940 resultados para Compression Parallel to Grain tests


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently, several psychological and non-psychological tests can be found in publishes without standardization on procedures set in different psychological areas, like intelligence, emotional states, attitudes, social skills, vocation, preferences and others. The computerized psychological testing is a extension of traditional testing psychological practices. However, it has own psychometrics qualities, either by its matching in a computerized environment or by the extension that can be developed in it. The current research, developed from a necessity to study process of validity and reliability on a computerized test, drew a methodological structure to provide parallel applications in numerous kinds of operational groups, evaluating the influences of the time and approach in the computerization process. This validity refers to normative values groups, reproducibility in computerized applications process and data processing. Not every psychological test can be computerized. Therefore, our need to find a good test, with quality and plausible properties to transform in computerized application, leaded us to use The Millon Personality Inventory, created by Theodore Millon. This Inventory assesses personality according to 12 bipolarities distributed in 24 factors, distributed in categories motivational styles, cognitive targets and interpersonal relations. This instrument doesn t diagnose pathological features, but test normal and non adaptive aspects in human personality, comparing with Theodore Millon theory of personality. In oder to support this research in a Brazilian context in psychological testing, we discuss the theme, evaluating the advantages and disadvantages of such practices. Also we discuss the current forms in computerization of psychological testing and the main specific criteria in this psychometric specialized area of knowledge. The test was on-line, hosted in the site http://www.planetapsi.com, during the years of 2007 and 2008, which was available a questionnaire to describe social characteristics before test. A report was generated from the data entry of each user. An application of this test was conducted in a linear way through a national coverage in all Brazil regions, getting 1508 applications. Were organized nine groups, reaching 180 applications in test and retest subject, where three periods of time and three forms of retests for studies of on-line tests were separated. Parallel to this, we organized multi-application session offline group, 20 subjects who received tests by email. The subjects of this study were generally distributed by the five Brazilian regions, and were noticed about the test via the Internet. The performance application in traditional and on-line tested groups subsidies us to conclude that on-line application provides significantly consistency in all criteria for validity studied and justifies its use. The on-line test results were related not only among themselves but were similar to those data of tests done on pencil and paper (0,82). The retests results demonstrated correlation, between 0,92 and, 1 while multisessions had a good correlation in these comparisons. Moreover, were assessed the adequacy of operational criteria used, such as security, the performance of users, the environmental characteristics, the organization of the database, operational costs and limitations in this on-line inventory. In all these five items, there were excellent performances, concluding, also, that it s possible a self-applied psychometric test. The results of this work are a guide to question and establish of methodologies studies for computerization psychological testing software in the country

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The effect of methyl methacrylate (MMA) monomer on the bond strength of three types of denture base resins (Acron MC, Lucitone 550 and QC-20) to two types of acrylic teeth (Biotone and Trilux) was evaluated. Twenty specimens were produced for each denture base resin/acrylic tooth combination and were randomly divided into control (acrylic teeth received no surface treatment) and experimental groups (MMA was applied to the surface of the acrylic teeth for 180 s) and were submitted to shear tests (1 mm/mm). Data (MPa) were analyzed using three-way ANOVA/Student's test (alpha = 0.05). MMA increased the bond strength of Lucitone denture base resins and decreased the bond strength of QC-20. No difference was detected for the bond strength of Acron MC base resin after treatment with MMA. