234 resultados para Aço inoxidável vazado
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Introduction: Currently, there are many questions regarding the cleaning methods seeking greater efficiency and less loss of burs. Aim: the aim of this study was to evaluate the influence of cleaning methods on the cutting efficiency and morphological characteristics of stainless steel burs tungsten carbide (carbide). Materials and method: Thirty burs were divided into five groups (n = 5) according with the cleaning method: L1 - steel brush, L2 - nylon brush, L3 - ultrasound + distilled water, L4 - ultrasound + descaling solution and L5 - no cleaning method (control). The burs were used for the cutting of bovine enamel during six periods of 12 minutes each. After each period, the burs were cleaned (except L5 ) following the protocol established for each group. The cutting efficiency was determined by mass loss and morphological characteristics. Result: The average amount of wear after 72 minutes of use were L1 = 0.3558 g; L2 = 0.4275 g; L3 = 0.4652 g; L4 = 0.4396 g e L5 = 0.4854 g; significant differences in the time of use (p < 0.001) and cleaning method (p < 0.001). The L1 group showed the worst performance. Regardless of the experimental group, morphological analysis revealed alterations in the cutting blades soon after the first 12 minutes, being L1 the most affected group. Conclusion: The cleaning with wire brush was the most damaging method to the cutting efficiency and to the morphology of carbide burs.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
During clinical routine, the orthodontist uses several materials, which include metallic alloys in the form of metallic wires. However, it is necessary that the professional has some knowledge of the properties of those wires. Different types of wires are commercially available: stainless steel wires, chrome-cobalt wires, nickel-titanium wires and beta-titanium wires. Among the nickel-titanium wires, there are three subdivisions: a conventional alloy and two superelastic alloys. The superelasticity, associated to the effect of form memory, is a property used in orthodontics to initiate the dental movement in the first phase of the orthodontic treatment. This property is considered to be biologically compatible with the effective dental movement. These wires are available at the market in different transformation temperatures, and they offer the best adaptation in the groove of the bracket, simplicity and a faster treatment. However, they present little formability, and they don’t accept solder. They are also more onerous than other wires. Moreover, the low rigidity of these wires doesn’t allow them to be used for the retraction of the anterior teeth or closing of spaces. Therefore, the coherent use of superelastic orthodontic wires is recommended, accompanied by a detailed diagnosis and planning, so the result will be an efficient orthodontic correction, accomplished in a shorter period of time.
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Pós-graduação em Biotecnologia Animal - FMVZ
Resumo:
Background: The reduction of the pelvic floor muscles (PFM) strength is a major cause of stress urinary incontinence (SUI). Objective: To compare active and passive forces, and vaginal cavity aperture in continent and stress urinary incontinent women. Method: The study included a total of thirty-two women, sixteen continent women (group 1 - G1) and sixteen women with SUI (group 2 - G2). To evaluate PFM passive and active forces in anteroposterior (sagittal plane) and left-right directions (frontal plane) a stainless steel specular dynamometer was used. Results: The anteroposterior active strength for the continent women (mean +/- standard deviation) (0.3 +/- 0.2 N) was greater compared to the values found in the evaluation of incontinent women (0.1 +/- 0.1 N). The left-right active strength (G1=0.43 +/- 0.1 N; G2=0.40 +/- 0.1 N), the passive force (G1=1.1 +/- 0.2 N; G2=1.1 +/- 0.3 N) and the vaginal cavity aperture (G1=21 +/- 3 mm; G2=24 +/- 4 mm) did not differ between groups 1 and 2. Conclusion: The function evaluation of PFM showed that women with SUI had a lower anteroposterior active strength compared to continent women.
Resumo:
This work provides a numerical and experimental investigation of fatigue crack growth behavior in steel weldments including crack closure effects and their coupled interaction with weld strength mismatch. A central objective of this study is to extend previously developed frameworks for evaluation of crack clo- sure effects on FCGR to steel weldments while, at the same time, gaining additional understanding of commonly adopted criteria for crack closure loads and their influence on fatigue life of structural welds. Very detailed non-linear finite element analyses using 3-D models of compact tension C ( T ) fracture spec- imens with center cracked, square groove welds provide the evolution of crack growth with cyclic stress intensity factor which is required for the estimation of the closure loads. Fatigue crack growth tests con- ducted on plane-sided, shallow-cracked C ( T ) specimens provide the necessary data against which crack closure effects on fatigue crack growth behavior can be assessed. Overall, the present investigation pro- vides additional support for estimation procedures of plasticity-induced crack closure loads in fatigue analyses of structural steels and their weldments
Resumo:
The most important property of austenitic stainless steels is corrosion resistance. In these steels, the transition between paramagnetic and ferromagnetic conditions occurs at low temperatures. Therefore, the use of austenitic stainless steels in conditions in which ferromagnetism absence is important can be considered. On the other hand, the formation of strain-induced martensite is detected when austenitic stainless steels are deformed as well as machined. The strain-induced martensite formed especially in the machining process is not uniform through the chip and its formation can also be related to the Md temperature. Therefore, both the temperature distribution and the gradient during the cutting and chip formation are important to identify regions in which martensite formation is propitiated. The main objective here is evaluate the strain-induced martensite formation throughout machining by observing microstructural features and comparing these to thermal results obtained through finite element method analysis. Results show that thermal analysis can give support to the martensite identified in the microstructural analysis.
