System®) of 33 women aged 65-80 years. The experimental group (EG) participated of a 12-week program of Mat Pilates exercises with two weekly sessions. Data normality was verified by the Shapiro - Wilk test and were adopted p value < 0.05 as significance level. Results: There were no differences between groups after training. However, the EG showed an increase in the values of extension and flexion average power to 60 ° / s after training (32.19 W to 37.04 W and 14.48 W to 17.56 W, respectively). Conclusion: The proposed exercise program was not effective in the total work and average power of flexor and extensor of the knee, as well as static and dynamic balance of participants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In asthmatic, the lung hyperinflation leaves the inspiratory muscle at a suboptimal position in length-tension relationship, reducing the capacity of to generate tension. The increase in transversal section area of the inspiratory muscles could reverse or delay the deterioration of inspiratory muscle function. Objective: To evaluate the evidence for the efficacy of inspiratory muscle training (IMT) with an external resistive device in patients with asthma. Methods: A systematic review with meta-analysis was carried out. The sources researched were the Cochrane Airways Group Specialised Register of trials, Cochrane Central Register of Controlled Trials (The Cochrane Library Issue 11 of 12, 2012), MEDLINE, EMBASE, PsycINFO, CINAHL, AMED, ClinicalTrials.gov and reference lists of articles. All databases were searched from their inception up to November 2012 and there was no restriction on the language of publication. Randomised controlled trials that involved the use of an external inspiratory muscle training device versus a control (sham or no inspiratory training device) were considered for inclusion. Two reviewers independently selected articles for inclusion, evaluated risk of bias in studies and extracted data. Results: A total of five studies involving 113 asthmatic patients were included. Three clinical trials were produced by the same group. The included studies showed a significant increase in maximal inspiratory pressure (MD 13.34 cmH2O, 95% CI 4.70 to 21.98), although the confidence intervals were wide. There was no statistically significant difference between the IMT group and the control group for maximal expiratory pressure, peak expiratory flow rate, forced expiratory volume in one second, forced vital capacity, sensation of dyspnea and use of beta2-agonist. There were no studies describing exacerbation events that required a course of oral and inhaled corticosteroids or emergency department visits, inspiratory muscle endurance, hospital admissions and days of work or school. Conclusions: There is no conclusive evidence in this review to support or refute inspiratory muscle training for asthma, once the evidence was limited by the small number of studies included, number of participants in them together with the risk of bias. More well conducted randomized controlled trials are needed, such trials should investigate respiratory muscle strength, exacerbation rate, lung function, symptoms, hospital admissions, use of medications and days off work or school. IMT should also be assessed in the context of more severe asthma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A obesidade é uma epidemia global em alarmante ascensão. Caracterizada pelo excesso de gordura corporal subcutânea, de caráter multifatorial, está relacionada ao surgimento de diversas co-morbidades, entre elas, várias alterações respiratórias, estas se tornam mais intensas quanto maior o grau de obesidade. Não há consenso na relação entre os marcadores de adiposidade geral ou específicos e suas repercussões sobre a função ventilatória, especialmente em relação à sobrecarga muscular respiratória. Objetivo: Analisar a relação entre marcadores antropométricos e variáveis espirométricas e de força muscular respiratória em indivíduos com obesidade mórbida. Métodos: Estudo transversal entre setembro de 2007 e outubro de 2012. Participaram da pesquisa 163 obesos mórbidos (37.1±9.8 anos e IMC=49.0±5.88 Kg/m2) sem alterações espirométricas. Foram observadas as associações entre Índice de Massa Corporal-IMC, adiposidade localizada (Circunferências de Pescoço-CP, Cintura-CC e Quadril-CQ), percentual de gordura corporal através do Índice de Adiposidade Corporal-IAC, volumes e capacidades pulmonares (CVF, VEF1 e VRE) e pressões respiratória estática (PIM e PEM) e dinâmica (VVM). Resultados: O VRE foi o volume mais afetado pela obesidade (apenas 41%predito) e mostrou associação negativa nas relações com todos os marcadores de adiposidade (IMC: r=-0.52; IAC: r=-0.21; CC: r=-0.44; CP: r=-0.25 e CQ: r=-0.28). Há relação inversa entre o percentual