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymeric precursor solution (Pechini method) was used to deposit LiNbO3 thin films by spin-coating on (100) silicon substrates. X-ray diffraction data of thin films showed that the increase of oxygen flow promotes a preferred orientation of (001) LiNbO3 planes parallel to the substrate surface. Surface roughness and grain size, observed by atomic force microscopy, change also with oxygen flow.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The relationship between grain-boundary capacitance and extrinsic shallow donors caused by Nb addition to SnO2 center dot COO binary polycrystalline system has been investigated by means of combined techniques such as I-V characteristic response, complex impedance and capacitance analysis and electrostatic force microscopy. The estimated role of the Nb doping is to increase the concentration of shallow donors that are capable of enhancing the electronic donation to grain-boundary acceptors. This effect leads to the formation of potential barriers at grain boundaries with a simultaneous increase of grain-boundary capacitance and non-Ohmic features of the polycrystalline device doped with Nb atoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVOS: Comparar a neurorrafia término-lateral com epineuro versus sem epineuro. DESENHO: Foram operados 20 ratos. O nervo fibular foi seccionado e seu coto distal suturado na face lateral do nervo tibial. do lado direito nós removemos janela de epineuro e no lado esquerdo o epineuro foi deixado intacto. Depois de seis meses, os 14 animais sobreviventes foram submetidos a testes eletrofisiológicos, sacrificados e os nervos e músculos removidos para exames histológicos. O teste eletrofisiológico foi realizado mediante estímulo elétrico fornecido por um neuro-estimulador (LHM-110) com 2 milisegundos de duração, num modo repetido e 30 Hz. O estímulo foi aumentado progressivamente partindo de zero até atingir 1 volt. LOCAL: Faculdade de Medicina de Botucatu. RESULTADOS: No lado direito, os músculos que tiveram resposta positiva necessitaram uma média de 258,89 mv (±92,31) de estímulo elétrico para apresentar uma resposta e no lado esquerdo uma média de 298,34 mV (±139,32). O músculo tibial cranial apresentou peso médio para o lado direito de 0,47 g (±0,18) e para o lado esquerdo de 0,45 g (±0,15). O coto distal do nervo fibular apresentou uma média 310 fibras nervosas (±191,34) para o lado direito e 287,71 (±183,60) para o lado esquerdo. O nervo tibial acima da neurorrafia mostrou médias de 939,46 (±223,51) fibras nervosas para o lado direito e 959,46 (±327,48) para o lado esquerdo. O nervo tibial abaixo da neurorrafia mostrou médias de 935,17 (±298,65) fibras nervosas para o lado direito e 755,31 (±323,26) para o lado esquerdo. As fibras do músculo tibial cranial do lado direito apresentaram uma área média de 0,0162 (±0,008) m2 depois de 230 vezes de magnificação e 0,0152 (±0,0064) para as fibras do músculo tibial cranial do lado esquerdo. O aspecto histológico do músculo tibial cranial, tomando-se o normal como 100% foi de 78,21 (±20,75) para o lado direito e 82,14 (±15,89) para o lado esquerdo. A análise estatística (testetde Student) não mostrou diferenças (p>0,05) entre os lados esquerdo e direito para todas as variáveis. CONCLUSÕES: Ambas as neurorrafias (com e sem epineuro) não mostraram diferenças relacionadas aos aspectos morfológicos e eletrofisiológicos estudados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This text discusses about advantageous, powerful and limitations of admittance and dielectric spectroscopy in the characterization of polycrystalline semiconductors. In the context of polycrystalline semiconductors or dielectric materials, the admittance or dielectric frequency response analyses are shown to be sometimes more useful than impedance spectra analysis, mainly because information on the capacitances or deep trap states are possible to be monitored from admittance or dielectric spectra as a function of dopant concentration or annealing effects. The majority of examples of the application of admittance or dielectric analysis approach were here based on SnO2- and ZnO-based polycrystalline semiconductors devices presenting nonohmic properties. Examples of how to perform the characterization of Schottky barrier in such devices are clearly depicted. The approach is based on findings of the true Mott-Schottky pattern of the barrier by extracting the grain boundary capacitance value from complex capacitance diagram analysis. The equivalent circuit of such kind of devices is mainly consistent with the existence of three parallel elements: the high-frequency limit related to grain boundary capacitances, the complex incremental capacitance at intermediate frequency related to the deep trap relaxation and finally at low frequency region the manifestation of the conductance term representing the dc conductance of the multi-junction device. