929 resultados para ISO 15489 Standard
Resumo:
A test chamber was projected and built (according to ISO 16000-9 Standard) to simulate atmospheric conditions experienced by rubber infill (when applied in synthetic turf pitches) and measure accurately the airborne emissions of pollutants such as dusts and volatile organic compounds (VOC), as well as pollutants present in leachates. It should be pointed out that standard ISO 16000-9 is only concerned with the determination of the emission of VOC from building products and furnishing (not specific of synthetic turf materials), whereas other standards are concerned with the emission of leachates only. This procedure is to be considered as a technical option to the lysimeter "global turf system evaluation" when the rubber infill alone is to be evaluated. The advantage of the proposed option considering this "test chamber" is its simplicity and economy. This test chamber is actually installed and being used for tests in LAIST.
Resumo:
No mundo atual, as empresas têm que ser cada vez mais competitivas. Para poder concorrer e ser competitivo em qualquer mercado do mundo, é mandatório ter um produto da melhor qualidade e ao melhor preço, mediante o público-alvo a que este se destina, uma vez que a população está cada vez melhor informada e mais exigente. Para obtenção de um produto final de melhor qualidade, são necessárias a qualificação e bemestar da mão-de-obra, assim como de todos os restantes intervenientes, assim como, produtos de qualidade, sempre com o objetivo de fornecer um melhor produto ao cliente. Como modelo padronizado de gestão de qualidade surge a ISO 9000, passível de ser utilizado por qualquer organização, que ao longo dos tempos tem recebido alterações sempre numa perspetiva de melhoria, como a própria norma nos aconselha. O objetivo desta dissertação é estudar e implementar a ISO 9000 (no caso, a sua versão mais recente ISO 9001:2008) numa empresa de construção civil com todos os seus requisitos, podendo assim verificar, na prática, em que moldes se concretiza a aplicação da ISO 9000 à referida área. A norma em questão é implementada numa empresa de construção civil real, na vertente de construção de edificações, sediada em Recife, PE – Brasil. Assim, nesta dissertação, abordar-se-á e implementar-se-á um modelo de organização para uma empresa de construção civil, segundo a Norma ISO 9001:2008, na sua versão Brasileira ANBT NBR ISO 9001:2008.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.
Resumo:
Several activities are ensured by dockers increase occupational exposure to several risk factors. being one of them the fungal burden from the load. In this study we aim at characterizing fungal contamination in one warehouse that storage sugar cane from a ship, and also in one crane cabinet that unload the same sugar cane from the ship. Air samples were collected from the warehouse and from inside the crane cabinet. An outdoor sample was also collected, from each sampling site, and regarding as reference. Sampling volume was selected depending in the contamination expected and the air samples were collect through an impaction method in a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore). Surfaces samples from the warehouse were collected by swabbing the surfaces of the same indoor sites, using a 10 by 10cm square stencil according to the International Standard ISO 18593 (2004). The obtained swabs were then plated onto MEA. All the collected samples were incubated at 27ºC for 5 to 7 days. After laboratory processing and incubation of the collected samples, quantitative (colony-forming units - CFU/m3 and CFU/m2) and qualitative results were obtained with identification of the isolated fungal species. Aspergillus fumigatus present the highest fungal load and WHO guideline was overcome in both indoor sampling sites. The results obtained in this study highlight the need to know better the exposure burden from dockers, and specifically to fungi contamination.
Resumo:
Dissertação de natureza científica para obtenção do grau de mestre em Engenharia Civil
Resumo:
Esta dissertação de Mestrado pretende, numa primeira fase, identificar as condições gerais e os pressupostos da aplicação da ferramenta Análise do Valor (AV) e integrá-la nos Sistemas de Gestão da Qualidade. Pretende-se demonstrar a técnica e aumentar o seu conhecimento, assim como as várias abordagens do processo, as vantagens e os constrangimentos no seu uso, conduzir à ideia que poderá ser útil proceder a uma análise organizada e sistemática dos produtos/serviços existentes nas organizações, abrindo a hipótese a novas soluções para o produto/serviço de mais fácil produção/realização e ensaio ao menor custo. É realçada a importância do conceito da Análise do Valor demonstrando que se pode tornar numa ferramenta eficaz na melhoria dos produtos mas também de processos de fabrico e até em processos administrativos. Sendo a Qualidade entendida como um conjunto de características que um bem, produto ou serviço possui que o tornam apto para satisfazer na plenitude uma dada necessidade do seu utilizador, este trabalho também faz a ligação com os Sistemas de Gestão da Qualidade comparando dois referenciais, a Norma NP EN 12973 e a ISO 9001:2008. Numa segunda fase é realizada uma profunda abordagem à ferramenta QFD – Quality Function Deployment – como uma técnica complementar à aplicação prática da técnica AV e é realizado um estudo a um serviço pós-venda que inclui muitos dos seus conceitos e princípios. O trabalho foi realizado na empresa onde sou colaborador há cerca de 10 anos exercendo o cargo de “Service Manager Press/Post Press” ao departamento de serviço técnico e apoio ao cliente. Foi muito útil a demonstração prática para entendimento das dificuldades sentidas e dos obstáculos a ultrapassar. O trabalho termina com as conclusões do caso prático e as conclusões gerais, mencionando as definições dos aceleradores / obstáculos da aplicação da AV.