de gordura corporal (IAC) com a CVF (r=-0.59), o VEF1(r=-0.56) e o VVM (r=-0.43). As pressões respiratórias são justificadas principalmente pela adiposidade ao redor do pescoço e o IAC. Nossos dados de força muscular respiratória foram melhores associados aos valores de referências sugeridos pelas equações de Harik-Klan et al (1998) para PIM (R²=0.72) e com a equação proposta por Neder et al (1999) para PEM (R²=0.52). Em um modelo de regressão linear, as variáveis de adiposidade não justificam a VVM, já o VEF1 explica 62% da variância da VVM em obesos mórbidos. Conclusão: O percentual da adiposidade corporal e a circunferência do pescoço estão associados com a força muscular e capacidade de gerar fluxo respiratório de obesos mórbidos. Sugerimos a equação elaborada por Harik-Klan et al (1998) para obtenção de valores preditos de PIM e a equação proposta por Neder et al (1999) para valores de normalidade da PEM em sujeitos com obesidade mórbida. Foi possível fornecer uma equação de referência específica para VVM em obesos mórbidos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aging process modifies various systems in the body, leading to changes in mobility, balance and muscle strength. This can cause a drop in the elderly, or not changing the perceived self-efficacy in preventing falls. Objective: To compare the mobility, body balance and muscle performance according to self-efficacy for falls in community-dwelling elderly. Methods: A cross-sectional comparative study with 63 older (65-80 years) community. Were evaluated for identification data and sociodemographic, cognitive screening using the Mini Mental State Examination (MMSE), effective for the fall of Falls Efficacy Scale International Brazil (FES-I-BRAZIL), Mobility through the Timed Up and Go Test , the balance Berg Balance Scale (BBS) and the Modified Clinical Test tests of Sensory Interaction on Balance (mCTSIB), tandem walk (TW) and Sit to Stand (STS) of the Balance Master® System. Finally, muscle performance by using isokinetic dynamometry. Statistical analysis was performed Student t test for comparison between groups, with p value ≤ 0.05. Results: Comparing the elderly with low-efficacy for falls with high-efficacy for falls, we found significant differences only for the variable Timed Up and Go Test (p = 0.04). With regard to data on balance tests were significant differences in the speed of oscillation firm surface eyes open modified Clinical Test of Sensory Interaction on Test of Balance (p = 0.01). Variables to isokinetic dynamometry were no significant differences in movement knee extension, as regards the variables peak torque (p = 0.04) and power (p = 0.03). Conclusion: The results suggest that, compared to older community with low-and high-efficacy for falls, we observed differences in variables related to mobility, balance and muscle function

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asthma treatment aims to achieve and maintain the control of the disease for prolonged periods. Inspiratory muscle training (IMT) may be an alternative in the care of patients with asthma, and it is used as a complementary therapy to the pharmacological treatment. Thus, the aim of this study was to investigate the effects of a domiciliary program of IMT on the electromyographic activity of the respiratory muscles in adults with asthma. This is a clinical trial in which ten adults with asthma and ten healthy adults were randomized into two groups (control and training). The electrical activity of inspiratory muscles (sternocleidomastoid (ECM) and diaphragm) was obtained by a surface electromyography. Furthermore, we assessed lung function (spirometry), maximal inspiratory pressure - MIP - (manometer). The functional capacity was evaluated by six minute walk test. Participants were assessed before and after the IMT protocol of 6 weeks with POWERbreathe® device. The training and the control groups underwent IMT with 50% and 15 % of MIP, respectively. The sample data were analyzed using SPSS 20.0, attributing significance of 5 %. Were used t test, ANOVA one way and Pearson correlation. It was observed an increase in MIP, after IMT, in both training groups and in healthy sham group (P < 0.05), which was accompanied by a significant increase in ECM activity during MIP in healthy training group (1488 %) and in asthma training group (ATG) (1186.4%). The ATG also showed a significant increase in diaphragm activity in basal respiration (48.5%). Functional capacity increased significantly in the asthma sham group (26.5 m) and in the asthma training group (45.2 m). These findings suggest that IMT promoted clinical improvements in all groups, especially the ATG, which makes it an important complementary treatment for patients with asthma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exercise-induced