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of electrochemical potentiokinetic methods as applied to the testing of metals and alloys is followed from its early phases up to its latest advances relating to intergranular corrosion, SCC and pitting corrosion tests of stainless steels and special alloys and to the examination of their structure and properties. In assessing the susceptibility to intergranular and pitting corrosion by potentiokinetic polarization tests, the polarization curves which apply to the bulk of the alloy grains (the matrix) must be distinguished from those pertaining to grain boundaries. Cyclic polarization measurements such as the electrochemical potentiokinetic reactivation (EPR) test make it possible to derive the alloy's susceptibility to intergranular, pitting and crevice corrosion from characteristic potentials and other quantities determined in the 'double loop' test. EPR is rapid and responds to the combined effects of a number of factors that influence the properties of materials. The electrochemical p otentiokinetic tests are sensitive enough to detect structural changes in heat treated materials ranging far beyond the stainless steels alone, and can be used for non-destructive testing aimed at elucidating the properties and behavior of materials. © 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polymeric precursor solution (Pechini method) was used to deposit LiNbO 3 thin films by spin-coating on (100) silicon substrates. X-ray diffraction data of thin films showed that the increase of oxygen flow promotes a preferred orientation of (001) LiNbO 3 planes parallel to the substrate surface. Surface roughness and grain size, observed by atomic force microscopy, change also with oxygen flow. © 2002 Taylor & Francis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the resistance to fracture of intact and restored human maxillary premolars. METHOD AND MATERIALS: Thirty noncarious human maxillary premolars, divided into three groups of 10, were submitted to mechanical tests to evaluate their resistance to fracture. Group 1 consisted of intact teeth. Teeth in group 2 received mesio-occlusodistal cavity preparations and were restored with direct resin composite restorations. Teeth in group 3 received mesio-occlusodistal cavity preparations and were restored with ceromer inlays placed with the indirect technique. After restoration, teeth were stored at 37 degrees C for 24 hours and then thermocycled for 500 cycles at temperatures of 5 degrees C and 55 degrees C. RESULTS: Statistical analysis revealed that group 3 (178.765 kgf) had a significantly greater maximum rupture load than did group 1 (120.040 kgf). There was no statistically significant difference between groups 1 and 2 or between groups 2 and 3. CONCLUSION: Class II cavity preparations restored with indirect ceromer inlays offered greater resistance to fracture than did intact teeth. The fracture resistance of teeth restored with resin composite was not significantly different from that of either the ceromer or intact teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the effect of three surface conditioning methods on the microtensile bond strength of resin cement to a glass-infiltrated zirconia-reinforced alumina-based core ceramic. Thirty blocks (5×5×4 mm) of In-Ceram Zirconia ceramics (In-Ceram Zirconia-INC-ZR, VITA) were fabricated according to the manufacturer's instructions and duplicated in resin composite. The specimens were polished and assigned to one of the following three treatment conditions (n=10): (1) Airborne particle abrasion with 110 μm Al2O3 particles + silanization, (2) Silica coating with 110 μm SiOx particles (Rocatec Pre and Plus, 3M ESPE) + silanization, (3) Silica coating with 30 μm SiOx particles (CoJet, 3M ESPE) + silanization. The ceramic-composite blocks were cemented with the resin cement (Panavia F) and stored at 37 °C in distilled water for 7 days prior to bond tests. The blocks were cut under coolant water to produce bar specimens with a bonding area of approximately 0.6 mm2. The bond strength tests were performed in a universal testing machine (cross-head speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using ANOVA and Tukey's test (α≤0.05). Silica coating with silanization either using 110 μm SiOx or 30 μm SiOx particles increased the bond strength of the resin cement (24.6±2.7 MPa and 26.7±2.4 MPa, respectively) to the zirconia-based ceramic significantly compared to that of airborne particle abrasion with 110-μm Al2O3 (20.5±3.8 MPa) (ANOVA, P<0.05). Conditioning the INC-ZR ceramic surfaces with silica coating and silanization using either chairside or laboratory devices provided higher bond strengths of the resin cement than with airborne particle abrasion using 110 μm Al2O3. © 2005 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The