Resumo:
Perante a crescente preocupação dos consumidores, cada vez mais exigentes com os produtos e serviços que lhes são fornecidos, têm-se evidenciado esforços no sentido da aplicação prática e coordenada de uma abordagem global e integrada da segurança alimentar com o objectivo de melhorar as normas da qualidade e reforçar os sistemas de controlo em toda a cadeia alimentar, desde a exploração agrícola até ao consumidor final. Os referenciais normativos de segurança alimentar especificam os requisitos de um Sistema de Gestão da Segurança Alimentar, para organizações da cadeia de fornecimento de produtos alimentares, que pretendam demonstrar a sua aptidão para fornecer produtos seguros e o cumprimento de requisitos legais, regulamentares e de qualidade exigidos. Ao longo dos anos, diversos referenciais normativos, baseados na metodologia HACCP, foram desenvolvidos e publicados, por vários países e determinados sectores da cadeia alimentar. Perante a diversidade de referenciais existentes, cada vez mais, as organizações se questionam sobre qual o referencial de segurança alimentar a implementar. Nesta dissertação, dá-se uma contribuição no sentido da sistematização dos requisitos dos referenciais de segurança alimentar com o objectivo de suportar a respectiva comparação nomeadamente o IFS – Food, o BRC – Food, a FSSC 22000 e, de forma indirecta, a ISO 22000. Tal deve-se à necessidade de identificar o(s) referenciais de segurança alimentar a implementar numa dada organização pertencente a um dado sector de actividade. Finalmente, procede-se à realização de um estudo sobre a representatividade, número de empresas certificadas, dos referenciais em análise no mercado Nacional, Europeu e Internacional. Como conclusão genérica, é possível afirmar que, embora ao nível dos requisitos existam diferenças entre os referenciais em análise, também se verificam muitas semelhanças. Prova disso é o reconhecimento por parte da GFSI de vários destes referenciais Quanto à representatividade, verifica-se uma tendência de predomínio de determinados referenciais nos países onde foram desenvolvidos, e nos países com os quais mantêm relações comerciais mais fortes. Refere-se o Reino Unido para a BRC, e a Alemanha e França para a IFS. De salientar a importante contribuição da GFSI que, através do reconhecimento aos diversos referenciais de segurança alimentar, realizado por uma painel de especialistas e representantes de diversos sectores (industria, distribuição e serviços) está a contribuir para a respectiva harmonização e reconhecimento mundial.
Resumo:
A new high performance architecture for the computation of all the DCT operations adopted in the H.264/AVC and HEVC standards is proposed in this paper. Contrasting to other dedicated transform cores, the presented multi-standard transform architecture is supported on a completely configurable, scalable and unified structure, that is able to compute not only the forward and the inverse 8×8 and 4×4 integer DCTs and the 4×4 and 2×2 Hadamard transforms defined in the H.264/AVC standard, but also the 4×4, 8×8, 16×16 and 32×32 integer transforms adopted in HEVC. Experimental results obtained using a Xilinx Virtex-7 FPGA demonstrated the superior performance and hardware efficiency levels provided by the proposed structure, which outperforms its more prominent related designs by at least 1.8 times. When integrated in a multi-core embedded system, this architecture allows the computation, in real-time, of all the transforms mentioned above for resolutions as high as the 8k Ultra High Definition Television (UHDTV) (7680×4320 @ 30fps).
Resumo:
Social concerns for environmental impact on air, water and soil pollution have grown along with the accelerated growth of pig production. This study intends to characterize air contamination caused by fungi and particles in swine production, and, additionally, to conclude about their eventual environmental impact. Fiftysix air samples of 50 litters were collected through impaction method. Air sampling and particle matter concentration were performed in indoor and also outdoor premises. Simultaneously, temperature and relative humidity were monitored according to the International Standard ISO 7726 – 1998. Aspergillus versicolor presents the highest indoor spore counts (>2000 CFU/m3) and the highest overall prevalence (40.5%), followed by Scopulariopsis brevicaulis (17.0%) and Penicillium sp. (14.1%). All the swine farms showed indoor fungal species different from the ones identified outdoors and the most frequent genera were also different from the ones indoors. The distribution of particle size showed the same tendency in all swine farms (higher concentration values in PM5 and PM10 sizes). Through the ratio between the indoor and outdoor values, it was possible to conclude that CFU/m3 and particles presented an eventual impact in outdoor measurements.