muscle damage mainly affects individuals who returned to physical activity after a time without practicing it or had some kind of exhaustive exercise, particularly eccentric exercise. To evaluate the effect of cryotherapy and laser therapy in response to muscle damage induced by eccentric exercise on the biceps muscle. This was a randomized clinical trial consisting of 60 female subjects. All subjects initially underwent an evaluation consisting of perimetry, measurement of pain sensation (via algometry and visual analogue scale), electromyography and dynamometry. Then the subjects performed an exercise protocol on the isokinetic dynamometer consisting of 2 sets of 10 eccentric elbow flexors contraction at 60 °/s. Completed this protocol, an intervention was held according to a previously random group distribution: control group (no intervention), cryotherapy group and laser therapy group. Finally, subjects were re-evaluated immediately and 48 hours after the intervention protocol, except for Visual Analogue Scale (VAS), which was also evaluated 24 hours after exercise. The circumference of the limb, the pain sensation (VAS and algometry), the muscle activation amplitude (via Root Mean Square - RMS), median frequency, peak torque normalized per body weight, average peak torque, power and work were analyzed. The median frequency immediately after the intervention protocol on the cryotherapy group was the only variable that showed inter and intra-group differences; the remaining variables showed only intragroup differences. The perimetry values did not change immediately after the protocol on the groups which underwent cryotherapy and laser therapy, however, there was an increase after 48 hours; algometry values decreased in all groups for 48 hours and the VAS values increased 24 and 48 hours also for all groups. Regarding RMS no significant change was observed. For dynamometry, peak torque normalized per body weight and average peak torque had a similar behavior, with a reduction in the post protocol that has remained after 48 hours. For the power and work, a decrease was observed immediately after the protocol with a further reduction after 48 hours. Cryotherapy and laser therapy does not alter the muscle damage response, except for the perimetry values immediately after exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Hypoestrogenism is the main characteristic of female aging. It promotes significant changes in body composition, both in fat mass as in lean body mass, leading to a decrease in muscle strength and physical performance. Objective: The aim of this study was to test whether menopausal status and hormone levels are associated with muscular strength and physical performance in middle-aged women. Methods: In a cross-sectional study it was collected sociodemographic data, gynecological history, anthropometric and biochemical measures in women aged 40 to 65 years in Parnamirim-RN. The menopause status (pre, peri and post menopause) was determined by menstrual history. All women underwent three dimensions of physical performance assessment: handgrip dynamometry, gait speed and chair stands test - Short Physical Performance Battery (SPPB). Categorical data were presented as absolute and relative frequencies. Quantitative data were showed as mean and standard deviation and the normality of distribution was verified with Kolmogorov-Smirnov (KS) test. Biochemical measures of estradiol and follicle-stimulating hormone (FSH) were transformed to log10. ANOVA with Tukey post-test for comparison of variables between the groups pre, peri and post-menopausal was performed and then multiple linear regression analyzes. Results: Two hundred and seventy eight women aged 50.2 (±5.58) years composed this study, being 50 women in premenopausal status (18%), 122 in perimenopausal (43.9%), and 106 postmenopausal stage (38.1%). The groups were different in age (p=0.001), marital relationship duration (p <0.001), number of pregnancies (p=0.001) and parity (p=0.001). Differences in biochemical measures were observed among the groups: estradiol (p<0.001), FSH (p<0.001), total cholesterol (p=0.001). There were no differences in gait velocity between menopausal status. Values in mean of grip strength decreased by postmenopausal women to perimenopausal and premenopausal ones (24.5 ± 5.1, 25.6 ± 5.4, 26.9 ± 4.9 for post-stage, pre and peri menopausas, respectively, p = 0.02) and the performance of chair stands test was better in premenopausal women compared with that in peri and postmenopausal status (p = 0.02). In multiple linear regression for muscle strength, the variables that remained were: age, estradiol and somatic symptoms measured by Menopause Rating Scale-MRS (R2=0.15). While for the xiv chair-stands test the