976 resultados para measurement technology


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drawing on extensive academic research and theory on clusters and their analysis, the methodology employed in this pilot study (sponsored by the Welsh Assembly Government’s Economic Research Grants Assessment Board) seeks to create a framework for reviewing and monitoring clusters in Wales on an ongoing basis, and generate the information necessary for successful cluster development policy to occur. The multi-method framework developed and tested in the pilot study is designed to map existing Welsh sectors with cluster characteristics, uncover existing linkages, and better understand areas of strength and weakness. The approach adopted relies on synthesising both quantitative and qualitative evidence. Statistical measures, including the size of potential clusters, are united with other evidence on input-output derived inter-linkages within clusters and to other sectors in Wales and the UK, as well as the export and import intensity of the cluster. Multi Sector Qualitative Analysis is then designed for competencies/capacity, risk factors, markets, types and crucially, the perceived strengths of cluster structures and relationships. The approach outlined above can, with the refinements recommended through the review process, provide policy-makers with a valuable tool for reviewing and monitoring individual sectors and ameliorating problems in sectors likely to decline further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper describes a system for measuring radiation efficiency of a small antenna operating alone or in the presence of objects similar to those as in an actual service. The system applies the direct approach to determining the antenna efficiency by measuring the radiated field over the entire sphere surrounding the tested antenna. In order to overcome problems associated with the conventional measuring equipment, the antenna under test is equipped with a miniature built-in VCO signal generator and supported by a low reflectivity dielectric positioner. The positioner is of sufficient size and strength to hold a human head phantom to investigate changes in radiation characteristics when the antenna operates in the presence of a human operator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper describes a high fidelity system for measuring a radiation pattern of an electrically small antenna. In this system, the Antenna Under Test (AUT) equipped with a battery powered signal generator is suspended by a dielectric foam in the centre of a pair of dielectric rings that are supported by a pedestal of a spherical positioning mechanical sub-system. Radiation patterns are obtained directly in spherical format using a suitably constructed probe antenna of linear or circular polarization. Measurements are controlled by a computer, which also stores and processes the measured data. The results reveal considerable differences between the radiation patterns of a small antenna obtained using the proposed wireless approach and the conventional one, in which the antenna is connected with a cable to the receiver.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional detection scheme for self-mixing sensors uses an integrated photodiode within the laser package to monitor the self mixing signal. This arrangement can be simplified by directly obtaining the self-mixing signals across the laser diode itself and omitting the photodiode. This work reports on a Vertical-Cavity Surface-Emitting Laser (VCSEL) based selfmixing sensor using the laser junction voltage to obtain the selfmixing signal. We show that the same information can be obtained with only minor changes to the extraction circuitry leading to potential cost saving with reductions in component costs and complexity and significant increase in bandwidth favoring high speed modulation. Experiments using both photo current and voltage detection were carried out and the results obtained show good agreement with the theory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Intensive Care Unit (ICU) being one of those vital areas of a hospital providing clinical care, the quality of service rendered must be monitored and measured quantitatively. It is, therefore, essential to know the performance of an ICU, in order to identify any deficits and enable the service providers to improve the quality of service. Although there have been many attempts to do this with the help of illness severity scoring systems, the relative lack of success using these methods has led to the search for a form of measurement, which would encompass all the different aspects of an ICU in a holistic manner. The Analytic Hierarchy Process (AHP), a multiple-attribute, decision-making technique is utilised in this study to evolve a system to measure the performance of ICU services reliably. This tool has been applied to a surgical ICU in Barbados; we recommend AHP as a valuable tool to quantify the performance of an ICU. Copyright © 2004 Inderscience Enterprises Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fare, Grosskopf, Norris and Zhang developed a non-parametric productivity index, Malmquist index, using data envelopment analysis (DEA). The Malmquist index is a measure of productivity progress (regress) and it can be decomposed to different components such as 'efficiency catch-up' and 'technology change'. However, Malmquist index and its components are based on two period of time which can capture only a part of the impact of investment in long-lived assets. The effects of lags in the investment process on the capital stock have been ignored in the current model of Malmquist index. This paper extends the recent dynamic DEA model introduced by Emrouznejad and Thanassoulis and Emrouznejad for dynamic Malmquist index. This paper shows that the dynamic productivity results for Organisation for Economic Cooperation and Development countries should reflect reality better than those based on conventional model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New technology means that self-measurement or testing of blood pressure (BP) is potentially available for many people but few data exist on how common it is. A community survey in Birmingham, UK in June 2005 (2931 responders; response rate 54%) of self-testing of BP showed that 9% of a randomly selected population sample had self-tested their own BP. Greater public awareness of BP through self-testing has the potential to improve the detection and treatment of BP but this will only be possible if professionals are aware of it.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose and demonstrate a novel scheme for simultaneous measurement of liquid level and temperature based on a simple uniform fiber Bragg grating (FBG) by monitoring both the short-wavelength-loss peaks and its Bragg resonance. The liquid level can be measured from the amplitude changes of the short-wavelength-loss peaks, while temperature can be measured from the wavelength shift of the Bragg resonance. Both theoretical simulation results and experimental results are presented. Such a scheme has some advantages including robustness, simplicity, flexibility in choosing sensitivity and simultaneous temperature measurement capability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microchannel was inscribed in the fiber of a ring cavity which was constructed using two 0.1%:99.9% couplers and a 10-m fiber loop. Cavity ring down spectroscopy was used to measure the refractive index (RI) of gels infused into the microchannel. The ring down time discloses a nonlinear increase with respect to RI of the gel and sensitivity up to 300 µs/RI unit and an index resolution of 1.4 × 10 was obtained. © 2009 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two energy grass species, switch grass, a North American tuft grass, and reed canary grass, a European native, are likely to be important sources of biomass in Western Europe for the production of biorenewable energy. Matching chemical composition to conversion efficiency is a primary goal for improvement programmes and for determining the quality of biomass feed-stocks prior to use and there is a need for methods which allow cost effective characterisation of chemical composition at high rates of sample through-put. In this paper we demonstrate that nitrogen content and alkali index, parameters greatly influencing thermal conversion efficiency, can be accurately predicted in dried samples of these species grown under a range of agronomic conditions by partial least square regression of Fourier transform infrared spectra (R2 values for plots of predicted vs. measured values of 0.938 and 0.937, respectively). We also discuss the prediction of carbon and ash content in these samples and the application of infrared based predictive methods for the breeding improvement of energy grasses.