force delivered during rapid maxillary expansion (RME) produces areas of compression on the periodontal ligament of the supporting teeth. The resulting alveolar bone resorption can lead to unwanted tooth movement in the same direction. The purpose of this study was to evaluate periodontal changes by means of computed tomography after RME with tooth-tissue-borne and tooth-borne expanders. Methods: The sample comprised 8 girls, 11 to 14 years old, with Class I or II malocclusions with unilateral or bilateral posterior crossbites Four girls were treated with tooth-tissue-borne Haas-type expanders, and 4 were treated with tooth-borne Hyrax expanders. The appliances were activated up to the full 7-mm capacity of the expansion screw. Spiral CT scans were taken before expansion and after the 3-month retention period when the expander was removed. One-millimeter thick axial sections were exposed parallel to the palatal plane, comprising the dentoalveolar area and the base of the maxilla up to the inferior third of the nasal cavity. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal alveolar bone crest level by means of the computerized method. Results and Conclusions: RME reduced the buccal bone plate thickness of supporting teeth 0.6 to 0.9 mm and increased the lingual bone plate thickness 0.8 to 1.3 mm. The increase in lingual bone plate thickness of the maxillary posterior teeth was greater in the tooth-borne expansion group than in the tooth-tissue-borne group. RME induced bone dehiscences on the anchorage teeth's buccal aspect (7.1 ± 4.6 mm at the first premolars and 3.8 ± 4.4 mm at the mesiobuccal area of the first molars), especially in subjects with thinner buccal bone plates. The tooth-borne expander produced greater reduction of first premolar buccal alveolar bone crest level than did the tooth-tissue-borne expander. © 2006 American Association of Orthodontists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of two surface conditioning methods on the microtensile bond strength of a resin cement to three high-strength core ceramics: high alumina-based (In-Ceram Alumina, Procera AllCeram) and zirconia-reinforced alumina-based (In-Ceram Zirconia) ceramics. Materials and Methods: Ten blocks (5 ×6 × 8 mm) of In-Ceram Alumina (AL), In-Ceram Zirconia (ZR), and Procera (PR) ceramics were fabricated according to each manufacturer's instructions and duplicated in composite. The specimens were assigned to one of the two following treatment conditions: (1) airborne particle abrasion with 110-μm Al2O3 particles + silanization, (2) silica coating with 30 μm SiOx particles (CoJet, 3M ESPE) + silanization. Each ceramic block was duplicated in composite resin (W3D-Master, Wilcos, Petrópolis, RJ, Brazil) using a mold made out of silicon impression material. Composite resin layers were incrementally condensed into the mold to fill up the mold and each layer was light polymerized for 40 s. The composite blocks were bonded to the surface-conditioned ceramic blocks using a resin cement system (Panavia F, Kuraray, Okayama, Japan). One composite resin block was fabricated for each ceramic block. The ceramic-composite was stored at 37°C in distilled water for 7 days prior to bond tests. The blocks were cut under water cooling to produce bar specimens (n = 30) with a bonding area of approximately 0.6 mm2. The bond strength tests were performed in a universal testing machine (crosshead speed: 1 mm/min). Bond strength values were statistically analyzed using two-way ANOVA and Tukey's test (≤ 0.05). Results: Silica coating with silanization increased the bond strength significantly for all three high-strength ceramics (18.5 to 31.2 MPa) compared to that of airborne particle abrasion with 110-μm Al2O3 (12.7-17.3 MPa) (ANOVA, p < 0.05). PR exhibited the lowest bond strengths after both Al2O3 and silica coating (12.7 and 18.5 MPa, respectively). Conclusion: Conditioning the high-strength ceramic surfaces with silica coating and silanization provided higher bond strengths of the resin cement than with airborne particle abrasion with 110-μm Al2O3 and silanization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A large portion of Brazil is covered with tropical soils but literature about dynamic parameters of these soils is very limited. SCPT and cross-hole tests were carried out at an experimental research site inland in the state of São Paulo, Brazil. Shear wave velocities (VS) determined based on both tests are presented and compared. A good agreement was observed between both test results and the differences can be associated with soil variability, which was very sensitive to CPT tests. It was also observed that Go/q c ratio determined based on SCPT appears to be an interesting technique to help identify tropical soils. Copyright ASCE 2006.