Resumo:
O projeto “Avaliação da Exposição a Fungos e Partículas em Explorações Avícolas e Suinícolas” contemplou um elevado número de colheitas ambientais e biológicas e respectivo processamento laboratorial, sendo apenas possível a sua concretização graças ao financiamento disponibilizado pela Autoridade para as Condições de Trabalho. Foi realizado um estudo transversal para avaliar a contaminação causada por fungos e partículas em 7 explorações avícolas e 7 explorações suinícolas. No que concerne à monitorização biológica, foram medidos os parâmetros espirométricos, utilizando o espirómetro MK8 Microlab, avaliada a existência de sintomas clínicos associados com a asma e outras doenças alérgicas, através de questionário adaptado European Community Respiratory Health Survey e, ainda, avaliada a sensibilização aos agentes fúngicos (IgE). Foram ainda adicionados dois objetivos ao estudo, designadamente: aferir a existência de três espécies/estirpes potencialmente patogénicas/toxinogénicas com recurso à biologia molecular e avaliar a exposição dos trabalhadores à micotoxina aflatoxina B1 por recurso a indicador biológico de exposição. Foram colhidas 27 amostras de ar de 25 litros nas explorações avícolas e 56 de 50 litros nas explorações suinícolas através do método de impacto. As colheitas de ar e a medição da concentração das partículas foram realizadas no interior e no exterior dos pavilhões, sendo este último considerado como local de referência. Simultaneamente, a temperatura e a humidade relativa também foram registadas. As colheitas das superfícies foram realizadas através da técnica de zaragatoa, tendo sido utilizado um quadrado de metal inoxidável de 10 cm de lado, de acordo com a International Standard ISO 18593 – 2004. As zaragatoas obtidas (20 das explorações avícolas e 48 das explorações suinícolas) foram inoculadas em malte de extract agar (2%) com cloranfenicol (0,05 g/L). Além das colheitas de ar e de superfícies, foram também obtidas colheitas da cama das explorações avícolas (7 novas e 14 usadas) e da cobertura do pavimento das explorações suinícolas (3 novas e 4 usadas) e embaladas em sacos esterilizados. Cada amostra foi diluída e inoculada em placas contendo malte extract agar. Todas as amostras foram incubadas a 27,5ºC durante 5 a 7 dias e obtidos resultados quantitativos (UFC/m3; UFC/m2; UFC/g) e qualitativos com a identificação das espécies fúngicas. Para a aplicação dos métodos de biologia molecular foram realizadas colheitas de ar de 300 litros utilizando o método de impinger com a velocidade de recolha de 300 L/min. A identificação molecular de três espécies potencialmente patogénicas e/ou toxinogénicas (Aspergillus flavus, Aspergillus fumigatus e Stachybotrys chartarum) foram obtidas por PCR em tempo real (PCR TR) utilizando o Rotor-Gene 6000 qPCR Detection System. As medições de partículas foram realizadas por recurso a equipamento de leitura direta (modelo Lighthouse, 2016 IAQ). Este recurso permitiu medir a concentração (mg/m3) de partículas em 5 dimensões distintas (PM 0.5; PM 1.0; PM 2.5; PM 5.0; PM10). Nas explorações avícolas, 28 espécies/géneros de fungos foram isolados no ar, tendo Aspergillus versicolor sido a espécie mais frequente (20.9%), seguida por Scopulariopsis brevicaulis (17.0%) e Penicillium sp. (14.1%). Entre o género Aspergillus, Aspergillus flavus apresentou o maior número de esporos (>2000 UFC/m3). Em relação às superfícies, A. versicolor foi detetada em maior número (>3 × 10−2 UFC/m2). Na cama nova, Penicillium foi o género mais frequente (59,9%), seguido por Alternaria (17,8%), Cladosporium (7,1%) e Aspergillus (5,7%). Na cama usada, Penicillium sp. foi o mais frequente (42,3%), seguido por Scopulariopsis sp. (38,3%), Trichosporon sp. (8,8%) e Aspergillus sp. (5,5%). Em relação à contaminação por partículas, as partículas com maior dimensão foram detectadas em maiores concentrações, designadamente as PM5.0 (partículas com a dimensão de 5.0 bm ou menos) e PM10 (partículas com a dimensão de 10 bm ou menos). Neste setting a prevalência da alteração ventilatória obstrutiva foi superior nos indivíduos com maior tempo de exposição (31,7%) independentemente de serem fumadores (17,1%) ou não fumadores (14,6%). Relativamente à avaliação do IgE específico, foi apenas realizado em trabalhadores das explorações avícolas (14 mulheres e 33 homens), não tendo sido encontrada associação positiva (p<0.05%) entre a contaminação fúngica e a sensibilização a antigénios fúngicos. No caso das explorações suinícolas, Aspergillus versicolor foi a espécie mais frequente (20,9%), seguida por Scopulariopsis brevicaulis (17,0%) e Penicillium sp. (14,1%). No género Aspergillus, A. versicolor apresentou o maior isolamento no ar (>2000 UFC/m3) e a maior