predictors were number of births and FSH values (R2=0.04). Conclusion: There is a relationship between the stages of menopause and muscle performance in measures of grip strength and sit-up test and these are influenced by the fall of estrogens levels. Data suggest that the decrease in muscle strength and physical performance already appear in the transition to menopause stage, pointing to the need for more research in this area and appropriate preventive interventions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of increased protein intake on the muscle mass gain, nitrogen balance and N-15-glycine kinetics was studied in six young, healthy subjects practitioners of strength training (> 2 years), without use of anabolic steroids and in agreement with the ethical principles of the research. All athletes received adequate diet (0.88g protein/kg/day) during 2 weeks prior the study (D1), and thereafter with diet providing 1.5g of protein/kg/day and 30kcal/g of protein (D2 diet) for the subsequent 2 weeks. Later on, they all received diet with 2.5g of protein/kg/day (D3 diet) and 30 kcal/g protein for the last two weeks. Body composition, food intake, blood biochemistry, nitrogen balance (NB) and 15N-glycine kinetics were determined at the beginning, after D1 (M0) and in the last days of the D2 (M1) and D3 (M2). The results showed at the end of the study (4 weeks) significant increase in muscle mass (1.63 +/- 0.9kg), without difference between D2 and D3. The NB followed the protein/energy consumption (M0 = -7.8g/day; M1 = 5.6g/day and D3 = 16.6g/day), the protein synthesis followed the NB, with M0 < (M1= M2) (M1 = 49.8 +/- 12.2g N/day and M2 = 52.5 +/- 14.0g N/day). Protein catabolism rate was similarly kept among diets. Thus, the results of the NB and N-15-glycine kinetics indicate that the recommended protein intake for these athletes is higher than the one for sedentary adults (0.88g/kg) and lower than 2.5g/kg, around 1.5g of protein/kg/day, with adjustment of the energy consumption to 30 kcal/g of protein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Há algum tempo o condicionamento físico vem sendo parte obrigatória no tratamento de portadores de DPOC. Estes pacientes apresentam comumente intolerância ao exercício de intensidade variável e relacionada à disfunção muscular esquelética. Neste sentido, o exercício físico apresenta-se como ramo mais importante no processo de reabilitação pulmonar. O exercício aeróbio e o treino de força com pesos são fundamentais no incremento de capacidade física e qualidade de vida, principalmente naqueles indivíduos que apresentam as formas moderada ou grave da DPOC. Além disso, espera-se atualmente maior desenvolvimento nas pesquisas em relação à aplicação de estimulação elétrica neuromuscular (EENM) e ao uso criterioso de substâncias ergogênicas tais como esteróides anabolizantes e creatina oral. Tendo em vista as repercussões negativas da disfunção muscular e a importância da reabilitação pulmonar no tratamento da DPOC, esta revisão tem como objetivo reunir informações de estudos relevantes acerca das principais estratégias para o recondicionamento muscular esquelético nestes pacientes nos últimos 15 anos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: analisar a influência da via de parto sobre a força muscular do assoalho pélvico (FM-AP). MÉTODOS: estudo clínico de corte transversal, para avaliar a FM-AP pelo teste da avaliação da força do assoalho pélvico (AFA) e uso do perineômetro em primíparas, entre 20-30 anos de idade, 4-6 meses pós-parto. A contração, medida pelos dois testes, foi classificada em: zero - ausência, um - leve, dois - moderada e três - normal, sustentada por 6 segundos. Avaliaram-se 94 mulheres, entre 20 e 30 anos, divididas em três grupos: pós-parto vaginal (n=32); pós-cesárea (n=32) e nulíparas (n=30). A variável independente foi a via de parto e a dependente, a FM-AP. A comparação entre os graus de contração foi realizada pelo teste de Kruskal-Wallis e o teste de Dunn para comparações múltiplas; a influência da via de parto pelo teste chi2, o risco relativo (RR) para alteração da FM-AP e o coeficiente kappa para avaliar equivalência entre os testes. RESULTADOS: a mediana e 1º e 3º quartil da FM-AP foram menores (p=0,01) pós-parto vaginal (2,0;1-2) e intermediários pós-cesárea (2,0; 2-3) em relação às nulíparas (3,0;2-3), tanto analisadas pelo AFA como pelo perineômetro. Aumentou o RR de exame alterado pós-parto vaginal (RR=2,5; IC 95%: 1,3-5,0; p=0,002); (RR=2,3; IC 95%: 1,2-4,3; p=0,005) e pós-cesárea (RR=1,5; IC 95%: 0,94-2,57; p=0,12); (RR=1,3; IC 95%: 0,85-2,23; p=0,29) pelo PFSE e perineômetro, respectivamente. CONCLUSÕES: o parto vaginal diminuiu a força muscular do AP de primíparas quando comparado com os casos submetidos à cesárea e com as nulíparas.