Resumo:
The purpose of this study is to evaluate the influence of the cutting parameters of high-speed machining milling on the characteristics of the surface integrity of hardened AISI H13 steel. High-speed machining has been used intensively in the mold and dies industry. The cutting parameters used as input variables were cutting speed (v c), depth of cut (a p), working engagement (a e) and feed per tooth (f z ), while the output variables were three-dimensional (3D) workpiece roughness parameters, surface and cross section microhardness, residual stress and white layer thickness. The subsurface layers were examined by scanning electron and optical microscopy. Cross section hardness was measured with an instrumented microhardness tester. Residual stress was measured by the X-ray diffraction method. From a statistical standpoint (the main effects of the input parameters were evaluated by analysis of variance), working engagement (a e) was the cutting parameter that exerted the strongest effect on most of the 3D roughness parameters. Feed per tooth (f z ) was the most important cutting parameter in cavity formation. Cutting speed (v c) and depth of cut (a p) did not significantly affect the 3D roughness parameters. Cutting speed showed the strongest influence on residual stress, while depth of cut exerted the strongest effect on the formation of white layer and on the increase in surface hardness.
Resumo:
O objetivo deste trabalho foi analisar a expressão dos torques dentários em pacientes tratados com aparelhos ortodônticos fixos com bráquetes autoligados, utilizando tomografias computadorizadas. Para este estudo, foi selecionada uma amostra clínica de 10 pacientes, seguindo como critérios de inclusão, indivíduos que apresentavam dentição permanente e todos os dentes presentes, com apinhamento superior ou igual a 4 mm, tratados sem extração. Todos os pacientes foram tratados na clínica da pós-graduação em Ortodontia da Universidade Metodista de São Paulo, utilizando-se bráquetes autoligados Damon 2 ORMCO na prescrição padrão. Foram realizadas medições das inclinações dos dentes anteriores, de canino a canino, superiores e inferiores, realizadas por meio de imagens tomográficas obtidas em um tomógrafo computadorizado volumétrico NewTom, em seu modelo DVT-9000 (NIM Verona - Itália), obtidas em dois tempos: antes do início do tratamento ortodôntico (denominado de T1) e depois do tratamento ortodôntico, após a inserção do último fio de nivelamento, de calibre 0,019 x 0,025 de aço inoxidável(denominado de T2). Para auxílio destas mensurações, foi utilizado o software QR-DVT 9000 e após análise dos resultados foram aplicados testes estatíscos (testes "t" pareado e Dalberg) e observou-se que as inclinações dos dentes do segmento anterior aumentaram, principalmente, nos caninos e incisivos laterais superiores, incisivos centrais e laterais inferiores. Os dentes apresentaram valores de inclinação diferentes da prescrição, tanto no início quanto no final do tratamento, denotando a incapacidade do fio 0,019 x 0,025 de aço inoxidável em reproduzir os torques indicados na prescrição padrão utilizada neste presente estudo.(AU)
Resumo:
O objetivo deste trabalho foi analisar a expressão dos torques dentários em pacientes tratados com aparelhos ortodônticos fixos com bráquetes autoligados, utilizando tomografias computadorizadas. Para este estudo, foi selecionada uma amostra clínica de 10 pacientes, seguindo como critérios de inclusão, indivíduos que apresentavam dentição permanente e todos os dentes presentes, com apinhamento superior ou igual a 4 mm, tratados sem extração. Todos os pacientes foram tratados na clínica da pós-graduação em Ortodontia da Universidade Metodista de São Paulo, utilizando-se bráquetes autoligados Damon 2 ORMCO na prescrição padrão. Foram realizadas medições das inclinações dos dentes anteriores, de canino a canino, superiores e inferiores, realizadas por meio de imagens tomográficas obtidas em um tomógrafo computadorizado volumétrico NewTom, em seu modelo DVT-9000 (NIM Verona - Itália), obtidas em dois tempos: antes do início do tratamento ortodôntico (denominado de T1) e depois do tratamento ortodôntico, após a inserção do último fio de nivelamento, de calibre 0,019 x 0,025 de aço inoxidável(denominado de T2). Para auxílio destas mensurações, foi utilizado o software QR-DVT 9000 e após análise dos resultados foram aplicados testes estatíscos (testes "t" pareado e Dalberg) e observou-se que as inclinações dos dentes do segmento anterior aumentaram, principalmente, nos caninos e incisivos laterais superiores, incisivos centrais e laterais inferiores. Os dentes apresentaram valores de inclinação diferentes da prescrição, tanto no início quanto no final do tratamento, denotando a incapacidade do fio 0,019 x 0,025 de aço inoxidável em reproduzir os torques indicados na prescrição padrão utilizada neste presente estudo.(AU)