prevalência (41,9%), seguida por A. flavus e A. fumigatus (8,1%). Em relação às superfícies analisadas, A. versicolor foi detetada em maior número (>3 ×10−2 UFC/m2). No caso da cobertura do pavimento das explorações suinícolas, o género Thicoderma foi o mais frequente na cobertura nova (28,0%) seguida por A. versicolor e Acremonium sp. (14,0%). O género Mucor foi o mais frequente na cobertura usada (25,1%), seguido por Trichoderma sp. (18,3%) e Acremonium sp. (11,2%). Relativamente às partículas, foram evidenciados também valores mais elevados na dimensão PM5 e, predominantes nas PM10. Neste contexto, apenas 4 participantes (22,2%) apresentaram uma alteração ventilatória obstrutiva. Destes, as obstruções mais graves encontraram-se nos que também apresentavam maior tempo de exposição. A prevalência de asma na amostra de trabalhadores em estudo, pertencentes aos 2 contextos em estudo, foi de 8,75%, tendo-se verificado também uma prevalência elevada de sintomatologia respiratória em profissionais não asmáticos. Em relação à utilização complementar dos métodos convencionais e moleculares, é recomendável que a avaliação da contaminação fúngica nestes settings, e, consequentemente, a exposição profissional a fungos, seja suportada pelas duas metodologias e, ainda, que ocorre exposição ocupacional à micotoxina aflatoxina B1 em ambos os contextos profissionais. Face aos resultados obtidos, é importante salientar que os settings alvo de estudo carecem de uma intervenção integrada em Saúde Ocupacional no âmbito da vigilância ambiental e da vigilância da saúde, com o objetivo de diminuir a exposição aos dois factores de risco estudados (fungos e partículas).
Resumo:
Nem sempre são fáceis os desafios ambientais associados ao consumo de energia. Sobretudo devido à forte dependência de combustíveis fósseis, torna-se cada vez mais evidente a inevitabilidade de agentes económicos, políticos, sociedade em geral, assumirem um compromisso focado na melhoria da eficiência energética e no uso racional da energia, decorrente das atividades económicas. Esta preocupação assume-se também como nacional. A norma NP EN ISO 50001 apresenta-se como uma solução de método transversal e de harmonia internacional. Vetores como gestão eficiente de energia, consequente minimização no impacto ambiental e relevantes reduções dos custos de energia, são os pilares desta norma que certifica atividades desde o sector terciário ao industrial.
Resumo:
Mestrado em Controlo da Gestão e dos Negócios
Resumo:
The growing heterogeneity of networks, devices and consumption conditions asks for flexible and adaptive video coding solutions. The compression power of the HEVC standard and the benefits of the distributed video coding paradigm allow designing novel scalable coding solutions with improved error robustness and low encoding complexity while still achieving competitive compression efficiency. In this context, this paper proposes a novel scalable video coding scheme using a HEVC Intra compliant base layer and a distributed coding approach in the enhancement layers (EL). This design inherits the HEVC compression efficiency while providing low encoding complexity at the enhancement layers. The temporal correlation is exploited at the decoder to create the EL side information (SI) residue, an estimation of the original residue. The EL encoder sends only the data that cannot be inferred at the decoder, thus exploiting the correlation between the original and SI residues; however, this correlation must be characterized with an accurate correlation model to obtain coding efficiency improvements. Therefore, this paper proposes a correlation modeling solution to be used at both encoder and decoder, without requiring a feedback channel. Experiments results confirm that the proposed scalable coding scheme has lower encoding complexity and provides BD-Rate savings up to 3.43% in comparison with the HEVC Intra scalable extension under development. © 2014 IEEE.
Resumo:
The international Electrotechnical Commission (IEC) 61499 architecture incorporated several function block with which distributed control application may be developed, and how these are interpreted and executed. However, due the distributed nature of the control applications, many issues also need to be taken into account. Most of these are due to the new error model and failure modes of the distributed hardware on which the distributed application is executed and also due the incomplete standards definition of the execution models. IEC 61499 frameworks does not clarify how to handle with replication of software and hardware components. In this paper we propose a replication model for IEC 61499 applications and which mechanisms and protocols may be used for their support.